• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogs

Martins Neto, Evandro Carneiro 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
2

Avaliação do plasma de argônio na integração dos tecidos moles e duros aos implantes e componentes protéticos: estudo randomizado em cães / Evaluation of argon plasma in the integration of soft and hard tissues to implants and prosthetic components: a randomized study in dogs

Evandro Carneiro Martins Neto 07 December 2017 (has links)
Diversas aplicações do plasma de argônio tem sido encontradas na literatura. Na odontologia, suas aplicações se referem a capacidade de limpeza de componentes e aumento da energia de superfície. Os tratamentos para melhorar a energia de superfície são estudados com objetivo de criar um ambiente mais favorável para a adesão celular. Este estudo teve como objetivo avaliar histologicamente as mudanças nos tecidos moles e duros após a inserção de implantes e pilares de titânio limpos e ativados com plasma de argônio. Foram instalados 64 implantes e pilares em 8 cães Beagle, sendo randomizados em dois grupos: tratados com plasma de argônio ou não tratados. Dois tempos experimentais foram realizados: 4 e 8 semanas. Após esse período, os animais foram sacrificados, as mandíbulas foram divididas em blocos individuais e processados para confecção de lâminas para análise histológica. Na análise dos pilares, não houve diferença estatística entre os grupos, apesar de maiores níveis de osso marginal nos locais de teste em comparação com os locais de controle. Em relação aos implantes de titânio, as diferenças entre teste e controle, principalmente no período de 8 semanas, podem sugerir que o uso de plasma de argônio poderia melhorar a integração dos tecidos periimplantares à superficie dos implantes. / Several applications of argon plasma have been found in the literature. In dentistry, its applications refer to the ability to clean components and increase surface energy. Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. This study aimed to histologically evaluate changes in soft and hard tissues after insertion of implants and titanium abutments cleaned and activated with argon plasma. 64 implants and abutments were installed in 8 Beagle dogs, and were randomized into two groups: treated with argon plasma or untreated. Two experimental times were performed: 4 and 8 weeks. After this period, the animals were sacrificed, the jaws were divided into individual blocks and processed for histological analysis. In the analysis of abutments, there was no statistical difference between groups, despite higher levels of marginal bone in test sites compared to the control sites. Regarding titanium implants, the differences between test and control, especially in the 8-week period, may suggest that the use of argon plasma could improve the integration of peri-implant tissues to the implant surface.
3

Revisão sistemática e metanálise do tratamento endoscópico do reganho de peso pós-derivação gástrica em Y-de-Roux / Systematic review and meta-analysis of the endoscopic treatment of weight regain following Roux-en-Y gastric bypass

Brunaldi, Vítor Ottoboni 03 April 2018 (has links)
Introdução: A derivação gástrica em Y-de-Roux (DGYR) é um dos procedimentos bariátricos mais realizados em todo o mundo. Apesar de sua alta eficácia, significativa proporção de pacientes recupera parte do peso perdido. Várias terapias endoscópicas foram introduzidas como alternativas para tratar o reganho de peso, mas a maioria dos artigos publicados tem amostra relativamente pequena, com dados pouco claros e de curto prazo. Objetivo: Avaliar sistematicamente a eficácia das terapias endoscópicas para reganho de peso pós-DGYR. Métodos: Foram realizadas buscas nas bases MEDLINE, EMBASE, Scopus, Web of Science, Cochrane, OVID, CINAHL/EBSCo, LILACS/Bireme e literatura cinzenta. Os desfechos primários avaliados foram perda absoluta de peso (PAP), perda de excesso de peso (PEP) e perda total de peso corporal (PPTP). Resultados: Trinta e dois estudos foram incluídos na análise qualitativa. Vinte e seis trabalhos envolvendo 1148 pacientes descreveram sutura endoscópica de espessura total (SET) e PAP, PEP e PPTP em 3 meses foram 8,5±2,9kg, 21,6±9,3% e 7,3±2,6%, respectivamente. Aos 6 meses, foram de 8,6±3,5kg, 23,7±12,3% e 8,0±3,9%. Aos 12 meses, 7,63±4,3kg, 16,9±11,1% e 6,6±5,0%. A análise de subgrupos mostrou melhores resultados no subgrupo submetido à coagulação com plasma de argônio (APC) prévio à SET (p < 0,0001). A metanálise incluindo 15 desses estudos mostrou resultados concordantes e confirmou a superioridade estatística da SET+APC em comparação à SET isolada. Três estudos descreveram sutura de espessura superficial (SEP) com PAP média de 3,0±3,8kg, 4,4±0,07kg e 3,7±7,4 kg em 3, 6 e 12 meses, respectivamente. No seguimento de curto, médio e longo prazo, a SET proporcionou resultados superiores em relação à SEP (p < 0,05). Dois artigos descreveram APC isolada com PAP média de 15,4±2,0 kg e 15,4±9,1kg em 3 e 6 meses. Nenhum estudo relatando escleroterapia satisfez os critérios de elegibilidade. Conclusões: A sutura de espessura total é efetiva no tratamento do reganho de peso pós-DGYR. A realização de APC antes da sutura parece resultar em maior perda de peso. Estudos comparativos são necessários para confirmar nossos resultados. A sutura de espessura total relaciona-se com melhores resultados em comparação à sutura de espessura superficial. Poucos estudos avaliam adequadamente a eficácia de outras técnicas endoscópicas / Introduction: Roux-en-Y Gastric Bypass (RYGB) is the most commonly performed bariatric procedure. Despite its high efficacy, some patients regain part of their lost weight. Several endoscopic therapies have been introduced as alternatives to treat weight regain but most of the articles are relatively small with unclear long-term data. Aim: To systematically assess the efficacy of endoscopic therapies for weight regain after RYGB. Methods: We searched MEDLINE, EMBASE, Scopus, Web of Science, Cochrane, OVID, CINAHL/EBSCo, LILACS/Bireme and gray literature. Primary outcomes were absolute weight loss (AWL), excess weight loss (EWL) and total body weight loss (TBWL). Results: Thirty-two studies were included in qualitative analysis. Twenty-six articles enrolling 1148 patients described fullthickness (FT) endoscopic suturing and pooled AWL, EWL and TBWL at 3 months were 8.5±2.9kgs, 21.6±9.3% and 7.3±2.6%, respectively. At 6 months, they were 8.6±3.5kg, 23.7±12.3% and 8.0±3.9%. At 12 months, they were 7.63±4.3kg, 16.9±11.1% and 6.6±5.0%. Subgroup analysis showed that all outcomes were significantly higher in the group with FT suturing combined with argon plasma coagulation (APC) (p < 0.0001). Meta-analysis including 15 FT studies showed greater results and confirmed the significant superiority of FT-APC compared to FT alone. Three studies described superficial-thickness suturing with pooled AWL of 3.0±3.8kg, 4.4±0.07kg and 3.7±7.4kg at 3, 6 and 12 months, respectively. At short, mid and long-term follow-up, FT suturing provided better outcomes compared to ST (p < 0.05). Two articles described APC alone with mean AWL of 15.4±2.0kg and 15.4±9.1kg at 3 and 6 months. No study describing sclerotherapy fulfilled eligibility criteria. Conclusions: Full-thickness suturing is effective at treating weight regain after RYGB. Performing APC prior to suturing seems to result in greater weight loss. Head-to-head studies are needed to confirm our results. Full-thickness suturing lead to greater outcomes compared to superficial thickness suturing. Few studies adequately assess effectiveness of other endoscopic techniques
4

Revisão sistemática e metanálise do tratamento endoscópico do reganho de peso pós-derivação gástrica em Y-de-Roux / Systematic review and meta-analysis of the endoscopic treatment of weight regain following Roux-en-Y gastric bypass

Vítor Ottoboni Brunaldi 03 April 2018 (has links)
Introdução: A derivação gástrica em Y-de-Roux (DGYR) é um dos procedimentos bariátricos mais realizados em todo o mundo. Apesar de sua alta eficácia, significativa proporção de pacientes recupera parte do peso perdido. Várias terapias endoscópicas foram introduzidas como alternativas para tratar o reganho de peso, mas a maioria dos artigos publicados tem amostra relativamente pequena, com dados pouco claros e de curto prazo. Objetivo: Avaliar sistematicamente a eficácia das terapias endoscópicas para reganho de peso pós-DGYR. Métodos: Foram realizadas buscas nas bases MEDLINE, EMBASE, Scopus, Web of Science, Cochrane, OVID, CINAHL/EBSCo, LILACS/Bireme e literatura cinzenta. Os desfechos primários avaliados foram perda absoluta de peso (PAP), perda de excesso de peso (PEP) e perda total de peso corporal (PPTP). Resultados: Trinta e dois estudos foram incluídos na análise qualitativa. Vinte e seis trabalhos envolvendo 1148 pacientes descreveram sutura endoscópica de espessura total (SET) e PAP, PEP e PPTP em 3 meses foram 8,5±2,9kg, 21,6±9,3% e 7,3±2,6%, respectivamente. Aos 6 meses, foram de 8,6±3,5kg, 23,7±12,3% e 8,0±3,9%. Aos 12 meses, 7,63±4,3kg, 16,9±11,1% e 6,6±5,0%. A análise de subgrupos mostrou melhores resultados no subgrupo submetido à coagulação com plasma de argônio (APC) prévio à SET (p < 0,0001). A metanálise incluindo 15 desses estudos mostrou resultados concordantes e confirmou a superioridade estatística da SET+APC em comparação à SET isolada. Três estudos descreveram sutura de espessura superficial (SEP) com PAP média de 3,0±3,8kg, 4,4±0,07kg e 3,7±7,4 kg em 3, 6 e 12 meses, respectivamente. No seguimento de curto, médio e longo prazo, a SET proporcionou resultados superiores em relação à SEP (p < 0,05). Dois artigos descreveram APC isolada com PAP média de 15,4±2,0 kg e 15,4±9,1kg em 3 e 6 meses. Nenhum estudo relatando escleroterapia satisfez os critérios de elegibilidade. Conclusões: A sutura de espessura total é efetiva no tratamento do reganho de peso pós-DGYR. A realização de APC antes da sutura parece resultar em maior perda de peso. Estudos comparativos são necessários para confirmar nossos resultados. A sutura de espessura total relaciona-se com melhores resultados em comparação à sutura de espessura superficial. Poucos estudos avaliam adequadamente a eficácia de outras técnicas endoscópicas / Introduction: Roux-en-Y Gastric Bypass (RYGB) is the most commonly performed bariatric procedure. Despite its high efficacy, some patients regain part of their lost weight. Several endoscopic therapies have been introduced as alternatives to treat weight regain but most of the articles are relatively small with unclear long-term data. Aim: To systematically assess the efficacy of endoscopic therapies for weight regain after RYGB. Methods: We searched MEDLINE, EMBASE, Scopus, Web of Science, Cochrane, OVID, CINAHL/EBSCo, LILACS/Bireme and gray literature. Primary outcomes were absolute weight loss (AWL), excess weight loss (EWL) and total body weight loss (TBWL). Results: Thirty-two studies were included in qualitative analysis. Twenty-six articles enrolling 1148 patients described fullthickness (FT) endoscopic suturing and pooled AWL, EWL and TBWL at 3 months were 8.5±2.9kgs, 21.6±9.3% and 7.3±2.6%, respectively. At 6 months, they were 8.6±3.5kg, 23.7±12.3% and 8.0±3.9%. At 12 months, they were 7.63±4.3kg, 16.9±11.1% and 6.6±5.0%. Subgroup analysis showed that all outcomes were significantly higher in the group with FT suturing combined with argon plasma coagulation (APC) (p < 0.0001). Meta-analysis including 15 FT studies showed greater results and confirmed the significant superiority of FT-APC compared to FT alone. Three studies described superficial-thickness suturing with pooled AWL of 3.0±3.8kg, 4.4±0.07kg and 3.7±7.4kg at 3, 6 and 12 months, respectively. At short, mid and long-term follow-up, FT suturing provided better outcomes compared to ST (p < 0.05). Two articles described APC alone with mean AWL of 15.4±2.0kg and 15.4±9.1kg at 3 and 6 months. No study describing sclerotherapy fulfilled eligibility criteria. Conclusions: Full-thickness suturing is effective at treating weight regain after RYGB. Performing APC prior to suturing seems to result in greater weight loss. Head-to-head studies are needed to confirm our results. Full-thickness suturing lead to greater outcomes compared to superficial thickness suturing. Few studies adequately assess effectiveness of other endoscopic techniques
5

Dissolução eletrolítica de ligas de alumínio em cavacos e determinação dos elementos constituintes por espectrometria de emissão atômica com fonte de pasma (ICP-OES) / Electrolytic dissolution of aluminum alloys (Chip form) and multi-element determination by inductively coupled plasma optical emission spectrometry (ICP-OES)

Grigoletto, Tânia 20 March 2001 (has links)
Várias ligas de Al em cavacos, com diferentes granulometrias foram dissolvidas de modo convencional, com ataque por água régia. Este tipo de decomposição resulta, muitas vezes, em resíduos sólidos, cujas quantidades dependem dos teores de silício. A fim de se comparar os resultados, procedeuse, com esses resíduos, de dois modos distintos: ou foram desprezados ou foram decompostos com ácido fluorídrico, eliminando-se o silício, dissolvendo-se o restante com ácido nítrico e agrupando-o à primeira solução para a determinação de Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb, Sn, Ti e Zr por ICP-OES. Foi avaliada a influência de quantidades crescentes de Al na determinação destes elementos e, também, a provável interferência espectral de Cu na determinação do Zn (com e sem separação eletrolítica de Cu). A dissolução eletrolítica de ligas de alumínio em cavacos foi estudada pressionando-os contra um eletrodo de platina para que se comportassem como se fossem o próprio ânodo e a eletrólise ocorresse. Uma célula foi construída utilizando-se um tubo (corpo de seringa de 2,5 mL) com perfurações ao redor da base aberta, onde foi colocada uma malha sintética (perlon) no fundo e, sobre esta, a amostra. Na parte superior foi introduzido um pequeno tarugo de acrílico com um fio de platina passando pelo seu interior e com um orifício por onde passava o fluxo (4,5 mL min.-1) da solução eletrolítica (ácido nítrico diluído). Na extremidade inferior, prendeu-se, com o fio, uma plaquinha, também de platina, que pressionava a amostra. A solução saía pelos orifícios inferiores para um béquer de onde era recirculada e onde estava colocado o cátodo, um fio de Pt (de forma de losango), sendo novamente captada e introduzida na parte superior do tarugo do ânodo. Com esse circuito, foram obtidos bons resultados utilizando-se ácido nítrico 1 mol L-1, corrente de 0,6A e tempo de eletrólise de 10 minutos. Sendo a dissolução parcial, é necessário que se conheçam as porcentagens dos elementos por dissolução ácida total de uma liga de composição similar ou por um material de referência certificado. Normalizaram-se os dados pelas porcentagens conhecidas dos constituintes das ligas. Compararam-se os cálculos feitos dos seguintes modos: 1-) pela razão entre a concentração do elemento com a do Al, também determinada; 2-) pela a razão entre a concentração do elemento com a soma das concentrações de todos os elementos determinados, inclusive o Al; 3-) pela razão entre a concentração do elemento e a soma das concentrações só dos outros elementos, sem o Al. O desvio padrão e o erro relativo para os elementos Fe, Cu, Mg, Ni e Cr, quando em teores > 0,1%, foram < 10%; para teores de Zn < 0,2%, foram menores de 10% e para teor de 4,8% foram < 15%. Já para o Mn, quando em teor > 0,2% foram <10% (exceto para a liga B.C.S.268/1). O desvio padrão relativo para o Zr, com teor ao redor de 0,002% foi <10%. Os resultados para o elemento Pb nas ligas B.C.S. 216/1 e 380 tiveram desvio padrão e erro relativo <10%, mas o mesmo não ocorreu na liga B.C.S. 268/1. O elemento Sn apresentou resultados piores, ao redor de 20%. O elemento Ti só deu bons resultados quando em teor de cerca de 0,2%. Para estas determinações foram avaliadas as dissoluções químicas dos metais nas ligas pelo ácido nítrico em diferentes concentrações e temperaturas. Além disso, foram avaliadas duas outras células para a verificação da possibilidade de dissolução eletrolítica das ligas de Al on-line com a determinação por ICP-OES. / Several aluminum alloys with different chips size were dissolved using aqua regia (HCl:HNO3,3:1). The residues of the dissolution procedure were either rejected or used in silicon volatilization with hydrofluoric acid before determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb, Sn, Ti and Zr by ICP-OES. The influence caused by crescent amounts of aluminum in the determination of other elements and the probable spectral interference by Cu in determination of Zn (with or without electrolytic separation of Cu) was evaluated. The electrolytic dissolution of aluminum alloys was performed by pressing chips against a platinum electrode for the electrolysis to occur, so that way the chips behaved as the anode. A tube (body of syringe of 2.5mL) with perforations around the open base was used to contain the sample and Pt electrode. The alloy was placed on synthetic wool (perlon) in this tube. An acrylic dowel with a platinum wire across its interior was fixed in the superior part a tube with Teflon film, with an orifice through which the electrolytic solution flowed (HNO3 1 mol L-1; 4.5mL min-1). A platinum dish was fixed at the inferior extremity of the platinum wire to press the sample. The solution came out through the inferior orifices of the tube to a flask, from where it was again captured (with a peristaltic pump) to go into the superior part of the tube. In this flask, a Pt wire cathode was also placed. A current of 0,6A and ten minutes of electrolysis provided good results. Due to the partial dissolution, the knowledge of percentages of previous elements analyzed after total dissolution, or using certified reference material are necessary. The results were normalized by known percentages. The calculations were made by: 1-) the ratio between the concentration of the element determind, with the determined concentration of aluminum; 2-) the ratio between concentration of the element and the sum of the concentrations of the elements determined, including Al; 3-) the ratio between the concentration of element and the sum of the concentrations of the elements determined, without the aluminum. The relative standard deviations and accuracy were <10% for the elements Fe, Cu, Mg, Ni and Cr when the concentrations were >0.1%; for the Zn were 15%, when the concentration >0.2%, and <10% for concentration <0.2%. For Ti with concentration of about 0.1%, were 15%. Relative standards deviations for the Zr, with concentration of 0.002%, were always <10%. The element Pb, Sn and Mn didnt provide good results. For these determinations, the chemical dissolution of the elements with different nitric acid concentrations and temperature was evaluated. Two other cells for the electrolytic dissolution of Al alloys followed by online ICP-OES determination were examined.
6

Dissolução eletrolítica de ligas de alumínio em cavacos e determinação dos elementos constituintes por espectrometria de emissão atômica com fonte de pasma (ICP-OES) / Electrolytic dissolution of aluminum alloys (Chip form) and multi-element determination by inductively coupled plasma optical emission spectrometry (ICP-OES)

Tânia Grigoletto 20 March 2001 (has links)
Várias ligas de Al em cavacos, com diferentes granulometrias foram dissolvidas de modo convencional, com ataque por água régia. Este tipo de decomposição resulta, muitas vezes, em resíduos sólidos, cujas quantidades dependem dos teores de silício. A fim de se comparar os resultados, procedeuse, com esses resíduos, de dois modos distintos: ou foram desprezados ou foram decompostos com ácido fluorídrico, eliminando-se o silício, dissolvendo-se o restante com ácido nítrico e agrupando-o à primeira solução para a determinação de Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb, Sn, Ti e Zr por ICP-OES. Foi avaliada a influência de quantidades crescentes de Al na determinação destes elementos e, também, a provável interferência espectral de Cu na determinação do Zn (com e sem separação eletrolítica de Cu). A dissolução eletrolítica de ligas de alumínio em cavacos foi estudada pressionando-os contra um eletrodo de platina para que se comportassem como se fossem o próprio ânodo e a eletrólise ocorresse. Uma célula foi construída utilizando-se um tubo (corpo de seringa de 2,5 mL) com perfurações ao redor da base aberta, onde foi colocada uma malha sintética (perlon) no fundo e, sobre esta, a amostra. Na parte superior foi introduzido um pequeno tarugo de acrílico com um fio de platina passando pelo seu interior e com um orifício por onde passava o fluxo (4,5 mL min.-1) da solução eletrolítica (ácido nítrico diluído). Na extremidade inferior, prendeu-se, com o fio, uma plaquinha, também de platina, que pressionava a amostra. A solução saía pelos orifícios inferiores para um béquer de onde era recirculada e onde estava colocado o cátodo, um fio de Pt (de forma de losango), sendo novamente captada e introduzida na parte superior do tarugo do ânodo. Com esse circuito, foram obtidos bons resultados utilizando-se ácido nítrico 1 mol L-1, corrente de 0,6A e tempo de eletrólise de 10 minutos. Sendo a dissolução parcial, é necessário que se conheçam as porcentagens dos elementos por dissolução ácida total de uma liga de composição similar ou por um material de referência certificado. Normalizaram-se os dados pelas porcentagens conhecidas dos constituintes das ligas. Compararam-se os cálculos feitos dos seguintes modos: 1-) pela razão entre a concentração do elemento com a do Al, também determinada; 2-) pela a razão entre a concentração do elemento com a soma das concentrações de todos os elementos determinados, inclusive o Al; 3-) pela razão entre a concentração do elemento e a soma das concentrações só dos outros elementos, sem o Al. O desvio padrão e o erro relativo para os elementos Fe, Cu, Mg, Ni e Cr, quando em teores > 0,1%, foram < 10%; para teores de Zn < 0,2%, foram menores de 10% e para teor de 4,8% foram < 15%. Já para o Mn, quando em teor > 0,2% foram <10% (exceto para a liga B.C.S.268/1). O desvio padrão relativo para o Zr, com teor ao redor de 0,002% foi <10%. Os resultados para o elemento Pb nas ligas B.C.S. 216/1 e 380 tiveram desvio padrão e erro relativo <10%, mas o mesmo não ocorreu na liga B.C.S. 268/1. O elemento Sn apresentou resultados piores, ao redor de 20%. O elemento Ti só deu bons resultados quando em teor de cerca de 0,2%. Para estas determinações foram avaliadas as dissoluções químicas dos metais nas ligas pelo ácido nítrico em diferentes concentrações e temperaturas. Além disso, foram avaliadas duas outras células para a verificação da possibilidade de dissolução eletrolítica das ligas de Al on-line com a determinação por ICP-OES. / Several aluminum alloys with different chips size were dissolved using aqua regia (HCl:HNO3,3:1). The residues of the dissolution procedure were either rejected or used in silicon volatilization with hydrofluoric acid before determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb, Sn, Ti and Zr by ICP-OES. The influence caused by crescent amounts of aluminum in the determination of other elements and the probable spectral interference by Cu in determination of Zn (with or without electrolytic separation of Cu) was evaluated. The electrolytic dissolution of aluminum alloys was performed by pressing chips against a platinum electrode for the electrolysis to occur, so that way the chips behaved as the anode. A tube (body of syringe of 2.5mL) with perforations around the open base was used to contain the sample and Pt electrode. The alloy was placed on synthetic wool (perlon) in this tube. An acrylic dowel with a platinum wire across its interior was fixed in the superior part a tube with Teflon film, with an orifice through which the electrolytic solution flowed (HNO3 1 mol L-1; 4.5mL min-1). A platinum dish was fixed at the inferior extremity of the platinum wire to press the sample. The solution came out through the inferior orifices of the tube to a flask, from where it was again captured (with a peristaltic pump) to go into the superior part of the tube. In this flask, a Pt wire cathode was also placed. A current of 0,6A and ten minutes of electrolysis provided good results. Due to the partial dissolution, the knowledge of percentages of previous elements analyzed after total dissolution, or using certified reference material are necessary. The results were normalized by known percentages. The calculations were made by: 1-) the ratio between the concentration of the element determind, with the determined concentration of aluminum; 2-) the ratio between concentration of the element and the sum of the concentrations of the elements determined, including Al; 3-) the ratio between the concentration of element and the sum of the concentrations of the elements determined, without the aluminum. The relative standard deviations and accuracy were <10% for the elements Fe, Cu, Mg, Ni and Cr when the concentrations were >0.1%; for the Zn were 15%, when the concentration >0.2%, and <10% for concentration <0.2%. For Ti with concentration of about 0.1%, were 15%. Relative standards deviations for the Zr, with concentration of 0.002%, were always <10%. The element Pb, Sn and Mn didnt provide good results. For these determinations, the chemical dissolution of the elements with different nitric acid concentrations and temperature was evaluated. Two other cells for the electrolytic dissolution of Al alloys followed by online ICP-OES determination were examined.

Page generated in 0.0631 seconds