• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un polarimètre de Mueller à codage spectral utilisant une Swept-source : application à la microscopie à balayage laser / Development of a spectral encoding Mueller polarimeter using a swept-source : application to laser scanning microscopy

Le Gratiet, Aymeric 14 December 2016 (has links)
La polarimétrie de Mueller est une technique optique qui mesure la réponse polarimétrique complète d’un milieu sous la forme d’une seule matrice de Mueller afin de remonter à ses propriétés optiques comme le dichroïsme, la biréfringence et la dépolarisation. Le couplage avec la microscopie non-linéaire (SHG par exemple) permet d’avoir accès à des informations précises sur un milieu biologique (structure, organisation, . . .). Cela impose de passer à une modalité d’imagerie à balayage laser, qui nécessite de mesurer la réponse polarimétrique du milieu pixel-par-pixel en des temps relativement courts (de l’ordre de la microseconde). Le but de cette thèse est de mettre en oeuvre un polarimètre de Mueller dont les cadences d’acquisition sont compatibles avec l’imagerie à balayage laser. Dans un premier temps, un polarimètre de Mueller inédit est proposé, basé sur le codage spectral de la polarisation dont toute l’information polarimétrique de l’échantillon est mesurée sous la forme d’un seul signal d’intensité en un temps record (10 μs). Ce dispositif est constitué d’une source à balayage rapide en longueur d’onde à 100 kHz (ou swept-source), de lames de phase d’ordre élevé et d’un détecteur monocanal. Les erreurs systématiques qui entachent la mesure sont évaluées et des méthodes de correction permettent de les prendre en compte dans une étape d’étalonnage qui utilise la réponse de deux milieux étalons.Ensuite, le polarimètre est implémenté dans un microscope commercial à balayage laser, utilisé initialement pour réaliser de l’imagerie non-linéaire (SHG). Cela requiert un redimensionnement du montage, ainsi que la synchronisation entre les deux systèmes. Par ailleurs, un protocole de calibration du dispositif est développé et permet de tenir compte de l’ensemble des erreurs systématiques du polarimètre indépendamment des anisotropies optiques engendrées par le microscope. Enfin, les premières images polarimétriques de Mueller en microscopie à balayage laser ont été acquises sur des échantillons inhomogènes spatialement (rubans adhésifs et cristaux de roches). La potentialité de la microscopie multimodale est démontrée sur des échantillons de fibroses de foie, en couplant l’imagerie polarimétrique de Mueller et la microscopie non-linéaire au sein d’un seul instrument. / Mueller polarimetry is an optical technique allowing the acquisition of the full polarimetric signature of a medium with a single Mueller matrix, and leading to its polarimetric parameters such as dichroism, birefringence and depolarization. Coupling Mueller polarimetry with nonlinear microscopy techniques (SHG for example), more precise information about the medium could be obtained (structure, organization . . .). This imaging technique uses a laser scanning system to measure the Mueller matrix of a medium point-to-point quickly (of the order of the microsecond). The aim of this thesis is to develop a Mueller polarimeter compatible with the laser scanning system. First, a new Mueller polarimeter is proposed using spectral encoding of the polarization and measuring the full polarimetric signature of a sample with a single channeled spectrum in a fast way (10 μs). This setup is composed of a 100 kHz swept-source laser, high order retarders and a single channel detector. Systematic errors on the Mueller matrix measurement are evaluated and correction methods take into account these errors in a calibration step that uses polarimetric signature of two references medium. Then, the polarimeter is implemented on a commercial laser scanning microscope that usually images non-linear contrasts (SHG). The update needs to reduce the dimension of the polarimeter and ensure an electronic synchronization between these two systems. However, a new calibration step is proposed and takes into account all the systematic errors of the polarimeter, independently of the optical anisotropy induced by the microscope. Finally, the images with the first Mueller scanning microscope are obtained with spatially inhomogeneous samples (cellophane tapes, rocks). The potentiality of the multimodal scanning microscopy Mueller/SHG on the same instrument is demonstrated in the case of hepatic fibrosis.
2

Conception d’un dispositif de caractérisation polarimétrique de Mueller à travers une fibre optique endoscopique, destiné à l’imagerie biomédicale avancée / Novel device designed for endoscopic Mueller polarimetry through an optical fiber, for advanced biomedical imaging

Vizet, Jeremy 18 September 2015 (has links)
En fournissant des informations précieuses sur la structuration des tissus biologiques à l'échelle submicronique, les techniques d'imagerie polarimétrique optique peuvent aider au diagnostic précoce de diverses pathologies comme des fibroses ou certains cancers. Parmi ces techniques, la polarimétrie de Mueller est la plus complète puisqu'elle permet de déterminer toutes les caractéristiques polarimétriques d'une cible d'intérêt (retard de phase, diatténuation, dépolarisation). Les travaux effectués dans le cadre de cette thèse visent à coupler, pour la première fois, la polarimétrie de Mueller à un déport endoscopique de la lumière par fibre optique pour permettre de caractériser des tissus in vivo in situ et limiter ainsi le recours aux biopsies. Le défi à relever consiste à s'affranchir des perturbations incontrôlables que la fibre introduit sur les états de polarisation de la lumière guidée. Pour ce faire, on propose d'extraire les caractéristiques polarimétriques de l'échantillon d'intérêt à partir des mesures des matrices de Mueller de la fibre seule (longueur 2m) d'une part, de l'ensemble « fibre + échantillon » d'autre part, associées à un traitement mathématique spécifique. Pour la mise en oeuvre de cette solution, un polarimètre de Mueller à fibre, fonctionnant en réflexion, a été conçu spécialement. Deux déclinaisons, avec des mesures soit séquentielles soit simultanées, ont été explorées et comparées. Les mesures ponctuelles de composants polarimétriques calibrés, seuls ou combinés, sont en très bon accord avec les valeurs attendues : erreurs inférieures à 1,5° sur les retards de phase, à 1° sur les orientations relatives des axes de biréfringence, et à 0,02 sur les diatténuations linéaire et circulaire. Les premières images polarimétriques de Mueller d'échantillons manufacturés et biologiques (collagène de type I), réalisées à travers une fibre optique endoscopique, sont également présentées et commentées. / Optical polarimetric imaging techniques can be very attractive for early diagnosis of diseases such as fibrosis or some cancers as they can provide valuable information on the structure of biological tissues at the submicronic scale. Among them, Mueller polarimetry is the only one able to determine all the polarimetric characteristics of any sample (retardance, diattenuation, depolarization). This PhD thesis aims to achieve, for the first time, Mueller polarimetry through an optical fiber in order to allow in vivo in situ characterizations of biological tissues. The challenge is to overcome the uncontrollable perturbations induced by the optical fiber on the polarization states of the guided light. The investigated solution consists in deducing the polarimetric characteristics of the sample from the Mueller matrix of the fiber only (2 m long), and from that of the « fiber + sample » assembly, thanks to a specific mathematical processing. A fibered Mueller polarimeter, working in backscattering configuration has been specially designed. Two versions, based on either sequential or simultaneous measurements, were investigated and compared. Measurements of different sets of calibrated polarimetric components are in a very good agreement with the expected ones: discrepancies lower than 1.5°, 1° and 0.02 respectively have been found on retardance, relative orientations of birefringence eingenaxes and on linear and circular diattenuations. Very first Mueller polarimetric images of manufactured and biological samples (type I collagen) realized through an endoscopic optical fiber are also shown and discussed.

Page generated in 0.0623 seconds