• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de eficiência de biopolímero como composto coadjuvante no processo de coagulação-floculação e sedimentação / Biopolymer efficiency analysis as a coadjuvant compound in the coagulation-flocculation and sedimentation process

Andrade, Erik de Lima [UNESP] 09 February 2017 (has links)
Submitted by Erik de Lima Andrade null (erik_andrade88@hotmail.com) on 2017-03-06T18:12:25Z No. of bitstreams: 1 Dissertação_Erik de Lima Andrade.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-03-10T14:43:15Z (GMT) No. of bitstreams: 1 andrade_el_me_soro.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5) / Made available in DSpace on 2017-03-10T14:43:15Z (GMT). No. of bitstreams: 1 andrade_el_me_soro.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5) Previous issue date: 2017-02-09 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A adequação no tratamento da água, para abastecimento público envolve a compreensão da vulnerabilidade de mananciais e de situações de risco à saúde humana. Da mesma forma, o sucesso do tratamento de água de superfície depende, fortemente, da eficácia do desempenho do coagulante. Com a qualidade dos mananciais comprometida por diferentes cenários, tornase indispensável, o processo de desenvolvimento de abordagens eficazes para as questões de caráter econômico e ambiental. O tratamento de água de superfície objetiva, de modo geral, a remoção de impurezas com o propósito de enquadrá-la no padrão de potabilidade, essencialmente, através do uso de produtos químicos. Neste sentido, o presente trabalho analisou a eficiência de três produtos comerciais: sulfato de alumínio, policloreto de alumínio e PGα21Ca. Para tanto, foram realizados ensaios de coagulação-floculação e sedimentação, em água da ETA de Salto de Pirapora, São Paulo, Brasil. Os resultados obtidos do PGα21Ca revelam caráter, essencialmente, inorgânico, com teores elevados de sulfato de cálcio (87%) e 5% de ácido γ-poliglutâmico, entre outros compostos químicos. O PGα21Ca apresentou maior eficiência de remoção de turbidez e cor aparente, com valores de 1,93 NTU de turbidez remanescente e 96,89% de remoção de cor aparente e pouca alteração no pH do meio, demonstrando efetividade para o tratamento de água para abastecimento público. O PAC apresentou resultados inferiores para clarificação da água quando comparado ao PGα21Ca e melhores resultados quando comparado ao sulfato de alumínio. Utilizando-se o PGα21Ca em água de Rio Grande, não obtém-se resultados tão expressivos quando comparado a água da ETA de Salto de Pirapora. / The suitability in the treatment of water for public supply involves understanding the vulnerability of sources and situations of risk to human health. Similarly, the success of surface water treatment depends strongly on the effectiveness of the coagulant performance. With the quality of water sources compromised by different scenarios, it is essential to the effective approaches development process for the economic and environmental character issues. The water treatment lens surface generally the removal of impurities in order to fit it in potable standard, mainly through the use of chemicals. In this sense, the present study examined the effectiveness of three commercial products: aluminum sulphate, polyaluminum chloride and PGα21Ca. Therefore, tests were carried out coagulation-flocculation and sedimentation in water of Salto de Pirapora WTP, São Paulo, Brazil. The results obtained reveal the character PGα21Ca essentially inorganic, with high levels of calcium sulfate (87%) and 5% γ-polyglutamic acid, and other chemical compounds. The PGα21Ca showed higher turbidity and apparent color removal efficiency, with values of 1.93 NTU turbidity and remaining 96.89% removal of apparent color and little change in pH of the medium, demonstrating the effectiveness for water treatment. The PAC presented lower results for clarification of water when compared to PGα21Ca and better results when compared to aluminum sulfate. Using PGα21Ca in Rio Grande water did not obtain significant results when compared to the water of the Salto de Pirapora WTP. / FAPESP: 2015/02650-8
2

Avaliação de diferentes coagulantes para remoção de sólidos por flotação e sedimentação de água residuária de uma indústria metal-mecânica / Evaluation of different coagulants for removal of solids by flotation and sedimentation of wastewater from a metal-mechanic industry

Lopes, Marcelo Almir 09 December 2011 (has links)
Uma das abordagens para minimizar o volume de captação de água potável e o descarte de efluentes é o reuso da água dentro da unidade industrial através de técnicas avançadas de tratamento como o sistema de osmose reversa, porém esse sistema exige um afluente com uma baixa quantidade de sólidos, além de outros requisitos. A água residuária utilizada nesse estudo é proveniente de uma empresa do ramo metal-mecânico que utiliza processos de coagulação-floculação-sedimentação como forma de remover os sólidos antes de um sistema de osmose reversa. A proposta deste trabalho foi avaliar três diferentes coagulantes (aluminato de sódio, cloreto férrico e uma mistura de dois coagulantes comerciais, Procytrat 100A e Procytrat 300) em processos de coagulação-floculação e separação de sólidos da fase líquida por sedimentação e flotação por ar dissolvido e também comparar os custos aproximados dos processos envolvidos. Foram realizados ensaios em testes de jarros e flotateste e com os dados obtidos construíram-se diagramas de coagulação-floculação e escolhidas as regiões de maior remoção de sólidos. Através das regiões escolhidas, foram feitas as comparações de eficiência de remoção e custos para cada coagulante estudado. Verificou-se que os diagramas de coagulação-floculação-sedimentação foram os que apresentaram as regiões de maior área com turbidez remanescente menor que 2%, principalmente para os coagulantes cloreto férrico e a mistura Procytrat 100A + Procytrat 300, chegando a alcançar valores próximos a 0,5%. A opção mais econômica foi alcançada com custo de cloreto férrico, na dosagem de 200 mg/L, pH igual a 8,3 e turbidez remanescente igual a 0,6%, de R$0,47/\'M POT.3\' de água tratada. Os diagramas de coagulação-floculação-flotação apresentaram regiões de turbidez remanescente com áreas bem mais reduzidas se comparadas aos diagramas de coagulação-floculação-sedimentação, sendo que não foram atingidos valores de turbidez remanescente menores que 1,5%. Os menores valores de turbidez remanescente para o processo de flotação foram encontrados utilizando-se como coagulante a mistura Procytrat 100A + Procytrat 300, sendo a opção mais econômica alcançada para pH igual a 3,3, dosagem de 60 mg/L e turbidez remanescente igual a 1,6%, com custo de R$0,33/\'M POT.3\' de água tratada. De um modo geral, para todos os coagulantes testados, as regiões escolhidas nos diagramas de coagulação-floculação-flotação, cujos valores de turbidez remanescente foram menores, estavam concentradas em valores de pH baixos (3,2 a 5,5), dosagens de coagulante reduzidas (10 a 80 mg/L) e dosagens de alcalinizante também reduzidas (0 a 60 mg/L de Ca(\'OH)IND.2\'). Esse comportamento foi contrário ao apresentado pelos diagramas coagulação-floculação-sedimentação cujos valores de turbidez remanescente foram menores em valores de pH mais altos (6,5 a 8,5), maiores dosagens de coagulante (40 a 380 mg/L) e altas dosagens de alcalinizante (100 a 400 mg/L de Ca(\'OH)IND.2\'). / One approach to minimize the consumption of drinking water and effluent disposal is the reuse of water within the plant through advanced treatment techniques such as reverse osmosis system, however, this system requires an affluent with a low amount of solids and other requirements. The wastewater used in this study comes from a metalworking company that uses coagulation-flocculation-sedimentation process as a way to remove the solids before a reverse osmosis system. The purpose of this study was to evaluate three different coagulants (sodium aluminate, ferric chloride and a mixture of two commercial coagulants, Procytrat 100A and Procytrat 300) in the process of coagulation-flocculation and separation of solids from the liquid phase by sedimentation and dissolved air flotation and also compare the approximate costs of the processes involved. Jar tests and flotatests were performed and the coagulation-flocculation diagrams were built. In the coagulation-flocculation diagrams were selected areas of higher solids removal. Through the chosen regions, comparisons were made of removal efficiency and cost study for each coagulant. It was found that the diagrams of coagulation-flocculation-sedimentation presented the areas of higher turbidity remaining area with less than 2%, mainly for the coagulants ferric chloride and the mixture Procytrat 100A + Procytrat 300, reaching values close to 0.5 %. The most economical option was achieved at a cost of ferric chloride at a dosage of 200 mg/L, pH 8.3, and the remaining turbidity equal to 0.6%, from R$ 0.47/\'M POT.3\' treated water. The diagrams of coagulation-flocculation-flotation showed regions with turbidity remaining areas much reduced compared to the diagrams of coagulation-flocculation-sedimentation, and the turbidity remaining values were more than 1.5%. The lower values of turbidity remaining for the flotation process were found using the mixture Procytrat 100A + Procytrat 300, and the most economical option was reached for a pH of 3.3, dosage of 60 mg/L and remaining turbidity equal to e 1.6%, at a cost of R$ 0.33/\'M POT.3\' of treated water. In general, for all coagulants tested, the selected regions in the diagrams of coagulation-flocculation-flotation, whose remaining turbidity values were lower, were concentrated in low pH values (3.2 to 5.5), dosages of coagulant reduced (10 to 80 mg/L) and dosages of alkaline also reduced (0 to 60 mg/L of Ca(\'OH)IND.2\'). This behavior was contrary to the diagrams presented by coagulation-flocculation-sedimentation whose remaining turbidity values were lower in higher pH values (6.5 to 8.5), larger amounts of coagulant (40 to 380 mg/L) and high doses of alkaline (100 to 400 mg/L Ca(\'OH)IND.2\').
3

Avaliação de diferentes coagulantes para remoção de sólidos por flotação e sedimentação de água residuária de uma indústria metal-mecânica / Evaluation of different coagulants for removal of solids by flotation and sedimentation of wastewater from a metal-mechanic industry

Marcelo Almir Lopes 09 December 2011 (has links)
Uma das abordagens para minimizar o volume de captação de água potável e o descarte de efluentes é o reuso da água dentro da unidade industrial através de técnicas avançadas de tratamento como o sistema de osmose reversa, porém esse sistema exige um afluente com uma baixa quantidade de sólidos, além de outros requisitos. A água residuária utilizada nesse estudo é proveniente de uma empresa do ramo metal-mecânico que utiliza processos de coagulação-floculação-sedimentação como forma de remover os sólidos antes de um sistema de osmose reversa. A proposta deste trabalho foi avaliar três diferentes coagulantes (aluminato de sódio, cloreto férrico e uma mistura de dois coagulantes comerciais, Procytrat 100A e Procytrat 300) em processos de coagulação-floculação e separação de sólidos da fase líquida por sedimentação e flotação por ar dissolvido e também comparar os custos aproximados dos processos envolvidos. Foram realizados ensaios em testes de jarros e flotateste e com os dados obtidos construíram-se diagramas de coagulação-floculação e escolhidas as regiões de maior remoção de sólidos. Através das regiões escolhidas, foram feitas as comparações de eficiência de remoção e custos para cada coagulante estudado. Verificou-se que os diagramas de coagulação-floculação-sedimentação foram os que apresentaram as regiões de maior área com turbidez remanescente menor que 2%, principalmente para os coagulantes cloreto férrico e a mistura Procytrat 100A + Procytrat 300, chegando a alcançar valores próximos a 0,5%. A opção mais econômica foi alcançada com custo de cloreto férrico, na dosagem de 200 mg/L, pH igual a 8,3 e turbidez remanescente igual a 0,6%, de R$0,47/\'M POT.3\' de água tratada. Os diagramas de coagulação-floculação-flotação apresentaram regiões de turbidez remanescente com áreas bem mais reduzidas se comparadas aos diagramas de coagulação-floculação-sedimentação, sendo que não foram atingidos valores de turbidez remanescente menores que 1,5%. Os menores valores de turbidez remanescente para o processo de flotação foram encontrados utilizando-se como coagulante a mistura Procytrat 100A + Procytrat 300, sendo a opção mais econômica alcançada para pH igual a 3,3, dosagem de 60 mg/L e turbidez remanescente igual a 1,6%, com custo de R$0,33/\'M POT.3\' de água tratada. De um modo geral, para todos os coagulantes testados, as regiões escolhidas nos diagramas de coagulação-floculação-flotação, cujos valores de turbidez remanescente foram menores, estavam concentradas em valores de pH baixos (3,2 a 5,5), dosagens de coagulante reduzidas (10 a 80 mg/L) e dosagens de alcalinizante também reduzidas (0 a 60 mg/L de Ca(\'OH)IND.2\'). Esse comportamento foi contrário ao apresentado pelos diagramas coagulação-floculação-sedimentação cujos valores de turbidez remanescente foram menores em valores de pH mais altos (6,5 a 8,5), maiores dosagens de coagulante (40 a 380 mg/L) e altas dosagens de alcalinizante (100 a 400 mg/L de Ca(\'OH)IND.2\'). / One approach to minimize the consumption of drinking water and effluent disposal is the reuse of water within the plant through advanced treatment techniques such as reverse osmosis system, however, this system requires an affluent with a low amount of solids and other requirements. The wastewater used in this study comes from a metalworking company that uses coagulation-flocculation-sedimentation process as a way to remove the solids before a reverse osmosis system. The purpose of this study was to evaluate three different coagulants (sodium aluminate, ferric chloride and a mixture of two commercial coagulants, Procytrat 100A and Procytrat 300) in the process of coagulation-flocculation and separation of solids from the liquid phase by sedimentation and dissolved air flotation and also compare the approximate costs of the processes involved. Jar tests and flotatests were performed and the coagulation-flocculation diagrams were built. In the coagulation-flocculation diagrams were selected areas of higher solids removal. Through the chosen regions, comparisons were made of removal efficiency and cost study for each coagulant. It was found that the diagrams of coagulation-flocculation-sedimentation presented the areas of higher turbidity remaining area with less than 2%, mainly for the coagulants ferric chloride and the mixture Procytrat 100A + Procytrat 300, reaching values close to 0.5 %. The most economical option was achieved at a cost of ferric chloride at a dosage of 200 mg/L, pH 8.3, and the remaining turbidity equal to 0.6%, from R$ 0.47/\'M POT.3\' treated water. The diagrams of coagulation-flocculation-flotation showed regions with turbidity remaining areas much reduced compared to the diagrams of coagulation-flocculation-sedimentation, and the turbidity remaining values were more than 1.5%. The lower values of turbidity remaining for the flotation process were found using the mixture Procytrat 100A + Procytrat 300, and the most economical option was reached for a pH of 3.3, dosage of 60 mg/L and remaining turbidity equal to e 1.6%, at a cost of R$ 0.33/\'M POT.3\' of treated water. In general, for all coagulants tested, the selected regions in the diagrams of coagulation-flocculation-flotation, whose remaining turbidity values were lower, were concentrated in low pH values (3.2 to 5.5), dosages of coagulant reduced (10 to 80 mg/L) and dosages of alkaline also reduced (0 to 60 mg/L of Ca(\'OH)IND.2\'). This behavior was contrary to the diagrams presented by coagulation-flocculation-sedimentation whose remaining turbidity values were lower in higher pH values (6.5 to 8.5), larger amounts of coagulant (40 to 380 mg/L) and high doses of alkaline (100 to 400 mg/L Ca(\'OH)IND.2\').

Page generated in 0.0707 seconds