• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution à l'étude du transfert des polluants gazeux entre le sol et les environnements intérieurs des bâtiments

Abdelouhab, Malya 04 July 2011 (has links) (PDF)
Les outils d'évaluation des risques liés au transfert des polluants gazeux du sol vers les environnements intérieurs comportent de fortes incertitudes quant à la connaissance de certains paramètres et notamment ceux relatifs à l'interface sol-bâtiment : prise en compte des différentes typologies de soubassement, niveau de perméabilité des planchers bas. Ces incertitudes conduisent à une mauvaise estimation de l'impact de ces polluants gazeux sur la qualité d'air intérieur.Afin de contribuer à l'amélioration des modèles d'évaluation pour la gestion des risques vis-à-vis des pollutions gazeuses venant du sol, cette thèse présente dans une première partie, une méthodologie de développement de modèles analytiques adaptés à la prise en compte de différents soubassements, afin de mieux appréhender le transfert de polluants gazeux entre le sol et le bâtiment. Ces modèles ont été développés sur la base d'une analogie avec le transfert des flux de chaleur entre le sol et le bâtiment. Ils traitent, tout particulièrement, des transferts d'air convectifs au niveau de l'interface sol-bâtiment pour différentes typologies de soubassement. Parla suite, les modèles analytiques développés ont été intégrés dans un modèle aéraulique des bâtiments afin d'étudier l'impact des différentes typologies de soubassement sur l'entrée de polluants du sol et donc sur la qualité d'air intérieur résultante.En parallèle, des travaux expérimentaux ont été entrepris afin de compléter la connaissance actuelle relative à la perméabilité à l'air des bétons fissurés, pour laquelle un manque de données a été constaté. D'autre part, les débits d'air convectifs allant du sol vers le bâtiment ont également été quantifiés de façon expérimentale à l'aide de la maison expérimentale 'MARIA' dont dispose le CSTB. Ce type de quantification constitue une première base de données expérimentale.Enfin, une dernière partie de cette thèse traite de la réalisation d'un suivi expérimental annuel des performances d'un Système de Dépressurisation des Sols naturels, dans le but d'optimiser à terme les solutions de protection des bâtiments vis-à-vis des polluants gazeux du sol..
2

Contribution à l’étude du transfert des polluants gazeux entre le sol et les environnements intérieurs des bâtiments / Contribution to the study of gaseous pollutants transfer between soil and indoor environments of buildings

Abdelouhab, Malya 04 July 2011 (has links)
Les outils d’évaluation des risques liés au transfert des polluants gazeux du sol vers les environnements intérieurs comportent de fortes incertitudes quant à la connaissance de certains paramètres et notamment ceux relatifs à l’interface sol-bâtiment : prise en compte des différentes typologies de soubassement, niveau de perméabilité des planchers bas. Ces incertitudes conduisent à une mauvaise estimation de l’impact de ces polluants gazeux sur la qualité d’air intérieur.Afin de contribuer à l’amélioration des modèles d’évaluation pour la gestion des risques vis-à-vis des pollutions gazeuses venant du sol, cette thèse présente dans une première partie, une méthodologie de développement de modèles analytiques adaptés à la prise en compte de différents soubassements, afin de mieux appréhender le transfert de polluants gazeux entre le sol et le bâtiment. Ces modèles ont été développés sur la base d’une analogie avec le transfert des flux de chaleur entre le sol et le bâtiment. Ils traitent, tout particulièrement, des transferts d’air convectifs au niveau de l’interface sol-bâtiment pour différentes typologies de soubassement. Parla suite, les modèles analytiques développés ont été intégrés dans un modèle aéraulique des bâtiments afin d’étudier l’impact des différentes typologies de soubassement sur l’entrée de polluants du sol et donc sur la qualité d’air intérieur résultante.En parallèle, des travaux expérimentaux ont été entrepris afin de compléter la connaissance actuelle relative à la perméabilité à l’air des bétons fissurés, pour laquelle un manque de données a été constaté. D’autre part, les débits d’air convectifs allant du sol vers le bâtiment ont également été quantifiés de façon expérimentale à l’aide de la maison expérimentale ‘MARIA’ dont dispose le CSTB. Ce type de quantification constitue une première base de données expérimentale.Enfin, une dernière partie de cette thèse traite de la réalisation d’un suivi expérimental annuel des performances d’un Système de Dépressurisation des Sols naturels, dans le but d’optimiser à terme les solutions de protection des bâtiments vis-à-vis des polluants gazeux du sol.. / Risk assessment tools related to transfers of gaseous pollutant from soil to indoor environments present large uncertainties relative to the knowledge of certain parameters, particularly those relating to the soil-building interface: considering the different basement typology, permeability level of floor. These uncertainties lead to an inaccurate evaluation of the impact of gaseous pollutants on indoor air quality.In order to contribute to the improvement of risk assessment models of gaseous pollutants from the soil, thiswork present in a fist part the development of analytical and numerical models. These models have been adapted to consider the different basement, in order to estimate the transfer of gaseous pollutants from the soil to the building. An analogy with heat transfer phenomena between soil and building is used to develop these models.They predict convective airflow transfers between soils and building, for different soil-building interface.There after, the analytical model has been incorporated into an airflow model. This model enables us to study the impact of different types of basement on the entry of pollutants from soil and the indoor air quality.Besides, experimental works have been made to complete the knowledge of concrete air permeability, because of a lack of data. Furthermore, the convective airflows from soil to building have been quantified experimentally.These airflows have been determined in the experimental house ‘MARIA’ installed in the CSTB. Suchquantification constitutes the first experimental database.Finally, the last part of this work shows a one-year follow-up study about the ability of natural SoilDepressurisation System. This study has been carried out to optimize the solutions of buildings protection from the soil gaseous pollutants.
3

Impact des polluants gazeux du sol sur la qualité de l'air intérieur des bâtiments / Impact of soil gas pollutants on indoor air quality

Diallo, Thierno Mamadou Oury 10 October 2013 (has links)
L’entrée des polluants gazeux du sol (Radon, COV,…) dans les environnements intérieurs peut occasionner des risques sanitaires significatifs. Or les modèles d’évaluation de risques sanitaires liés à ces polluants gazeux du sol contiennent beaucoup d’incertitudes qui peuvent conduire à une mauvaise appréciation des risques. Dans un premier temps, cette thèse contribue à l’amélioration des modèles d’évaluation des risques. Dans un second temps, elle propose le développement d’un modèle de dimensionnement des Systèmes de Dépressurisation du Sol (SDS) passifs utilisés pour protéger les bâtiments des pollutions gazeuses venant du sol. L’amélioration des modèles a porté sur la prise en compte des principaux phénomènes de convection et diffusion à l’interface entre le sol et le bâtiment, en tenant compte des différentes typologies de soubassement. La première contribution porte sur le développement de modèles analytiques fournissant les débits d’air dus à la convection à travers le sol pour différents types de soubassement : dallage indépendant, dalle portée, vide sanitaire et cave. Les bâtiments avec des murs enterrés et les soubassements avec un lit de gravier sous le plancher bas sont également traités. Une méthodologie permettant la prise en compte de la fissuration et des points singuliers du plancher bas est aussi proposée. La deuxième contribution porte sur la prise en compte du transfert couplé des polluants des sols par convection et diffusion auprès des fondations. Une étude numérique a permis une meilleure compréhension du comportement des polluants à l’interface sol/bâtiment. Sur la base de cette compréhension, des lois semi-empiriques d’estimation des flux d’entrée de polluant dans les bâtiments sont proposées. Les différents modèles développés ont été validés numériquement avec un modèle CFD et expérimentalement avec des données issues de la littérature. La confrontation de ces modèles avec ceux existants a montré les améliorations apportées. L’impact de la typologie du soubassement sur le transfert de polluants gazeux des sols a été constaté. Une première application des modèles est illustrée par leur intégration dans un code de simulation thermo-aéraulique multizone afin de pouvoir étudier l’impact de ces polluants sur la qualité de l’air intérieur. Ce travail se termine par le développement d’un modèle de dimensionnement des Systèmes de Dépression du Sol (SDS) passifs. Ce modèle aéraulique de dimensionnement des SDS a été validé par des mesures effectuées au CSTB dans une maison expérimentale. Les premières applications du modèle de dimensionnement portent notamment sur l’impact de la météorologie (vent et tirage thermique) sur le fonctionnement du SDS passif et sur l’impact des stratégies de ventilation du bâtiment sur le fonctionnement du SDS passif. On voit ainsi l’intérêt de l’utilisation d’un tel modèle pour tester l’aptitude de ce système de protection des bâtiments dans des situations environnementales données. / Transfer of soil gas pollutants (Radon, VOC) into buildings can cause significant health risks. However, analytical models used today to estimate health risks associated with these pollutants contain many uncertainties which can lead to poor risk assessment. Initially, the main objective of this thesis is to contribute to the improvement of these models for risk assessment. Secondly, we propose the development of air flow model for passive Sub slab Depressurization Systems (SDS) design used to protect buildings. The improvement of models focused on the inclusion of the main phenomena of convection and diffusion at building/soil interface, taking into account different types of building substructures. The first improvement concerns the assessment of convection phenomenon through the development of analytical models to quantify air flow rates entering through many kinds of building substructures: floating slab, bearing slab, crawl space and basement. Buildings with buried walls and substructures with a sub slab gravel layer are also treated. A methodology taking into account the presence of cracks, holes and singular leakages of the slab is also proposed. The second improvement of the models is the inclusion of coupled transfer of convection and diffusion near foundations. A numerical study allowed a better understanding of the behavior of pollutants at soil / building interface. Based on this understanding, semi-empirical laws for estimating soil gas pollutants entry rate into buildings are proposed. The various models developed have been validated numerically using a CFD model and experimentally with data from the literature when available. The impact of building substructure on pollutant transfer has been highlighted. A first application of the model is illustrated by their integration into a multizone simulation code to study the impact of these transfers on indoor air quality. Finally, the work ends with the development of a model for designing passive sub slab depressurization systems. The design model developed is validated with in situ experimental data. Preliminary applications using this model focused at first on the impact of meteorological conditions (stack effect, wind) on the sub slab system running. At second, the impact of ventilation strategies on sub slab depressurization performance is studied. Thus, we see the potential interest of this model to test the effective running of passive sub slab depressurization systems in given configuration.

Page generated in 0.0947 seconds