Spelling suggestions: "subject:"copolymer cotensor"" "subject:"copolymer condensor""
1 |
Novel spectroscopic studies of heterogeneous chemistry at interfacesBunker, Ian January 1999 (has links)
No description available.
|
2 |
Fabrication and optimization of a sensor array for incipient grain spoilage monitoringHossain, Md. Eftekhar 10 September 2010 (has links)
During storage of grain, there may have significant damage to its quality due to unfavorable physical and biological interactions and thus requires continuous monitoring. Therefore, an easy, cost-effective and environmentally friendly method is necessary for efficient monitoring of stored-grain. Arrays of sensors are being used for classifying liquors, perfumes, quality of food products mimicking mammalian olfactory systems. Monitoring of stored grain is a new application of sensor arrays. The main objective was to fabricate a carbon black polymer sensor array which can easily monitor incipient grain spoilage by detecting spoiling stored grain volatiles (benzene derivatives and aliphatic hydrocarbon derivatives) with minimum interference from relative humidity. Various aspects of a good sensor were analyzed using statistical analysis (RSD, LDA, PCA, t-test). The developed sensor array can identify red flour beetle-infected and uninfected wheat and fungal volatiles at ambient conditions as well as some stored grain conditions (MC 16%, RH 52%).
|
3 |
MINIMALLY INVASIVE SURGICAL DEVICES WITH MICRO FORCE SENSORS: A SMART SCALPEL AND DISSECTOR TOOLHADLOCK, NATHANIEL A. January 2006 (has links)
No description available.
|
4 |
Etude et compréhension des mécanismes d’interaction de Composés Organiques Volatils (COV) par des couches polymères : application à la microdétection des polluants des environnements intérieurs / Study and understanding of Volatil Organic Compounds (VOCs) interaction mechanisms on polymer layers : application to the development of micro-sensors for the indoor air pollutionAnton, Rukshala 09 July 2013 (has links)
Les moisissures sont des biocontaminants courants des environnements intérieurs causant la biodégradation des matériaux qu'ils colonisent et favorisant l'apparition de diverses pathologies, notamment respiratoires telles que des allergies, des infections ou des toxi-infections.En raison de ces impacts, la maîtrise de la contamination fongique constitue une préoccupation majeure pour des secteurs aussi divers que les industries agro-alimentaires, pharmaceutiques, les hôpitaux ou encore les établissements patrimoniaux. Actuellement, les techniques utilisées pour surveiller ces environnements sensibles reposent sur la mesure de particules biologiques en suspension dans l'air émises après sporulation des moisissures. Afin de prévenir les effets de la prolifération de moisissures, le Centre Scientifique et Technique du Bâtiment (CSTB) a développé un indice de contamination fongique basé sur la détection de Composés Organiques Volatils (COV) spécifiques émis dès le début de cette croissance microbienne avant même l'émission dans l'air de particules délétères (Moularat, Robine et al. 2008; Moularat, Robine et al. 2008). Cet outil, breveté en 2007 (Moularat 2007), a été employé lors de différentes campagnes de mesures dans l'habitat, les bureaux, les écoles, les crèches, les musées…(Moularat, Derbez et al. 2008; Joblin, Moularat et al. 2010; Moularat, Hulin et al. 2011; Hulin, Moularat et al. 2012). Depuis le CSTB a élaboré un prototype de balise de surveillance intégrant cet indice et constitué de capteurs gaz à base de Polymères Conducteurs Electroniques (PCE), en collaboration avec l'ESIEE Paris (l'Ecole d'Ingénieurs de la Chambre de Commerce et d'Industrie de Paris) (pour la balise) et le Laboratoire de Physico-chimie des Polymères et des Interfaces (LPPI) (pour les PCE). Ainsi des capteurs à base de polypyrrole (PPy) et de Poly-(3,4-éthylènedioxythiophène)-poly(styrènesulfonate) (PEDOT-PSS) ont permis de différencier un environnement contaminé d'un environnement sain. Si ces couches sensibles se sont montrées efficaces pour la détection par l'identification d'une empreinte globale de COV d'origine fongique, elles ne s'avèrent pas encore suffisamment sélectives pour réaliser l'identification de chaque COV, indispensable pour le calcul de l'indice.Dans le cadre de la surveillance de la qualité microbiologique de l'air des environnements intérieurs, cette thèse a pour ambition de prolonger ces travaux en étudiant les mécanismes d'interaction entre COV et PCE en vue de l'application au développement de micro-capteurs chimiques adaptés à la mesure in situ. Cette recherche implique à la fois l'optimisation de la sensibilité et de la sélectivité de ces polymères et le développement d'une matrice de capteurs.Le premier aspect de cette étude a consisté à synthétiser de nouveaux PCE, plus spécifiques sur la base de ceux identifiés comme pertinents lors de la thèse de Joblin en 2011. Ainsi, des polymères, à base de pyrrole fonctionnalisés en position 1 et 3, ont été synthétisés par voie électrochimique. Le PEDOT-PSS, polymère commercial (sous forme de suspension dans l'eau), a, quant-à-lui, été conditionné par différents traitements thermiques.Le second aspect a porté sur l'étude de l'influence de l'exposition des COV à ces PCE sur leurs propriétés physico-chimiques. Ainsi, des caractérisations morphologiques, électrochimiques, optiques ainsi que la variation des propriétés de surface ont permis de mettre en évidence des interactions faibles, en général de type van der Waals ou par liaison hydrogène, entre COV et PCE.Enfin, le dernier aspect a porté sur l'étude expérimentale de la réponse des capteurs en contact avec différents COV issus ou non du métabolisme fongique. Cette dernière étape a permis de vérifier les hypothèses de mécanismes d'interaction. Par ailleurs, la spécificité de la matrice de capteurs vis-à-vis des composés fongiques a été démontrée. Cette matrice de capteurs a également permis d'obtenir des signatures spéci / Conducting polymers can be used as active materials of sensing devices that find application in different areas, such as quality control of products in industries such as food and beverage, cosmetics and solvents, in the monitoring of air quality for environmental and safety purposes, and as an auxiliary tool in the diagnosis of diseases. In spite of this, as a general rule, the details of the prevailing interactions of the volatile compounds and the polymer are not well understood. For this reason, we have focused the work of this thesis on the characterization of the interactions between vapors of volatile organic compounds and thin films of conducting polymers. These films, that were the active components of the sensors, were prepared atop of different geometry of interdigitated electrodes via electropolymerization, where several preparation parameters (such as doping agents nature and concentrations, monomer nature, thermal annealing) were observed to assure an homogeneous growth of the polymeric film. Several characterizations such as electrochemical studies, AFM observations and UV-VIS-NIR spectra studies were used to obtain detailed information about the interaction mechanisms between VOC and conducting polymers. We have also measured the contact angle of water, formamide and diiodomethane deposited on the surface of the polymeric films to evaluate surface free energy (and its acid-base and dispersive components). The selectivity and sensitivity of the polymeric sensors when exposed to different volatile organic compounds (VOCs) have shown to be dependent not only of the properties of the analyzed VOC but also on the nature of the counter-ion used to dope the polypyrrole film. As a final conclusion, we can say that as a result of this work it becomes possible to optimize the design of an arrangement of sensors such that both a better sensitivity and a better selectivity sensitivity to a given chemical environment can be achieved.
|
5 |
Strukturintegrierbare Sensoren auf Basis piezoelektrischer Polymere / Sensors Based on Piezoelectric Polymers for Structure IntegrationSchulze, Robert 07 August 2017 (has links) (PDF)
Die vorliegende Arbeit beschreibt die Entwicklung von Sensoren in einer neuen, großserienfähigen Technologie. Mit dem Mehrkomponentenmikrospritzgießverfahren werden mechanische Sensorstrukturen aus (faserverstärktem) Kunststoff an polymere piezoelektrische Wandler angebunden. Die hergestellten Aufnehmer können über die Weiterverarbeitung mit Hybridtechnologien für die Strukturintegration eingesetzt werden. Diese Dissertation stellt Entwurfsmethoden und Modelle zur Vorausberechnung der neuartigen Sensoren bereit, die zur Qualifizierung der neuen Technologie benötigt werden. Dazu werden bekannte Modellierungsansätze angewandt und wesentliche Erweiterungen für die praktische Nutzung erarbeitet. Entwurfsrelevante technologieabhängige Kenngrößen, wie die elastischen Eigenschaften der verarbeiteten Werkstoffe und die geometrischen Dimensionen der hergestellten Sensorstrukturen werden untersucht und deren Einfluss auf den Entwurfsprozessdargelegt. Die hergestellten Sensoren werden in ihrer Grundfunktion messtechnisch charakterisiert und die System- und Strukturintegration vorgestellt. / The presented work describes the development of sensors in a novel technology approach feasible for large-scale production. By using the multicomponent microinjection molding process, mechanical sensor structures out of (fiber-reinforced) polymers are joined with piezoelectric polymer transducers. The fabricated sensors can be processed further with hybrid manufacturing technologies and adapted for structure integration. This thesis introduces design methods and models for the preliminary calculation of the novel sensors, which are required for a technology qualification. Therefore, existing modelling approaches adapted and essentially extended for practical use. Design relevant parameters related to the technology like the elastic properties of the applied materials or the geometric dimensions of the manufactured sensor structures are characterized and the system and structure integration of the sensors is presented.
|
6 |
Strukturintegrierbare Sensoren auf Basis piezoelektrischer PolymereSchulze, Robert 10 January 2017 (has links)
Die vorliegende Arbeit beschreibt die Entwicklung von Sensoren in einer neuen, großserienfähigen Technologie. Mit dem Mehrkomponentenmikrospritzgießverfahren werden mechanische Sensorstrukturen aus (faserverstärktem) Kunststoff an polymere piezoelektrische Wandler angebunden. Die hergestellten Aufnehmer können über die Weiterverarbeitung mit Hybridtechnologien für die Strukturintegration eingesetzt werden. Diese Dissertation stellt Entwurfsmethoden und Modelle zur Vorausberechnung der neuartigen Sensoren bereit, die zur Qualifizierung der neuen Technologie benötigt werden. Dazu werden bekannte Modellierungsansätze angewandt und wesentliche Erweiterungen für die praktische Nutzung erarbeitet. Entwurfsrelevante technologieabhängige Kenngrößen, wie die elastischen Eigenschaften der verarbeiteten Werkstoffe und die geometrischen Dimensionen der hergestellten Sensorstrukturen werden untersucht und deren Einfluss auf den Entwurfsprozessdargelegt. Die hergestellten Sensoren werden in ihrer Grundfunktion messtechnisch charakterisiert und die System- und Strukturintegration vorgestellt. / The presented work describes the development of sensors in a novel technology approach feasible for large-scale production. By using the multicomponent microinjection molding process, mechanical sensor structures out of (fiber-reinforced) polymers are joined with piezoelectric polymer transducers. The fabricated sensors can be processed further with hybrid manufacturing technologies and adapted for structure integration. This thesis introduces design methods and models for the preliminary calculation of the novel sensors, which are required for a technology qualification. Therefore, existing modelling approaches adapted and essentially extended for practical use. Design relevant parameters related to the technology like the elastic properties of the applied materials or the geometric dimensions of the manufactured sensor structures are characterized and the system and structure integration of the sensors is presented.
|
Page generated in 0.0439 seconds