• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 67
  • 13
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 163
  • 68
  • 68
  • 41
  • 33
  • 33
  • 31
  • 25
  • 18
  • 18
  • 17
  • 17
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Calculo do parâmetro 'MINDEFF' pelo método multicanal de Schwinger para Positrons.

Euclimar Passos da Silva 01 December 1993 (has links)
Nesta tese, construimos um codigo computacional para calcular o parametro Z(eff) (um parametro de aniquilacao de positrons em ambientes atomicos e/ou moleculares), que pode ser aplicado em geral a atomos e moleculas. Utilizamos o Metodo Multicanal de Schwinger para Positrons (MMSP) para calcular tanto o parametro Z(eff), quanto as secoes de choque elasticas integrais para o espalhamento positron-atomo e positron-molecula. E a primeiravez que a funcao de onda de (N+1) particulas deste metodo e utilizada para o calculo de uma propriedade diferente da usual amplitude de espalhamento. Esta maneira de calcular o Z(eff) e completamente ab initio no sentido dado pela Quimica Quantica. Como resultado destas primeiras aplicacoes obtivemos 4,19 e 13,63 para o Z(eff) do He e H2, respectivamente. Ambas para energias termicas (aproximadamente 0,025eV). Nossos resultados concordam bem com os dados experimentais disponiveis.
42

Signatures of the propagation of primary and secondary cosmic ray electrons and positrons in the galaxy

Porter, Troy Anthony. January 1999 (has links) (PDF)
Includes bibliographical references (8 p.) Examines some of the consequences of the acceleration and production, and propagation, of high energy electrons and positrons in the Galaxy. In particular, predictions are made of the diffuse photon signals arising from the interactions of electrons and positrons with gas, low energy photons, and the galactic magnetic field during their transport in the Galaxy.
43

Defect study of N-type 6H silicon carbide using positron lifetime spectroscopy

Lam, Chi-hung, 林志雄 January 2002 (has links)
published_or_final_version / abstract / toc / Physics / Master / Master of Philosophy
44

Comparing electron and positron scattering factors for applications indiffraction and holography

莫卓威, Mok, Cheuk-wai. January 1997 (has links)
published_or_final_version / Physics / Master / Master of Philosophy
45

Signatures of the propagation of primary and secondary cosmic ray electrons and positrons in the galaxy / Troy Anthony Porter.

Porter, Troy Anthony January 1999 (has links)
Includes bibliographical references (8 p.) / ix, 173, [8] p. : ill. ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Examines some of the consequences of the acceleration and production, and propagation, of high energy electrons and positrons in the Galaxy. In particular, predictions are made of the diffuse photon signals arising from the interactions of electrons and positrons with gas, low energy photons, and the galactic magnetic field during their transport in the Galaxy. / Thesis (Ph.D.)--University of Adelaide, Dept. of Physics and Mathematical Physics, 1999
46

Signatures of the propagation of primary and secondary cosmic ray electrons and positrons in the galaxy / Troy Anthony Porter.

Porter, Troy Anthony January 1999 (has links)
Includes bibliographical references (8 p.) / ix, 173, [8] p. : ill. ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Examines some of the consequences of the acceleration and production, and propagation, of high energy electrons and positrons in the Galaxy. In particular, predictions are made of the diffuse photon signals arising from the interactions of electrons and positrons with gas, low energy photons, and the galactic magnetic field during their transport in the Galaxy. / Thesis (Ph.D.)--University of Adelaide, Dept. of Physics and Mathematical Physics, 1999
47

A study of GaAs and CdZnTe by positron annihilation spectroscopy /

Shan, Yueyue. January 1997 (has links)
Thesis (Ph. D.)--University of Hong Kong, 1998. / Includes bibliographical references (leaves 128-139).
48

Search for excited charged leptons in electron-positron collisions

Vachon, Brigitte Marie Christine 13 November 2018 (has links)
A search for evidence that fundamental particles are made of smaller subconstituents is performed. The existence of excited states of fundamental particles would be an unambiguous indication of their composite nature. Experimental signatures compatible with the production of excited states of charged leptons in electron-positron collisions are studied. The data analysed were collected by the OPAL detector at the LEP collider. No evidence for the existence of excited states of charged leptons was found. Upper limits on the product of the cross-section and the electromagnetic branching fraction are inferred. Using results from the search for singly produced excited leptons, upper limits on the ratio of the excited lepton coupling constant to the compositeness scale are calculated. From pair production searches, 95% confidence level lower limits on the masses of excited electrons, muons and taus are determined to be 103.2 GeV. / Graduate
49

Densidade de probabilidade de aniquilação e outras aplicações do método multicanal de Schwinger ao espalhamento de pósitrons e elétrons

Varella, Marcio Teixeira do Nascimento 16 July 2001 (has links)
Orientador: Marco Aurelio Pinheiro Lima / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-31T23:46:37Z (GMT). No. of bitstreams: 1 Varella_MarcioTeixeiradoNascimento_D.pdf: 2661711 bytes, checksum: c191758528102853de554baceb7fbf71 (MD5) Previous issue date: 2002 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Física / Doutor em Ciências
50

Compteur microfluidique de radioactivité sanguine

Mélançon-Emond, Jean-Nicolas January 2015 (has links)
Les études pharmacocinétiques réalisées grâce à la tomographie d’émission par positrons chez le petit animal requièrent la mesure de la concentration du radiotraceur dans le sang, la fonction d’entrée, pendant la séquence d’imagerie. Un détecteur de positrons placé sur une canule prélevant le sang de l’animal a été démontré comme un moyen avantageux de mesurer la fonction d’entrée chez les rongeurs, mais souffre d’une efficacité de détection limitée. Une nouvelle génération de compteur a été développée afin de surmonter ce problème. Des cartouches microfluidiques, fabriquées par impression 3D dans un matériau biocompatible, remplacent les cathéters traditionnellement utilisés et permettent de diminuer la perte d’énergie des positrons dans les parois. De plus, un circuit de différentiation, implanté via une topologie d’amplificateur d’instrumentation, permet la suppression du bruit induit par le fluide conducteur présent entre une paire de détecteurs opposés. Le système est ainsi beaucoup moins vulnérable que ses prédécesseurs aux interférences électromagnétiques présentes dans l’environnement expérimental. L’efficacité de détection du système utilisant un seul détecteur avec un cathéter PE-50 a été caractérisée comme étant de 17,3 % pour le [indice supérieur 18]F, 25,2 % pour le [indice supérieur 11]C et 1,3 % pour le [indice supérieur 99m]Tc, soit des augmentations de facteurs 4, 2 et 6,5 respectivement, lorsque comparé au système en cathéter antérieur. Une caractérisation subséquente à deux détecteurs a vu les efficacités de détection du [indice supérieur 18]F et du [indice supérieur 11]C augmenter d’un facteur 1,9, soit presque doubler. Une diffusion du liquide hors du microcanal a été observée lors de l’utilisation des cartouches microfluidiques, ce qui modifie le volume de détection au cours de l’acquisition et rend impossible la détermination de l’efficacité de détection avec un microcanal. Bien que ceci démontre que la technologie d’impression 3D choisie est inadaptée à l’utilisation dans une application microfluidique, de récents développements dans le domaine font de la stéréolithographie un remplacement fort prometteur pour la fabrication de microcanaux. L’utilisation de cathéters de polyimide avec parois très minces, comme alternative à la microfluidique, a entraîné des augmentations d’efficacité de détection de 3,2 % et 5,7 % pour les isotopes [indice supérieur 18]F et [indice supérieur 11]C respectivement. L’effet du cathéter de polyimide est encore plus marquant avec le [indice supérieur 99m]Tc, faisant passer l’efficacité de détection de 1,0 % à 1,8 %. Ce fort gain s’explique par la détection d’électrons de conversion de faible énergie, indétectables avec un cathéter traditionnel. De plus, l’utilisation d’un unique cathéter élimine la complexité inhérente au raccord entre un cathéter et une composante microfluidique. L’appareil développé permettra une mesure plus précise de la fonction d’entrée et, utilisé de pair avec des techniques d’imagerie moléculaire, facilitera les études pharmacocinétiques visant le développement de nouveaux traitements et radiotraceurs.

Page generated in 0.0832 seconds