• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 28
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 75
  • 75
  • 75
  • 40
  • 32
  • 31
  • 31
  • 28
  • 20
  • 19
  • 19
  • 19
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Influência da presença e do tipo de retentor intrarradicular no comportamento em fadiga de incisivos centrais restaurados com coroas totais /

Andrade, Guilherme Schmitt de. January 2019 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Coorientador: Lilian Costa Anami / Banca: Carlos Eduardo Francci / Banca: Clovis Pagani / Resumo: Este estudo avalia a influência da presença e tipo de pinos e núcleos na sobrevivência à fadiga de incisivos centrais restaurados com coroas totais. As coroas de 69 incisivos bovinos foram cortadas e as raízes tratadas endodonticamente. As raízes foram distribuídas aleatoriamente em três grupos (n = 23): núcleo de resina composta (NRC), núcleo de resina composta retido por pino de fibra de vidro (PFV) e núcleo metálico fundido (NMF). Todos receberam preparo de coroa total com férula de 2 mm, e então, uma coroa de cerâmica reforçada com leucita foi adesivamente cimentada. Três amostras de cada grupo foram testadas para determinação da carga máxima até a falha. As amostras restantes foram carregadas pelo teste acelerado de fadiga stepwise stress até a fratura ou suspensão após o término de 1,5 x 106 ciclos. A carga e o degrau em que cada espécime falhou foram analisadas pela estatística de Kaplan-Meier e Mantel-Cox (Log Rank test), seguidas por comparação múltipla aos pares, com nível de significância de 5%. O modo de falha foi analisado com estéreomicrocópio. Não houve diferença estatística entre os tratamentos quanto à carga (Mantel-Cox Log-Rank test for trend, X2=0,015, df=1, p=0,901), nem para o número de ciclos (Mantel-Cox Log-Rank test for trend, X2 =3,171, df=1, p=0,995). O modo de falha predominante foi a trinca da coroa. Fratura obliqua da raiz só foi observado nos grupos retidos por pinos. Nos incisivos tratados endodonticamente com férula de 2 mm, a presença e o tipo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This study evaluates the influence of presence and type of post-and-core systems on fatigue survival of non-vital central incisors restored with all-ceramic crowns. The crowns of 69 bovine incisors were cut and endodontically treated. The roots were randomly assigned into three groups (n=23): composite resin build-up (NRC), glass fiber post-retained-composite build-up (PFV) and cast post-and-core (NMF). All specimens received crown preparation with a 2 mm ferrule, and then a leucite-reinforced ceramic crown was adhesively cemented. Three samples from each group were tested for the determination of the maximum load to failure. The remaining samples were loaded by the accelerated fatigue stepwise stress test until fracture or suspension after the end of 1.5 x 106 cycles. The load and the step on which each specimen failed were analyzed by the Kaplan-Meier and Mantel-Cox (Log Rank test) statistics, followed by multiple paired comparisons, with a significance level of 5%. The failure mode was analyzed with stereomicroscope. There was no statistically significant difference between the treatments (Mantel-Cox Log-Rank test for trend, X2=0.015, df=1, p=0.901), nor for the number of cycles (Mantel-Cox Log-Rank test for trend, X2=3.171, df=1, p=0.995). The predominant failure mode was the crown crack. Oblique root fracture was observed only in groups retained by posts. The presence and type of post system did not influence the fatigue survival of the endodontically treated incisors with a 2 mm ferrule. Non-restorable fractures only occurred on teeth restored with posts...(Complete abstract click electronic access below) / Mestre
52

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
53

Estudo in vitro da resistência à fratura de raízes debilitadas. Efeito de diferentes tratamentos restauradores

Ueda, Julio Katuhide [UNESP] 06 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-06Bitstream added on 2014-06-13T19:41:14Z : No. of bitstreams: 1 ueda_jk_dr_arafo.pdf: 3962196 bytes, checksum: a5332fed2f0a6d42be6d3100aaa4ce11 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A preservação e a restauração de dentes despolpados severamente debilitados é um procedimento complexo e relativamente imprevisível. Este estudo avaliou a resistência à fratura de raízes bovinas experimentalmente debilitadas, reconstruídas internamente com diferentes materiais restauradores em combinação com pinos pré-fabricados de fibra de vidro comparados com raízes íntegras restauradas com núcleo metálico fundido ou pino de fibra de vidro. Foram selecionadas raízes de 120 (n=15) incisivos bovinos inferiores de dimensões semelhantes, dos quais, 90 foram internamente preparados para simular uma raiz debilitada. Todas as raízes foram preenchidas com diferentes materiais restauradores e os espécimes foram submetidos ao teste de resistência ao fracasso/ fratura com a aplicação de uma carga compressiva tangencial a um ângulo de 135º em relação ao longo eixo axial das raízes. Resultados indicaram diferenças estatisticamente significante entre os grupos. As raízes debilitadas restauradas com núcleo metálico fundido (grupo NMF-RD) demonstraram os mais baixos valores de resistência à fratura (107.7436 N), sendo estatisticamente diferentes dos demais grupos. As raízes íntegras restauradas com núcleo metálico fundido (NMF-RI) mostraram os maiores valores de resistência (362.3308 N), mas com diferenças estatisticamente significantes somente quando comparadas às raízes debilitadas restauradas com cimento resinoso dual (Variolink II, Ivoclar Vivadent - grupo Vario-RD), cimento resinoso autopolimerizável (Multilink, Ivoclar Vivadent - grupo Multi-RD) e cimento de ionômero de vidro modificado por resina (Vitremer, 3M ESPE - grupo Vitre-RD) associado com pino de fibra de vidro... / The preservation and restoration of severely weakened pulpless teeth is a difficult and relatively unpredictable procedure. This study evaluated the resistance to fracture of experimentally weakened bovine roots internally reconstructed with different filling materials in combination with prefabricated fiberglass posts compared with restored roots that were relatively intact. The roots of 120 mandibular bovine incisors with similar bulks were selected. Of these, 90 were internally prepared to standardized dimensions, thereby simulating weakness. All roots were filled with different restorative materials. The specimens were submitted to the fracture resistance testing with the application of a tangential compressive loading at an angle of 135º in relation to the long axes of the roots. Results indicated statistically significant differences among the groups. The weakened roots restored with the cast post-core (group NMF-RD) demonstrated the lowest fracture resistance values (107.7436 N), which were significantly different from the averages of the remaining groups. The healthy roots restored with the cast post-core (group NMF-RI) showed the highest values (362.3308 N), but statistically significant differences were observed only when compared with weakened roots restored by the dual-cured resin cements (Variolink II, Ivoclar Vivadent - group Vario-RD), chemically cured resin cements (Multilink, Ivoclar Vivadent - group Multi-RD) and resin-modified glass-ionomer cement (Vitremer, 3M ESPE - group Vitre-RD) associated with fiberglass posts. There was not statistically significant differences among the groups of the weakened roots restored with self-adhesive universal resin cement (RelyX Unicem, 3M ESPE - group Unicem-RD), composite resin (Tetric 15 Ceram, Ivoclar Vivadent - group Tetric-RD), group Vitre-RD and group Vario-RD... (Complete abstract click electronic access below)
54

Estudo in vitro da resistência à fratura de raízes debilitadas. Efeito de diferentes tratamentos restauradores /

Ueda, Julio Katuhide. January 2007 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Osmir Batista de Oliveira Junior / Banca: Paulo Afonso Silveira Francisconi / Banca: Luiz Alberto Formighieri / Resumo: A preservação e a restauração de dentes despolpados severamente debilitados é um procedimento complexo e relativamente imprevisível. Este estudo avaliou a resistência à fratura de raízes bovinas experimentalmente debilitadas, reconstruídas internamente com diferentes materiais restauradores em combinação com pinos pré-fabricados de fibra de vidro comparados com raízes íntegras restauradas com núcleo metálico fundido ou pino de fibra de vidro. Foram selecionadas raízes de 120 (n=15) incisivos bovinos inferiores de dimensões semelhantes, dos quais, 90 foram internamente preparados para simular uma raiz debilitada. Todas as raízes foram preenchidas com diferentes materiais restauradores e os espécimes foram submetidos ao teste de resistência ao fracasso/ fratura com a aplicação de uma carga compressiva tangencial a um ângulo de 135º em relação ao longo eixo axial das raízes. Resultados indicaram diferenças estatisticamente significante entre os grupos. As raízes debilitadas restauradas com núcleo metálico fundido (grupo NMF-RD) demonstraram os mais baixos valores de resistência à fratura (107.7436 N), sendo estatisticamente diferentes dos demais grupos. As raízes íntegras restauradas com núcleo metálico fundido (NMF-RI) mostraram os maiores valores de resistência (362.3308 N), mas com diferenças estatisticamente significantes somente quando comparadas às raízes debilitadas restauradas com cimento resinoso dual (Variolink II, Ivoclar Vivadent - grupo Vario-RD), cimento resinoso autopolimerizável (Multilink, Ivoclar Vivadent - grupo Multi-RD) e cimento de ionômero de vidro modificado por resina (Vitremer, 3M ESPE - grupo Vitre-RD) associado com pino de fibra de vidro... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The preservation and restoration of severely weakened pulpless teeth is a difficult and relatively unpredictable procedure. This study evaluated the resistance to fracture of experimentally weakened bovine roots internally reconstructed with different filling materials in combination with prefabricated fiberglass posts compared with restored roots that were relatively intact. The roots of 120 mandibular bovine incisors with similar bulks were selected. Of these, 90 were internally prepared to standardized dimensions, thereby simulating weakness. All roots were filled with different restorative materials. The specimens were submitted to the fracture resistance testing with the application of a tangential compressive loading at an angle of 135º in relation to the long axes of the roots. Results indicated statistically significant differences among the groups. The weakened roots restored with the cast post-core (group NMF-RD) demonstrated the lowest fracture resistance values (107.7436 N), which were significantly different from the averages of the remaining groups. The healthy roots restored with the cast post-core (group NMF-RI) showed the highest values (362.3308 N), but statistically significant differences were observed only when compared with weakened roots restored by the dual-cured resin cements (Variolink II, Ivoclar Vivadent - group Vario-RD), chemically cured resin cements (Multilink, Ivoclar Vivadent - group Multi-RD) and resin-modified glass-ionomer cement (Vitremer, 3M ESPE - group Vitre-RD) associated with fiberglass posts. There was not statistically significant differences among the groups of the weakened roots restored with self-adhesive universal resin cement (RelyX Unicem, 3M ESPE - group Unicem-RD), composite resin (Tetric 15 Ceram, Ivoclar Vivadent - group Tetric-RD), group Vitre-RD and group Vario-RD... (Complete abstract click electronic access below) / Doutor
55

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
56

Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional / Efficiency comparison in stress distribution of different post types: a 3D finite element analysis

Eric Mayer dos Mayer-Santos 03 November 2016 (has links)
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro. / Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.
57

Influência do cimento endodôntico e agente cimentante na retenção de pinos de fibra / Influence of endodontic sealer and luting cements on fiber posts bond strength

Nascimento, Angela Longo do January 2015 (has links)
Objetivos: O objetivo desse estudo foi avaliar a influência da presença do cimento endodôntico e agente cimentante na retenção de pinos de fibra. Metodologia: Cento e oitenta dentes extraídos foram divididos em dois grupos (n=90) de acordo com a forma de obturação: condensação lateral ou obturação apenas do terço apical. Cada um destes grupos foi subdividido em três grupos (n=10) de acordo com o cimento utilizado para a obturação (AH Plus, Endofil e MTAFillapex). Os cimentos foram manipulados e acrescidos de corante Rodamina B na proporção de 0,1% para possibilitar visualização através da microscopia confocal a laser. Quinze dias após a obturação, estes dentes foram preparados para a cimentação do pino de fibra (Reforpost Angelus) com os cimentos RelyX ARC (ARC), U200 e Gold Label Cement Lining (GL). Os dentes foram seccionados transversalmente para obtenção de fatias com 1mm de espessura e submetidos à microscopia confocal a laser para verificar a penetração do cimento endodôntico nos túbulos dentinários, posteriormente ao teste de push-out. O padrão de falha foi analisado em esteromicroscópio e imagens representativas foram feitas em microscopia eletrônica de varredura. Os valores de resistência de união em MPa de acordo com a técnica de obturação foram analisados pelo teste de Mann-Whitney. Os valores de resistência de união dos grupos experimentais foram analisados pelo teste de Kruskal-Wallis e post hoc de Dunn, com nível de significância de 5%. Resultados: Não houve diferença significativa entre as formas de obturação (P>0,05). O tipo de cimento obturador influenciou a resistência de união, e o cimento MTA-Fillapex apresentou valores de resistência de união significativamente inferiores ao AH Plus (P<0,05). Os grupos que utilizaram GL para cimentação dos pinos de fibra de vidro apresentaram valores para o teste de push-out superiores aos cimentos resinosos (P < 0,05). Não houve diferença significativa entre o ARC e o U200 (P > 0,05). Conclusões: Valores de resistência de união mais altos foram observados quando os pinos de fibra foram cimentados com cimento GL . Os padrões de falha mistas foram predominantes e ocorreram em todos os grupos experimentais. / Aim: Evaluate the influence of the endodontic sealer and luting cements on the fiber post bond strength. Methodology: One hundred and eighty extracted teeth were assigned to two groups, considering the root filling technique: lateral condensation or root filling of the apical portion only. Each group were divided into three groups (n=10) according the sealer applied (AH Plus, Endofill or MTA-Fillapex). Rhodamine B was mixed to the sealer in a ratio of 0,1% in order to provide adequate fluorescence assessed by confocal microscopy. Fifty days after root canal filling, post-space preparation were performed with luting cements: RelyX ARC (ARC), U200 and Gold Label Cement Lining (GL). One thick slices were produced and submitted to confocal miscroscopy to assessed sealer penetration into dentinal tubules, and than submitted to push-out test. The failure modes were analysed in stereomicroscope and representative images were obtained in a scanning electron microscope. Push-out strength values of the root filling technique were analyzed using Mann-Whitney test. Push-out strength values of experimental groups were analysed using Kruskal-Wallis and Dunn´s post hoc test at significance level 5%. Results: No significant difference was observed (P>0.05) between the root filling technique. The type of endodontic sealer influenced the push-out bond strength, and MTA-Fillapex sealers presents lower bond strength values than AH Plus (P<0.05). Fiber posts cemented with GL presented higher push-out bond strength than resin cements (P<0.05). There was no significant difference between ARC and U200 (P>0.05). Conclusions: Fiber posts showed higher bond strength values when cemented with GL. Mixed failures were predominant and occurred in all the experimental groups.
58

Análise mecânica de retentores intra-radiculares / Mechanical analysis of endodontic post

Novais, Veridiana Resende 17 August 2018 (has links)
Orientador: Carlos José Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:46:14Z (GMT). No. of bitstreams: 1 Novais_VeridianaResende_D.pdf: 2459662 bytes, checksum: 08447cf6179bf7f73a335f129557029a (MD5) Previous issue date: 2010 / Resumo: Este estudo avaliou os aspectos mecânicos de retentores intra-radiculares pré-fabricados reforçados com fibra, de forma progressiva por meio de etapas distintas e seqüenciais, divididas em três experimentos. No Capítulo 1, foram avaliados parâmetros como: efeito da conicidade do pino, distância entre os suportes, e propriedades dos pinos na flexão e tensão máxima pelo método de elementos finitos na realização de ensaios de flexão de 3 pontos. Foi gerado modelo tri-dimensional de pino de fibra de vidro (RelyX post, 3M-Espe), variando posições dos suportes inferiores e inclinação do pino. Empregou-se propriedades elásticas, características ortotrópicas e isotrópicas. A inclinação dos pinos cônicos para nivelá-los nos suportes teve pouco efeito nas tensões. A flexão aumentou quando 50% da porção carregada do pino envolveu conicidade. Quando o posicionamento do pino envolveu 20% da porção cônica, os valores de flexão foram similares ao modelo de referência, que é o pino cilíndrico, sem inclinação. Propriedades ortotrópicas resultaram em aumento da flexão comparado ao pino isotrópico. No Capítulo 2, propriedades mecânicas de diferentes sistemas de pinos pré-fabricados foram avaliadas por ensaio experimental de flexão de três pontos, assim como análise da correlação entre propriedades mecânicas e características estruturais visualizadas por microscopia eletrônica de varredura associado à software de processamento de imagens. Os resultados demonstraram que as características estruturais afetaram significativamente as propriedades mecânicas dos pinos. Resistência à flexão está diretamente correlacionada com a razão fibra/matriz de resina, enquanto módulo de flexão está inversamente relacionado ao número de fibras/mm2. No Capítulo 3, foi avaliada resistência de união de pino de fibra ao núcleo de preenchimento de resina composta por meio do teste de push-out, variando o tipo de agente silano: três silanos pré-hidrolizados e um sistema de silano de dois componentes; e a temperatura de secagem com ar após aplicação do silano: 23°C e 60°C. Empregou-se ainda grupo controle negativo, no qual nenhum tratamento do pino foi realizado. A aplicação de silano pré-hidrolizado e secagem com ar quente (60°C) dos pinos não influenciou a resistência de união. O agente silano de dois componentes com temperatura de secagem de 23°C apresentou os maiores valores de resistência de união. Desta forma, dentro das limitações dos três experimentos, conclui-se que teste de flexão de três pontos empregado para avaliação de pinos pré-fabricados é válido quando limita a área de ensaio à porção cilíndrica dos pinos; as características estruturais dos pinos têm correlação com as propriedades mecânicas dos mesmos; e a aplicação de ar quente sobre as superfícies de pinos silanizados não tem efeito significativo na resistência de união entre pinos de fibra e preenchimento com resina composta / Abstract: The fiber-reinforcement composite (FRC) posts introduced the new concept of restorative system, in which the various components of the reconstruction: post, cement, filling material and dentin have now become a complex mechanically homogeneous. The knowledge of the structure, composition and physical properties of these fiber posts systems is important in order to minimize the failures and the unsuccessfully clinical. Thus, the present study was conducted to analyze sequentially the biomechanical parameters of FRC posts through different stages divided into three experiments. In Chapter 1, the effect of taper, specimen supports and the properties on flexure and stress response during three-point bending were analyzed using finite element analysis. Three-dimensional non-linear finite element model of a fiber-reinforced composite post was created. Different support positions were evaluated during a simulated three-point bending test. The applied properties were elastic and orthotropic. Tilting the tapered posts to level those in the test setup had little effect on the outcome. Flexure increased when 50% of the bent portion involved taper. If 20% of the bent post involved taper, the flexure values were close to control group. The orthotropic properties also resulted in increased flexure compared to an isotropic post. Maximum stresses were only a little higher when 50% of the bend structure involved taper, while the orthotropic properties had little effect. In Chapter 2, the mechanical properties of different FRC posts were assessed with three-point bending test and evaluated the correlation between mechanical properties and structural characteristics by scanning electron microscopy (SEM) associated with an software of image processing. Then, the structural characteristics significantly affect the mechanical properties of fiber posts. The flexural strength is directly correlated with fiber/matrix ratio, whereas the flexural modulus is inversely correlated with number of fibers per mm2 of post. In the Chapter 3, was evaluate the effect of three prehydrolyzed silanes and one two-bottle coupling agent and two air-drying temperature (23°C and 60°C) on the bond strength between glass fiber posts and composite resin core using micropush-out testing. Additionally, it was tested a control group, which no treatment of fiber post were realized. The results showed that drying with warm air and post silanization with pre-hydrolized silanes had no significant effect on push-out bond strength between glass fiber post and composite resin core. For 23°C air-drying groups, the bond strength with two-bottle coupling agent was higher than the other groups. Then, based on the findings of this study, and within the limitation of this investigation, could be concluded that the regardless of leveling, the flexural stress determination with tapered fiber-reinforced posts in the three-point bending test was valid as long as the tapered portion was limited. Additionally, the mechanical properties have correlation with structural characteristics of FRC posts. Finally, the warm air-drying in silanizated post surface had not significant effect on bond strength between fiber post and composite resin core / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
59

Influencia da altura do remanescente coronario, do tipo de retenção intra-radicular e do tipo de coroa total na resistencia e modo de fratura de raizes bovinas / Influence of coronal tooth structure, type of intraradicular retention and total crown on fracture strength and mode of failure of bovine roots

Resende, Cristina do Amparo 24 September 2007 (has links)
Orientadores: Luis Roberto Marcondes Martins, Carlos Jose Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T14:12:54Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_D.pdf: 3071325 bytes, checksum: 2b04a3fed0292eea5d925854e4ace595 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste estudo foi avaliar a resistência à fratura de raízes bovinas tratadas endodonticamente e restauradas com diferentes retenções intra-radiculares variando-se o tipo de material da coroa total, na presença e ausência do remanescente coronário. Duzentas raízes com dimensões padronizadas foram divididas aleatoriamente em 20 grupos experimentais (n=10) nos seguintes tratamentos: retenções: pino de fibra de vidro (PFV), pino de fibra de vidro reembasado (PFVR), fibra de polietileno (FP), preenchimento do canal com resina composta (RC) e núcleo metálico fundido (NMF); remanescente: ausente ou com 2 mm de altura; coroa total: cerômero ou cerâmica pura. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135º a 0,5 mm/min até ocorrer a falha. Os resultados (ANOVA / Tukey a=0,05) demonstraram que houve diferença estatisticamente significante entre os tipos de pinos (p=0,0058), sendo os grupos restaurados com PFVR e RC apresentaram os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com PFV e PF, e os grupos restaurados com núcleos metálicos fundidos apresentaram os menores valores, não diferindo estatisticamente dos grupos restaurados com PFV e PF. Para os tipos de coroa total (p<0,0001), os grupos restaurados com coroas em cerômero apresentaram maiores valores de resistência à fratura em relação aos grupos restaurados com coroas em cerâmica pura. Os grupos restaurados com fitas de fibra de polietileno mais frequentemente apresentaram padrão de fratura favorável, enquanto os restaurados apenas com resina composta apresentaram padrão de fratura desfavorável, seguidos dos núcleos metálicos fundidos. Para os tipos de coroa total, os grupos restaurados com coroas em cerâmica pura mais frequentemente apresentaram padrão de fratura favorável quando comparados aos grupos restaurados com cerômero, sendo que o mesmo ocorreu para os grupos sem remanescente coronário, quando comparados aos grupos com 2 mm de remanescente / Abstract: The objective of this study was to evaluate the fracture strength of bovine roots endodontically treated and restored by different intraradicular retention varying the type of material of the total crown, in presence or absence of the coronal tooth structure. Two hundred roots with standardized dimensions was divided randomly into 20 experimental groups (n=10) in the following treatments: retentions: fiber glass post, (PFV), relined fiber glass post (PFVR), polyethylene fiber ribbon post (FP), filling of root with composite resin (RC) and cast post and core (NMF); coronal remainder: absence or presence of 2 mm of coronal structure height; total crown: ceromer or all ceramic crown. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135º and 0,5 mm/min until fracture occurred. The results (ANOVA/Tukey a=0,05) showed that it had statistical significant difference among the types of retentions (p=0,0058), being the groups restored with PFVR and RC showed the higher failure loads, not differing statistically from groups restored by PFV and PF, and the groups restored by cast post and core showed lower failure loads, not differing statistically from groups restored by PFV and PF. For the types of total crown (p< 0.0001), the groups restored by ceromer crowns showed higher failure loads than did groups restored by all ceramic crowns. The groups restored by polyethylene fiber ribbon post more frequently showed favorable failure modes, while the restored ones only by composite resin showed unfavorable failure modes, followed by cast post and core. For the types of total crown, the groups restored by all ceramic crowns more frequently showed favorable failure modes than did groups restored with ceromer crowns, being that the same it occurred for the groups without coronal tooth structure, when compared to the groups with 2 mm of coronal structure height / Doutorado / Dentística / Doutor em Clínica Odontológica
60

Efeito da solução de clorexidina a 2% a um cimento ionomérico e um resinoso na adesão de pinos de fibra de vidro em raízes bovinas após 7 dias e 6 meses de armazenamento / Effect of 2% chlorhexidine solution on bonding of a glass ionomer cement and a resin cement to bovine root dentin after 7-day and 6-month storage

Diana Ferreira Gadêlha de Araújo 08 March 2013 (has links)
Este trabalho avaliou a influência do uso de solução de clorexidina a 2% (CHX) na resistência de união de pino de fibra de vidro à dentina radicular, utilizando um agente cimentante ionomérico modificado por resina e um cimento resinoso dual com sistema adesivo convencional, nos terços cervical, médio e apical. Oitenta raízes bovinas foram selecionadas, cortadas em 17mm e tratadas endodonticamente para em seguida serem divididas em 8 grupos: ARC (RelyX ARC/ScothBond MultiPurpose- cimento resinoso); ARC+CHX (ARC associado a CHX); RL (RelyX Luting 2- ionômero de vidro); RL+CHX (RL associado a CHX). Os espécimes de cada protocolo foram divididos em grupos de 7 dias ou 6 meses de armazenamento, depois de serem restaurados com pino de fibra de vidro cônico Exacto. Após 24 horas da cimentação, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias (1mm de espessura). Após o tempo de armazenamento proposto, todas as fatias foram submetidas ao teste de extrusão (push-out) com célula de carga a 0,5mm/min. Os dados foram tabelados considerando as variáveis dos diferentes agentes cimentantes, uso ou não de solução de clorexidina, terços radiculares e tempo de armazenamento. Depois de testados, todos os espécimes foram submetidos à análise dos tipos de fraturas encontradas. Os valores de resistência obtidos foram submetidos à análise estatística através do teste ANOVA a quatro critérios e comparações múltiplas com Tukey, ambos com p<0,05. Os valores obtidos para os grupos armazenados por 7 dias nos terços cervical, médio e apical, respectivamente, foram: ARC- 4,03 (1,85); 4,68 (2,76); 2,97 (1,56); ARC+CHX- 6,75 (3,01); 5,28 (2,89); 3,98 (3,40); RL- 2,26 (0,48); 1,97 (1,31); 1,69 (0,75); RL+CHX- 2,26 (0,96); 2,10 (0,93); 1,65 (1,40). Para os grupos armazenados por 6 meses, os valores resultantes foram: ARC- 6,57 (2,43); 6,56 (2,85); 5,15 (3,07); ARC+CHX- 3,23 (3,13); 1,75 (1,28); 3,26 (2,10); RL- 2,02 (1,13); 1,90 (1,33); 1,40 (1,43); RL+CHX- 1,06 (0,70); 0,78 (0,38); 0,88 (0,90). A análise das fraturas encontrou predominância de falhas adesivas entre cimento e dentina e mistas para os grupos cimentados com ARC. Grupos cimentados com RL apresentaram maioria de falhas do tipo mista e adesiva entre cimento e pino. Os cimentos apresentaram desempenho semelhante para o teste imediato, mas o ARC obteve melhor desempenho após 6 meses de armazenamento. A CHX não exerceu influência positiva para nenhuma das situações testadas. Não foram encontradas diferenças significantes entre os terços de um mesmo grupo. A resistência adesiva foi influenciada principalmente pelo tipo de cimento utilizado. / This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on glassfiber post bonding strength to root dentin with a dual-cured resin cement and a resinmodified glass-ionomer cement, in terms of coronal, middle, and apical thirds. Eighty bovine roots were sectioned 17mm from their apices and endodontically treated and randomly assigned into eight groups: ARC (dual-cured resin cement RelyX ARC + ScothBond Multi Purpose adhesive system); ARC+CHX (ARC associated with CHX); RL (resin-modified glass-ionomer cement RelyX Luting 2) and RL+CHX (RL associated with CHX). Half of each group was subjected to either 7-day or 6-month storage in artificial saliva, after being restored with glass-fiber post Exacto. After 24 hours of luting, the roots were sliced under irrigation to obtain 1mm-thick slices. After the storage time, slices were subjected to push-out test with a universal test machine with a crosshead speed of 0.5mm/min. After this test, the slices were submitted to analysis of failure modes. Data of bond strength were submitted to four-way ANOVA and Tukeys tests (p&#x2264;0.05). The values of average and standard deviation (MPa) regarding coronal, middle, and apical thirds for 7-day groups were: ARC- 4.03 (1.85); 4.68 (2.76); 2.97 (1.56); ARC+CHX- 6.75 (3.01); 5.28 (2.89); 3.98 RL- 2.26 (0.48); 1.97 (1.31); (3.40); 1.69 (0.75); RL+CHX- 2.26 (0.96); 2,10 (0.93); 1.65 (1.40). After 6-month storage, the respectively values obtained were: ARC- 6.57 (2.43); 6.56 (2.85); 5.15 (3.07); ARC+CHX- 3.23 (3.13); 1.75 (1.28); 3.26 (2.10); 1.40 (1.43); RL- 2.02 (1.13); 1.90 (1.33); RL+CHX- 1.06 (0.70); 0.78 (0.38); 0.88 (0.90). The most observed failures were adhesive cement-dentin and mixed failures for ARC groups; for the RL groups, the main failures were adhesive cement-post and mixed modes. Immediate values showed similar performance between both tested cements. After 6 months, ARC yielded higher bond strength compared to RL. For any tested situation, CHX exhibited improved bond strength, disregarding neither luting cement nor time.

Page generated in 0.1195 seconds