• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estabelecimento de material de referência para a determinação da potência da vacina sarampo, caxumba e rubéola (atenuada) pelo fabricante nacional (Bio-Manguinhos) / Establishment of reference material for the determination of the potency of the mumps, measles and rubella (attenuated) vaccine by national manufacturer (Bio- Manguinhos)

Almeida, Danielle da Silva January 2014 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-04-07T11:49:38Z No. of bitstreams: 1 Dissertação_Danielle_Almeida.pdf: 2650975 bytes, checksum: 80a18514ce2bd91e7361e6eacc16a783 (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-04-07T11:49:55Z (GMT) No. of bitstreams: 1 Dissertação_Danielle_Almeida.pdf: 2650975 bytes, checksum: 80a18514ce2bd91e7361e6eacc16a783 (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-04-07T11:50:12Z (GMT) No. of bitstreams: 1 Dissertação_Danielle_Almeida.pdf: 2650975 bytes, checksum: 80a18514ce2bd91e7361e6eacc16a783 (MD5) / Made available in DSpace on 2015-04-07T11:50:12Z (GMT). No. of bitstreams: 1 Dissertação_Danielle_Almeida.pdf: 2650975 bytes, checksum: 80a18514ce2bd91e7361e6eacc16a783 (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / Vacinas são os únicos meios para interromper a cadeia de transmissão de doenças imunopreviníveis. A vacina tríplice viral (contra sarampo, caxumba e rubéola), fornecida por Bio-Manguinhos, é constituída da mistura dos vírus vivos atenuados do sarampo, caxumba e rubéola. É de grande importância o efetivo controle da qualidade deste produto antes do seu ingresso no mercado, sendo necessária a realização do ensaio de potência biológica com a utilização de uma vacina de referência. O presente estudo teve como objetivo principal avaliar um lote vacinal como material de referência de trabalho (MRT) candidato (cMRTBio) para ser utilizado na rotina da determinação de potência da vacina tríplice viral em substituição a vacina disponibilizada pela GlaxoSmithKline (GSK) empregada anteriormente.Este estudo foi baseado nas normativas de compêndios que preconizam os estudos de caracterização do lote candidato quanto à homogeneidade e estabilidade, utilizando-se ferramentas estatísticas adequadas,visando à atribuição do seu valor, atendendo aos propósitos desejados e agregando maior confiabilidade aos ensaios de potência realizados pelo laboratório. O lote designado de 131VVA002Z utilizado como cMRTBio apresentou características como integridade, composição e potência em conformidade com as especificações exigidas. No estudo de homogeneidade, os resultados obtidos foram considerados homogêneos intra-frascos e inter-frascos, já que todos os coeficientes de variação obtidos foram inferiores a 10%, estando dentro do limite de aceitação. A potência estimada de cada componente viral do cMRTBio foi de: 3,73 log10 CCID50 / DH para o vírus do sarampo, 4,75 log10 CCID50 / DH para o vírus da caxumba e 3,67 (log10 CCID50 / DH) para o vírus rubéola, estando dentro das especificações previstas. No estudo de estabilidade verificamos um pequeno decaimento de potência, sendo estes valores considerados irrelevantes, uma vez que a potência encontrada ainda se encontrava dentro dos valores determinados para a especificação da vacina. De acordo com os resultados obtidos, verificamos que o cMRTBio apresentou todas as características exigidas para ser utilizado como MRT, sendo este material protocolado na Instituição como MRT(B)TVV001/13. / Vaccines are the only means to interrupt the transmission chain of transmission of immune predictable diseases. The MMR vaccine (measles, mumps and rubella), supplied by Bio-Manguinhos, is composed of a mixture of live attenuated viruses of measles, mumps and rubella. It is of great importance to the effective control of the quality of this product before its market entrance because it is necessary to perform the test of biological power with the use of a reference vaccine. The main objective of this study was to evaluate a batch vaccine as work reference material (MRT) candidate (cMRTBio) to be used in the routine determination of power of the MMR vaccine in replacing the vaccine made by GlaxoSmithKline (GSK), which was previously employed. This study was based on normative compendia that advocate the studies of characterization of candidate batch homogeneity and stability, using appropriate statistical tools, aiming the allocation of its value, taking into account the purposes intended and aggregating greater reliability to tests of power performed by the laboratory. The batch designated as 131AWV002Z used as cMRTBio presented characteristics such as integrity, composition and power in accordance with the required specifications. In the homogeneity study, the results obtained were considered homogeneous intra-bottles and inter-bottles, considering that all coefficients of variation obtained were lower than 10 %, while within the limit of acceptance. The estimated power of each viral component of cMRTBio was: 3.73 log10 CCID50 / DH for the measles virus, 4.75 log10 CCID50 / DH for the mumps virus and 3.67 (log10 CCID50 / DH) for the rubella virus, being within the specifications provided. In the study of stability we noticed a small decay of power, being these values considered irrelevant, since the power found was still within the values determined for the specification of the vaccine. According to the results obtained, we can notice that the cMRTBio presented all the required characteristics to be used as MRT, being this material filed in the Institution as MRT(B)TVV001/13.
2

Estratégia metodológica para avaliação da potência in vitro das vacinas contra vírus da hepatite B utilizada no Programa Nacional de Imunizações - PNI - Brasil / Methodology for the evaluation of in vitro potency of vaccines against hepatitis B virus used in the National Immunization Program - NIP

Costa, Catia Ines January 2009 (has links)
Made available in DSpace on 2014-08-26T17:15:08Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 56.pdf: 1462155 bytes, checksum: 8fc751b5b82ed7e89810da08aec2279a (MD5) Previous issue date: 2009 / O vírus da hepatite B (HBV) infecta o homem e primatas não humanos. A Organização Mundial da Saúde estima que cerca de dois bilhões de pesos já tiveram contato com o HBV, sendo mais de 350 milhões portadores crônicos, O estudo do HBV teve inicio nos anos 60 com a descoberta do antígeno Austrália, cuja correlação com o antígeno de superfície do vírus da hepatite B (HBsAg) foi estabelecida em 1968. Em 1986 foi licenciada a primeira vacina humana contra a hepatite B, utilizando-se a tecnologia de DNA recombinante, para uso geral da população. A potencia das vacinas contra a hepatite B pode ser avaliada através da ação in vivo (camundongos) ou pela determinação do conteúdo antigênico pelo método de avaliação in vitro. O método in vitro pode ser realizado através do uso de kit ELISA comercial ou desenvolvido in house, padronizado e validado conforme os parâmetros estatísticos descritos para a validação de metodologia para biológicos. Durante o desenvolvimento de um projeto institucional em Bio Manguinhos, na FIOCRUZ, quatorze MAbs anti-HBs foram caracterizados quanto a especificidade para o HBsAg e determinação do perfil isotípico sendo identificado como subclasse IgGl. Oito MAbs foram selecionados e avaliados para o estabelecimento de um ELISA in house para avaliação de potencia das vacinas contra o HBV usadas pelo PNI. Dentre estes o MAb CG2 foi selecionado como anticorpo de captura através dos resultados de reatividade para HBsAg das vacinas dos diferentes produtores (Engerix-B, Hepavax-Gene, Butang, Euvax e Quinvaxem). O ensaio ELISA foi otimizado através de vários parâmetros. A padronização foi realizada considerando as condições básicas do ensaio (placa, tampões, saturação, tempo e agitação da incubação. O MAB CG2 como anticorpo de captura (8ug/ml), as concentrações de vacina (0,2, 0,4, 0,6, 0,8 e 1 ug/ml, e foi preparado e titulado (1:2500) um conjugado Mab anti-HBsAG9 ligado a peroxidase...

Page generated in 0.0417 seconds