• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An Investigation of Naturally Occurring Tastes and Odors from Fresh Waters

Pipes, Wesley O'Feral, Jr. 05 1900 (has links)
The Problem of the cause and control of tastes and odors in water supplies has been the subject of a great many investigations during the last half-century; however, many questions in this field remain to be answered. Theories relating to the cause of tastes and odors occurring in water are still rather numerous and, at present, only a few of them are compatible. Although several procedures have been employed for the eradication of tastes and odors from water supplies, none of them are completely successful.
2

Controle de qualidade de águas potáveis utilizando análise multivariada de imagens / Water quality control of potable water using multivariate image analysis

Damasceno, Deangelis 15 December 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-05-12T18:18:17Z No. of bitstreams: 2 Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-13T11:27:33Z (GMT) No. of bitstreams: 2 Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-05-13T11:27:33Z (GMT). No. of bitstreams: 2 Tese - Deangelis Damasceno - 2016.pdf: 4602737 bytes, checksum: 00c0eed1514b7ff11167a9271ed725e9 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-12-15 / New digital image based-analytical methodologies are proposed to measure pH, alkalinity, total hardness, calcium hardness, magnesium hardness, chloride, fluorine, and total iron of potable water samples. Multivariate image analysis and partial leastsquares regression were applied to BMP digital images acquired from a CCD-scanner. RGB, HIS, XYZ and YCbCr color spaces and 300 dpi images of 200 μL water samples were employed. This micro volume per sample yielded micro volumes of analytical waste per sample (400.0 μL). PLS root mean square error of prediction (RMSEP) for pH analyses was 0.16. RMSEP values for alkalinity, total hardness, calcium hardness, magnesium hardness, chloride, fluorine, and total iron were 0.03, 1.20, 2.01, 0.07, 0.04, and 0.06 mg L-1, respectively. Analytical figures of merit were computed for all PLS proposed methods. Mean relative errors ranging from 0.20% to 1.33 were found. The proposed methods were validated against standard analytical procedures for water quality control. There were no statistical differences between mean PLS value and the one found using the respective standard procedure (ttest, 􀀁 = 0.05). Precision was found statistically equivalent for pH, alkalinity, chloride, fluoride, and total iron when compared to the related reference method (Ftest, 􀀁 = 0.05). Therefore, the new PLS analytical methods proposed for water control quality can be employed as an alternative to standard methods. / Novas metodologias analíticas são propostas nesta Tese para a determinação físicoquímica de pH, Alcalinidade, Dureza Total, Dureza Cálcio, Dureza Magnésio, Cloreto, Fluoreto e Ferro Total de águas potáveis utilizando Análise Multivariada de Imagens (MIA) associada à Regressão Multivariada por Mínimos Quadrados Parciais (PLS). Imagens digitais de amostras obtidas por um scanner de mesa foram empregadas para construir modelos de calibração multivariada. Amostras foram preparadas em laboratório para cada parâmetro investigado. Os modelos PLS foram obtidos de imagens digitais nos espaços RGB, HSI, XYZ e YCbCr, com 300 dpi de resolução e formato de arquivo BMP. As análises foram realizadas em micro-volumes amostrais, sendo necessários 200,0 μL de amostras por análise. O modelo PLS para determinação do pH forneceu RMSEP = 0,16. Já para Alcalinidade, Dureza Total, Dureza Cálcio, Dureza Magnésio, Cloreto, Fluoreto e Ferro Total os valores de RMSEP foram iguais a 0,03, 1,20, 2,01, 0,07, 0,04 e 0,06 mg L-1, respectivamente. Todos os modelos foram avaliados utilizando Figuras de Mérito (FOM) buscando contemplar os parâmetros nacionais de validação de novos métodos analíticos. Para o modelo PLS desenvolvido para determinação de pH, apresentou média dos erros relativos obtidos da diferença entre os valores previstos e os valores de referência, sendo igual a 0,20%. Para Alcalinidade, Dureza Total, Dureza Cálcio e Dureza Magnésio, foram encontrados valores das médias dos erros relativos iguais a 0,85, 9,46 e 9,44%, respectivamente. Já os modelos desenvolvidos para Cloretos, Fluoretos e Ferro, apresentaram valores menores, com médias dos erros relativos iguais a 1,01, 5,15 e 1,33%. Os modelos desenvolvidos foram validados utilizando amostras reais, além de comparados com métodos de referência através de testes de exatidão e de precisão. Todos os métodos desenvolvidos apresentaram exatidão estatisticamente equivalentes aos valores obtidos pelos métodos convencionais (tcal < tcrítico, 􀀁 = 0,05). Todos os modelos desenvolvidos, com exceção dos modelos de Dureza Total, Dureza Cálcio e Dureza Magnésio, apresentaram previsão estatisticamente equivalentes aos métodos convencionais (Fcal > Fcrítico, 􀀁 = 0,05). Dessa forma, as metodologias analíticas desenvolvidas nesta Tese são alternativas aos métodos analíticos convencionais, apresentando vantagens como menor quantidade de amostras (200,0 μL), menor quantidade de reagentes (40,0 μL), menor quantidade de solução indicadora (4,0 μL), menor quantidade de resíduos por amostra (400,0 μL), além da mobilidade dos métodos, não necessitando de laboratórios específicos para análise das amostras.

Page generated in 0.0944 seconds