• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 21
  • 21
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

An Online Monitoring and Fault Location Methodology for Underground Power Cables

January 2016 (has links)
abstract: With the growing importance of underground power systems and the need for greater reliability of the power supply, cable monitoring and accurate fault location detection has become an increasingly important issue. The presence of inherent random fluctuations in power system signals can be used to extract valuable information about the condition of system equipment. One such component is the power cable, which is the primary focus of this research. This thesis investigates a unique methodology that allows online monitoring of an underground power cable. The methodology analyzes conventional power signals in the frequency domain to monitor the condition of a power cable. First, the proposed approach is analyzed theoretically with the help of mathematical computations. Frequency domain analysis techniques are then used to compute the power spectral density (PSD) of the system signals. The importance of inherent noise in the system, a key requirement of this methodology, is also explained. The behavior of resonant frequencies, which are unique to every system, are then analyzed under different system conditions with the help of mathematical expressions. Another important aspect of this methodology is its ability to accurately estimate cable fault location. The process is online and hence does not require the system to be disconnected from the grid. A single line to ground fault case is considered and the trend followed by the resonant frequencies for different fault positions is observed. The approach is initially explained using theoretical calculations followed by simulations in MATLAB/Simulink. The validity of this technique is proved by comparing the results obtained from theory and simulation to actual measurement data. / Dissertation/Thesis / Masters Thesis Electrical Engineering 2016
12

Advancing reliability information for Wave Energy Converters

Thies, Philipp Rudolf January 2012 (has links)
Marine renewable energy promises to provide a significant contribution to the future electricity supply. It is estimated that 17% of today's UK electricity demand could be generated from wave and tidal sources. The ambition to harvest this resource is in the public interest, as it eases the pressures on energy security, holds the potential to reduce carbon emissions and has the prospect to create a new UK industry sector worth £15 billion. From an engineering perspective, marine energy is one of the least developed renewable energy technologies and has to be regarded as unproven. The reliability of components and devices in the harsh marine environment is one of the main engineering challenges. Reliability assessments and the assurance of acceptable reliability levels are dependant on the adequacy of failure information, which is scantily available for marine energy. This thesis shows that large failure rate uncertainties impede the reliability assessment for wave energy converters and how a suite of experimental, numerical and statistical methods can be applied to improve scarcely available reliability information. The analysis of component load conditions identifies fatigue as failure mode of concern and the fatigue life of mooring lines and marine power cables is quantified in a floating wave energy application. A Bayesian statistical approach and dedicated service-simulation component testing is proposed, and implemented to improve the quality of reliability estimates and to provide relevant data and assurance. The methods presented, along with the results, will assist reliability assessment and design during early development stages, and will inform the prediction of maintenance requirements during operation. Reliable marine energy systems will be the technical enabler for the successful transition of prototype devices to a commercially viable marine energy industry.
13

Técnica do Pulso Eletroacústico para medidas de Perfis de Carga Espacial em Dielétricos / Electro-acoustic Pulse to Measure Space Charge Profile in Dielectric Materials

Tomioka, Jorge 31 May 1999 (has links)
Neste trabalho descreve-se a implementação da técnica do pulso eletroacústico (PEA) para a determinação de perfis de carga espacial em dielétricos. O método é baseado no sinal acústico gerado pela aplicação de um pulso de tensão elétrica de curta duração na amostra. O sinal acústico gerado é detectado usando-se um transdutor piezoelétrico acoplado à amostra. São discutidos os detalhes experimentais do sistema e os procedimentos matemáticos para o tratamento do sinal elétrico medido. O tratamento matemático do sinal é baseado na técnica de desconvolução que permite determinar a função de transferência do sistema. A função de transferência permite eliminar do sinal medido as distorções introduzidas pelo circuito de medida, pelas reflexões espúrias do sinal acústico, etc.. Mostra-se também os procedimentos matemáticos para se corrigir a atenuação e dispersão do sinal acústico durante a propagação através da amostra. A técnica PEA foi utilizada para o estudo dos perfis de carga espacial injetada em amostras de polietileno sintetizados com diferentes catalisadores: Ziegler-Natta e Metallocene. O campo elétrico aplicado para polarizar as amostras e injetar cargas elétricas nas amostras foi variado de 0,05 MV/cm a 0,9 MV/cm. Nas amostras de polietileno sem aditivos a injeção de cargas elétricas na amostra é bem menor que em amostras com aditivos anti-oxidantes Mostra-se também que o campo elétrico de ruptura depende da carga injetada na amostra, sendo ele maior quando a polaridade da tensão de teste de ruptura é a mesma da tensão aplicada que provocou a injeção de cargas elétricas na amostra. / It is described the implementation of the electroacustic pulse technique, PEA, for the determination of space charge profiles in dielectrics. The method is based on the acoustic signal generated by the application of a voltage pulse with short duration on the sample. The acoustic signal generated by pulse is detected by using a piezoelectric transducer coupled to the sample. Details of the experimental system and of the mathematical procedure for the treatment of the measured electric signals are discussed. The mathematical treatment is based on the deconvolution technique which enables us to obtain the transference function of the system. The use of a transference function eliminates distortions caused by reflections that are introduced by the measurement circuit. Mathematical procedures for the correction of attenuation and dispersion of the acoustic signal during the propagation throughout the sample are also discussed. The PEA technique was used to measure the profiles of injected space charge in polyethylene synthesized using different catalysts: Ziegler-Natta and Metallocene. The electric field applied to polarize and to inject electric charges in the sample was varied form 0.05MV/cm to 0.9MV/cm. In samples of polyethylene without additives it was observed that the injection of charges is less intense than in samples containing anti oxidant additives. It is also shown that the critical electric field for the breakdown depends on the injected charge on the sample being; larger if the rupture tests were performed using the same polarity of the voltage used to pole the samples. Breakdown measurements were also performed with ozone treated samples.
14

Protection contre les courts-circuits des réseaux à courant continu de forte puissance / Short circuit protection of direct current electrical grid with high power

Descloux, Justine 20 September 2013 (has links)
Dans le domaine du transport de l'électricité, les qualités intrinsèques des réseaux alternatifs s'estompent devant la difficulté imposée par le transport de la puissance réactive lorsque les lignes aériennes ou, plus particulièrement, les câbles souterrains ou sous-marins atteignent des longueurs critiques. Dans le cadre des réflexions visant à exploiter au mieux les énergies renouvelables d'origine éolienne off-shore ou hydrolienne, l'hypothèse de la création d'un réseau électrique à haute tension continue pour acheminer ces énergies jusqu'aux centres de consommation est considérée. Ce travail de thèse est en lien avec le projet européen TWENTIES (Transmission system operation with large penetration of Wind and other renewable Electricity sources in Networks by means of innovative Tools and Integrated Energy Solutions, ref 249812), financé dans le cadre du programme FP7 de la Commission Européenne. Ces travaux traitent de la protection des réseaux à courant continu contre les défauts d'isolement dans les câbles et au niveau des jeux de barre. L'étude se concentre sur des réseaux multi-terminaux bouclés et/ou maillés, et propose d'étudier la faisabilité d'un plan de protection comportant un algorithme principal et un secours en cas de défaillance d'un disjoncteur. / In the area of power transmission grids, the inherent qualities of alternative current networks fade behind the difficulty imposed by the transmission of the reactive power when overhead lines or, particularly, underground or undersea cables reach critical lengths. As part of thought aimed for operate at best renewable energy resources, namely wind or marine resources, the assumption of the creation of a high voltage direct current power grid to dispatch those energies to the consumption centers is considered. This Ph.D work is linked to the European project TWENTIES (Transmission system operation with large penetration of Wind and other renewable Electricity sources in Networks by means of innovative Tools and Integrated Energy Solutions, ref 249812), funded as a part of the 7th framework program of the European Commission. This work deal with the protection of DC grids against insulation faults occurring in the cables or at a busbar. The study focusses on meshed and/or looped multi-terminal grids, and proposes to study the feasibility of a protection plan including a main protection algorithm and a backup in case of breaker failure.
15

Técnica do Pulso Eletroacústico para medidas de Perfis de Carga Espacial em Dielétricos / Electro-acoustic Pulse to Measure Space Charge Profile in Dielectric Materials

Jorge Tomioka 31 May 1999 (has links)
Neste trabalho descreve-se a implementação da técnica do pulso eletroacústico (PEA) para a determinação de perfis de carga espacial em dielétricos. O método é baseado no sinal acústico gerado pela aplicação de um pulso de tensão elétrica de curta duração na amostra. O sinal acústico gerado é detectado usando-se um transdutor piezoelétrico acoplado à amostra. São discutidos os detalhes experimentais do sistema e os procedimentos matemáticos para o tratamento do sinal elétrico medido. O tratamento matemático do sinal é baseado na técnica de desconvolução que permite determinar a função de transferência do sistema. A função de transferência permite eliminar do sinal medido as distorções introduzidas pelo circuito de medida, pelas reflexões espúrias do sinal acústico, etc.. Mostra-se também os procedimentos matemáticos para se corrigir a atenuação e dispersão do sinal acústico durante a propagação através da amostra. A técnica PEA foi utilizada para o estudo dos perfis de carga espacial injetada em amostras de polietileno sintetizados com diferentes catalisadores: Ziegler-Natta e Metallocene. O campo elétrico aplicado para polarizar as amostras e injetar cargas elétricas nas amostras foi variado de 0,05 MV/cm a 0,9 MV/cm. Nas amostras de polietileno sem aditivos a injeção de cargas elétricas na amostra é bem menor que em amostras com aditivos anti-oxidantes Mostra-se também que o campo elétrico de ruptura depende da carga injetada na amostra, sendo ele maior quando a polaridade da tensão de teste de ruptura é a mesma da tensão aplicada que provocou a injeção de cargas elétricas na amostra. / It is described the implementation of the electroacustic pulse technique, PEA, for the determination of space charge profiles in dielectrics. The method is based on the acoustic signal generated by the application of a voltage pulse with short duration on the sample. The acoustic signal generated by pulse is detected by using a piezoelectric transducer coupled to the sample. Details of the experimental system and of the mathematical procedure for the treatment of the measured electric signals are discussed. The mathematical treatment is based on the deconvolution technique which enables us to obtain the transference function of the system. The use of a transference function eliminates distortions caused by reflections that are introduced by the measurement circuit. Mathematical procedures for the correction of attenuation and dispersion of the acoustic signal during the propagation throughout the sample are also discussed. The PEA technique was used to measure the profiles of injected space charge in polyethylene synthesized using different catalysts: Ziegler-Natta and Metallocene. The electric field applied to polarize and to inject electric charges in the sample was varied form 0.05MV/cm to 0.9MV/cm. In samples of polyethylene without additives it was observed that the injection of charges is less intense than in samples containing anti oxidant additives. It is also shown that the critical electric field for the breakdown depends on the injected charge on the sample being; larger if the rupture tests were performed using the same polarity of the voltage used to pole the samples. Breakdown measurements were also performed with ozone treated samples.
16

Kraftkabelförläggning i mark : - en studie av produktionsmetoder

Ivansson, Patrik, Werner, Christian, Bengtsson, Jonas January 2006 (has links)
The assignment given to us by NCC was to compose a degree project based on ground excavations for power cables. The aim of the study was to examine suitable excavation methods depending on different possible terrain conditions. The amount of previously written material within this subject is nearly non- existent and therefore there is a genuine interest by the NCC to receive a compilation of different production methods. The greater part of this study is based upon interviews with several companies active within this area of expertise. The technique of placing the electricity grid beneath ground for safety is today getting more and more common. The aftermath of the hurricane “Gudrun” has forced several power companies to re-evaluate their electric supply network, which has lead to more placements of power cables underground. We have come to the conclusion that there are several factors that would affect the method of choice for cable excavations. Costumer demands, obstacles and the difference in ground conditions are vital factors behind the verdict for suitable production methods.
17

Kraftkabelförläggning i mark : - en studie av produktionsmetoder

Ivansson, Patrik, Werner, Christian, Bengtsson, Jonas January 2006 (has links)
<p>The assignment given to us by NCC was to compose a degree project based on ground excavations for power cables. The aim of the study was to examine suitable excavation methods depending on different possible terrain conditions. The amount of previously written material within this subject is nearly non- existent and therefore there is a genuine interest by the NCC to receive a compilation of different production methods. The greater part of this study is based upon interviews with several companies active within this area of expertise. The technique of placing the electricity grid beneath ground for safety is today getting more and more common. The aftermath of the hurricane “Gudrun” has forced several power companies to re-evaluate their electric supply network, which has lead to more placements of power cables underground.</p><p>We have come to the conclusion that there are several factors that would affect the method of choice for cable excavations. Costumer demands, obstacles and the difference in ground conditions are vital factors behind the verdict for suitable production methods.</p>
18

Řešení elektrizace nové lokality elektrickou energií / Proposal of new locality electrification

Foltýn, Petr January 2011 (has links)
This master’s thesis is concerned with the proposal of new locality electrification. There are 59 detached houses. The thesis is divided into theoretical part and computational part. In the theoretical part, there are all documents necessary for the successful proposal of the electrification. In the computational part is drafted distribution substation, high voltage power cable, proposal of low voltage power cables and protection. Each part is made for two versions (for the degree of electrification A and for the degree of electrification C) and recorded in cadastral maps. The proposal of distribution substation and high voltage power cable is made by traditional method - all calculations are processed by the designer. Low-voltage power cables and protection are implemented in a computer program Sichr (version 11.01) OEZ company.
19

Characterization of Conduction and Polarization Properties of HVDC Cable XLPE Insulation Materials

Ghorbani, Hossein January 2016 (has links)
Since its first introduction in 1998, extruded direct current (DC) cable technology has been growing rapidly leading to many cable system installations with operation voltages up to 320 kV. Cable manufacturers invest heavily on technology development in this field and today extruded DC cable systems for operation voltages as high as 525 kV are commercially available. The electrical field distribution in electrical insulation under DC voltage is mainly determined by the conduction physics, therefore a good understanding of the DC conduction is necessary. In case of Cross-linked Polyethylene (XLPE) insulation, the presence of the peroxide decomposition products (PDP) is believed to influence its electrical properties. The PDP are volatile and therefore they may diffuse out of the samples during sample preparation and testing. Besides, the morphology of the XLPE is known to evolve over time even at moderate temperatures. Since the material may change during preparation, storage and even measurement, the procedure during all stages of the study should be chosen carefully. In this work, the physics of the dielectric response and conduction in XLPE is briefly discussed. The existing measurement techniques relevant to characterization of DC conduction in XLPE insulation materials are reviewed. The procedure for high field DC conductivity measurement is evaluated and recommendations for obtaining reproducible results are listed. Two types of samples are studied, i.e. thick press molded samples and thick plaque samples obtained from the insulation of in-factory extruded cables. For press molded samples, the influence of the press film used during press molding and the effect of heat-treatment on the electrical properties of XLPE and LDPE are studied. High field DC conductivity of XLPE plaque samples is measured with a dynamic electrode temperature to simulate the standard thermal cycles. Investigations show that using PET film during press molding leads to higher apparent DC conductivity and dielectric losses when compared to using aluminum foil. The influence of heat-treatment is different depending on the press film. High field DC conductivity measurements and chemical composition measurement of samples obtained from the cable insulation are in good agreement with the results obtained from the full scale measurements. Finally a non-monotonic dependence of apparent DC conductivity to temperature of some samples pressed with PET film is discovered which to the author’s best of knowledge has not been previously reported in the literature. / Sedan det första införandet i 1998 har extruderad likspänning (DC) kabeltekniken vuxit snabbt och har lett till många existerande kabelsysteminstallationer med driftspänningar upp till 320 kV. Kabeltillverkare investerar kraftigt i teknikutveckling inom detta område och idag finns extruderade DC kabelsystemen tillgängliga för driftspänningar så höga som 525 kV. Elektrisk fältfördelning i isolationsmaterial under hög DC spänning, beror framförallt på materialets elektriska ledningsfysik, därför är en bra förståelse av DC ledningsförmåga nödvändig. Isolationsmaterial av tvärbunden polyeten (PEX) innehåller tvärbindningsrestgaser som tros påverka materialets elektriska egenskaper. Restgaserna är flyktiga och kan diffundera bort från proven under preparering och mätning, även under måttliga temperaturer. PEX materialets morfologi ändras även med tiden. Med tanke på att materialet kan ändras under provpreparering, lagring och även vid mätning, så måste samtliga steg ovan väljas mycket försiktigt. I detta arbete diskuteras grundläggande fysik för dielektrisk polarisering och ledningsförmåga i PEX-isolation tillsammans med granskning av existerande mätteknik relevant för karakterisering av ledningsförmåga i PEX. Procedurer för mätning av DC ledningsförmåga under höga elektriska fält är undersökta och rekommendationer för reproducerbar mätningar är framtagna. Två typer av prover är studerade, tjocka pressade plattor och tjocka plattor som ursvarvats från kommersiell tillverkade högspänningskablar. För pressade plattor, studerades effekten utav press-filmens påverkan på de elektriska egenskaperna hos PEX och LDPE. Påverkan av värmebehandling på DC ledningsförmåga av PEX plattor studerades också. Slutligen studerades DC ledningsförmåga av PEX och LDPE plattor under höga DC fält och med dynamisk temperatur på elektroderna med syftet att efterlikna standardvärmecyklingar. Undersökningarna visade att användningen av PET filmer under pressning av plattor ledde till högre DC ledningsförmåga och högre dielektriska förluster i proven i jämförelse med användning av aluminiumfolie. Påverkan utav värmebehandling är olika beroende på typ av film som används pressningen. Det finns en stark korrelation mellan resultaten från DC konduktivitet och kemisk komposition mätningar från plattor skaffat från kabelisolation och resultaten från fullskaliga kabelmätningar. Slutligen, upptäcktes ett icke monotont beroende av DC konduktivitet hos PEX och LDPE plattor på temperatur som tidigare inte rapporterats i litteraturen. / <p>QC 20160125</p>
20

Analýza a návrh náhrady konkrétního venkovního vedení distribuční sítě / Analysis and design of the replacement of the specific overhead line in distribution network

Račuch, Marek January 2017 (has links)
The diploma thesis deals with the issue of the reconstruction of outdoor cables of low voltage distribution network in exchange for the cable line. It analyzes the important factors which are necessary for the preparation of the project documentation for the issue of the territorial consent. The thesis is divided into 4 main chapters. After the first chapter there is introduced chapter 2, which shows the differences between cable and outdoor cables with their advantages and disadvantages. Chapter 3 deals with the guiding principles for low-voltage cable design and the types of equipment needed for the proper operation of a particular distribution network while respecting the requirements of valid PNEs and ČSNs. Chapter 4 explains the chronology of the process leading to the formulation of a basic technical proposal, which is further addressed in Chapter 5, which deals with the complete formulation of the project documentation for the issue of territorial consent.

Page generated in 0.0406 seconds