201

The production of software that aids in the design of low voltage distribution networks by optimising the locations of junctions

Apostolellis, Justin January 1996 (has links)
A dissertation submitted to the Faculty of Engineering, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering. Johannesburg 1996 / The use of computer-based tools in the design of electrical distribution networks results in the cost effective production and implementation of designs. This is because they help automate time-consuming routine tasks and enable the optimisation of certain aspects of a network design. The production of a tool that performs an optimisation on the low voltage (LV) portion of a distribution network is discussed. It uses the influence that a network's topology has on its associated cost, by applying a search that modifies the topology to result in a minimum cost. The modification of the network's topology is achieved through changing junction positions to alternative locations. It operates on an entire radial LV network, and therefore considers the coupling between junctions in the same network. The user of the tool must specify the alternative locations for each junction in the network, as well as information about the network, such as cable lengths and cable types. The search algorithm is based on an adaptation of the branch and bound method, which is a reduced search algorithm. It has been chosen as opposed to an exhaustive search algorithm to reduce computational requirements. The tool Is most useful for optimising completely underground distribution systems. Test results revealed a 7% saving in the cost of cables for a specific case study. The software has been developed with the application of object-oriented analysis and design within an ISO 9001 accredited software development environment. iii / GR2017
202

Investigation into the steady-state load sharing of weak sources in a low voltage three-phase islanded microgrid

Wu, Meng-Chun Merelda January 2016 (has links)
A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, in ful lment of the requirements for the degree of Master of Science in Engineering. Johannesburg, 2016 / This research investigates the power sharing between distributed energy resources with voltage and frequency droop control. A case study based on voltage sources in an islanded microgrid is set up in the laboratory, referred to as: The Example Microgrid. The Example Microgrid consists of two synchronous generators, active and reactive power loads. A simulation model is constructed based on the laboratory set-up, where componentwise and system-wise testing are completed. The simulation results are validated with the experimental set-up, and it is concluded that the model accurately represents the physical system under steady-state conditions. Further simulation studies on conventional droop controllers are conducted based on the Example Microgrid model. The results indicate that the use of conventional droop control is inappropriate for small, low-voltage islanded microgrids. As a possible application of this work, three variations of adapted droop controllers are simulated and their performance evaluated. It is found that with the adapted droop controllers, the power sharing error can be minimised / M T 2016
203

An investigation into sector designation, prescribed in the Preferential Procurement Policy Framework Act (PPPFA), as a policy instrument for broadening the transformer industry's industrial base

Chibanguza, Tafadzwa C January 2016 (has links)
Thesis (M.Com. (Development Theory and Policy))--University of the Witwatersrand, Faculty of Commerce, Law and Management, School of Economic and Business Sciences, 2016. / The paper identifies that due to the historic evolution of the South African economy, particularly the emphasis placed on energy provision as a catalyst for successful mineral extraction; the seeds were sown for South Africa to be an industrial hub in transformer manufacturing. However, this opportunity has not been realised. Domestic transformer manufacturers have continued to lose market share both domestically and globally. The research identifies a lack of demand, locally, for domestically manufactured transformers as an inherent cause of the challenges faced by the local transformer industry. This lack of demand is also recognized as the reason constraining the potential growth of the industry. The paper identifies a virtuous cycle between capacity utilization and expansion, wherein; higher capacity utilization favourably influences price competitiveness, which increases market share and induces investment into additional capacity. As greater market share is 2 | P a g e attained due to price competitiveness, even higher capacity utilization is achieved; therefore further inducing investment on the expanded capacity and the cycle continues with further expansion. The paper investigates sectoral designation as an industrial policy instrument to achieve this model, that is; increase demand, capacity utilization and ultimately broaden the industrial base of transformer manufacturing. The paper advocates that, while growing in the export market is the ideal end point, the industry would grow its current production capacity threefold if it were provided the opportunity to fully satisfy domestic demand1. As a result, this should be the first market to conquer. It is also identified in the research that sectoral designation as a policy instrument is not without shortfalls, particularly given the unique characteristics inherent in the transformer industry. The paper concludes with policy recommendations to overcome the identified shortfalls and proposes a model for consideration. This dissertation is submitted for the completion of a Master of Commerce in Development Theory and Policy degree. I would like to express utmost gratitude to Dr Paul Jourdan for his supervision, guidance and valuable contribution in the preparation of this research report. / MT2017
204

Análise de distúrbios de tensão em sistemas de distribuição de energia elétrica baseada em sistemas imunológicos artificiais /

Lima, Fernando Parra dos Anjos. January 2013 (has links)
Orientador: Carlos Roberto Minussi / Banca: Mara Lúcia Martins Lopes / Banca: Fabricio Olivetti de França / Resumo: Neste trabalho apresenta-se um método para detecção e classificação de distúrbios de tensão em sistemas de distribuição de energia elétrica. A partir das oscilografias de tensão, medidas na subestação, aplica-se o algoritmo de seleção negativa de um sistema imunológico artificial para diferenciar os sinais entre próprios e não-próprios. Os sinais classificados como próprios representam a operação normal do sistema, isto é, alimentador sem a presença de distúrbio, e os classificados como não-próprios são sinais onde há a presença de uma anormalidade. A análise dos sinais é realizada através do janelamento das oscilografias onde são realizadas comparações entre os sinais e os detectores previamente criados, avaliando a afinidade entre as janelas. Caso a afinidade entre os sinais ultrapasse um limiar preestabelecido pelo operador, é encontrado um casamento, e o sinal é classificado. Com esta proposta busca-se a concepção de um método que possa ser modificado facilmente, para atender a permanente evolução das tecnologias das subestações. Para validar e avaliar o desempenho do método foram realizados testes com quatro sistemas de distribuição de energia elétrica, sendo três sistemas testes de 5, 33 e 84 barras e um sistema real de 134 barras / Abstract: This work presents a method to detect and classify voltage disturbances in electrical distribution systems. The Negative Selection Algorithm of an artificial immunological system is applied to the voltage oscillographs, measured on the substation, to distinguish the signals as self or nonself. The signals classified as self represent the normal operation of the system, i.e. the feeder without disturbance, and those classified as nonself are the signals where there are some abnormalities. The signal analysis is performed by windowing the oscillographs comparing the signals and the detectors previously created, evaluating the affinity with the windows. If the affinity with the signals overpasses a predefined limit a matching is found and the signal is classified. This proposal is a method that can be easily modified to attend the fast evolution of the substation technologies. To validate the performance tests were done to four different distribution systems, including one real system / Mestre
205

Modelo para avaliação de oportunidades de oferta de geração distribuída. / Model for evaluating opportunities for the provision of distributed generation.

Farqui, Thiago Corrêa 08 April 2011 (has links)
A geração de energia elétrica através de grandes empreendimentos, sejam hídricos, térmicos ou nucleares demandam cada vez mais, grandes investimentos e longo período de tempo para início de operação. Em contrapartida, a demanda por este insumo básico para o desenvolvimento e manutenção da sociedade cresce cada vez a um ritmo mais acelerado. Visando atender a essa demanda, existe uma tendência global de instalar uma maior quantidade de pequenas unidades geradoras, ligadas diretamente à rede primária ou á rede secundária de distribuição. Tais unidades são usualmente denominadas de geração distribuída (GD) e dispersa (Gdd), respectivamente. Dentre as diversas vantagens obtidas por estas formas de geração poderá haver aumento da confiabilidade do sistema elétrico, a possibilidade de postergar investimentos necessários à rede de distribuição e a diversificação da matriz energética com maior possibilidade de uso de fontes renováveis de energia. A partir deste conceito foi desenvolvida uma metodologia, fundamentada na teoria de planejamento agregado, para identificar e quantificar potenciais unidades de geração distribuída na área da concessionária de distribuição de energia elétrica, avaliando os respectivos custos e benefícios de cada oportunidade. Por meio destes resultados é possível classificar e, conseqüentemente, priorizar as instalações com maior interesse tanto para o consumidor como, principalmente, para a concessionária local de distribuição de energia. De forma complementar, foram desenvolvidos modelos que possibilitem considerar a geração dispersa no planejamento da expansão dos sistemas de distribuição, bem como avaliar fatores que limitem sua expansão no Brasil. Este trabalho prioriza a análise sob ponto de vista da concessionária de energia elétrica, prática ainda não usual no Brasil, mas com grande potencial de aplicação. / The generation of electrical energy through large power plants (hydro, thermal or nuclear) demands, each time larger investments and high time to be ready for operation. In the other hand, the demand for electrical energy, that is so necessary for the development and maintenance of the society, is growing each day faster. Looking at the attendance of this demand, there is a global tendency to install a larger quantity of small generators, connected directly to the secondary or primary distribution grid of the electrical utility company. These units are known as distributed generation (GD) and dispersed generation (Gdd). Out of the many advantages through the use of distributed generation, the reliability growth in the electrical system, possibility of postpone necessary investments in the distribution network presents high importance and diversify the energetic matrix with the possibility of use renewable resources. From this concept, it was developed a routine, based on the theory of aggregated planning to identify and quantify potential units of distributed generation in the utility company area, evaluating the costs and benefits of each connection for the utility company. Through the results it will be possible the classification of the most interesting units, allowing the decision in conjoint between the consumer and the utility company. As a complement, it was developed mechanisms to make possible to consider disperse generation on the planning of distribution systems expansion. It was also made an evaluation of the factors that restrict the expansion of the disperse generation in Brazil. This thesis focus the analysis considering the utility company impacts, what is not used in Brazil but has a large potential of application.
206

Combate, prevenção e otimização das perdas comerciais de energia elétrica. / Combat, prevention and optimization of non technical losses of electric power distribution.

Penin, Carlos Alexandre de Sousa 28 April 2008 (has links)
As perdas de energia elétrica devidas a furtos e fraudes, também chamadas de Perdas Não-Técnicas (PNT) ou Perdas Comerciais, têm sido matéria prioritária das empresas concessionárias de distribuição de energia elétrica, bem como dos órgãos reguladores, tanto pelo seu crescimento nos últimos anos quanto pelo seu impacto no sistema elétrico brasileiro. As formas de fraude são as mais variadas possíveis, o que gera enormes dificuldades para as concessionárias. Este trabalho tem como objetivo o estudo do problema das PNT utilizando-se de uma abordagem multidisciplinar, que analisa a experiência tanto de concessionárias no Brasil como no exterior. O trabalho discute as melhores práticas para mitigação das mesmas e propõe melhorias nos processos de combate e de prevenção, e nos procedimentos legais para recuperação de receitas, apoiados sobre uma cuidadosa contextualização regulatória. Chamase a atenção para a diversidade sócio-econômica nacional, compara-se com diversos exemplos internacionais, e propõe-se identificar os aspectos mais relevantes a serem considerados na regulação sobre o tema, discutindo procedimentos e metodologias para o equacionamento do montante de recursos a serem aplicados pelas companhias distribuidoras para a adequada redução dessas perdas de energia. Observa-se que grande parte das PNT tem origem em questões de cunho social. O Estado pode e deve estabelecer políticas para resolver tais questões, possibilitando a universalização do acesso e subsidiando o fornecimento de energia elétrica. Não fez parte dessa pesquisa discutir se estes instrumentos são suficientes ou devem ser aprimorados, mas sim analisar amplamente a questão das PNT com base nos condicionantes regulatórios atuais, que obrigam as concessionárias a reduzir estas perdas visando entre outros a modicidade tarifária dos consumidores regulares. / The electric power losses due to thefts and frauds, also called Non technical Losses (NTL), have been priority matter for concessionary companies of electric power distribution, as well as for government regulatory agencies, not only due to rapid growth over the past years but also due to its impact on Brazilian electrical system. There is a wide range of possible types and methods of frauds, causing enormous difficulties to licensed companies. The objective of this work is to study the problem of NTL using a wide approach, analyze the experience of dealerships in Brazil and abroad, discuss the best practices for mitigation of those losses and propose improvements in the combat and prevention processes, and the legal procedures for recovery of incomes, leaning on a careful regulatory context. This study draws attention to Brazil\'s socioeconomic diversity, comparing it to various international examples, and intends to identify the most relevant aspects that must be considered on the theme, discussing procedures and methodologies for the equation of the amount of resources to be applied by distributing companies to achieve the appropriate reduction of NTL. A large part of the commercial losses has its origin in issues of social stamp. The State owes and can establish policies to solve such issues, making possible the access to electric power supply for all consumers. It was not part of this research to discuss if these instruments are enough, but to analyze the issue of the commercial losses thoroughly based in the regulatory policies that push dealerships to reduce NTL objecting reasonable regular consumers\' tariff.
207

Estabelecimento de metas de qualidade na distribuição de energia elétrica por otimização da rede e do nível tarifário. / Establishing quality goals by the optimization of the eletrical distribuition network and rates.

Cyrillo, Ivo Ordonha 12 April 2011 (has links)
A definição de metas de qualidade no fornecimento de energia é feita atualmente através de análises comparativas entre redes semelhantes. Com isso visa-se a otimização dos recursos sem impactos nos investimentos e nas despesas de manutenção. Preceito desta metodologia é que não haja investimentos adicionais e que a qualidade melhore de modo similar à da rede usada como benchmark. Este modelo não consulta diretamente a opinião dos consumidores. Outra particularidade deste modelo é que nem sempre se pode garantir que as redes usadas como benchmark estão em uma situação de ótimo ou próxima dela. De qualquer forma este modelo deve saturar e então devem ser buscadas outras metodologias. Este trabalho apresenta as bases para o estabelecimento de metas de qualidade baseada nos custos de investimentos da concessionária e na opinião e nos custos dos consumidores. O impacto tarifário decorrente da inclusão da qualidade da energia no modelo econômico da concessionária também é analisado. Os resultados apresentados discutem as pesquisas de valoração do custo da qualidade para o consumidor, o estabelecimento de metas de qualidade e a avaliação dos investimentos da concessionária em qualidade da energia elétrica. / The definition of quality goals on the supply of electrical energy is nowadays made in Brazil through the comparison between similar networks. With that, the optimization of the resources is aimed without impacts on the investments and expenditures of maintenance. The precept of this methodology is not having any additional investments so that the quality improves in a similar way to the benchmark network. This model does not consult directly the opinion of consumers. Another particularity of this model is that the situation of the benchmark network cant always be assured to be on its optimal state or close to it. Therefore, this model is expected to saturate, and other methodologies must then be searched. This work presents the basis for the establishment of goals for quality based on the costs of the investments of the utilities and on the consumers costs and opinion. The impact on the rate that may result from the increase of the energy quality on the economical model of the utilities is also analyzed. The results presented discuss the research on valuation of quality cost for the consumer, the establishment of goals for quality and evaluation on the investments on energy quality made by the utilities.
208

Otimização de desempenho de indicadores de continuidade do serviço em concessionárias de distribuição utilizando algoritmos evolutivos. / Optimization of performance indicators for service continuity in distribution utilities using evolutionary algorithms.

Araújo, Renato José Pino de 11 April 2011 (has links)
A partir da reestruturação dos serviços públicos de energia elétrica, foi criada uma série de novas ferramentas regulatórias, simulando e/ou criando um ambiente competitivo, para que as empresas busquem continuamente a evolução de seus indicadores e custos. Com a edição da Resolução nº 024, de 27 de janeiro de 2000, a Agência Nacional de Energia Elétrica (ANEEL) atualizou a regulamentação dos aspectos relativos à continuidade do fornecimento de energia elétrica. As metas de continuidade são definidas através do cluster ao qual cada conjunto de consumidores está vinculado. Os conjuntos são agrupados pelas suas características físicas: área, km de rede primária, número de consumidores, potência de transformadores instalada e consumo médio do conjunto. Um dos pontos focais desta resolução é a possibilidade de uma concessionária agrupar unidades consumidoras, considerando as características técnicas específicas de seu sistema elétrico. Desta forma, o agente regulador permite que as concessionárias modifiquem seus conjuntos de consumidores, desde que fiquem evidenciadas vantagens técnicas, econômicas e sociais da nova proposta em relação ao critério vigente de agrupamento. Visando aperfeiçoar a utilização dos recursos, direcionando as ações para modicidade tarifária e considerando a capacidade de prover condições de atendimento homogêneo, este trabalho busca combinar os consumidores de uma concessionária em conjuntos que minimizem o risco de multa e a necessidade de investimentos nas redes. Este é um problema semelhante ao de redistribuição de eleitores nos distritos de votação nos EUA, conhecido como Political Districting. Para resolver o problema de explosão combinatória resultante das possíveis combinações de áreas e minimizar as multas, o modelo proposto neste trabalho utiliza técnicas de computação evolutiva. A metodologia é ilustrada alterando os 419 conjuntos iniciais de uma concessionária por meio de um algoritmo genético (AG) e um algoritmo imunológico (AI) que otimiza o resultado proposto, minimizando o risco de multas pelo não cumprimento das metas de continuidade. / From the restructuring of the Public Electric Power Sector, new regulatory tools were devised to simulate and create a competitive environment for companies to continuously seek targets for their indicators and costs. With the issue of Resolution nº 024 of January 27, 2000, the National Agency of Electric Energy (ANEEL) updated the rules in dealing with electricity supply continuity. The goals related to the continuity of service are defined through the cluster in which each set of consumers is bound. Consumers are grouped by their physical characteristics: area, length (km) of primary network, the number of consumers, power transformers installed capacity and average consumption. ANEEL allows the utilities to modify their sets of consumers, whenever the technical advantages, economic and social implications of the new proposal in relation to the current criterion of grouping become evident. Considering the possibility of avoiding unnecessary investments in networks, burdening the distribution tariff, this paper attempts to combine the consumers of a utility in sets that minimize the risk of penalties and network investments. This problem is similar to the redistribution in voting districts in the U.S., known as Political Districting. In order to solve the combinatorial explosion problem resulting from the possible combinations of areas and minimization of penalties, the model proposed in this paper uses evolutionary computation techniques. The case study alters the initial 419 sets of consumers of a utility through a genetic algorithm and an artificial immune algorithm, which were proposed to optimize the outcome, minimizing the risk of penalties in not meeting the goals related to continuity of service.
209

Metodologia para avaliação de distorção harmônica de corrente em transformadores de distribuição. / Methodology for evaluation of current harmonic distortion in distribution transformers.

Grandi, André Luis Zago de 23 October 2012 (has links)
Este trabalho apresenta uma metodologia para estimação do conteúdo harmônico de corrente em transformadores de distribuição, utilizando como base de entrada os consumos registrados das diversas unidades consumidoras conectadas aos alimentadores de baixa tensão e campanha de medições de injeções harmônicas em amostra de transformadores de distribuição de uma empresa de distribuição de energia elétrica. A metodologia de análise proposta neste trabalho tem por objetivo, a partir de informações de percentagem de contribuição das diversas classes de consumo supridas por um transformador de distribuição, estimar a curva de carga de corrente harmônica ao longo de 7 dias da semana, incluindo dias úteis e final de semana. A aplicação e validação da metodologia é realizada por meio de medições em novos transformadores de distribuição selecionados aleatoriamente, para depois confrontar os valores estimados com os valores medidos. A metodologia se mostrou adequada para a aplicação a redes de distribuição de energia elétrica, apontando caminhos interessantes para desenvolvimentos futuros. / This MSc dissertation presents a methodology to estimate the harmonic content of currents in distribution transformers, using as input the amounts of consumption recorded over several consumer units connected to low voltage feeders as well as a measurement campaign of harmonic injections in a sample of distribution transformers in a power distribution company. The methodology proposed in this work aims at estimating the daily curve of load harmonic currents over a 7 day period, including weekdays and weekends, which is based on information from the contribution in power consumption from different consumer categories supplied by a distribution transformer. The methodology is applied and validated by comparing the estimated and measured values over a random selection of news distribution transformers. The methodology led to promising results showing that the application in electric power distribution networks should be successful and further developments are worthwhile being investigated.
210

Avaliação quantitativa do efeito dos desequilíbrios da rede e da carga na operação de sistemas de distribuição de energia elétrica

Silva, Júlia Beust da January 2018 (has links)
Este trabalho propõe uma avaliação quantitativa do efeito do desequilíbrio nos índices de operação do sistema de distribuição de energia elétrica. Os cenários apresentados contemplam os desequilíbrios existentes nos circuitos de média tensão e, também, os desequilíbrios na carga. Os desequilíbrios da rede consideram os efeitos da assimetria dos circuitos que provocam acoplamentos diferenciados entre os condutores. Para tanto, foram empregados dois sistemas, sendo um deles teórico e constituído por apenas um circuito e outro uma rede de distribuição padrão do IEEE. A primeira etapa da avaliação é realizada utilizando um modelo que reproduz um trecho fictício de linha de distribuição aérea trifásica com geometria e condutores típicos de redes de distribuição de energia de média tensão a cinco condutores, sendo um deles o condutor fictício de retorno pela terra. Os desequilíbrios de carga foram gerados aleatoriamente através do método de Monte Carlo, considerando variados índices de desequilíbrio. O desequilíbrio das correntes e as perdas do sistema foram determinados com o objetivo de quantificar o impacto das variações realizadas no trecho de linha. Para o sistema teste IEEE 34 Node Test Feeder, foram avaliados os erros decorrentes da consideração do acoplamento médio no cálculo das perdas de potência ativa e reativa, bem como os desequilíbrios de corrente, com o uso do software OpenDSS. Chega-se à conclusão de que o modelo que considera o acoplamento médio é capaz de determinar com muita fidelidade o desequilíbrio das correntes e das perdas para um circuito típico de distribuição em média tensão, não sendo necessária a representação exata das assimetrias dos condutores. / This Master Thesis proposes a quantitative evaluation of the effect of unbalance in the operational indexes of distribution networks. The scenarios comprehend the unbalance of medium voltage circuits and the unbalance in the load. The unbalances consider the effects of the asymmetry of circuits, that cause different couplings between the conductors. Therefore, two systems were implemented, one theoretical and the other a distribution network following the IEEE standard. The first stage of the evaluation is performed using a model that reproduces a fictitious section of a three-phase aerial distribution power line with five conductors considering earth return path, with geometry and typical conductors used in medium voltage energy distribution. The load unbalances were randomly produced using the Monte Carlo method, considering different unbalance rates. The current unbalance factor and the system losses were determined to quantify the impact of the variations in the line section. For the IEEE 34 Node Test Feeder system, the errors from considering the average coupling in the calculation of active and reactive power losses were evaluated, as well as the current unbalance factor. In conclusion, the model that considers the average coupling can successfully determine with a high degree of accuracy the imbalance of currents and the losses for a typical medium-voltage distribution circuit without the need of an exact representation of the asymmetries of the conductors.