Spelling suggestions: "subject:"power oscillation damping"" "subject:"power oscillation camping""
1 |
A probabilistic approach to improving the stability of meshed power networks with embedded HVDC linesPreece, Robin January 2013 (has links)
This thesis investigates the effects of High Voltage Direct Current (HVDC) lines andmulti-terminal grids on power system small-disturbance stability in the presence ofoperational uncertainties. The main outcome of this research is the comprehensiveprobabilistic assessment of the stability improvements that can be achieved through theuse of supplementary damping control applied to HVDC systems.Power systems are increasingly operated closer to stability boundaries in order toimprove their efficiency and economic value whilst a growing number of conventionalcontrolled power plants are being replaced by stochastic renewable generation sources.The resulting uncertainty in conditions can increase the risk of operational stabilityconcerns and should be thoroughly evaluated. There is also a growing necessity toexplore the potential improvements and challenges created by the introduction of newequipment, such as HVDC systems. In recent years, HVDC systems have become moreeconomically competitive and increasingly flexible, resulting in a proliferation ofprojects. Although primarily installed for power transmission purposes, their flexibilityand controllability can provide further benefits, such as the damping of persistentoscillations in the interconnected networks.This work contributes to a number of areas of power systems research, specificallysurrounding the effects of HVDC systems on the small-disturbance stability oftransmission networks. The application and comprehensive assessment of a Wide AreaMeasurement System (WAMS) based damping controller with various HVDC systemsis completed. The studies performed on a variety of HVDC technology types andconfigurations – as well as differing AC test networks – demonstrate the potential forHVDC-based Power Oscillation Damping (POD). These studies include examinationsof previously unexplored topics such as the effects of available modulation capacity andthe use of voltage source converter multi-terminal HVDC grids for POD. Followingthese investigations, a methodology to probabilistically test the robustness of HVDC based damping controllers is developed. This methodology makes use of classificationtechniques to identify possible mitigation options for power system operators whenperformance is sub-optimal. To reduce the high computational burden associated withthis methodology, the Probabilistic Collocation Method (PCM) is developed in order toefficiently identify the statistical distributions of critical system modes in the presenceof uncertainties. Methods of uncertain parameter reduction based on eigenvaluesensitivity are developed and demonstrated to ensure accurate results when the PCM isused with large test systems. Finally, the concepts and techniques introduced within thethesis are combined to probabilistically design a WAMS-based POD controller morerobust to operational uncertainties. The use of the PCM during the probabilistic designresults in rapid and robust synthesis of HVDC-based POD controllers.
|
2 |
A Multichoice Control Strategy for a VSC-HVdcLatorre, Hector January 2008 (has links)
<p>Utilization of power electronics based controllable systems (or devices) in transmission systems has opened new opportunities for the power industry to optimize utilization of the existing transmission systems, and at the same time to keep high system reliability and security.</p><p>As a member of these controllable systems, Voltage Source Converters-based High Voltage direct current (VSC-HVdc) systems have the ability to rapidly control the transmitted active power, and also to independently exchange reactive power with transmissions systems. Therefore, VSC-HVdcs with a suitable control scheme can offer an alternative means to enhance transient stability, to improve power oscillations damping, and to provide voltage support. An interesting application of this system is the analysis of a power system when a VSC-HVdc is connected in parallel with ac transmission lines.</p><p>This thesis presents the derivation of control strategies to damp power oscillations, to enhance the transient stability and to provide voltage support for a VSC-HVdc. The thesis also formulates a multichoice control strategy and its application when the VSC-HVdc is connected in a synchronous system.</p><p>The control strategy for enhancing transient stability is based on the theory of Control Lyapunov Function. The control strategy for increasing the damping is based on Linear Analysis. A very effective well known way to increase damping in the system is modulating the active power through the HVdc. However, besides the control of active power, the thesis explores an alternative way to mitigate power oscillations by controlling the reactive power. This condition might be very useful when the dc link in the VSC-HVdc system is out of service, but the converter stations are in operating conditions.</p><p>A simple model of VSC-HVdc is considered in order to test the control strategy. The model represents the VSC-HVdc as an element in the power system that provides adequate interaction with other systems elements. The model is intended for analysis of power flows and electromechanical transients. It is then sufficient to consider the power frequency components of voltages and currents represented by phasors that vary with time during transients. The model is valid for symmetrical conditions, i.e. positive sequence phasors are used for the representation of the electrical state.</p>
|
3 |
Aplicação de algoritmos bio-inspirados na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS UPFC /Martins, Luís Fabiano Barone. January 2017 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Neste trabalho são apresentados quatro métodos de otimização bio-inspirados, Colônia de Abelhas Artificiais, Otimização por Enxame de Partículas, Algoritmo dos Vagalumes e um híbrido aqui denominado por Bee – PSO, que combina particularidades dos outros três. Estes métodos são utilizados no ajuste coordenado dos parâmetros dos controladores Proporcional-Integral e Suplementares de Amortecimento (Estabilizadores de Sistemas de Potência e o conjunto Unified Power Flow Controller – Power Oscillation Damping). O objetivo é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. São considerados três cenários que englobam duas configurações de instalação dos controladores suplementares e duas condições de carregamento, uma fixa e outra variável. Uma formulação por injeções de corrente do dispositivo Unified Power Flow Controller é sugerida e incorporada ao Modelo de Sensibilidade de Corrente, utilizado para representar o sistema elétrico de potência. Análises estática e dinâmica foram realizadas nos sistemas teste Simétrico de Duas Áreas e New England para validar o modelo de injeções de corrente proposto para o Unified Power Flow Controller e determinar qual dos algoritmos apresentados é o mais eficiente no ajuste coordenado dos parâmetros dos controladores. Dos resultados obtidos foi possível concluir que a versão híbrida proposta neste trabalho possui desempenho s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work four bio-inspired optimization methods, Artificial Bee Colony, Particle Swarm Optimization, Firefly Algorithm, and a hybrid called Bee – PSO, which combines the characteristics of the other three are presented. These methods are used in the coordinated adjustment of the parameters of Proportional-Integral and Supplementary Damping Controllers (Power System Stabilizers and the Unified Power Flow Controller - Power Oscillation Damping). The goal is to insert additional damping into the low-frequency oscillatory modes and thus ensure the stability of the electrical system against minor disturbances. Three scenarios are considered that include two installation configurations of the supplementary controllers and two charging conditions, one fixed and one variable. A current injection formulation of the Unified Power Flow Controller is suggested and incorporated into the Current Sensitivity Model used to represent the electric power system. Static and dynamic analyzes were performed in the Two-Zone Symmetric and New England test systems to validate the proposed current injection model for the Unified Power Flow Controller and to determine which of the presented algorithms is the most efficient in the coordinated adjustment of the parameters of the controllers. From the results obtained it was possible to conclude that the hybrid version proposed in this work has superior performance in most scenarios analyzed, providing solutions with sufficient damping, even when smal... (Complete abstract click electronic access below) / Doutor
|
4 |
Aplicação de algoritmos bio-inspirados na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS UPFC / Application of bio-inspired algorithms in the parametrization of supplementary damping controllers and UPFC FACTS deviceMartins, Luís Fabiano Barone [UNESP] 22 August 2017 (has links)
Submitted by LUIS FABIANO BARONE MARTINS null (luis_barone@ig.com.br) on 2017-08-30T14:29:52Z
No. of bitstreams: 1
tese-luis-fabiano-barone-martins.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-30T17:52:14Z (GMT) No. of bitstreams: 1
martins_lfb_dr_ilha.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5) / Made available in DSpace on 2017-08-30T17:52:14Z (GMT). No. of bitstreams: 1
martins_lfb_dr_ilha.pdf: 3400963 bytes, checksum: 6361e93ee21ab8eb5a35cb9dd7d0bd28 (MD5)
Previous issue date: 2017-08-22 / Neste trabalho são apresentados quatro métodos de otimização bio-inspirados, Colônia de Abelhas Artificiais, Otimização por Enxame de Partículas, Algoritmo dos Vagalumes e um híbrido aqui denominado por Bee – PSO, que combina particularidades dos outros três. Estes métodos são utilizados no ajuste coordenado dos parâmetros dos controladores Proporcional-Integral e Suplementares de Amortecimento (Estabilizadores de Sistemas de Potência e o conjunto Unified Power Flow Controller – Power Oscillation Damping). O objetivo é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. São considerados três cenários que englobam duas configurações de instalação dos controladores suplementares e duas condições de carregamento, uma fixa e outra variável. Uma formulação por injeções de corrente do dispositivo Unified Power Flow Controller é sugerida e incorporada ao Modelo de Sensibilidade de Corrente, utilizado para representar o sistema elétrico de potência. Análises estática e dinâmica foram realizadas nos sistemas teste Simétrico de Duas Áreas e New England para validar o modelo de injeções de corrente proposto para o Unified Power Flow Controller e determinar qual dos algoritmos apresentados é o mais eficiente no ajuste coordenado dos parâmetros dos controladores. Dos resultados obtidos foi possível concluir que a versão híbrida proposta neste trabalho possui desempenho superior na maioria dos cenários analisados, fornecendo soluções com amortecimento suficiente, mesmo quando pequenas variações no carregamento do sistema são consideradas. / In this work four bio-inspired optimization methods, Artificial Bee Colony, Particle Swarm Optimization, Firefly Algorithm, and a hybrid called Bee – PSO, which combines the characteristics of the other three are presented. These methods are used in the coordinated adjustment of the parameters of Proportional-Integral and Supplementary Damping Controllers (Power System Stabilizers and the Unified Power Flow Controller - Power Oscillation Damping). The goal is to insert additional damping into the low-frequency oscillatory modes and thus ensure the stability of the electrical system against minor disturbances. Three scenarios are considered that include two installation configurations of the supplementary controllers and two charging conditions, one fixed and one variable. A current injection formulation of the Unified Power Flow Controller is suggested and incorporated into the Current Sensitivity Model used to represent the electric power system. Static and dynamic analyzes were performed in the Two-Zone Symmetric and New England test systems to validate the proposed current injection model for the Unified Power Flow Controller and to determine which of the presented algorithms is the most efficient in the coordinated adjustment of the parameters of the controllers. From the results obtained it was possible to conclude that the hybrid version proposed in this work has superior performance in most scenarios analyzed, providing solutions with sufficient damping, even when small variations in system loading are considered.
|
5 |
Análise da estabilidade a pequenas perturbações considerando a atuação dos controladores suplementares de amortecimento ESP e TCSC-POD ajustados por um algoritmo BVNS /Gamino, Bruno Rafael. January 2018 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Neste trabalho, uma técnica baseada na Busca em Vizinhança Variável Básica é apresentada para realizar o ajuste coordenado dos parâmetros dos controladores suplementares de amortecimento Thyristor Controlled Series Capacitor - Power Oscillation Damping e Estabilizadores de Sistemas de Potência, a fim de garantir a estabilidade a pequenas perturbações de sistemas elétricos de potência. A estratégia do método de ajuste proposto consiste em explorar sistematicamente estruturas de vizinhança atrelada a uma etapa de busca local, tornando possível a obtenção de soluções ótimas e a manutenção da capacidade de evitar a estagnação em um ótimo local. Um modelo do TCSC por injeção de corrente é apresentado e seus coeficientes de sensibilidade de corrente são deduzidos para incorporação ao Modelo de Sensibilidade de Corrente, que é utilizado para representar o sistema elétrico de potência. Com a inclusão da modelagem dos controladores de amortecimento, simulações são realizadas em dois sistemas testes, conhecidos como sistema Simétrico de Duas Áreas e sistema New England. Os resultados obtidos são analisados para melhor compreensão do comportamento do sistema elétrico de potência quando submetido a uma pequena perturbação e da influência dos controladores de amortecimento neste cenário. Os parâmetros dos controladores são ajustados pelo algoritmo Particle Swarm Optimization, por um Algoritmo Genético e, também, pelo método proposto neste trabalho. Os desempenhos individuais dos métodos d... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work, a technique based on Basic Variable Neighborhood Search is presented to perform the coordinated tuning of the parameters of the supplementary damping controllers Thyristor Controlled Series Capacitor - Power Oscillation Damping and Power System Stabilizers in order to guarantee the small-signal stability of the electric power systems. The strategy of the proposed tuning method consists in systematically exploring neighborhood structures followed by a local search stage, making it possible to obtain optimal solutions and to maintain the ability to avoid stagnation in a local optimum. A current injection model for the TCSC is presented and its current sensitivity coefficients are deduced for incorporation into the Current Sensitivity Model, which is used to represent the electric power system. With the inclusion of the damping controllers modeling, simulations are performed on two test systems, known as the Two-Area Symmetric system and New England system. The results obtained are analyzed to better understand the behavior of the electric power system when subjected to a small disturbance and the influence of the damping controllers in this scenario. The controllers parameters are tuned by the Particle Swarm Optimization algorithm, by a Genetic Algorithm and also by the method proposed in this work. The individual performances of the tuning methods are compared in order to conclude on the technique best suited for this type of problem, including the analysis of a ... (Complete abstract click electronic access below) / Doutor
|
6 |
Estudo da estabilidade a pequenas perturbações de sistemas elétricos de potência multimáquinas sob a ação dos controladores FACTS TCSC e UPFCFurini, Marcos Amorielle [UNESP] 25 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:35Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-01-25Bitstream added on 2014-06-13T20:09:50Z : No. of bitstreams: 1
furini_ma_me_ilha.pdf: 1020610 bytes, checksum: d3a4a2f6ec4cb8559c7d3d6b770ec955 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo desta Dissertação de Mestrado é apresentar a possibilidade de fornecer amortecimento às oscilações de baixa freqüência do sistema elétrico de potência através dos dispositivos FACTS (Flexible Alternating Current Transmission System) TCSC (Thyristor Controlled Series Capacitor) e UPFC (Unified Power Flow Controller). Para isso realiza-se o desenvolvimento e implementação do Modelo de Sensibilidade de Potência para sistemas multmáquinas. Na seqüência são introduzidos os dispositivos TCSC e UPFC, bem como os seus controladores. Apresentam-se resultados de acordo com a evolução dos modelos que representam os dispositivos FACTS, ou seja, parte-se de uma compensação fixa, passando para um modelo dinâmico de primeira ordem e por fim, é incluído o controlador POD (Power Oscillation Damping). A utilização de sinais locais e remotos para entrada do controlador POD também é analisada. Além disso são mostrados os resultados obtidos pela técnica clássica de introdução de amortecimento através de sinais suplementares (os estabilizadores de sistemas de potência – PSS: Power System Stabilizers). O projeto dos controladores POD e PSS é baseado no método da compensação de fase, utilizando a teoria de controle clássico. Fatores de participação, autovetores, autovalores e resíduos de funções de transferência são utilizados como índices para examinar a melhor alocação dos controladores POD e PSS no sistema elétrico de potência. / The objective of this work is to present the possibility to provide damping to low frequencies oscillations of the electrical power systems by FACTS devices (Flexible Alternating Current Transmission System): TCSC (Thyristor Controlled Series Capacitor) and UPFC (Unified Power Flow Controller). This is developed and implemented using the Power Sensitivity Model for multimachine systems. Afterwards, the TCSC and UPFC devices are introduced as well as the controllers. Results are presented according to the evolution of the models that represent the FACTS devices, i.e., it starts with a fixed compensation, passing through a first order dynamic model and finally, it is included a POD controller (Power Oscillation Damping). It is also analyzed the inclusion of local and remote signals for the input of the POD controller. Besides, results obtained by classical techniques of introducing damping by supplementary signals (Power Systems Stabilizer – PSS) are shown. The project of POD and PSS controllers are based on the Phase Compensation Method using the classical control theory. Participation Factor like eigenvalues, eigenvectors and transfer function residues are used as index to examine the best allocation of the POD and PSS controllers on the electrical power systems.
|
7 |
Aplicação do algoritmo genético de Chu-Beasley especializado no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC / Application of the specialized Chu-Beasley's genetic algorithm for adjusting the parameters of supplementary controllers and the IPFC FACTS deviceFortes, Elenilson de Vargas [UNESP] 21 October 2016 (has links)
Submitted by ELENILSON DE VARGAS FORTES null (vargasfortes@yahoo.com.br) on 2016-10-27T22:01:08Z
No. of bitstreams: 1
Tese.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-11-03T18:32:27Z (GMT) No. of bitstreams: 1
fortes_ev_dr_ilha.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5) / Made available in DSpace on 2016-11-03T18:32:27Z (GMT). No. of bitstreams: 1
fortes_ev_dr_ilha.pdf: 4090366 bytes, checksum: c721654fbc082e717b79dc074adcbfa0 (MD5)
Previous issue date: 2016-10-21 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho apresenta o Algoritmo Genético de Chu-Beasley Especializado para realizar o ajuste coordenado dos parâmetros de controladores Proporcional-Integral e suplementares de amortecimento (Estabilizadores de Sistemas de Potência e Interline Power Flow Controller - Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal deste trabalho é inserir amortecimento adicional às oscilações eletromecânicas de baixa frequência classificadas como local e interárea. Para representar o sistema, é utilizado o Modelo de Sensibilidade de Corrente. Desse modo, todos os seus dispositivos e componentes foram modelados por injeção de corrente e, portanto, um novo modelo de injeção de corrente para o Interline Power Flow Controller é apresentado. Três sistemas teste foram utilizados nas simulações realizadas neste trabalho, sendo: Simétrico de Duas Áreas, New England e o Sul Brasileiro Reduzido. O desempenho da metodologia proposta (Algoritmo Genético de Chu-Beasley Especializado), no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros dois algoritmos bastantes difundidos na literatura: Particle Swarm Optimization e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o algoritmo Genético de Chu-Beasley Especializado foi mais eficiente que as demais técnicas apresentadas, obtendo soluções robustas quando variações de cargas foram consideradas, sendo, portanto, credenciado como ferramenta no estudo da análise da estabilidade a pequenas perturbações. / CNPq: 141084/2016-2
|
8 |
Estudo da estabilidade a pequenas perturbações de sistemas elétricos de potência multimáquinas sob a ação dos controladores FACTS TCSC e UPFC /Furini, Marcos Amorielle. January 2008 (has links)
Orientador: Percival Bueno de Araujo / Banca: Antonio Padilha Feltrin / Banca: Wellington Santos Mota / Resumo: O objetivo desta Dissertação de Mestrado é apresentar a possibilidade de fornecer amortecimento às oscilações de baixa freqüência do sistema elétrico de potência através dos dispositivos FACTS (Flexible Alternating Current Transmission System) TCSC (Thyristor Controlled Series Capacitor) e UPFC (Unified Power Flow Controller). Para isso realiza-se o desenvolvimento e implementação do Modelo de Sensibilidade de Potência para sistemas multmáquinas. Na seqüência são introduzidos os dispositivos TCSC e UPFC, bem como os seus controladores. Apresentam-se resultados de acordo com a evolução dos modelos que representam os dispositivos FACTS, ou seja, parte-se de uma compensação fixa, passando para um modelo dinâmico de primeira ordem e por fim, é incluído o controlador POD (Power Oscillation Damping). A utilização de sinais locais e remotos para entrada do controlador POD também é analisada. Além disso são mostrados os resultados obtidos pela técnica clássica de introdução de amortecimento através de sinais suplementares (os estabilizadores de sistemas de potência - PSS: Power System Stabilizers). O projeto dos controladores POD e PSS é baseado no método da compensação de fase, utilizando a teoria de controle clássico. Fatores de participação, autovetores, autovalores e resíduos de funções de transferência são utilizados como índices para examinar a melhor alocação dos controladores POD e PSS no sistema elétrico de potência. / Abstract: The objective of this work is to present the possibility to provide damping to low frequencies oscillations of the electrical power systems by FACTS devices (Flexible Alternating Current Transmission System): TCSC (Thyristor Controlled Series Capacitor) and UPFC (Unified Power Flow Controller). This is developed and implemented using the Power Sensitivity Model for multimachine systems. Afterwards, the TCSC and UPFC devices are introduced as well as the controllers. Results are presented according to the evolution of the models that represent the FACTS devices, i.e., it starts with a fixed compensation, passing through a first order dynamic model and finally, it is included a POD controller (Power Oscillation Damping). It is also analyzed the inclusion of local and remote signals for the input of the POD controller. Besides, results obtained by classical techniques of introducing damping by supplementary signals (Power Systems Stabilizer - PSS) are shown. The project of POD and PSS controllers are based on the Phase Compensation Method using the classical control theory. Participation Factor like eigenvalues, eigenvectors and transfer function residues are used as index to examine the best allocation of the POD and PSS controllers on the electrical power systems. / Mestre
|
9 |
Aplicação do algoritmo genético de Chu-Beasley especializado no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /Fortes, Elenilson de Vargas January 2016 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Este trabalho apresenta o Algoritmo Genético de Chu-Beasley Especializado para realizar o ajuste coordenado dos parâmetros de controladores Proporcional-Integral e suplementares de amortecimento (Estabilizadores de Sistemas de Potência e Interline Power Flow Controller - Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal deste trabalho é inserir amortecimento adicional às oscilações eletromecânicas de baixa frequência classificadas como local e interárea. Para representar o sistema, é utilizado o Modelo de Sensibilidade de Corrente. Desse modo, todos os seus dispositivos e componentes foram modelados por injeção de corrente e, portanto, um novo modelo de injeção de corrente para o Interline Power Flow Controller é apresentado. Três sistemas teste foram utilizados nas simulações realizadas neste trabalho, sendo: Simétrico de Duas Áreas, New England e o Sul Brasileiro Reduzido. O desempenho da metodologia proposta (Algoritmo Genético de Chu-Beasley Especializado), no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros dois algoritmos bastantes difundidos na literatura: Particle Swarm Optimization e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o algoritmo Genético de Chu-Beasley Especializado foi mais eficiente que as demais técnicas apresentadas, obtendo soluções robustas quando variações de cargas foram consideradas, sendo, portanto, credenciado como ferramenta no estudo da análise d... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
|
10 |
Performance Quantification of Interarea Oscillation Damping Using HVDCBjörk, Joakim January 2019 (has links)
With the transition towards renewable energy, and the deregulation of the electricity market, generation patterns and grid topology are changing. These changes increase the need for transfer capacity. One limiting factor, which sometimes leads to underutilization of the transmission grid, is interarea oscillations. These system-wide modes involve groups of generators oscillating relative to each other and are sometimes hard to control due to their scale and complexity. In this thesis we investigate how high-voltage direct current (HVDC) transmission can be used to attenuate interarea oscillations. The thesis has two main contributions. In the first contribution we show how the stability of two asynchronous grids can be improved by modulating the active power of a single interconnecting HVDC link. One concern with modulating HVDC active power is that the interaction between interarea modes of the two grids may have a negative impact on system stability. By studying the controllability Gramian, we show that it is always possible to improve the damping in both grids as long as the frequencies of their interarea modes are not too close. For simplified models, it is explicitly shown how the controllability, and therefore the achievable damping improvements, deteriorates as the frequency difference becomes small. The second contribution of the thesis is to show how coordinated control of two (or more) links can be used to avoid interaction between troublesome interarea modes. We investigate the performance of some multivariable control designs. In particular we look at input usage as well as robustness to measurement, communication, and actuator failures. Suitable controllers are thereby characterized. / Övergången till förnybar energi och avregleringen av elmarknaden leder till förändrade produktions-och överföringsmönster. Dessa förändringar medför behov av en ökad överföringskapacitet. En begränsande faktor, som kan leda till ett underutnyttjande av stamnätet, är interareapendlingar. Dessa systemövergripande pendlingar involverar grupper av generatorer som svänger i förhållande till varandra. Interareapendlingar är ibland svåra att styra på grund av deras skala och komplexitet. I denna avhandling undersöker vi hur förbindelser med högspänd likström, engleska high-voltage direct current (HVDC), kan användas för att dämpa interareapendlingar. Avhandlingen har två huvudbidrag. I det första bidraget visar vi hur stabiliteten hos två olika synkrona nät kan förbättras genom att modulera den aktiva effekten hos en enda HVDC-länk. Ett bekymmer med aktiv effektmodulering är att växelverkan mellan interareapendlingar hos de två näten kan ha en negativ inverkan på systemets stabilitet. Genom att studera styrbarhetsgramianen visar vi att det alltid är möjligt att förbättra dämpningen i båda näten så länge som frekvenserna hos deras interareapendlingar inte ligger för nära varandra. För förenklade modeller visas det uttryckligen hur styrbarheten och därmed de möjliga dämpningsförbättringarna, försämras då frekvensskillnaden blir liten. Avhandlings andra bidrag visar hur koordinerad styrning av två (eller fler) länkar kan användas för att undvika växelverkan mellan besvärliga interareapendlingar. Vi undersöker prestandan hos olika typer av flervariabla regulatorer. I synnerhet undersökers styrsignalsanvändning samt robusthet mot mät-, kommunikations- och aktuatorfel. Därigenom karakteriseras lämpliga regulatortyper. / <p>QC 20190308</p>
|
Page generated in 0.1305 seconds