• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 444
  • 5
  • 5
  • 5
  • 5
  • 5
  • 1
  • 1
  • Tagged with
  • 450
  • 200
  • 131
  • 74
  • 71
  • 69
  • 67
  • 65
  • 64
  • 63
  • 60
  • 59
  • 56
  • 53
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Analises histopatologica e imunohistoquimica e amplificação de DNA atraves de Real-Time PCR em carcinoma espinocelular de cavidade oral e em osteossarcoma dos maxilares

Lopes, Márcio Ajudarte, 1967- 03 August 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T13:14:28Z (GMT). No. of bitstreams: 1 Lopes_MarcioAjudarte_LD.pdf: 1399819 bytes, checksum: 17c0aaf29832de33633382b30d6871dd (MD5) Previous issue date: 2001 / Resumo: Não informado / Abstract: Not informed / Tese (livre-docencia) - Univer / Semiologia / Livre Docente em Estomatopatologia
42

Avaliação da centralização do preparo biomecânico em canais radiculares preparados com os sistemas ProTaper UniversalTM, ProfileTM e Twisted FileTM

de Andrade Mendes, Daniela 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:02:04Z (GMT). No. of bitstreams: 2 arquivo962_1.pdf: 2744566 bytes, checksum: 63c273abdb2f642bd8167f8e9e67f0b2 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / O conhecimento da morfologia interna do sistema de canais radiculares e suas diversas conformações têm um importante papel no sucesso da terapia endodôntica. A familiarização com as curvaturas torna-se importante para execução de um correto planejamento do preparo biomecânico dos canais radiculares escolhendo técnicas e instrumentos apropriados para cada situação, uma vez que a manutenção da sua anatomia original é de suma importância para o sucesso da terapêutica aplicada. O preparo biomecânico do sistema de canais radiculares apresenta como objetivo promover a limpeza, modelagem tridimensional e a completa desinfecção do sistema de canais radiculares utilizando instrumentos e soluções que permitam maior precisão e menor tempo de trabalho. Desde sua introdução, os instrumentos endodônticos confeccionados em níquel-titânio (NiTi) vêm sendo largamente utilizados por apresentar grande flexibilidade e capacidade em manter a morfologia original do canal radicular. Instrumentos rotatórios confeccionados com esta liga promovem o alargamento das porções curvas dos canais mantendo a sua anatomia original, provocando menores índices de desvios. Esta pesquisa avaliou a centralização do preparo biomecânico após a instrumentação mecânico-rotatória efetuada por três sistemas rotatórios (ProTaperTM, ProFileTM e Twisted-FileTM) em canais radiculares curvos e a conformação das paredes dentinárias após o preparo biomecânico efetuado pelo sistema ProTaperTM. Diante dos resultados obtidos, pôde-se concluir que: os três sistemas analisados ProTaper, ProFile e Twisted-File foram capazes de realizar o preparo biomecânico centralizado na porção apical do canal radicular provocando pequenas proporções de desvio, não sendo observadas diferenças estatisticamente significantes entre os mesmos; O sistema rotatório ProTaper UniversalTM não foi totalmente eficaz em instrumentar todas as paredes do terço apical dos canais radiculares, apresentando porém uma capacidade aceitável para a modelagem de canais radiculares curvos
43

Influência do pré-alargamento cervical no desgaste promovido pelos instrumentos rotatórios de níquel-titânio na região apical: Estudo em canais simulados curvos / Influence of cervical preflaring on prepared canal shape in simulated curved root canals prepared with nickel-titanium rotary systems

Barroso, Juliana Machado 08 January 2008 (has links)
A proposta desse estudo in vitro foi avaliar a influência do pré-alargamento cervical no desgaste apical de canais simulados curvos preparados com instrumentos rotatórios de níquel-titânio. Foram confeccionados 30 blocos de resina com canais simulados de 20 graus de curvatura que foram divididos aleatoriamente em três grupos distintos (n=10) de acordo com o tipo de alargamento cervical realizado: Grupo I - sem alargamento cervical; Grupo II - alargamento cervical realizado com brocas CP Drill®; Grupo III - alargamento cervical realizado com brocas LA Axxess®. Previamente ao alargamento cervical os canais foram preenchidos com tinta nanquim em toda sua extensão e realizaram-se as fotografias iniciais com auxílio de máquina digital posicionada em estativa. Para o preparo apical utilizaram-se instrumentos rotatórios K3® na seqüência de 20.02 até 45.02, sendo que, entre o intervalo do uso de cada instrumento o canal foi preenchido, novamente, com tinta nanquim e realizada a fotografia final para cada instrumento. As fotografias pré e pós-operatórias foram sobrepostas e procedeu-se a mensuração do desgaste linear da parede interna e externa do canal simulado no ápice da curvatura e no ápice do canal proporcionado por cada instrumento, com auxílio do software Image Tool. A diferença entre esses valores, de acordo com cada área do canal avaliada, foi submetida à análise estatística. O teste de Regressão Linear permitiu estabelecer uma correlação entre o calibre do instrumento e o desgaste do canal, que pode ser traduzida em uma equação matemática, indicando que é diretamente proporcional. O teste de Kruskal-Wallis (complementado com pós-teste de Dunn) permitiu a comparação do desgaste entre os diferentes grupos experimentais. Por meio desses testes pode-se observar que grupo onde não foi realizado o pré-alargamento cervical apresentou padrões de desgastes diferentes daqueles onde o preparo foi executado. O grupo sem pré-alargamento provocou o desgaste acentuado do lado externo da curvatura, enquanto os grupos preparados com CP Drill® e LA Axxess® mostraram padrões de desgaste semelhantes, denotando a maior centralização do instrumento no canal em ambas as regiões analisadas (ápice da curva e ápice do canal). Pode-se concluir que o pré-alargamento cervical influenciou de forma positiva no preparo da região apical de canais simulados curvos, proporcionando preparos mais centralizados dessa região. / The purpose of this in vitro study was to evaluate the influence of cervical preflaring on prepared canal shape in simulated curved root canals prepared with nickel-titanium rotary systems. Thirty resin blocks with simulated canals with 20º curvature were fabricated and randomly assigned to three groups (n=10) according to the type of cervical preflaring: Group I - no cervical preflaring; Group II - cervical preflaring with CP Drill® burs; Group III - cervical preflaring with LA Axxess® burs. Previously cervical preflaring, the canals were thoroughly filled with India ink and the initial photographs were taken using a digital camera fixed in a static position. Right after, apical preparation was performed using 20.02 to 45.02 K3® rotary instruments. At each change of file, the canals were refilled with India ink and the final photographs were taken for each instrument. The initial and final photographs were superimposed and linear dentin removal produced by each type of rotary instrument was measured with specific software at the internal and external portions of the curvature apex and at the canal apex. The difference between the initial and final values was analyzed statistically, according to each canal region. Statistical analysis by linear regression established a correlation between instrument size and canal transportation, which can be expressed by a mathematical equation. This correlation is directly proportional, which means that the greater instrument, the more accentuated the canal transportation. Additionally, Kruskal- Wallis test (complemented by the Dunn\' post-test) allowed comparing dentin removal among the different experimental groups. These tests revealed that the non-flared group presented different dentin removal patterns, as compared to the groups where cervical preflaring was undertaken. The group without preflaring presented a significantly greater dentin removal on the external side of curvature, while the groups preflared with CP Drill® and LA Axxess® exhibited similar dentin removal patterns, demonstrating a greater centralization of the instrument inside the canal, for both analyzed regions (curvature apex and canal apex). It may be concluded that cervical preflaring influenced positively the apical preparation of simulated curved canals, producing more centralized preparations in this region.
44

Influência do pré-alargamento cervical no desgaste promovido pelos instrumentos rotatórios de níquel-titânio na região apical: Estudo em canais simulados curvos / Influence of cervical preflaring on prepared canal shape in simulated curved root canals prepared with nickel-titanium rotary systems

Juliana Machado Barroso 08 January 2008 (has links)
A proposta desse estudo in vitro foi avaliar a influência do pré-alargamento cervical no desgaste apical de canais simulados curvos preparados com instrumentos rotatórios de níquel-titânio. Foram confeccionados 30 blocos de resina com canais simulados de 20 graus de curvatura que foram divididos aleatoriamente em três grupos distintos (n=10) de acordo com o tipo de alargamento cervical realizado: Grupo I - sem alargamento cervical; Grupo II - alargamento cervical realizado com brocas CP Drill®; Grupo III - alargamento cervical realizado com brocas LA Axxess®. Previamente ao alargamento cervical os canais foram preenchidos com tinta nanquim em toda sua extensão e realizaram-se as fotografias iniciais com auxílio de máquina digital posicionada em estativa. Para o preparo apical utilizaram-se instrumentos rotatórios K3® na seqüência de 20.02 até 45.02, sendo que, entre o intervalo do uso de cada instrumento o canal foi preenchido, novamente, com tinta nanquim e realizada a fotografia final para cada instrumento. As fotografias pré e pós-operatórias foram sobrepostas e procedeu-se a mensuração do desgaste linear da parede interna e externa do canal simulado no ápice da curvatura e no ápice do canal proporcionado por cada instrumento, com auxílio do software Image Tool. A diferença entre esses valores, de acordo com cada área do canal avaliada, foi submetida à análise estatística. O teste de Regressão Linear permitiu estabelecer uma correlação entre o calibre do instrumento e o desgaste do canal, que pode ser traduzida em uma equação matemática, indicando que é diretamente proporcional. O teste de Kruskal-Wallis (complementado com pós-teste de Dunn) permitiu a comparação do desgaste entre os diferentes grupos experimentais. Por meio desses testes pode-se observar que grupo onde não foi realizado o pré-alargamento cervical apresentou padrões de desgastes diferentes daqueles onde o preparo foi executado. O grupo sem pré-alargamento provocou o desgaste acentuado do lado externo da curvatura, enquanto os grupos preparados com CP Drill® e LA Axxess® mostraram padrões de desgaste semelhantes, denotando a maior centralização do instrumento no canal em ambas as regiões analisadas (ápice da curva e ápice do canal). Pode-se concluir que o pré-alargamento cervical influenciou de forma positiva no preparo da região apical de canais simulados curvos, proporcionando preparos mais centralizados dessa região. / The purpose of this in vitro study was to evaluate the influence of cervical preflaring on prepared canal shape in simulated curved root canals prepared with nickel-titanium rotary systems. Thirty resin blocks with simulated canals with 20º curvature were fabricated and randomly assigned to three groups (n=10) according to the type of cervical preflaring: Group I - no cervical preflaring; Group II - cervical preflaring with CP Drill® burs; Group III - cervical preflaring with LA Axxess® burs. Previously cervical preflaring, the canals were thoroughly filled with India ink and the initial photographs were taken using a digital camera fixed in a static position. Right after, apical preparation was performed using 20.02 to 45.02 K3® rotary instruments. At each change of file, the canals were refilled with India ink and the final photographs were taken for each instrument. The initial and final photographs were superimposed and linear dentin removal produced by each type of rotary instrument was measured with specific software at the internal and external portions of the curvature apex and at the canal apex. The difference between the initial and final values was analyzed statistically, according to each canal region. Statistical analysis by linear regression established a correlation between instrument size and canal transportation, which can be expressed by a mathematical equation. This correlation is directly proportional, which means that the greater instrument, the more accentuated the canal transportation. Additionally, Kruskal- Wallis test (complemented by the Dunn\' post-test) allowed comparing dentin removal among the different experimental groups. These tests revealed that the non-flared group presented different dentin removal patterns, as compared to the groups where cervical preflaring was undertaken. The group without preflaring presented a significantly greater dentin removal on the external side of curvature, while the groups preflared with CP Drill® and LA Axxess® exhibited similar dentin removal patterns, demonstrating a greater centralization of the instrument inside the canal, for both analyzed regions (curvature apex and canal apex). It may be concluded that cervical preflaring influenced positively the apical preparation of simulated curved canals, producing more centralized preparations in this region.
45

Contribuição da cultura de entressafra para a estruturação do solo em área sob sistema de semeadura direta /

Fernandes, Mariele Monique Honorato. January 2018 (has links)
Orientador: Carolina Fernandes / Banca: José Eduardo Corá / Banca: Maria Helena Moraes Spinelli / Resumo: Sistemas de cultivo conservacionista, como o sistema de semeadura direta, seguem como princípios, a ausência de preparo do solo, a formação e a manutenção de cobertura vegetal e a rotação de culturas. Contudo, quando uma das premissas não é adequadamente adotada pode haver alterações na estrutura do solo e, consequentemente, nas relações solo-planta. Assim, objetivou-se avaliar os atributos físicos e o carbono orgânico do solo em área com preparo do solo e pousio (vegetação espontânea) na entressafra e em áreas sem preparo do solo, com pousio (vegetação espontânea) e com cultivo na entressafra. As áreas com sistemas de cultivo distintos localizaram-se próximas às coordenadas geodésicas 21°14'05'S, 48°17'05'W e altitude média de 550 metros, com clima tipo Aw. O solo das três áreas caracterizou-se como Latossolo Vermelho de textura argilosa (539 g kg-1 de argila na camada de 0,00-0,30 m). Há mais de dez anos, o milho é a principal cultura cultivada no período da safra nas três áreas: sistema de preparo convencional do solo (SPC), com pousio (vegetação espontânea) na entressafra, sistema semeadura direta (SSDE) com pousio (vegetação espontânea) na entressafra e sistema de semeadura direta (SSDM), com cultivo de milho na entressafra. Em cada área coletaram-se 20 amostras de solo em cada uma das camadas, 0,00-0,10 m, 0,10-0,20 m e 0,20-0,30 m de profundidade, em dezembro de 2016, cerca de quinze a vinte dias após a semeadura do milho. Os atributos do solo avaliados foram: diâmet... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Conservation cropping systems, such as the direct sowing system, follow as principles, the absence of soil preparation, the formation and maintenance of vegetation cover and the crop rotation. However, when one of the assumptions is not properly adopted there may be changes in soil structure and, consequently, in soil-plant relationships.. Thus, the objective was to evaluate the physical attributes and soil organic carbon in na area with soil preparation and fallow in the off season and in areas with no tillage, with fallow and with cultivation in the off season. The areas with distinct cultivation systems were located close to the geodesic coordinates 21°14'05'S, 48°17'05'W average altitude of 550 meters with Aw type climate. The soil of the three areas was characterized Red Latosol of clay texture (539 g kg-1 of clay in the layer of 0.00-0.30 m). For more than ten years, maize has been the main cultivated crop during the season in the three areas: conventional tillage system (CTS), fallow in the off season, direct sowing system (DSSS) with fallow (spontaneous vegetation) in the off season, and direct sowing system (DSSC) with corn crop in the off season. In each area 20 soil samples were collected in each of the layers, 0.00 - 0.10 m, 0.10 - 0.20 m and 0.20 - 0.30 m depth, in December 2016, about from fifteen to twenty days after sowing the corn. The soil attributes evaluated were: weighted average diameter of aggregates, aggregate classes, aggregate stability index, soil... (Complete abstract click electronic access below) / Mestre
46

Desenvolvimento e validação de métodos SPE-LC-MS e MEPS-LC-MS para quantificação de fluoroquinolonas em matrizes aquosas / Development and validation of methods SPE-LC-MS and MEPS-LC-MS for determination of fluoroquinolones in water samples

Amparo, Maura Roquete 19 April 2013 (has links)
Os antimicrobianos, especialmente a classe das fluoroquinolonas (FQs), são utilizados em grandes quantidades na medicina humana e veterinária. Uma atenção especial deve ser dada à ocorrência desses fármacos em diferentes matrizes ambientais, devido a potencialidade de propagação da resistência bacteriana. As principais fontes dessa contaminação são os esgoto industrial, urbanos, esgoto sanitário de hospital e de fazendas que utilizam antibióticos com finalidades veterinárias. Após a ingestão, os antimicrobianos são excretados na sua forma inalterada e, devido a baixa eficiência dos sistemas convencionais de tratamento de esgoto, são eventualmente liberados para o meio aquático. Diferentes métodos têm sido desenvolvidos para a determinação de FQs em amostras aquosas diversas, tais como esgoto sanitário , água de abastecimento, águas superficiais e esgoto sanitário de hospital. A maior parte dessas amostras ambientais é complexa e exige uma série de etapas de preparo, limpeza e pré-concentração; de maneira que, nos últimos anos, extensos esforços têm sido feitos para o desenvolvimento de novas técnicas de preparo de amostra que reduzam o tempo, trabalho, consumo de solvente e que permitam melhor desempenho do processo analítico. Nesse estudo foram desenvolvidos dois métodos de extração - a extração em fase sólida (SPE ) e a microextração por sorvente empacotado (MEPS) - sendo a separação, identificação e quantificação feitos por HPLC-MS/MS. Os métodos foram avaliados e validados segundo os parâmetros: precisão, exatidão, recuperação, linearidade, limite de detecção (LD), limite de quantificação (LQ), seletividade, efeito matriz, eficiência total do processo e robustez. Posteriormente, foi feita aplicação dos métodos desenvolvidos para investigação de FQs em águas superficiais e amostra de esgoto coletadas em diferentes pontos da cidade de São Carlos-SP. Os métodos apresentaram valores de recuperação maiores que 80% para as FQs estudadas, e valores de exatidão e precisão menores que 30% . A comparação entre as técnicas de extração desenvolvidas permitiu listar vantagens e desvantagens particulares de cada técnica. Além do menor consumo de solventes e volume de amostras, valores insignificantes de efeito matriz foram alcançados para a técnica MEPS; no entanto a SPE, devido ao seu maior fator de concentração, permitiu a quantificação de duas fluoroquinolonas em amostra de esgoto doméstico e detecção das mesmas em amostra de rio. / Antimicrobials, particularly the fluoroquinolones (FQs) class, are widely used in human and veterinary medicine. Particular attention must be given to the occurrence of these drugs in different environmental matrices, due to the potential spread of bacterial resistance. Effluents from industries, residential districts, hospitals and animal farms are the main sources of contamination by antibiotics. After ingestion, the antimicrobials are excreted in its unchanged form. Due to the low efficiency of conventional wastewater treatments, these antimicrobials are eventually released into the aquatic environment. Several methods have been developed for the determination of FQs in different water samples, such as municipal wastewater, tap water, river water, and hospital sewage. Most of these environmental samples is complex and requires a number of preparation steps, cleaning and preconcentration. For this reason, recently, extensive efforts have been made to develop new techniques for sample preparation in order to reduce: time, number of steps, solvent consumption and achieve better performance on the analytical process. This work describes the development of two methods of extraction - by solid phase extraction (SPE) and microextraction by packed sorbent (MEPS) - and separation, identification and quantification by HPLC-MS/MS. These methods were evaluated and validated by studying the following parameters: accuracy, precision, recovery, linearity, limit of detection (MDL), limit of quantification (MQL), selectivity, matrix effect, process efficiency and robustness. These methods were subsequently applied for FQs investigation in surface water and sewage sample collected at different points in the city of Sao Carlos/SP, Brazil. The methods recoveries achieved values greater than 80% for the studied FQS and the accuracy and precision values were satisfactory when compared to the values acceptable by regulatory agencies such as EPA and AOAC. A comparison between the extraction techniques developed allowed listing advantages and disadvantages of each particular technique. Besides the lowest solvent consumption and volume of samples, negligible values of matrix effects were achieved for MEPS technique. However, SPE, due to its higher pre-concentration, allowed the quantification of two fluoroquinolones in a sample of sewage and the detection in river sample.
47

Síntese e propriedades do copolímero anfifílico poli(3-hidroxibutirato)-bloco-poli(óxido de etileno) e preparação de nanopartículas. / Synthesis and properties amphiphilic copolymer poly(hydroxybutyrate)-block-poly(ethylene oxide) and preparation nanoparticles.

Almeida, Lilian Lacerda de 02 December 2011 (has links)
Visando o crescente interesse em pesquisa de novos materiais que utilizam polímeros biodegradáveis, este presente trabalho teve como objetivo a síntese de novos copolímeros através da reação de transesterificação no estado fundido entre poli(3-hidroxibutirato) (PHB), um polímero biodegradável, com poli(etileno glicol) (PEG). Sabe-se que um dos grandes problemas no uso do PHB é a sua elevada cristalinidade e instabilidade térmica, pois possui temperatura de fusão entre 170 e 180°C e apresenta degradação térmica a 190°C. A reação de transesterificação é uma alternativa para fazer a modificação química deste polímero, o que também viabiliza a formação de copolímeros anfifílicos triblocos. O objetivo final foi utilizar este novo material para o preparo de nanopartículas poliméricas a partir do método de difusão do solvente. Tais partículas são utilizadas para microencapsulamento de fármacos. Os copolímeros foram sintetizados e caracterizados por ensaio de solubilidade, espectrometria de ressonância magnética nuclear de hidrogênio (RMN), calorimetria diferencial exploratória (DSC), espectroscopia no infravermelho com transformada de Fourier (FTIR), cromatografia de permeação em gel (GPC), análise por difração de Raios-X (WAXS), microscopia ótica de luz polarizada (MOLP) e microscopia eletrônica de varredura (MEV). A indicação de formação de copolímero anfifílico pode ser observada nos ensaios de solubilidade, pois o copolímero mostrou-se parcialmente solúvel em uma série de solventes em que o PHB original é insolúvel. A modificação química pode ser observada com as técnicas de RMN e FTIR, cujos espectros apresentaram absorções referentes ao grupo carbonila da ligação éster. As técnicas de DSC, WAXS e MOLP mostraram uma ligeira redução na cristalinidade do material, além da temperatura de fusão reduzir-se de 171ºC para 154°C. Com o GPC observou-se uma redução da massa molar, o que facilita a formação das nanopartículas poliméricas. As nanopartículas apresentaram tamanhos com diâmetros ao redor de 250nm, quando observadas por MEV. / Aimed at the growing interest in research on new materials using biodegradable polymers, the present work was aimed at the synthesis of new copolymers through transesterification reaction in the molten state of poly (3-hydroxybutyrate) (PHB), a biodegradable polymer, poly (ethylene glycol) (PEG). It is well known that a major problem in the use of PHB is its high crystallinity and thermal instability, as it has melting temperature between 170 and 180° C and shows thermal degradation at 190°C. The transesterification reaction is an alternative to the chemical modification of this polymer, which also enables the formation of amphiphilic triblock copolymers. The mainly goal of this studies was to use this new material for the preparation of polymeric nanoparticles from the solvent diffusion method. Such particles are used for microencapsulation of drugs. The copolymers were synthesized and characterized by solubility test, Nuclear Magnetic Resonance Spectroscopy of Hydrogen (NMR), Differential Scanning Calorimetry (DSC), Infrared Spectroscopy with Fourier transform (FTIR), Gel permeation chromatography (GPC) analysis by X-ray diffraction (WAXS), polarized light optical microscopy (MOLP) and scanning electron microscopy (SEM). The signs of the formation of amphiphilic copolymer can be observed in the trials of solubility, since the copolymer was found to be partially soluble in a variety of solvents in the original PHB is insoluble. The chemical modification can be observed with the techniques of NMR and FTIR spectra which showed absorptions for the carbonyl group of the ester linkage. The techniques of DSC, WAXS and MOLP showed a decrease in crystallinity of the material in 15%, and reduce the melting temperature is 171ºC to 154°C. With the GPC showed a reduction in molar mass, which facilitates the formation of polymeric nanoparticles. The nanoparticles showed sizes with diameters around 250nm observed by SEM.
48

Conicidade de preparos para coroas totais: acompanhamento de estudantes de Odontologia / Taper preparations for full crowns: monitoring of dental students

Lopes, Livia Duarte Santos 29 April 2011 (has links)
A avaliação do processo ensino-aprendizagem constitui uma etapa importante da prática docente que visa interpretar os conhecimentos, habilidades e atitudes dos alunos e proporcionar melhorias nos objetivos educacionais. Com intuito de acompanhar o desempenho de estudantes da Faculdade de Odontologia de Bauru da Universidade de São Paulo na área de Prótese Dentária, a conicidade dos preparos para coroas totais realizados por alunos do segundo ano da graduação: grupo 1 (G1), terceiro ano da graduação: grupo 2 (G2) e pós-graduação: grupo 3 (G3) foi mensurada. Foram avaliados 174 preparos, sendo 112 dentes artificiais preparados por G1, 30 troquéis de dentes preparados por G2 e 32 troquéis de dentes preparados por G3. A conicidade mesio-distal (MD) e vestibulo-lingual (VL) de cada preparo foi medida com auxílio do microscópio digital Dino Capture AM 313T. As médias de conicidade total no sentido mesio-distal (MD) foram, no G1: 11,13° para dentes anteriores e 14,21° para dentes posteriores, G2: 20,47° para dentes anteriores e 21,34° para dentes posteriores e G3: 8,75° para dentes anteriores e 12,54° para dentes posteriores. No sentido vestíbulo-lingual (VL) as médias de conicidade total dos preparos realizados foram no G1: 24,08° para dentes anteriores e 13,8° para dentes posteriores, G2: 25,5° para dentes anteriores e de 21,14° posteriores para dentes posteriores e G3: 16,28° para dentes anteriores e 14,13° para dentes posteriores. Maiores valores de conicidade foram encontrados em preparos realizados pelos alunos do terceiro ano da graduação (22,11°), quando comparados com os ângulos encontrados pelos alunos do segundo ano da graduação (15,80°) e pós-graduação (12,92°). Os resultados oferecem dados à comunidade odontológica internacional para estudos comparativos e possibilitam traçar considerações sobre a transmissão de conhecimento em relação à conicidade de preparos. / The evaluation of teaching-learning process constitutes an important step in teaching practice that seeks to interpret the knowledge, skills and attitudes of students and provide improvements in educational goals. For tracking the students performances from the Dentistry School in Bauru, from the University of São Paulo, in Prosthodontics, the taper for the full crowns preparations made by students of the second year of graduation (G1), the third year of graduation (G2) and postgraduate students (G3) was measured. 174 preparations were assessed, being 112 artificial teeth prepared by G1, 30 stone dies of teeth prepared by G2 and 32 stone dies of teeth prepared by G3. The mesiodistal and faciolingual taper from each preparation was measured with the aid of digital microscope Dino Capture AM 313T. The average total taper towards mesiodistal was G1:11.13° for anterior teeth and 14.21° for posterior teeth, G2: 20.47° for anterior teeth and 21.34 ° for posterior teeth and G3: 8.75° for anterior teeth and 12.54° for posterior teeth. In faciolingual view, the taper averages were for G1: 24.08° for anterior teeth and 13.8° for posterior teeth, G2: 25.5° for anterior teeth and 21.14° for posterior teeth and G3: 16.28° for anterior teeth and 14.13° for posterior teeth. Larger taper values were found in preparations made by the students of the third year of graduation (22.11°), when compared to the angles found by students of the second year (15.80°) and postgraduate students (12.92°). The results provide data for the International Dental community for comparative studies and enable trace considerations about the transmission of knowledge in relation to taper preparations.
49

Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica / Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation

Silva, Ricardo Virgolino Carvalho da 16 April 2010 (has links)
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários / The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
50

Desenvolvimento e validação de métodos analíticos para avaliação da remoção de sulfonamidas no tratamento de águas residuárias em reatores biológicos de leito fixo / Development and validation of analytical methods for assessing the removal of sulfonamides in the treatment of wastewater in fixed bed biological reactors

Carvalho, Lucas Sponton de 10 January 2014 (has links)
A presença de antibióticos no ambiente evidencia o problema do descarte inadequado de resíduos farmacêuticos e da ineficiência dos atuais sistemas de tratamento de resíduos. Como consequência a essa contaminação há a possibilidade de resistência microbiana e de outros efeitos nocivos, ainda não completamente compreendidos, sobre a fauna e flora aquática. O presente trabalho teve como um dos objetivos desenvolver métodos de preparo de amostra e análise para avaliar o potencial de um reator anaeróbio de leito fixo para a remoção de sulfonamidas de matrizes complexas, além de investigar possíveis resíduos dessa classe em diversos compartimentos ambientais da cidade de São Carlos. Para isso, métodos utilizando extração em fase sólida (SPE) e cromatografia líquida (LC) foram desenvolvidos em associação à análise por espectrometria de massas. Os resultados mostraram que o reator utilizado consegue remover satisfatoriamente o composto investigado, podendo ser, futuramente, uma alternativa aos tratamentos convencionais. Tais resultados foram obtidos a partir do desenvolvimento e validação de um método utilizando detecção por um analisador híbrido do tipo quadrupolo-tempo de voo (SPE-LC-QTOF). Outro método, baseado em SPE-LC-QTRAP (analisador híbrido quadrupolo-aprisionador de íons linear), foi validado visando mostrar que existe contaminação por sulfonamidas e trimetoprima em águas de córregos coletadas em algumas regiões da cidade. Tal objetivo foi atingindo, permitindo inclusive a comparação entre as figuras de mérito obtidas durante a validação dos métodos, que indicou que os analisadores (e os sistemas utilizados, em geral) possuem diferenças significativas que influem em parâmetros como o efeito de matriz, os limites de quantificação e a sensibilidade.<br/> Paralelamente aos métodos convencionais, alternativas de preparo e análise que reduziam a necessidade de grandes volumes de amostra e solventes também foram desenvolvidos. A associação de técnicas miniaturizadas de preparo de amostra e análise permitiu que limites de detecção comparáveis aos dos métodos utilizando SPE fossem atingidos, utilizando, inclusive, o analisador do tipo tempo de voo. Dessa forma, um novo escopo de aplicações usufruindo das características deste último analisador poderá ser desenvolvido a partir da melhor pré-concentração proporcionada pelas estratégias de miniaturização estudadas. / The presence of antibiotics in the environment demonstrates the problem of improper drug disposal and inefficiency of the current water treatment systems. As a result of this contamination, there is the possibility of microbial resistance and other harmful effects, not totally understood, on the aquatic flora and fauna. The present study aimed to develop methods for sample preparation and analysis in order to evaluate the potential of an anaerobic fixed bed reactor for removing sulfonamides from complex matrices and, in addiction, to investigate the presence of this class of contaminants in various environmental compartments of São Carlos. For this, methods using solid phase extraction (SPE) and liquid chromatography (LC), were developed in association with the analysis by mass spectrometry . The results showed that the reactor used can satisfactorily remove the compound investigated and may be, in future, an alternative to conventional treatments. These results were obtained from the development and validation of a method based on solid phase extraction associated with liquid chromatography coupled to mass spectrometry using a hybrid quadrupole-time of flight (SPE-LC-QTOF) analyzer. Another method that was also developed and validated, based on SPE-LC-QTRAP (hybrid quadrupole-linear ion trap), was useful to show that there is contamination by sulfonamides and trimethoprim in water collected from rivers in some areas of the town. This objective was achieved, inclusive allowing the comparison between the figures of merit obtained during the methods validation, which indicated that the analyzers (and the systems used, in general) have significant differences which that affect parameters as matrix effect and quantification limits.<br/> In parallel with the conventional methods, alternatives of sample preparation and analysis that reduced the need of large volumes of sample and solvent were also developed.<br/> The association of miniaturized techniques of sample preparation and analysis allowed detection limits comparable to that of methods using SPE, even using small volumes of sample and solvent and a less sensitive mass analyzer. Thus, a new scope of applications, taking advantage of the characteristics of the QTOF, can be developed from the higher pre-concentration provided by the strategies studied in this work.

Page generated in 0.1168 seconds