• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • Tagged with
  • 52
  • 52
  • 52
  • 31
  • 31
  • 28
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia do ionomero de vidro da resina composta na sustentação do esmalte e seu efeito na rigidez, deflexão e resistencia a fratura das cuspides dos dentes restaurados

Secco, Angelo Stefano 30 August 1995 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T15:58:57Z (GMT). No. of bitstreams: 1 Secco_AngeloStefano_M.pdf: 3238589 bytes, checksum: afa95602c2fed0a7ae9a1b3cfbe97556 (MD5) Previous issue date: 1995 / Resumo: O objetivo deste trabalho foi analisar a influência do cimento de ionômero de vidro e da resina composta na sustentação do esmalte sem apoio de dentina, assim como, os efeitos na rigidez, deflexão e resistência à fratura das cúspides dos dentes restaurados. Foram utilizados 42 pré-molares superiores recentemente extraídos, mantidos hidratados e divididos em 6 grupos de 7 dentes: 1 - Dente hígido; 2 - Classe II MO; 3 - Classe II mais remoção da dentina de suporte do esmalte oclusal; 4 - Idem grupo 3, com esmalte oclusal suportado com ionômero de vidro Ketac Bond, (ESPE); 5 - Idem grupo 3, com esmalte oclusal suportado com Vitremer (3M); e, 6 - Idem grupo 3, com esmalte oclusal suportado com resina Z100 (3M). Em todos os grupos antes dos tratamentsos iniciarem e após cada tratamento foram realizadas leituras de extensiometria com os extensômetros colados na superfície vestibular e língual de cada dente, aplicando-se uma carga de 12kg na oclusal dos dentes através da máquina Instron regulada à uma velocidade de 0,05mm/s. Os dados obtidos foram utilizados para os cálculos da variação da rigidez e deflexão das cúspides após cada tratamento. Após a realização desse teste, os dentes foram submetidos ao ensaio de resistência à fratura. Os resultados foram submetidos à análise de variância e ao teste de Tukey. Os resultados indicaram que a resina composta suportando esmalte, recuperou 65% da rigidez das cúspides, perdida com o preparo cavitário e diminuiu a deflexão em 75%, não diferindo do dente hígido (p<0,05); o ionômero fotopolimerizável recuperou 25% da rigidez e diminuiu em 42% a deflexão, não atingindo estatisticamente os valores do dente hígido, porém, foi melhor que o preparo classe II com remoção de dentina no dente não restaurado (p<0,05). O ionômero convencional apresentou o pior desempenho: recuperou apenas 16% da rigidez e dirninuiu em 22% a deflexão, porém, não diferiu do preparo classe II com remoção de dentina e não restaurado. Nenhuma condição restauradora recuperou os valores de resistência à fratura das cúspides do dente hígido (p>0,01). No entanto, todos os materiais suportando esmalte aumentaram a resistência à fratura do esmalte oclusal suportado artificialmente. E a resina composta demonstrou, dentre todos eles, ser o material mais mdicado para suportar esmalte, em função da recuperação da rigidez, deflexão e aumento da resistência à fratura do esmalte suportado / Abstract: The purpose of this study was to evaluate the influence of glass ionomer and composite resin to conserve unsupported enamel, as well as to evaluate the effect of cuspal stiffness, flexure, and strength of restored teeth against fracture. Forty-two freshly extracted maxillary premolars were selected for using in this study. Cuspal stiffness and flexure were assessed using a strain gauge bonded to buccal and lingual surfaces. Cuspal stiffness and flexure were evaluated in sequentially performed procedures: 1. unaltered tooth, 2. MO cavity preparation, 3. removal dentin of supporting occlusal enamel in class II preparation, 4. glass ionomer Ketac Bond (ESPE) and Vitremer (3M) and composite resin Z100 (3M) supporting occlusal enamel. Each tooth was loaded with a 12 kg force, at a speed of 0,05 rnm/rnin in Instron test machine. After nondestructive test, the teeth were subjected to fracture resistance test. The data were analyzed using a one way ANOVA, and Tuckey's test. Results indicated that composite resin supporting enamel recovered 65% of the lost cuspal stiffness with the cavity preparation and the flexure was decreased in 75%, similarly to the unaltered tooth (p<0.05); the light-cured glass ionomer recovered 25% of lost cuspal stiffness and flexure was diminished in 42%, it was significantly lower than unaltered tooth, better than the prepared and unrestored one (p<0.05); the auto-cured glass ionomer recovered 16% of the lost cuspal stiffness and the flexure was decreased in 22%. The difference was not significant when compared to the unrestored teeth. This study concluded that all the restorative materials supporting enamel increased the fracture resistance of artificial supported enamel and composite resin was the best restorative material to support the enamel concerning to cuspal stiffness and flexure / Mestrado / Materiais Dentarios / Mestre em Ciências
2

Efetividade de diferentes métodos mecânicos de remoção de dentina cariada : avaliação através de micro-CT e imagem digital / Effectiveness of different mechanical methods on dentin caries removal : micro-CT and digital image evaluation

Ferraz, Camila de Ataíde e January 2013 (has links)
FERRAZ, Camila de Ataíde e. Efetividade de diferentes métodos mecânicos de remoção de dentina cariada : avaliação através de micro-CT e imagem digital. 2013. 70 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2013-05-23T11:23:45Z No. of bitstreams: 1 2013_dis_caferraz.pdf: 971753 bytes, checksum: f30fedfb1919a17df888730670942429 (MD5) / Approved for entry into archive by Erika Fernandes(erikaleitefernandes@gmail.com) on 2013-05-23T13:46:43Z (GMT) No. of bitstreams: 1 2013_dis_caferraz.pdf: 971753 bytes, checksum: f30fedfb1919a17df888730670942429 (MD5) / Made available in DSpace on 2013-05-23T13:46:43Z (GMT). No. of bitstreams: 1 2013_dis_caferraz.pdf: 971753 bytes, checksum: f30fedfb1919a17df888730670942429 (MD5) Previous issue date: 2013 / A remoção seletiva de dentina cariada é um desafio para a Odontologia contemporânea, já que os métodos tradicionais de escavação podem remover, além do tecido cariado, dentina sadia. Objetivou-se determinar a efetividade de remoção de cárie (ERC) e o potencial minimamente invasivo (PMI) de três métodos mecânicos de escavação. Doze molares humanos com lesões de cárie oclusal em dentina foram distribuídos, de forma randomizada, em três grupos de acordo com o método de remoção: broca carbide, cureta de dentina e broca de polímero. Todos os dentes, antes de serem submetidos à etapa de escavação da cárie, tiveram suas raízes embutidas em resina acrílica. Seccionaram-se os dentes uma única vez no sentido longitudinal, tendo como referência visual o centro da lesão. Cada uma das secções foi submetida a fotografias digitais padronizadas e escaneamento por microtomografia computadorizada de raios-X (micro-CT) (Skyscan 1174, Skyscan, Kontich, Belgium) em dois momentos distintos, antes e após a remoção de cárie. Utilizou-se um programa de imagens de domínio público, ImageJ, para análise das imagens obtidas. Definiram-se as áreas de dentina cariada inicial (CI), da cavidade preparada (CP) e da cárie residual (CR) nas fotografias e nas imagens de micro-CT de acordo com critério visual. Determinou-se a ERC entre os métodos com base na relação CR/CI, enquanto o PMI foi determinado através da relação entre CP/CI. Analisaram-se os dados obtidos através de Análise de Variância a Um Critério e teste-t de Student ou Kruskal-Wallis e teste Student-Newman-Keuls. Tanto para a análise de imagem digital quanto para a análise de micro-CT, a broca carbide apresentou maior efetividade em relação à cureta (p=0,0063; p=0,0263, respectivamente) e em relação à broca de polímero (p=0,0028; p=0,0005, respectivamente), enquanto que cureta de dentina e broca de polímero mostraram resultados semelhantes para os dois tipos de imagens (p>0,05). Em relação ao PMI, para a análise de imagem digital, a broca de polímero apresentou-se como método com potencial invasivo similar à cureta de dentina (p=0.1240), porém com invasividade menor do que a broca carbide (p=0,0028). Para a análise de micro-CT, os valores de PMI de todos os grupos foram significantemente diferentes, e a broca de polímero também demonstrou o método mais conservador, tanto em relação à cureta de dentina (p=0,0030), quanto em relação à broca carbide (p<0.001). Portanto, a broca carbide foi o método mais efetivo para remoção de cárie, porém o menos conservador; e a broca de polímero apresentou baixo potencial invasivo, porém não foi capaz de remover toda a dentina cariada.
3

Avaliação do método de preparo cavitário na integridade marginal e resistência de união de sistemas adesivos à dentina humana / Effect of cavity preparation methods on marginal integrity and bonding strength of dental adhesives

Barros, Lívia de Oliveira January 2015 (has links)
BARROS, Lívia de Oliveira. Avaliação do método de preparo cavitário na integridade marginal e resistência de união de sistemas adesivos à dentina humana. 2015. 71 f. Tese (Doutorado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by denise santos (denise.santos@ufc.br) on 2016-03-17T11:12:30Z No. of bitstreams: 1 2015_tese_lobarros.pdf: 23954864 bytes, checksum: cdf1749fe68dbae47a1e7b8beae18eb9 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2016-03-17T11:31:34Z (GMT) No. of bitstreams: 1 2015_tese_lobarros.pdf: 23954864 bytes, checksum: cdf1749fe68dbae47a1e7b8beae18eb9 (MD5) / Made available in DSpace on 2016-03-17T11:31:34Z (GMT). No. of bitstreams: 1 2015_tese_lobarros.pdf: 23954864 bytes, checksum: cdf1749fe68dbae47a1e7b8beae18eb9 (MD5) Previous issue date: 2015 / Smear layer (SL) is an amorphous layer of organic and inorganic debris formed on the surface of dentin after mechanical preparation of a cavity with rotating or manual instruments. The cavity preparation method and micromorphological characteristcs of SL and underlying dentin surface, might affect the adhesive performance. The current study is divided in two chapters, whose aims: 1) To evaluate the effect of dentin surface preparation method on micromorphological characteristics of dentin surface and on the microtensile bond strength (μTBS) of two adhesive systems to dentin. (Chapter 1); 2) To evaluate the effect of cavity preparation method on marginal integrity and sealing ability of resin-tooth interface produced by two adhesive systems (Chapter 2). Standardized class I cavities (5 x 4 x 3 mm), with margins in enamel, were prepared in sound extracted human molars, according to the preparation method (n=20): (1) Medium grit diamond bur; (2) Medium grit diamond bur followed by extra-fine grit diamond bur; (3) 12 blades Tungsten carbide bur and (4) 12 blades Tungsten carbide bur followed by 30 blades Tungsten carbide bur. Composite restorations were inserted in cavities after AdperTM ScotchbondTM Multipurpose (SBMP) or ClearfilTM SE Bond (CSE) application. Epoxy replicas of restorations were obtained after 20,000 thermo-mechanical cycles. Resin-dentin bonded sticks were prepared for μTBS testing, pulled until failure at crosshead speed of 0.5 mm/min and failure pattern was evaluated (Chapter 1). For evaluated of restorations marginal integrity, epoxy replicas were observed under scanning electron microscope (SEM) to analysis of the percentage of gap-free margins (Chapter 2). Additional teeth (n=16) were prepared using same groups tested and investigated by SEM to micromorphological qualitative analysis of dentin surface and SL characteristics (Chapter 1). Extra teeth (n=48) were prepared, restored and then immersed in 2% methylene blue for dye penetration analysis (Chapter 2). Under SEM analysis, medium grit diamond bur produced thicker SL and more irregular dentin surface than Tungsten carbide burs. SBMP adhesive yielded the highest μTBS when medium grit diamond bur was used and for CSE 30 blades Tungsten carbide bur group showed the highest values (p<0.05) (Chapter 1). Cavity preparation methods did not affect the percentage of gap-free margins and dye penetration for SBMP (p>0.05). CSE exhibited the highest percentage of gap-free margins and lowest dye penetration when medium grit diamond bur was used (p<0.05) (Chapter 2). Dentin surface preparation 24 method affected SL characteristics, dentin surface topography, subsequently, resin- dentin bond strengths. Dentin surface irregularity was able to improve resin-dentin bond performance for SBMP. SL thickness and irregularity may compromise bonding efficacy of the self-etching system. The influence of the cavity preparation method on the marginal integrity and sealing ability were dependent of the adhesive used, once it affected more the performance of self-etching adhesive. / Smear layer (SL) é uma camada de detritos orgânicos e inorgânicos que recobre a superfície dentária após a confecção de um preparo cavitário. O método de preparo cavitário e, consequentemente, as características micromorfológicas da SL podem afetar o desempenho dos sistemas adesivos. Este estudo foi dividido em dois capítulos, cujos objetivos foram: 1) Avaliar o efeito do método de preparo cavitário nas características micromorfológicas da superfície dentinária e na resistência de união (RU) de sistemas adesivos à dentina (Capítulo 1); 2) Avaliar o efeito do método de preparo cavitário na adaptação e selamento marginal da interface esmalte/restauração produzida por dois sistemas adesivos (Capítulo 2). Foram utilizados oitenta molares humanos hígidos extraídos nos quais foram confeccionadas cavidades padronizadas classe I (5 X 4 x 3 mm), com margens em esmalte, de acordo com o método de preparo cavitário utilizado: (1) Ponta diamantada de média granulação; (2) Ponta diamantada de média granulação seguida por ponta diamantada de granulação extra- fina; (3) Broca carbide de 12 lâminas e (4) Broca carbide de 12 lâminas seguida por broca carbide de 30 lâminas. Incrementos de resina composta foram inseridas nas cavidades após a aplicação dos sistemas adesivos Adper® Scotchbond® Multipurpose (SBMP) e Clearfil® SE Bond (CSE). Réplicas de resina epóxica da superfície oclusal das restaurações foram obtidas após serem submetidas 20.000 ciclos termomecânicos. Os espécimes foram cortados para obtenção de palitos da interface resina-dentina que foram testados em microtração e classificados conforme o padrão de fratura (Capítulo 1). As réplicas foram analisadas em MEV para avaliação de microfendas marginais (Capítulo 2). Dentes adicionais (n=16) foram preparados para avaliação qualitativa em MEV das características micromorfológicas da SL e da superfície dentinária (Capítulo 1). Outros dentes (n=48) foram submetidos aos mesmos procedimentos restauradores descritos acima e imersos em solução de azul de metileno a 2% para avaliação da microinfiltração marginal (Capítulo 2). Para cada teste foi aplicada a análise estatística apropriada. Avaliação qualitativa em MEV revelou SL mais espessa e superfície dentinária mais irregular para as pontas diamantadas quando comparadas as brocas carbide. O método de preparo cavitário afetou a RU de ambos sistemas adesivos. A ponta diamantada de média granulação apresentou os maiores valores de RU para SBMP e a broca carbide de 30 lâminas para CSE (p<0,05) (Capítulo 1). Os 22 métodos de preparo cavitário não afetaram a porcentagem de fendas marginais e a quantidade de microinfiltração marginal para o SBMP (p>0,05). CSE apresentou a maior porcentagem de margens livres de fendas e menor microinfiltração marginal (p<0,05) quando utilizado com ponta dimantada de média granulação (Capítulo 2). O método de preparo cavitário afeta as características da SL, da micromorfologia dentinária e, consequentemente, a RU. Superfícies dentinárias mais irregulares promoveram melhores valores de RU com o SBMP. Por outro lado, a irregularidade e a espessura da SL parecem comprometer o desempenho do sistema autocondicionante. O efeito do método de preparo cavitário no selamento e na adaptação marginal dependeu do sistema adesivo utilizado, uma vez que afetou mais o sistema adesivo autocondicionante.
4

Estrutura do esmalte humano e sua interface com sistemas adesivos /

Moraes, Marcelo Fava de. January 2007 (has links)
Resumo: Esta tese sistematiza uma série de estudos dedicados à compreensão da interface do esmalte e sistemas adesivos. Para tanto, a estrutura da camada aprismática do esmalte em alta resolução pela microscopia eletrônica de varredura foi avaliada quanto a sua continuidade, espessura, distribuição nas faces coronárias e em fossas e fissuras, predominantemente em dentes decíduos não erupcionados. Foi também analisado pela microscopia eletrônica de varredura os efeitos do condicionamento de diferentes tipos de ácido e, em especial, do ácido fosfórico em diferentes concentrações, metodologias e tempos de aplicação. Estes trabalhos permitiram visualizar as principais ações ácidas desmineralizantes e os tipos de retenções no centro ou periferias dos prismas ou em ambas as regiões, bem como a profundidade e forma dos "tags" resinosos com carga e sem carga na intimidade do esmalte. No caso particular da aplicação dos selantes em fossas e fissuras foi também avaliada comparativamente a eficácia das técnicas invasivas ou não invasivas. Os últimos experimentos foram dedicados ao estudo da microinfiltração de diferentes sistemas adesivos e da resistência destes sistemas adesivos na estrutura do esmalte. Novos estudos merecem dar continuidade à linha de pesquisa de sempre priorizando o propósito de vincular os procedimentos aplicados com uma consistente e indispensável fundamentação de pesquisa básica no interesse da clínica odontopediátrica. / Abstract: This thesis represents a systematization of several previsious papers related to the understanding of the interface between dental enamel and adhesive systems. Specific research was dedicate to the prismless layer using the scanning electron microscopy with the evaluation of its thickness, continuity, coronal distribuition and presence or absence in pits and fissures. The non-erupted deciduous teeth received priority attention. The scanning electron microscopy was also the methodology elected to study the effects of the acid etching mainly with phosphoric acid under different concentrations, methodologies and application times. It was possible to observe the essential demineralization effects by the acid performance and the various types of retentions promoted in the prism core (head), interprismatic periphery or in both areas. The shape and depth of the resinous tags (filled or unfilled) in the structure of the enamel was also determined. In relation to the sealant application and its effectiveness in coronal pits and fissures it was also evaluated by comparison between invasive and non-invasive techniques. The purpose of the most recent investigations was the microleakage study among different adhesive systems, as well as, the shear bond strength of the adhesives in the enamel structure. New studies must be developed in our research program with the same priority for the pedodontics improvement considering questions from clinical procedures with a substancial background of basic research.
5

Avaliação da forma de preparos cavitários confeccionados a partir do sistema CVDentus /

Josgrilberg, Érika Botelho. January 2005 (has links)
Resumo: Foi avaliado a morfologia de preparos cavitários realizados com o sistema CVDentus® variando-se a potência do ultra-som. As cavidades foram preparadas com a ponta cilíndrica modelo 8.2142, na face vestibular de 15 incisivos bovinos, que foram divididos em 3 grupos: G1 utilizando a potência II do aparelho de ultra-som, G2 a potência III e G3 potência IV do mesmo aparelho, na máquina padronizadora de preparos cavitários durante 1 minuto para cada preparo. Após, os preparos foram seccionados ao meio obtendo-se duas hemi-faces com seus perfis, que foi observado em Lupa Estereoscópica e medidos por meio do programa Leica Qwin. De acordo com os testes estatísticos Kruskal-Wallis e método de Dunn, houve diferença entre a largura e a profundidade dos preparos somente quando comparados às potências III e IV do aparelho de ultrasom, e que a largura da cavidade realizada pela potência III é a mais semelhante ao diâmetro real da ponta. Concluiu-se que a potência III indicada pelo fabricante é de fato a mais apropriada para o uso na clínica diária, pois possibilita a realização de preparos conservadores. / Abstract: This study has evaluated the shape of dental cavities made by CVDentus® system with ultrasound potency variation. The cavities have been made on buccal face of 15 bovine incisors with acylindrical bur (82142). The sample have been divided into three groups: G1, using ultrasound power II; G2, using power II, and G3, using power IV with a standard device. The cavities have been sliced in the middle, allowing thereby the cavity's profile observation with magnifying glasses, and measurement with a Leica Qwin program. The Kruskall-Wallis and Dunn statistical analysis has shown differences between dental cavities shapes when power III and IV were used. However, the cavities who have been made with power III were similar to bur dimension. Therefore, we conclude that the manufacturer indication to use power III is more suitable to clinical use because it allows more conservative cavity preparation. / Orientador: Cyneu Aguiar Pansani / Coorientador: Rita de Cassia Loiola Cordeiro / Banca: Evaldo José Corat / Banca: Silvio Issáo Myaki / Mestre
6

Estabilidade mecanica de proteses fixas sobre retentores do tipo coroa total

Silva, Wilkens Aurelio Buarque e, 1967- 14 November 1996 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T21:22:32Z (GMT). No. of bitstreams: 1 Silva_WilkensAurelioBuarquee_D.pdf: 4715185 bytes, checksum: 2f0fd4a9ae36d7a9ec0b70f8bd967723 (MD5) Previous issue date: 1996 / Resumo: O objetivo deste trabalho foi avaliar a estabilidade mecânica de pontes fixas, através da variação de forças compressivas verticais, de sentido ocluso cervical, aplicadas nas vertentes oclusais internas dos retentores e pônticos; sendo os corpos de prova adaptados em preparos do tipo coroa total, com e sem canaletas axiais proximais e variando-se a convergência das paredes axiais. Os preparos com 5mm de altura cervico-oclusal e ombro maior que 90°, foram confeccionados com as seguintes convergências: 16°, 24° e 32° de convergência total, com e sem canaletas axiais proximais (0,7mm de profundidade e 4mm de altura). Para cada hemi-arco foi confeccionado um corpo de prova com características morfofuncionais de uma ponte fixa, cujos retentores foram o 2° molar e o 2° pré-molar, e pônticos o 1° molar e o 1° pré-molar (pôntico em "cantilever"). Para avaliação da estabilidade mecânica, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg, 15kg e 20kg em uma máquina de ensaio universal, com velocidade' constante em 1mm/min. O registro dos resultados consistiu em observar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) Os retentores adaptados sobre preparos com 12° e 16° em cada parede axial, sem canaletas axiais proximais, obtiveram médias de deslocamento significativamente superiores aos adaptados em preparos com 8°; b) O aumento na intensidade das forças compressivas diminuiu a estabilidade dos corpos de prova. c) As forças induzidas no "cantilever", proporcionaram as maiores médias de deslocamento; d) As canaletas axiais proximais reduziram significativamente as médias de deslocamentos dos corpos de prova nos grupos com 12° e 16° de convergência em cada parede axial; e) As canaletas axiais proximais não foram devidamente efetivas em antagonizar as forças induzidas no "cantilever" / Abstract: The purpousal of this research, was to evaluate the mechanical stability of full crown preparations, over vertical compressive forces, applied in the occlusal vertents of the pontics and retainers of fixed partial prothesis, with or without the presence of proximal axial grooves, changing the convergence of the axial walls. The preparations with sholder larger than 90°, were made with the following convergences: 8°, 12° and 16° in each of the axial walls, with or without proximal axial grooves, of 0,7mm deep and 4mm length. The cervico-occlusal height of the preparations was 0,5mm. For each hemi-archs, was made a pattern like a four elements fixed partial denture: 2nd. molar (retainer), 1st. molar (pontic), 2nd. pre-molar (retainer) and the 1st.pre-molar (cantilever). To evaluate the resistance form of the preparations, the pattern adjusted in yours respective preparations, were submited to vertical forces of intensity 3kg, 5kg, lOkg, 15kg and 20kg in a universal testing machine, with speed in 1mm/min. The record of the results was to observe the occours of dislodgement of the patterns. The obtained results shows: a) the retainers adjusted in 12° and 16° preparations, had statisticaly higher average of dislocation to the adjusted in 8°; b) The increase of vertical force, decreased the the stability; c) The vertical force induced in the cantilever, provides the higher averages of dislocation; d) The proximal axial grooves decreased the average of dislocation, in 12° and 16° preparations groups; e) The proximal axial grooves, were not completely effective in provides stability, on cantilever pontics / Doutorado / Protese Dental / Doutor em Clínica Odontológica
7

Analises histopatologica e imunohistoquimica e amplificação de DNA atraves de Real-Time PCR em carcinoma espinocelular de cavidade oral e em osteossarcoma dos maxilares

Lopes, Márcio Ajudarte, 1967- 03 August 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T13:14:28Z (GMT). No. of bitstreams: 1 Lopes_MarcioAjudarte_LD.pdf: 1399819 bytes, checksum: 17c0aaf29832de33633382b30d6871dd (MD5) Previous issue date: 2001 / Resumo: Não informado / Abstract: Not informed / Tese (livre-docencia) - Univer / Semiologia / Livre Docente em Estomatopatologia
8

Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica / Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation

Silva, Ricardo Virgolino Carvalho da 16 April 2010 (has links)
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários / The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
9

Novas tecnologias x instrumento rotatório convencional: avaliação das variáveis que podem interferir no estado emocional da criança

Josgrilberg, Érika Botelho [UNESP] 17 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-17Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 josgrilberg_e_dr_arafo.pdf: 1774679 bytes, checksum: ae031b6add35dd8be0e61381e81747cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi identificar os estados emocionais indicativos de medo/ansiedade da criança com (CE) ou sem experiência odontológica prévia (SE) frente à utilização de três diferentes formas de realização de preparos cavitários: ultra-som (Sistema CVDentus®), sistema de abrasão a ar (Rondoflex®) e alta rotação (Kavo). Quarenta e oito crianças de 7-11 anos de idade foram divididas aleatoriamente em 2 grupos (CE e SE). O tratamento odontológico compreendeu o preparo cavitário de lesões de cárie oclusal nos dentes 16 e 26, realizados em duas sessões, utilizando Alta Rotação e o Abrasão a ar ou Ultra-som. Durante a consulta a freqüência cardíaca da criança foi aferida nas seguintes situações: sala de espera, ao sentar na cadeira, anestesia, isolamento absoluto, cinco minutos após o início do tratamento e ao final da consulta. Além disso, foi aplicada a escala “Facial Image to assess child dental anxiety - FIS”, antes e após cada atendimento. Para a avaliação do medo da criança foi utilizado o teste “Children Fear Survey Schedule- Dental Subscale (CFSSDS)”. Para a avaliação do comportamento infantil foi utilizada a escala de Frankl. Os resultados obtidos do Teste de Friedman para freqüência cardíaca e para a escala “FIS” não apontaram diferença estatística entre os grupos CE e SE e entre as três tecnologias utilizadas. Entretanto, houve aumento nos batimentos cardíacos ao sentar na cadeira odontológica (p < 0,05). Os resultados obtidos pelo teste CFSS-DS apontou uma amostra homogênea com baixos níveis de medo/ansiedade odontológica. Nenhuma criança apresentou comportamento definitivamente negativo ou negativo. Conclui-se o medo/ansiedade da criança aumenta quando ela senta na cadeira odontológica, porém tende a diminuir no decorrer do tratamento independente da tecnologia utilizada para o preparo cavitário. / The aim of this study was to identify fear/anxiety in children with past dental experience (CE) or not (SE) using three different manner of dental cavity preparation: ultrasound (Sistema CVDentus®), air abrasion system (Rondoflex®) and rotatory instrument (Kavo). Forty eight children, with 8- 12 years old were randomly divided into 2 groups (CE e SE). Dental treatment was realized in two sessions, including dental cavity preparation of occlusal caries on 16 e 26 tooth, using Rotatory Instrument and o Air Abrasion System or Ultrasound. During dental procedures children heart rate was taken, on following situations: waiting room, seating on dental chair, anesthesia, when using rubber dam, 5 minutes after the treatment beginning and on final session. Additionally, a “Facial Image to assess child dental anxiety” (FIS) was uses before and after treatment. To evaluate children dental fear was used the questionnaire “Children Fear Survey Schedule- Dental Subscale (CFSS- DS)”. The comparison of the two groups (CE and SE) and the three technologies use for dental cavity preparation in heart rate study and FIS, submitted to Friedman’s test resulted on no significant difference. However, it was observed higher heart rate when children seats on dental chair (p < 0.05). CFSS-DS results demonstrate a homogeneous sample with lower dental fear/anxiety. It was concluded that children anxiety and fear are higher on sitting on dental chair and tend to diminish during technological devices free treatment.
10

Comparação termométrica entre preparos cavitários realizados com turbinas de alta-rotação e laser de Er:YAG /

Cavalcanti, Bruno das Neves. January 2001 (has links)
Orientador: Sigmar de Mello Rode / Banca: Fernando Ricardo Xavier da Silveira / Banca: Maria Auxiliadora Junho de Araujo / Resumo: O objetivo deste estudo foi comparar as variações de temperatura provocadas por turbinas de alta-rotação e pelo laser de Er:YAG (350mJ/10 Hz). Preparos cavitários classe V foram realizados numa profundidade de 2,0mm em 35 incisivos inferiores bovinos, que tiveram um termopar posicionado para ler as temperaturas no interior da câmara pulpar. A análise foi feita nos seguintes grupos: I - alta-rotação sem refrigeração a água; II - alta-rotação com refrigeração a água; III- laser de Er:YAG sem refrigeração a água; IV- laser de Er:YAG com refrigeração a água. Em todos os grupos foram utilizados dez dentes, com exceção do grupo III, que teve uma amostra de apenas cinco dentes, uma vez que foi impossível realizar os preparos adequadamente com o laser sem refrigeração. Os aumentos de temperatura foram gravados num computador ligados aos termopares e os dados dos grupos I, lI e IV foram submetidos ao teste de Dunn para comparações múltiplas (p<0,05). Os aumentos médios de temperatura foram: 11,64°C para o grupo I, 0,96°C para o grupo II, 40,86°C para o grupo lll e 2,9°C para o grupo IV. Não houve diferenças estatisticamente significantes entre os grupos II e IV, e estes foram diferentes do grupo I. Os preparos cavitários realizados com as turbinas de alta-rotação e com o laser de Er:YAG geraram aumentos de temperatura semelhantes quando sob refrigeração a água. A refrigeração é essencial para evitar aumentos de temperatura agressivos em ambos os casos e com o laser de Er:YAG é especialmente necessária para a ablação do esmalte / Abstract: The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel / Mestre

Page generated in 0.0762 seconds