Spelling suggestions: "subject:"preparo dde canal radicular"" "subject:"preparo dde canal adicular""
1 |
Avaliação da centralização do preparo biomecânico em canais radiculares preparados com os sistemas ProTaper UniversalTM, ProfileTM e Twisted FileTMde Andrade Mendes, Daniela 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:02:04Z (GMT). No. of bitstreams: 2
arquivo962_1.pdf: 2744566 bytes, checksum: 63c273abdb2f642bd8167f8e9e67f0b2 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / O conhecimento da morfologia interna do sistema de canais radiculares e suas diversas conformações têm um importante papel no sucesso da terapia endodôntica. A familiarização com as curvaturas torna-se importante para execução de um correto planejamento do preparo biomecânico dos canais radiculares escolhendo técnicas e instrumentos apropriados para cada situação, uma vez que a manutenção da sua anatomia original é de suma importância para o sucesso da terapêutica aplicada. O preparo biomecânico do sistema de canais radiculares apresenta como objetivo promover a limpeza, modelagem tridimensional e a completa desinfecção do sistema de canais radiculares utilizando instrumentos e soluções que permitam maior precisão e menor tempo de trabalho. Desde sua introdução, os instrumentos endodônticos confeccionados em níquel-titânio (NiTi) vêm sendo largamente utilizados por apresentar grande flexibilidade e capacidade em manter a morfologia original do canal radicular. Instrumentos rotatórios confeccionados com esta liga promovem o alargamento das porções curvas dos canais mantendo a sua anatomia original, provocando menores índices de desvios. Esta pesquisa avaliou a centralização do preparo biomecânico após a instrumentação mecânico-rotatória efetuada por três sistemas rotatórios (ProTaperTM, ProFileTM e Twisted-FileTM) em canais radiculares curvos e a conformação das paredes dentinárias após o preparo biomecânico efetuado pelo sistema ProTaperTM. Diante dos resultados obtidos, pôde-se concluir que: os três sistemas analisados ProTaper, ProFile e Twisted-File foram capazes de realizar o preparo biomecânico centralizado na porção apical do canal radicular provocando pequenas proporções de desvio, não sendo observadas diferenças estatisticamente significantes entre os mesmos; O sistema rotatório ProTaper UniversalTM não foi totalmente eficaz em instrumentar todas as paredes do terço apical dos canais radiculares, apresentando porém uma capacidade aceitável para a modelagem de canais radiculares curvos
|
2 |
Avaliação da resistência à fadiga de instrumentos rotatórios do Sistema Pro Taper Universal por meio de ensaio dinâmicoEstrela, Cristiane Bonanato [UNESP] 30 September 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-09-30Bitstream added on 2014-06-13T19:01:53Z : No. of bitstreams: 1
estrela_cb_dr_arafo.pdf: 281331 bytes, checksum: 5959841f39dd175bb62b91abc670ba79 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste estudo foi avaliar o efeito da velocidade de deslocamento na resistência à fratura por fadiga de instrumentos rotatórios de níquel-titânio por meio de ensaio dinâmico de flexão. Foram avaliados instrumentos S1, S2, F1, F2 e F3 pertencentes ao Sistema ProTaper Universal (Dentsply/Maillefer) sendo 20 de cada número num total de 100 instrumentos, que foram divididos em dois grupos. Todos os instrumentos foram submetidos a ensaio de flexão por meio de um dispositivo elaborado especificamente para este estudo. O aparato para teste foi composto por um canal artificial curvo, fabricado em aço inoxidável temperado e que apresentava 5mm de raio e ângulo de curvatura de 45º. Um motor elétrico X-Smart (Dentsply/Maillefer) com um contra-ângulo com redução de 16:1 foi regulado para trabalhar à uma velocidade constante de rotação de 300rpm e com um torque de 2 N.cm. A este contraângulo foram acoplados os instrumentos ProTaper Universal que foram introduzidos no canal artificial e ali giraram livremente até sua fratura. O aparato regulava a velocidade de deslocamento axial do canal artificial para frente e para trás, na direção dos instrumentos, simulando a entrada e saída dos instrumentos no canal radicular. Foram utilizadas duas velocidades de deslocamento do canal simulado, sendo que os instrumentos do Grupo I foram submetidos à uma velocidade mais lenta (146 deslocamentos por minuto) e no Grupo II a velocidade foi mais rápida (189/min). O tempo até a fratura foi registrado por um cronômetro e, a partir daí, encontrou-se o número de rotações para fratura. A comparação do número médio de ciclos até a fratura foi realizada por meio do teste t de Student para amostras independentes. Os resultados mostraram que ocorreu diferença estatisticamente significante do número médio de ciclos até a fratura apenas para o instrumento F3 (p=0,025)... / The aim of this study was to evaluate the fracture strength under fatigue load of Nickel-Titanium rotatory endodontic instruments by means of a dynamic flexure strength test. The S1, S2, F1, F2 and F3 instruments from the ProTaper Universal System (Dentisply/Maillerfer) were evaluated. Twenty samples of each instrument, totalizing 100 samples, were divided in two groups. All instruments were submitted to the flexure strength test using a device specially developed for this study. The device was composed by a 45º sloped artificial root canal, made with tempered stainless steel, with radius of 5mm. An X-Smart (Dentisply/Maillefer) electric engine that had a contra-angle with rotatory reduction of 16:1 was stated to work with a constant speed of 300rpm and with a torque of 2N.cm. Each ProTaper Universal Instrument was individually attached to the contra-angle and then introduced into the artificial root canal where they rotate freely until failure. The test apparatus also has a potentiometer that was responsible to regulate the axial dislodgment speed of the artificial root canal forward and backward, against instruments direction, simulating the inward and the outward movement of the instruments into the real root canal. Two displacements speeds of the simulated root canal were used, so that the instruments in Group I were submitted to the slower speed (146 displacements per minute – d/min) and in Group 2 to the faster speed (189d/min). The time elapsed until failure of the instruments was chronometrically measured and registered; then, the number of rotations was calculated from this measurement. The comparison between the mean numbers of cycles until failure was done by the T-Student test. The results of this study showed statistically significant differences in the mean number of cycles until failure only for the F3 instrument (p=0.025). In Group I it was found about 201 fewer cycles... (Complete abstract click electronic access below)
|
3 |
"Influência do grau de proficiência técnica dos operadores no preparo de canais curvos, quando do emprego de instrumentos rotatórios de níquel-titânio" / Influence of the operators proficiency in the preparation of curved canals, using of rotary nickel-titanium instrumentsGuimarães, José Lauriére Horta 26 April 2006 (has links)
O presente estudo avaliou a interferência de operadores com diferentes proficiências no preparo de canais radiculares curvos, simulados em blocos de resina transparente. Os grupos, com 10 indivíduos cada um, foram: Grupo 1 professores de Endodontia; Grupo 2 - alunos de especialização; Grupo 3 alunos de odontologia Monitores de Endodontia e o Grupo 4 alunos de graduação no início do curso de Endodontia. Cada operador instrumentou dois canais com 20 graus de curvatura, o primeiro canal era visualizado para treinamento e o segundo não. O sistema mecanizado com instrumentos rotatórios de níquel-titânio empregado foi o RaCe®. Os parâmetros de avaliação foram: tempo de instrumentação, quantidade de material removido, desvio apical e deformação dos instrumentos. Os resultados encontrados (ANOVA e Teste de Tuckey a= 0,05%), foram: Para o tempo de instrumentação, no primeiro canal, houve diferença estatística entre o grupo 1 e os grupos 3 e 4, o grupo 2 diferiu somente do grupo 4. Já, no segundo canal, não houve diferença estatística entre os grupos. Para a quantidade de material removido do primeiro canal houve diferença estatística entre os graduados (grupos 1 e 2) em relação aos graduandos (grupos 3 e 4), porém, no segundo canal, houve diferença somente entre os grupos 1 e 2. O desvio apical não apresentou diferença estatística entre os grupos em nenhuma das condições experimentais. Após a aplicação do teste do Qui-quadrado (a=0,01%), observou-se que o grupo 1 foi o que produziu as menores deformações nos instrumentos. Conclui-se que: Os desvios apicais promovidos foram semelhantes entre os grupos experimentais. Houve diminuição no tempo de instrumentação do segundo canal em relação ao primeiro, com diferença estatística nos grupos dos monitores e acadêmicos e que não houve diferença estatística entre os grupos, em relação ao tempo de instrumentação do segundo canal. Os grupos dos graduados (professores e alunos de especialização) excisaram maior quantidade de material do primeiro canal, quando comparados aos dos graduandos (monitores e acadêmicos), não havendo diferença estatística entre os grupos em relação à quantidade de material removido do segundo canal, excetuando a comparação entre os professores e os alunos de especialização, onde os primeiros desgastaram significativamente mais que os últimos. Comparados aos demais grupos, os professores produziram menores deformações aos instrumentos. / This study evaluated the interference of operators with different proficiencies in the preparation of curved canals , simulated transparent resin blocks. The groups, with 10 individuals each, were: Group 1 - professors of Endodontics; Group 2 students of specialization; Group 3 undergraduate dental students who had concluded the Endodontics course and Group 4 - undergraduate dental students in the beginning of the Endodontics course. Each operator prepared two canals with 20 degrees of bending, the first canal was visualized for training and second no. The rotary instrumentation used was the RaCe®. The parameters of evaluation were: time of instrumentation, amount of removed material, apical transportation and deformation of the instruments. The results (ANOVA and Test of Tuckey = 0.05%): In relation to the instrumentation time, when of the execution of the first canal, it had statistics difference between group 1 and groups 3 and 4, group 2 only differed from group 4. When of the execution of the second canal it did not have difference statistics between the groups. For the amount of material removed of the first canal it had difference statistics between the graduated (groups 1 and 2) relation to the undegraduated (groups 3 and 4). After the second canal instrumentation, only had difference between groups 1 and 2. The apical transportation did not present statistics difference enters the groups in no ne of the experimental conditions. After the application ?2 test (a=0,01%), was observed that group 1 produced lesser deformations in the instruments. Conclusions: The apical transportation was similar between the different groups. It had reduction in the time of instrumentation of the second canal in relation to the first one, with statistics difference in the groups of the monitors and academics. It did not have difference statistics between the groups, in relation to the time of instrumentation of the second canal. The groups of the graduated ones (professors and students of specialization) removed bigger amount of material of the first canal, when compared with the ones of the undergraduate (monitorial and academic). It did not have statistics difference enters the groups in relation to the amount of material removed of the second canal, excepting the comparison between the professors and the students of specialization, where the first ones had consumed significantly more than the last ones. Compared with all groups, the professors had produced minors deformations to the instruments.
|
4 |
Estudo sobre o transporte apical e capacidade de limpeza de sistema de instrumento único associado a diferentes técnicas de cateterismoCarvalho, Guilherme Moreira de 20 April 2015 (has links)
Submitted by Geyciane Santos (geyciane_thamires@hotmail.com) on 2015-06-11T15:00:04Z
No. of bitstreams: 1
Dissertação - Guilherme Moreira de Carvalho.pdf: 2393725 bytes, checksum: fd0d33f11129e6d87707bc6fcbae3763 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-11T20:37:45Z (GMT) No. of bitstreams: 1
Dissertação - Guilherme Moreira de Carvalho.pdf: 2393725 bytes, checksum: fd0d33f11129e6d87707bc6fcbae3763 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-11T20:38:59Z (GMT) No. of bitstreams: 1
Dissertação - Guilherme Moreira de Carvalho.pdf: 2393725 bytes, checksum: fd0d33f11129e6d87707bc6fcbae3763 (MD5) / Made available in DSpace on 2015-06-11T20:38:59Z (GMT). No. of bitstreams: 1
Dissertação - Guilherme Moreira de Carvalho.pdf: 2393725 bytes, checksum: fd0d33f11129e6d87707bc6fcbae3763 (MD5)
Previous issue date: 2015-04-20 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The purpose of this study was to evaluate apical transportation using CT Scans, and, using histological analysis, to evaluate the cleaning effectiveness of different glide path techniques associated with the use of Reciproc system`s R25 instrument. To perform the experiment, 52 mandibular molars were selected, with mesial root canal curvature between 20° and 40° and canal curvature radius less than or equal to 10 mm. Size 10 K-type instruments were used to determine the presence of independent foramen. In order to standardize tooth size, the crowns were partially sectioned at 16 mm and then measured 3 mm in the mesial root, which were transferred to the distal root, to be sectioned at that point. The selected teeth were divided into four groups of 13: Group 1: glide path with manual file, sizes 10 and 15 and instrumentation with the R25; Group 2: Reciproc R25 without a glide path; Group 3: the glide path performed with PathFile and instrumentation with the Reciproc R25 and Group 4: control group, no instrumentation. The distal root was then embedded in resin blocks for the scans to be standardized in the same position, before and after instrumentation, and to be fixed in a vise, in order to standardize instrumentation position. The working length of the mesial canals was set at 0.5 mm from the apex. After performing the glide path, the root canals were prepared following manufacturer recommendations. Sodium hypochlorite 2.5% was the irrigating solution used. After instrumentation, teeth again underwent CT scanning, after which the apical third of each specimen was subjected to routine histotechnical processing in order to obtain 12 sections 5 μm thick. Apical deviation was assessed by applying formulas to values obtained before and after instrumentation and histological analysis was performed by evaluating the histological sections with a 230x magnification and the quantification of debris through the superposition of a grid. Data were subjected to the Kruskal-Wallis Test and the Dunn Multiple Comparisons Test. The results of the apical deviation presented no significant difference between the experimental groups (p > 0,05). As for cleaning ability, the difference between groups 1 and 2 was found to be statistically significant (p ˂ 0,01). The methodology and the results lead to the conclusion that the glide path technique used did not produce a statistically significant difference in apical deviation. However, the Reciproc system instrumentation technique, without a glide path, showed greater capacity for cleaning the root canal system. / O objetivo do presente estudo foi avaliar o trasnporte apical e a capacidade de limpeza promovida por diferentes técnicas de cateterismo associadas ao uso de um sistema de instrumento único. Foram selecionados 52 molares inferiores com grau de curvatura da raiz mesial entre 20° e 40° e raio de curvatura menor ou igual a10 mm. Com o auxílio de instrumentos tipo K #10, avaliou-se a presença de forames independentes. Com o objetido de padronizar o tamanho dos dentes, as coroas foram parcialmente seccionadas em 16 mm e mediu-se 3 milímetros na raiz mesial, que foram transpostos para a raiz distal, e esta foi seccionada naquele ponto. Os dentes selecionados foram separados aleatoriamente (n=13) dentes cada, Grupo 1, cateterismo inicial com lima manual tamanhos 10 e 15 e instrumentação com R25; Grupo 2, Reciproc R25 sem cateterismo; Grupo 3, cateterismo com PathFile e preparo com Reciproc R25 e Grupo 4, controle, que não foi instrumentado. Em seguida, a raiz distal foi inserida em blocos de resina, para padronização das tomografias na mesma posição antes e após a instrumentação e para ser afixado em uma morsa de bancada, a fim de se padronizar a posição de instrumentação. O comprimento de trabalho dos canais mesiais foi definido a 0,5 mm aquém ao ápice. Após o cateterismo, os canais foram instrumentados seguindo as recomendações do fabricante. Hipoclorito de sódio a 2,5% foi a solução irrigadora utilizada. Após a instrumentação, os dentes foram submetidos novamente a tomografia e em seguida o terço apical de cada espécime foi submetido ao processamento histotécnico de rotina para obtenção de 12 cortes com 5 μm de espessura. A análise do desvio apical se deu pela aplicação de fórmulas aos valores obtidos antes e após a instrumentação e a análise histológica se deu pela avaliação dos cortes histológicos e determinação do percentual de debris presente nos canais por meio da sobreposição de uma grade de integração. Os dados obtidos foram submetidos a testes de Kruskall-Wallis e teste de Múltiplas Comparações de Dunn. Os resultados do desvio apical não mostraram diferenças significantes entre os grupos avaliados (p > 0,05). Em relação a capacidade de limpeza, houve diferença significativa entre o grupo 1 e o grupo 2 (p ˂ 0,01). Com base na metodologia empregada e nos resultados obtidos, concluiu-se que não houve diferença significante em relação ao desvio apical entre as diferentes técnicas de cateterismo, o sistema Reciproc, sem cateterismo prévio, apresentou maior capacidade de limpeza do sistema de canais radiculares.
|
5 |
Emprego da microtomografia computadorizada na análise de preparo, limpeza e obturação de canais radiculares ovalados /Espir, Camila Galletti. January 2018 (has links)
Orientador: Mário Tanomaru Filho / Resumo: Este estudo avaliou morfologia, preparo e obturação com diferentes técnicas e materiais em canais radiculares ovais. Quinhentos e vinte incisivos inferiores foram avaliados por meio de radiografias digitais nos sentidos vestíbulo lingual (VL) e mesio distal (MD), sendo obtidos a partir da relação de diâmetro VL/MD: 23.3% canais achatados; 41.3% ovais; 27.3% arredondados; 4.5% redondos e 3.6% com achatamento VL (Publicação 1). Os incisivos classificados como ovais foram preparados: Reciproc 40 (R40) reciprocante anti-horário; MTwo 40, taper .06 (M 40.06) reciprocante horário (150° horário e 30° anti-horário); e MTwo 20, taper .06 seguido de MTwo 40, taper .06 (M 20/40.06) em reciprocante horário (Publicação 2); R40, Unicone 20.06 seguido de 40.06 reciprocante (Uni20/40.06) e sistema Mtwo até 40.06 rotatório (Mtwo seq) (Publicação 3); e R40, M40.06 e Mtwo seq (Publicação 4). A obturação foi realizada pelas técnicas de cone único (CU) ou condensação lateral (CL) e cimento AH Plus (AHP) (Publicação 4); CU e AHP ou Neo MTA Plus (NMTAP) (Publicação 5); e CL e MTA Fillapex (MTAF) ou AHP (Publicação 6). Escaneamentos foram realizados antes e após cada etapa experimental, utilizando o microtomófrafo SkyScan 1176. Volume, porcentagem de debris, de superfície não instrumentada e de falhas na obturação foram obtidos. Dados foram submetidos aos testes estatísticos ANOVA e Tukey, Kruskal-Wallis e Dunn, T Pareado ou Mann-Whitney (α=0.05). Reciproc e MTwo usando diferentes cinemáticas aprese... (Complete abstract click electronic access below) / Abstract: This study evaluated the morphology, preparation and filling using different techniques and materials in oval-shaped canals. Five hundred and twenty mandibular incisors were evaluated using digital radiography in the buccolingual (BL) and mesio distal (MD) directions, being obtained from the VL / MD diameter ratio: 23.3% flattened canals; 41.3% ovals; 27.3% rounded; 4.5% round e 3.6% with flattening BL (Publication 1). The oval-shaped incisors were prepared: Reciproc 40 (R40) counterclockwise reciprocating; MTwo 40, taper .06 (M 40.06) clockwise reciprocating (150° clockwise and 30° counterclockwise); and MTwo 20, taper .06 and MTwo 40, taper .06 (M 20/40.06) clockwise reciprocating (Publication 2); R40, Unicone 20.06 and 40.06 reciprocanting (Uni20/40.06) and Mtwo rotary system until 40.06 (Mtwo seq) (Publication 3); and R40, M40.06 e Mtwo seq (Publication 4). Filling was performed using single-cone technique (SC) or lateral condensation (LC) and AH Plus sealer (AHP) (Publication 4); SC and AHP or Neo MTA Plus (NMTAP) sealer (Publication 5); and LC using MTA Fillapex (MTAF) or AHP sealer (Publication 6). Scans were performed before and after each experimental stage, using the SkyScan 1176 micro-computed tomography. Volume, percentage of debris, percentage of uninstrumented surface and voids in obturation were obtained. Data were submetted to ANOVA and Tukey's tests or Kruskal-Wallis and Dunn tests, non-paired T test or Mann-Whitney (α=0.05). Reciproc and Mtwo using different... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
|
6 |
ANÁLISE COMPARATIVA DOS SISTEMAS DE INSTRUMENTO ÚNICO RECIPROC, WAVEONE E ONE SHAPE NA INCIDÊNCIA DE DEFEITOS DENTINÁRIOS / COMPARATIVE ANALYSIS OF RECIPROC, WAVEONE AND ONE SHAPE SINGLE-FILE SYSTEMS ON THE INCIDENCE OF DENTINAL DEFECTSPillar, Rafael 02 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Dentinal defects are characterized by cracks in the root dentin that can develop into a vertical root fractures (VRF), thus leading to tooth loss. Endodontic procedures may generate these defects and between these steps, the biomechanical preparations with NiTi rotary instruments are associated with the incidence of these amendments dentinal. A new concept in minimally invasive preparation was introduced, along with a new reciprocating movement, using a single instrument for root canal instrumentation. This allows less root dentin is removed, thus avoiding the weakening of tooth structure. The aim of this study was evaluate the incidence of dentinal defects after root canal preparation by three single-file systems. One hundred forty mesial roots of mandibular molars were selected and randomly assigned to 4 groups (n= 35 mesial roots per group). One group was left unprepared as control. In two groups, the root canals were instrumented by using the reciprocating single-file systems WaveOne (Dentsply-Maillefer) and Reciproc (VDW), while other group was prepared with single-file of continuous rotation One Shape (Micro-Mega). The specimens were sectioned in 03, 06 and 09 mm from the apex with a low-speed saw under water cooling (IsoMet 1000 Precision Saw) and observed through a stereomicroscope (Zeiss Stemi SV6, Carl Zeiss) at a magnification of 20×. The pictures were recorded and evaluated by two blinded calibrated observers. The slices were categorized in: 0- No defects; 1- Others defects and 2 vertical root fracture. The dates were statistically analyzed with a significance level set at α = 0.05. The chi-square and Fisher exact tests were used to assess the differences between groups. No defects were observed in control group. All the experimental groups showed dentinal defects. The reciprocating files were associated with more defects than the continuous rotary file and control group (P < 0.05), but no significant difference between them (P = .115). VRF was observed only in the One Shape group. The results of this study suggest that the biomechanical preparation could cause damage in the root dentin and that the continuous rotary has a tendency to result in fewer defects compared to reciprocating files. / Defeitos dentinários são caracterizados por trincas na dentina radicular que podem evoluir para uma Fratura Vertical da Raiz (FVR), levando assim a perda do elemento dentário. O preparo biomecânico com o uso de sistemas rotatórios está associado com a incidência dessas alterações dentinárias. Atualmente, o uso de um único instrumento para a instrumentação dos canais radiculares juntamente com uma cinemática reciprocante tem sido introduzido. Desse modo, o objetivo desse estudo foi avaliar a incidência de defeitos dentinários causado por três sistemas de instrumento único. Cento e quarenta raízes mesiais de molares inferiores foram selecionadas e aleatoriamente divididas em quatro grupos (n= 35 por grupo). Um grupo não sofreu intervenção e serviu como controle. As demais raízes foram preparadas pelos instrumentos reciprocantes WaveOne (Dentsply-Maillefer) e Reciproc (VDW) e por um instrumento de rotação contínua One Shape (Micro-Mega). As raízes foram seccionadas horizontalmente com auxílio de uma máquina de corte de precisão (IsoMet 1000 Precision Saw) em 03, 06 e 09 mm a partir do ápice e observadas em um estereomicroscópio (Zeiss Stemi SV6, Carl Zeiss) sob um aumento de 20×. Imagens das fatias foram gravadas e avaliadas por dois observadores cegos, previamente calibrados. As fatias foram categorizadas em: 0 - Ausência de defeitos; 1- Outros defeitos; 2- Fratura Vertical da Raiz. Os resultados obtidos foram submetidos à análise estatística com nível de significância fixado em α= 0.05. Os testes Qui-quadrado e Exato de Fisher foram utilizados para analisar e comparar as diferenças entre os grupos. O grupo controle não apresentou defeito. Todos os grupos experimentais apresentaram defeitos dentinários e foram diferentes estatisticamente do grupo controle (P < 0.05). Os grupos reciprocantes foram associados à presença de mais defeitos do que o grupo One Shape, mas não houve diferença significante entre eles (P = .115). O grupo One Shape foi o único que apresentou FVR. Os resultados obtidos nesse estudo sugerem que o preparo biomecânico com instrumentos rotatórios e/ou de reciprocidade podem causar danos na dentina radicular.
|
7 |
"Influência do grau de proficiência técnica dos operadores no preparo de canais curvos, quando do emprego de instrumentos rotatórios de níquel-titânio" / Influence of the operators proficiency in the preparation of curved canals, using of rotary nickel-titanium instrumentsJosé Lauriére Horta Guimarães 26 April 2006 (has links)
O presente estudo avaliou a interferência de operadores com diferentes proficiências no preparo de canais radiculares curvos, simulados em blocos de resina transparente. Os grupos, com 10 indivíduos cada um, foram: Grupo 1 professores de Endodontia; Grupo 2 - alunos de especialização; Grupo 3 alunos de odontologia Monitores de Endodontia e o Grupo 4 alunos de graduação no início do curso de Endodontia. Cada operador instrumentou dois canais com 20 graus de curvatura, o primeiro canal era visualizado para treinamento e o segundo não. O sistema mecanizado com instrumentos rotatórios de níquel-titânio empregado foi o RaCe®. Os parâmetros de avaliação foram: tempo de instrumentação, quantidade de material removido, desvio apical e deformação dos instrumentos. Os resultados encontrados (ANOVA e Teste de Tuckey a= 0,05%), foram: Para o tempo de instrumentação, no primeiro canal, houve diferença estatística entre o grupo 1 e os grupos 3 e 4, o grupo 2 diferiu somente do grupo 4. Já, no segundo canal, não houve diferença estatística entre os grupos. Para a quantidade de material removido do primeiro canal houve diferença estatística entre os graduados (grupos 1 e 2) em relação aos graduandos (grupos 3 e 4), porém, no segundo canal, houve diferença somente entre os grupos 1 e 2. O desvio apical não apresentou diferença estatística entre os grupos em nenhuma das condições experimentais. Após a aplicação do teste do Qui-quadrado (a=0,01%), observou-se que o grupo 1 foi o que produziu as menores deformações nos instrumentos. Conclui-se que: Os desvios apicais promovidos foram semelhantes entre os grupos experimentais. Houve diminuição no tempo de instrumentação do segundo canal em relação ao primeiro, com diferença estatística nos grupos dos monitores e acadêmicos e que não houve diferença estatística entre os grupos, em relação ao tempo de instrumentação do segundo canal. Os grupos dos graduados (professores e alunos de especialização) excisaram maior quantidade de material do primeiro canal, quando comparados aos dos graduandos (monitores e acadêmicos), não havendo diferença estatística entre os grupos em relação à quantidade de material removido do segundo canal, excetuando a comparação entre os professores e os alunos de especialização, onde os primeiros desgastaram significativamente mais que os últimos. Comparados aos demais grupos, os professores produziram menores deformações aos instrumentos. / This study evaluated the interference of operators with different proficiencies in the preparation of curved canals , simulated transparent resin blocks. The groups, with 10 individuals each, were: Group 1 - professors of Endodontics; Group 2 students of specialization; Group 3 undergraduate dental students who had concluded the Endodontics course and Group 4 - undergraduate dental students in the beginning of the Endodontics course. Each operator prepared two canals with 20 degrees of bending, the first canal was visualized for training and second no. The rotary instrumentation used was the RaCe®. The parameters of evaluation were: time of instrumentation, amount of removed material, apical transportation and deformation of the instruments. The results (ANOVA and Test of Tuckey = 0.05%): In relation to the instrumentation time, when of the execution of the first canal, it had statistics difference between group 1 and groups 3 and 4, group 2 only differed from group 4. When of the execution of the second canal it did not have difference statistics between the groups. For the amount of material removed of the first canal it had difference statistics between the graduated (groups 1 and 2) relation to the undegraduated (groups 3 and 4). After the second canal instrumentation, only had difference between groups 1 and 2. The apical transportation did not present statistics difference enters the groups in no ne of the experimental conditions. After the application ?2 test (a=0,01%), was observed that group 1 produced lesser deformations in the instruments. Conclusions: The apical transportation was similar between the different groups. It had reduction in the time of instrumentation of the second canal in relation to the first one, with statistics difference in the groups of the monitors and academics. It did not have difference statistics between the groups, in relation to the time of instrumentation of the second canal. The groups of the graduated ones (professors and students of specialization) removed bigger amount of material of the first canal, when compared with the ones of the undergraduate (monitorial and academic). It did not have statistics difference enters the groups in relation to the amount of material removed of the second canal, excepting the comparison between the professors and the students of specialization, where the first ones had consumed significantly more than the last ones. Compared with all groups, the professors had produced minors deformations to the instruments.
|
8 |
Avaliação do selamento e transporte apical em dentes humanos com canais preparados com o sistema rotatório MTWO® com e sem ampliação foraminal = estudo in-vitro / Evaluation of apical sealing and transportation in human teeth prepared by MTWO® rotatory system with and without foraminal enlargement : in vitro studyWinocur, Estela Marta Doffo de, 1964- 02 July 2012 (has links)
Orientador: Adriana de Jesus Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:30:40Z (GMT). No. of bitstreams: 1
Winocur_EstelaMartaDoffode_D.pdf: 39787975 bytes, checksum: dfb0acb3bf358d565765b0c840c32986 (MD5)
Previous issue date: 2012 / Resumo: O objetivo deste estudo in vitro foi avaliar o selamento apical após obturação endodôntica, em dentes humanos preparados com e sem ampliação do forame apical, com o Sistema Rotatório Mtwo® (VDW, Munique, Alemanha). Vinte prémolares inferiores foram divididos em dois grupos. No Grupo I, os canais radiculares foram preparados 1mm além do forame apical e, no Grupo II, 1 mm aquém do CRC. Os dentes foram preparados para avaliação no MEV (JEOL, Modelo JSM 5600LV, Tókio, Japão) e as imagens do forame apical obtidas em aumento de 75x, em posições padronizadas, permitindo a mensuração da área foraminal antes, após o preparo e após a obturação. Por meio do processo do Sistema de Subtração de Imagens (Emago® Sistema de Diagnóstico Oral, Louwesweg, Amsterdam, Holanda), foi possível identificar as variações de forma e transporte do forame apical assim como o nível de preenchimento de sua circunferência pelo cimento obturador Pulp Canal Sealer (Sybron Endo, USA) após o preparo. Os resultados encontrados, submetidos à análise estatística, permitiram concluir que os dentes do Grupo I apresentaram maior diâmetro foraminal que os do Grupo II (Teste Anova, p<0,05) e que houve diferença estatisticamente significante quanto ao transporte do forame (Teste Exato de Fisher, p=0,0108); quanto ao selamento apical houve diferença estatisticamente significante entre os grupos I e II (Testes t de Student e Exato de Fisher, p=0,0007) sendo que, no Grupo I, ocorreram selamento em 100% dos espécimes analisados / Abstract: The aim of this in vitro study was to evaluate the apical root sealing after endodontic filling, in human teeth that were prepared with and without apical foramen enlargement by Mtwo® Rotary System (VDW, Munich, Germany). Twenty mandibular premolars were divided in two groups. Group I had root canals prepared 1mm beyond apical foramen, and in Group II, 1mm below RCL. Teeth were prepared for an electronic microscopy analysis (JEOL, Model JSM 5600LV, Tokyo, Japan). Apical foramen images were 75 times magnified, at standardized positions, allowing measurements from apical foramen area before and after root canal preparation, and after root filling. By using the Image Subtraction System (Emago®, Oral Diagnostic System, Louwesweg, Amsterdam, Netherlands) apical foramen shape modifications and transportation as well as the level of its circumferential filling by Pulp Canal Sealer cement (Sybron Endo, USA) after root canal preparation were accessed. After statistical analysis, results allowed to conclude that Group I teeth showed larger foraminal diameter than Group II (Anova Test, p<0,05) and that foramen transportation difference was statistically significant (Fisher Exact Test, p=0,0108); apical foramen sealing also differed statistically between groups I and II (Student t Test and Fisher Exact Test, p=0,0007) and that 100% of Group I specimens showed apical root sealing / Doutorado / Endodontia / Doutor em Clínica Odontológica
|
9 |
Avaliação da capacidade de corte e resistência à fadiga cíclica dos instrumentos Profile Vortex e ProTaper / Evaluation of cutting ability and cyclic fatigue resistance of instruments Profile Vortex and ProTaperGraziela Salum 03 August 2012 (has links)
Objetivo: Analisar in vitro a capacidade de corte e a resistência à fadiga cíclica dos sistemas rotatórios ProFile Vortex (Dentsply Tulsa Dental, USA) e ProTaper (Dentsply Maillefer, Suíça). Metodologia: Para a análise da capacidade de corte, pesou-se em balança analítica digital cem blocos de resina fenólica que continham canais simulados com 75 de curvatura, obtendo-se os pesos iniciais (P0) e após a instrumentação dos canais, estes blocos foram novamente pesados obtendo-se os pesos finais (P1). Dividiram-se quarenta instrumentos em dois grupos. Grupo A: vinte instrumentos ProFile Vortex n25; 25mm; taper.06 e Grupo B: vinte instrumentos ProTaper F1; 25mm. Subdividiu-se em dois subgrupos com dez amostras cada, de acordo com o número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso e grupos A5 e B5, instrumentos de cinco usos. Avaliou-se a resistência à fadiga cíclica submetendo-se todos os instrumentos a ensaio dinâmico, utilizando-se dispositivo desenvolvido para tal, até a ocorrência da fratura que foi constatada visualmente. O número de ciclos até a fratura assim como o tempo expresso em segundos foram registrados e realizou-se estatística descritiva, o teste `t de Student e o teste de Mann-Whitney. Resultados: Em todos os blocos houve perda de peso, porém sem significado estatístico (Pvalor>0,05). Os instrumentos Profile Vortex removeram mais material e completaram maior número de ciclos até a fratura, com significância estatística (Pvalor>0,05) quando comparados com os instrumentos Protaper. Conclusão: A capacidade de corte em função do número de uso e a resistência à fadiga cíclica, nos parâmetros utilizados neste estudo, foram maiores para os instrumentos Profile Vortex quando comparados com os instrumentos Protaper. / Aim: The aim of this study was to evaluate in vitro the ability to cut and cyclic fatigue resistance of rotary systems ProFile Vortex (Dentsply Tulsa Dental, USA) and ProTaper (Dentsply Maillefer, Switzerland). Methods: To analyze the ability to cut weight in analytical scale digital block one hundred made of phenolic resin containing simulated channels 75 curvature obtaining to the initial weights (P0) and following the instrumentation of canals, these blocks were weighed again obtaining is the end weight (P1). Instruments forty were divided into two groups. Group A: twenty ProFile Vortex instruments n25, 25mm; taper.06 and Group B: twenty ProTaper instruments F1, 25mm. Subdivided into two subgroups with ten samples each, according to the number of uses, is established as follows: A0, B0 groups, without using tools and groups A5 and B5, five uses instruments. To evaluate the fatigue resistance cyclic submitting all the dynamic test instruments using device developed for this purpose, until the occurrence of fracture was observed visually. O number of cycles fracture to and the time in seconds were recorded and analysis descriptive, the `t Student test and Mann-Whitney. Results: In every block there was weight loss, however no statistical significance (Pvalor> 0.05). The Vortex Profile instruments removed more material and completed a greater number of cycles to fracture, with statistical significance when compared with the instruments Protaper (Pvalor> 0.05). Conclusions: The cutting ability the number of use and cyclic fatigue resistance, the parameters used in this study were higher for the Vortex Profile instruments when compared with Protaper instruments.
|
10 |
Avaliação do preparo de canais radiculares com secção transversal oval longa realizado pelos sistemas Reciproc e Biorace utilizando a microtomografia computadorizada / Evaluation of the preparation of long oval root canals with Reciproc and Biorace systems using micro-computed tomographyBusquim, Sandra Soares Kühne 24 September 2013 (has links)
Os instrumentos endodônticos de níquel-titânio (NiTi) influenciaram positivamente o preparo dos canais radiculares. Entretanto, algumas dificuldades inerentes à própria anatomia do sistema endodôntico, permanecem. Canais radiculares com secção transversal oval longa dificultam a ação dos instrumentos rotatórios, os quais não conseguem se adaptar às suas paredes em toda extensão. O sistema Reciproc de lima única (VDW, Munique, Alemanha), recentemente lançado, foi desenvolvido para o preparo do canal radicular pela técnica de movimento de trabalho recíproco. Este movimento alivia o estresse do instrumento, reduzindo o risco de fatiga cíclica causada pela tensão e compressão. Com a finalidade de comparar o efeito deste movimento no preparo do canal, foi utilizado o sistema Biorace (FKG Dentaire, LA Chaux-de Fonds, Suíça) por ser um sistema de instrumentação rotatória completa, onde o instrumento final tem diâmetro compatível com o instrumento Reciproc R40 utilizado. O objetivo deste estudo foi avaliar, ex vivo, o preparo de canais ovais longos de molares inferiores com o sistema Reciproc comparando-o ao preparo com instrumentos do sistema Biorace, por meio da microtomografia computadorizada (CT). Raízes distais de trinta molares inferiores foram utilizadas e divididas aleatoriamente em dois grupos: G1 Reciproc R40 e G2 Biorace. Os dentes foram escaneados por um microtomógrafo de raios-X SkyScan 1172 antes e após o preparo dos canais radiculares. As imagens obtidas foram importadas e reconstruídas, fornecendo secções transversais da estrutura interna das amostras. Em seguida, com o auxílio dos softwares CTan, CTVol, MeshLab e MatLab foram possíveis a análise tridimensional e a visualização do canal radicular antes e após o procedimento do preparo químico-cirúrgico, para comparação das mudanças no volume e superfícies não preparadas da parede do canal. Os resultados foram submetidos ao teste estatístico não paramétrico de Mann-Whitney para análise do aumento do volume e das superfícies não preparadas. O teste não paramétrico de Kruskal-Wallis foi o de escolha para análise intra-grupo, ou seja, do mesmo sistema nos diferentes terços do canal. O preparo do canal radicular com o sistema Reciproc resultou em maior aumento do volume no canal como um todo e no seu terço apical (p < 0,5). Quanto à comparação das superfícies não preparadas da parede do canal, o sistema Reciproc mostrou-se superior ao sistema Biorace no terço apical (p < 0,0001). O sistema Biorace apresentou os melhores resultados, estatisticamente significantes, nos terços cervical e médio (p < 0,0001). Na avaliação das superfícies não preparadas no mesmo sistema, o sistema Reciproc mostrou melhores resultados no terço apical, em relação aos terços cervical e médio (p < 0,05), assim como o sistema Biorace. Concluiu-se que nenhum sistema conseguiu preparar completamente o canal oval longo. O sistema Reciproc determinou maior desgaste de dentina no canal como um todo e no terço apical. Em relação às superfícies não preparadas do canal, o sistema Reciproc melhor preparou o terço apical, enquanto que o sistema Biorace melhor preparou os terços cervical e médio (áreas mais ovaladas). Na comparação no mesmo sistema, Reciproc e Biorace mostraram melhores resultados, deixando menos superfícies não preparadas, no terço apical do canal. / The endodontic instruments of nickel-titanium (NiTi) positively influenced the preparation of root canals. However, some difficulties inherent to the anatomy of the endodontic system, remain. Root canals with long oval cross-section hinder the action of rotating instruments, which cant adapt to the root canal walls in all its extension. The single-file Reciproc system (VDW, Munich, Germany), recently launched, was developed to prepare the root canal in reciprocating movement. This movement relieves the stress of the instrument, thus reducing the risk of cyclic fatigue caused by tension and compression. With the purpose of comparing the effect of this movement on root canal preparation, the Biorace system (FKG Dentaire, La Chaux-de-Fonds, Switzerland) was used. This full rotary sequence system has a final instrument diameter compatible with the instrument Reciproc R40 used. The aim of this study was to evaluate, ex vivo, the preparation of long oval canals of mandibular molars with the Reciproc system comparing it to the Biorace system using micro-computed tomography (CT). Distal canals of thirty mandibular molars were used and randomly divided into two groups: G1 - Reciproc R40 and G2 - Biorace. Teeth were scanned by a micro-computed tomography SkyScan 1172 before and after the preparation of the root canals. The images obtained were imported and rebuilt, providing cross-sections of the internal structure of the samples. Then, with the aid of softwares CTan, CTVol, MeshLab and MatLab, threedimensional analysis and visualization of root canal before and after the biomechanical preparation were performed. Morphometric variations were measured by volume increases and remaining untreated canal surface area. The results were subjected to a non-parametric Mann-Whitney test for volume and untreated surface analysis and to a Kruskal-Wallis test for intra-group analysis, i.e., the same system in all different thirds of the canal. The root canal preparation with the Reciproc system resulted in greater volume increase of the whole root canal and its apical third (p < 0,5). Regarding untreated canal surface area, the Reciproc system was superior to the Biorace system in the apical third (p < 0,0001). The Biorace system presented the best results, statistically significant, in the cervical and middle thirds of the root canal (p < 0,0001). In the evaluation of untreated canal surface area in the same system, the Reciproc system showed better results in the apical third, in relation to the cervical and middle thirds (p < 0,05), as well as the Biorace system. In conclusion, regardless of the instrumentation technique used, the long oval canal couldnt be completely prepared. The Reciproc system not only removed more dentin layer in the whole canal and its apical third, but also left less untreated canal surface area in the apical third (oval shaped section). The Biorace system left less untreated canal surface area in the cervical and middle thirds. In comparison on the same system, Reciproc and Biorace showed better results, leaving less untreated surface in the apical third of the root canal.
|
Page generated in 0.0911 seconds