• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Otimização da desidratação osmótica do jenipapo (Genipa americana L.)

ANDRADE, Samara Alvachian Cardoso January 2005 (has links)
Made available in DSpace on 2014-06-12T23:03:18Z (GMT). No. of bitstreams: 2 arquivo8749_1.pdf: 998118 bytes, checksum: b9e011e36f81d2cb655f3fcddbf3e526 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Problemas detectados na desidratação osmótica do jenipapo (Genipa americana L.) relativos à incorporação de sólidos, motivaram a presente pesquisa com o objetivo de otimizar o processo. Na sua implementação foram realizados estudos cinéticos por meio de planejamento fatorial 22, para determinar a influência das variáveis independentes: concentração do agente osmótico e tempo de imersão sobre os coeficientes de difusão da água e da sacarose. Na seqüência, com o objetivo de diminuir a incorporação de sólidos foi aplicado um planejamento fatorial 23, para avaliar a influência das variáveis independentes: temperatura, tipo de cobertura e geometria sobre a perda de umidade, ganho de sólidos, variação de peso e DEI (Dehydration Efficiency Index). A partir dos resultados destas etapas procedeu-se a otimização do processo por meio da metodologia de superfície de resposta utilizando o planejamento 22, para determinar a melhor temperatura e concentração da solução osmótica. Os resultados demonstraram: a influência da concentração da solução osmótica sobre o coeficiente de difusão da sacarose; que o emprego de geometria de quarto e de revestimentos comestíveis resultou em significativa redução do ganho de solutos e satisfatória perda de umidade, independentemente da temperatura que não apresentou efeito significativo (p<0,05) sobre as respostas, diferindo da concentração do agente osmótico que influenciou sobre todas elas com exceção do ganho de sólidos. As melhores condições, utilizando o DEI como parâmetro, foi a 50°C e 57°Brix
2

Campo magnético pulsado na preservação de carne bovina moída / Pulsed magnetic field in ground beef preservation

Lins, Patricia Goldschmidt 26 July 2011 (has links)
O presente estudo teve como objetivo avaliar a utilização de campo magnético pulsado (CMP) de baixa intensidade na preservação da qualidade microbiológica, cor e estabilidade oxidativa de carne bovina moída durante armazenamento aeróbio refrigerado. Amostras moídas de peixinho bovino (músculo Supraspinatus) foram expostas a CMP por 2 horas às frequências de 1, 30 ou 60 Hz ou, em outra etapa, expostas a CMP de 1 Hz de frequência por 2 horas ou continuamente por 12 dias. Amostras controle não foram expostas ao CMP. As amostras foram armazenadas a 4ºC por até 12 dias, e avaliadas a cada seis dias por meio de análise microbiológica de contagem total de bactérias mesófilas aeróbias, e a cada dois dias por meio de análises físico-químicas e bioquímicas: pH, cor instrumental (escala CIELAB), mioglobina e oxidação lipídica. A exposição ao CMP de 1 Hz por 2 horas reduziu a contagem de mesófilos aeróbios com relação ao controle em 1,3 ciclos logarítmicos no 12º dia de armazenamento refrigerado. Os conteúdos de metamioglobina das amostras expostas por 2 horas ao CMP, independente da frequência de pulso, foram significativamente menores com relação ao controle no 6º dia de armazenamento refrigerado. Os demais parâmetros de qualidade não sofreram alteração significativa com relação ao controle durante o armazenamento e não foi verificado efeito das diferentes frequências de CMP. Conclui-se que campo magnético pulsado de baixa intensidade (ordem de mili Tesla) apresenta potencial para ser utilizado como tecnologia inovadora, em combinação com a refrigeração, na preservação de carnes frescas. Todavia, mais estudos são necessários para melhor entendimento dos mecanismos de ação de campo magnético, principalmente em alimentos. / This study aimed to evaluate the use of low intensity pulsed magnetic field (PMF) in the preservation of microbiological quality, color and oxidative stability of ground beef during aerobic refrigerated storage. Ground beef samples of chuck tender (Supraspinatus muscle) were exposed to PMF for 2 hours at frequencies of 1, 30 and 60 Hz or, in another step, they were exposed to a 1 Hz PMF for 2 hours or continuously for 12 days. Control samples were not exposed to PMF. Samples were stored at 4ºC for up to 12 days, and evaluated every six days through microbiological analysis of total aerobic mesophilic bacteria count, and every two days through physicochemical and biochemical analysis of pH, instrumental color (CIELAB scale), myoglobin and lipid oxidation. Exposure to 1 Hz PMF for 2 hours reduced the growth of aerobic mesophiles in relation to the control by 1.3 logarithmic cycles in the 12th day of refrigerated storage. Metmyoglobin content of samples exposed to the PMF for 2 hours, regardless of the pulse frequency, were significantly lower compared to the control in the 6th day of refrigerated storage. The other quality parameters did not change significantly during storage compared to the control and it was not observed effect of different PMF frequencies. We concluded that low intensity pulsed magnetic field (order of mili Tesla) has the potential to be used as innovative technology, in combination with refrigeration, in fresh meat preservation. However, more studies are needed to better understand the mechanisms of action of magnetic field, mainly in foods.
3

Campo magnético pulsado na preservação de carne bovina moída / Pulsed magnetic field in ground beef preservation

Patricia Goldschmidt Lins 26 July 2011 (has links)
O presente estudo teve como objetivo avaliar a utilização de campo magnético pulsado (CMP) de baixa intensidade na preservação da qualidade microbiológica, cor e estabilidade oxidativa de carne bovina moída durante armazenamento aeróbio refrigerado. Amostras moídas de peixinho bovino (músculo Supraspinatus) foram expostas a CMP por 2 horas às frequências de 1, 30 ou 60 Hz ou, em outra etapa, expostas a CMP de 1 Hz de frequência por 2 horas ou continuamente por 12 dias. Amostras controle não foram expostas ao CMP. As amostras foram armazenadas a 4ºC por até 12 dias, e avaliadas a cada seis dias por meio de análise microbiológica de contagem total de bactérias mesófilas aeróbias, e a cada dois dias por meio de análises físico-químicas e bioquímicas: pH, cor instrumental (escala CIELAB), mioglobina e oxidação lipídica. A exposição ao CMP de 1 Hz por 2 horas reduziu a contagem de mesófilos aeróbios com relação ao controle em 1,3 ciclos logarítmicos no 12º dia de armazenamento refrigerado. Os conteúdos de metamioglobina das amostras expostas por 2 horas ao CMP, independente da frequência de pulso, foram significativamente menores com relação ao controle no 6º dia de armazenamento refrigerado. Os demais parâmetros de qualidade não sofreram alteração significativa com relação ao controle durante o armazenamento e não foi verificado efeito das diferentes frequências de CMP. Conclui-se que campo magnético pulsado de baixa intensidade (ordem de mili Tesla) apresenta potencial para ser utilizado como tecnologia inovadora, em combinação com a refrigeração, na preservação de carnes frescas. Todavia, mais estudos são necessários para melhor entendimento dos mecanismos de ação de campo magnético, principalmente em alimentos. / This study aimed to evaluate the use of low intensity pulsed magnetic field (PMF) in the preservation of microbiological quality, color and oxidative stability of ground beef during aerobic refrigerated storage. Ground beef samples of chuck tender (Supraspinatus muscle) were exposed to PMF for 2 hours at frequencies of 1, 30 and 60 Hz or, in another step, they were exposed to a 1 Hz PMF for 2 hours or continuously for 12 days. Control samples were not exposed to PMF. Samples were stored at 4ºC for up to 12 days, and evaluated every six days through microbiological analysis of total aerobic mesophilic bacteria count, and every two days through physicochemical and biochemical analysis of pH, instrumental color (CIELAB scale), myoglobin and lipid oxidation. Exposure to 1 Hz PMF for 2 hours reduced the growth of aerobic mesophiles in relation to the control by 1.3 logarithmic cycles in the 12th day of refrigerated storage. Metmyoglobin content of samples exposed to the PMF for 2 hours, regardless of the pulse frequency, were significantly lower compared to the control in the 6th day of refrigerated storage. The other quality parameters did not change significantly during storage compared to the control and it was not observed effect of different PMF frequencies. We concluded that low intensity pulsed magnetic field (order of mili Tesla) has the potential to be used as innovative technology, in combination with refrigeration, in fresh meat preservation. However, more studies are needed to better understand the mechanisms of action of magnetic field, mainly in foods.

Page generated in 0.2049 seconds