• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 14
  • 10
  • 10
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito de uma sess?o de caminhada em intensidade autosselecionada ao ar livre sobre a press?o arterial ambulatorial de idosas hipertensas fisicamente inativas: um ensaio cruzado / Effect of a single session of self-paced walking outdoor on ambulatory blood pressure in inactive hypertensive older women: a crossover trial

Costa, Ingrid Bezerra Barbosa 07 August 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-11-03T21:24:07Z No. of bitstreams: 1 IngridBezerraBarbosaCosta_DISSERT.pdf: 991748 bytes, checksum: a15a750264875b7c40365aeca4c9afc2 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-11-17T23:04:53Z (GMT) No. of bitstreams: 1 IngridBezerraBarbosaCosta_DISSERT.pdf: 991748 bytes, checksum: a15a750264875b7c40365aeca4c9afc2 (MD5) / Made available in DSpace on 2017-11-17T23:04:53Z (GMT). No. of bitstreams: 1 IngridBezerraBarbosaCosta_DISSERT.pdf: 991748 bytes, checksum: a15a750264875b7c40365aeca4c9afc2 (MD5) Previous issue date: 2017-08-07 / OBJETIVO: analisar o efeito de uma sess?o de caminhada em intensidade autosselecionada ao ar livre sobre a press?o arterial (PA) ambulatorial de idosas hipertensas fisicamente inativas. METODOLOGIA: vinte idosas hipertensas medicadas (64,9 ? 4,5 anos; 29,0 ? 4,3 kg/m?; PA de repouso 121,5 ? 11,2 / 59,5 ? 7,9 mmHg) e fisicamente inativas (< 8.000 passos/dia) completaram esse ensaio cl?nico controlado e randomizado, com delineamento cruzado. Ap?s avalia??o inicial, as idosas participaram de duas sess?es em ordem randomizada, com uma semana de intervalo entre elas: i) sess?o de caminhada em intensidade autosselecionada ao ar livre (pista de 400 m) e ii) sess?o controle (sem exerc?cio). Ambas as sess?es foram realizadas pela manh? entre 7:00-8:00 h. Durante a caminhada a frequ?ncia card?aca (FC), percep??o subjetiva do esfor?o (PSE, 6-20) e resposta afetiva (RA, -5/+5) foram monitoradas. A PA ambulatorial foi avaliada durante 20 h (vig?lia: 13 h; sono: 7 h) ap?s as sess?es de caminhada e controle atrav?s da monitoriza??o ambulatorial da press?o arterial (MAPA). Os resultados est?o descritos em m?dia e intervalo de confian?a de 95%. A PA sist?lica e diast?lica no per?odo de 20 h, vig?lia e sono foram comparadas entre as sess?es caminhada e controle usando o teste de t de Student pareado. A ANOVA two-way (condi??o vs. tempo) com medidas repetidas no segundo fator foi utilizada para comparar os valores m?dios de PA ambulatorial nos per?odos 1-6 h e 7-13 h (vig?lia) e 14-20 h (sono) ap?s as sess?es caminhada e controle. O p?s-teste de Bonferroni foi utilizado para verificar as diferen?as pontuais. Um p-valor < 0,05 foi considerado estatisticamente significativo. RESULTADOS: a intensidade de caminhada autosselecionada foi 58,6% (54,1-63,5) da FC de reserva, a PSE foi 11 (10-12) e a RA foi +3 (3-4). A PA sist?lica foi 3,4 mmHg (0,9-5,9) e 4,0 mmHg (1,6-6,4) menor nas m?dias dos per?odos de 20 h e vig?lia, respectivamente, ap?s a sess?o de caminhada quando comparada a sess?o controle (p < 0,05). A redu??o da PA sist?lica p?s-caminhada apresentou maior magnitude nas seis primeiras horas (6 mmHg; p < 0,05). N?o houve redu??o da PA sist?lica p?s-caminhada no per?odo do sono (p > 0.05). Nenhuma altera??o da PA diast?lica p?s-caminhada foi observada no per?odo de 20 h, vig?lia e sono em rela??o ? sess?o controle (p > 0,05). Foi observada redu??o da carga press?rica sist?lica (6,3%) e variabilidade da PA sist?lica (6,2 unidades arbitr?rias) p?s-caminhada no per?odo de 20 h (p < 0,05). Houve correla??o forte e positiva entre a redu??o da PA sist?lica nas seis primeiras hora p?s-caminhada com a redu??o no per?odo de 20 h (r = 0,68; p <0,001). CONCLUS?O: uma sess?o de caminhada em intensidade autosselecionada ao ar livre reduz a PA sist?lica m?dia no per?odo de 20 h e vig?lia em idosas hipertensas, essencialmente pela HPE nas primeiras seis horas p?s-exerc?cio. Al?m disso, reduz a carga press?rica sist?lica e variabilidade da PA sist?lica no per?odo de 20 h. Considerando que as idosas percebem a sess?o como leve-moderada e prazerosa, a caminhada em intensidade autosselecionada parece ser uma alternativa interessante para recomenda??o inicial de exerc?cio para idosas hipertensas fisicamente inativas. / OBJETIVO: analisar o efeito de uma sess?o de caminhada em intensidade autosselecionada ao ar livre sobre a press?o arterial (PA) ambulatorial de idosas hipertensas fisicamente inativas. METODOLOGIA: vinte idosas hipertensas medicadas (64,9 ? 4,5 anos; 29,0 ? 4,3 kg/m?; PA de repouso 121,5 ? 11,2 / 59,5 ? 7,9 mmHg) e fisicamente inativas (< 8.000 passos/dia) completaram esse ensaio cl?nico controlado e randomizado, com delineamento cruzado. Ap?s avalia??o inicial, as idosas participaram de duas sess?es em ordem randomizada, com uma semana de intervalo entre elas: i) sess?o de caminhada em intensidade autosselecionada ao ar livre (pista de 400 m) e ii) sess?o controle (sem exerc?cio). Ambas as sess?es foram realizadas pela manh? entre 7:00-8:00 h. Durante a caminhada a frequ?ncia card?aca (FC), percep??o subjetiva do esfor?o (PSE, 6-20) e resposta afetiva (RA, -5/+5) foram monitoradas. A PA ambulatorial foi avaliada durante 20 h (vig?lia: 13 h; sono: 7 h) ap?s as sess?es de caminhada e controle atrav?s da monitoriza??o ambulatorial da press?o arterial (MAPA). Os resultados est?o descritos em m?dia e intervalo de confian?a de 95%. A PA sist?lica e diast?lica no per?odo de 20 h, vig?lia e sono foram comparadas entre as sess?es caminhada e controle usando o teste de t de Student pareado. A ANOVA two-way (condi??o vs. tempo) com medidas repetidas no segundo fator foi utilizada para comparar os valores m?dios de PA ambulatorial nos per?odos 1-6 h e 7-13 h (vig?lia) e 14-20 h (sono) ap?s as sess?es caminhada e controle. O p?s-teste de Bonferroni foi utilizado para verificar as diferen?as pontuais. Um p-valor < 0,05 foi considerado estatisticamente significativo. RESULTADOS: a intensidade de caminhada autosselecionada foi 58,6% (54,1-63,5) da FC de reserva, a PSE foi 11 (10-12) e a RA foi +3 (3-4). A PA sist?lica foi 3,4 mmHg (0,9-5,9) e 4,0 mmHg (1,6-6,4) menor nas m?dias dos per?odos de 20 h e vig?lia, respectivamente, ap?s a sess?o de caminhada quando comparada a sess?o controle (p < 0,05). A redu??o da PA sist?lica p?s-caminhada apresentou maior magnitude nas seis primeiras horas (6 mmHg; p < 0,05). N?o houve redu??o da PA sist?lica p?s-caminhada no per?odo do sono (p > 0.05). Nenhuma altera??o da PA diast?lica p?s-caminhada foi observada no per?odo de 20 h, vig?lia e sono em rela??o ? sess?o controle (p > 0,05). Foi observada redu??o da carga press?rica sist?lica (6,3%) e variabilidade da PA sist?lica (6,2 unidades arbitr?rias) p?s-caminhada no per?odo de 20 h (p < 0,05). Houve correla??o forte e positiva entre a redu??o da PA sist?lica nas seis primeiras hora p?s-caminhada com a redu??o no per?odo de 20 h (r = 0,68; p <0,001). CONCLUS?O: uma sess?o de caminhada em intensidade autosselecionada ao ar livre reduz a PA sist?lica m?dia no per?odo de 20 h e vig?lia em idosas hipertensas, essencialmente pela HPE nas primeiras seis horas p?s-exerc?cio. Al?m disso, reduz a carga press?rica sist?lica e variabilidade da PA sist?lica no per?odo de 20 h. Considerando que as idosas percebem a sess?o como leve-moderada e prazerosa, a caminhada em intensidade autosselecionada parece ser uma alternativa interessante para recomenda??o inicial de exerc?cio para idosas hipertensas fisicamente inativas.
12

Valida??o de instrumentos para avalia??o da habilidade e do conhecimento acerca da medida da press?o arterial / Validation of instrument for evaluation the ability and knowledge of blood pressure measurement

Tib?rcio, Manuela Pinto 21 February 2013 (has links)
Made available in DSpace on 2014-12-17T14:46:58Z (GMT). No. of bitstreams: 1 ManuelaPT_DISSERT.pdf: 1435206 bytes, checksum: c035d2139436ef5c5fa0929826396e1d (MD5) Previous issue date: 2013-02-21 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / This study aimed to validate tools for evaluating the ability and knowledge about blood pressure (BP) among nursing students. It is a cross-sectional, descriptive, quantitative and methodological study accomplished at the Universidade Federal do Rio Grande do Norte (UFRN), Universidade do Estado do Rio Grande do Norte (UERN) and a private university of the state. The sample consisted of 27 judges of research selected from the inclusion criteria: nursing, teachers of the semiology and/or semiotics discipline, with at least 1 year of experience, being from UFRN, EEN, UERN and private university of the state and and agree to participate voluntarily with the signing of the consent form. The research was development in three stages: construction of two instruments based on the scientific literature, resulting in a structured checklist consists of 28 items and a knowledge questionnaire with 12 questions; submission of the instruments to the judges, in the period from June to September 2012, which should evaluate each item in appropriate , appropriate with changes and inappropriate , addition to making an overall assessment of each instrument based on 10 requirements; validation and verification to the level of agreement among the judges, through the application of Kappa and Content Validity Index (CVI). Was used the consensus level greater than 0.61 (good) to the Kappa index and greater than 0.75 for CVI. Was approved by the Ethics in Research / HUOL. After being coded and tabulated, the data were analyzed using descriptive statistics. Of the 27 judges who evaluated the instrument, 77.8% are female, with a mean age of 36.6 (? 9.0) years, 63.0% worked in UFRN, 74.1% had academic master and 63.0% worked exclusively on teaching. Average length of teaching experience was 7.9 (? 8.0) years and in the semiology and/or semiotics discipline of 5.5 (? 6.7) years. In the judgment of structured checklist and questionnaire of knowledge about blood pressure mensurement any item/question was considered inappropriate since all obtained level of agreement within the indices established (CVI> 0,75 E Kappa> 0.61). In relation to structured checklist, of those 28 items present, 9 showed perfect concordance index (CVI = 1.00, Kappa = 1.00) and another 19 were considered appropriate with changes, especially with regard to clarity and vocabulary. In the questionnaire of knowledge, among the 12 questions that comprised, 7 had perfect concordance index and the others were considered appropriate with changes as requirements as clarity, vocabulary, and feasible sequence of instructional topics. In terms of a overall evaluating of instruments, the structured checklist got CVI of 0.94 and Kappa of 0.89 and the knowledge questionnaire, CVI of 0.97 and a kappa of 0.94. Both instruments proved to be valid as to their content, configuring it as clear and objective tools of assessment of knowledge and ability on blood pressure, being of nursing students as well as others students and health professionals, since the use of valid measures seeking to reduce the risk of distorting the results / Este estudo teve como objetivo validar instrumentos para avalia??o da habilidade e do conhecimento acerca da medida da press?o arterial (PA) entre os graduandos de enfermagem. Estudo transversal, descritivo, quantitativo e metodol?gico realizado na Universidade Federal do Rio Grande do Norte/UFRN, Universidade do Estado do Rio Grande do Norte/UERN e em uma universidade privada do estado. A amostra composta por 27 ju?zes da pesquisa selecionados a partir dos crit?rios de inclus?o: enfermeiros, docentes da disciplina de semiologia e/ou semiot?cnica, m?nimo de um ano de experi?ncia nas disciplinas, ser da UFRN, UERN ou de uma universidade privada do Rio Grande do Norte e aceitar participar voluntariamente com a assinatura do Termo de Consentimento Livre Esclarecido. A pesquisa foi desenvolvida em tr?s etapas: constru??o de dois instrumentos com base na literatura cient?fica, resultando em um roteiro de observa??o estruturado composto por 28 itens e um question?rio do conhecimento com 12 quest?es; submiss?o dos instrumentos aos ju?zes, no per?odo de junho a setembro de 2012, os quais deveriam avaliar cada item em adequado , adequado com altera??es e inadequado , al?m de fazer uma avalia??o geral de cada instrumento baseada em 10 requisitos; e valida??o com a verifica??o do n?vel de concord?ncia entre os ju?zes, atrav?s da aplica??o do ?ndice Kappa e do ?ndice de Validade de conte?do (IVC). Utilizou-se o n?vel de consenso maior que 0,61 (bom) para o ?ndice Kappa e maior que 0,75 para o IVC. Obteve parecer favor?vel do Comit? de ?tica em Pesquisa/HUOL. Ap?s serem codificados e tabulados, os dados foram analisados por meio de estat?stica descritiva. Dos 27 ju?zes que avaliaram o instrumento, 77,8% s?o do sexo feminino, com m?dia de idade de 36,6 (? 9,0) anos, 63,0% atuavam na UFRN, 74,1% possu?am mestrado acad?mico e 63,0% atuavam exclusivamente na doc?ncia. A m?dia de tempo de experi?ncia na doc?ncia foi de 7,9 (? 8,0) anos e nas disciplinas de semiologia e/ou semiot?cnica da enfermagem foi de 5,5 (? 6,7) anos. No julgamento do roteiro de observa??o estruturado e do question?rio do conhecimento acerca da medida da PA nenhum item/quest?o foi considerado inadequado, uma vez que todos obtiveram n?vel de concord?ncia dentro dos ?ndices estabelecidos (IVC > a 0,75 E Kappa > 0,61). Em rela??o ao roteiro estruturado, dos 28 itens presentes, 9 apresentaram ?ndice de concord?ncia perfeito (IVC=1,00; Kappa= 1,00) e outros 19 foram considerados adequados com altera??es, principalmente no que diz respeito ? clareza e vocabul?rio. No question?rio do conhecimento, dentre as 12 quest?es que o compunham, 7 apresentaram ?ndice de concord?ncia perfeito e as demais foram consideradas adequadas com altera??es quanto requisitos clareza, vocabul?rio, exequ?vel e sequ?ncia instrucional dos t?picos. Em se tratando da avalia??o geral dos instrumentos, o roteiro estruturado obteve IVC de 0,94 e Kappa de 0,89 e o question?rio do conhecimento, IVC de 0,97 e Kappa de 0,94. Os dois instrumentos mostraram-se v?lidos quanto ao seu conte?do, configurando-se como ferramentas objetivas e claras de avalia??o dos conhecimentos e habilidades acerca da press?o arterial, seja dos graduandos de enfermagem como tamb?m de outros estudantes e profissionais da sa?de, uma vez que a utiliza??o de medidas v?lidas busca a redu??o do risco de distor??o dos resultados
13

Controlador preditivo generalizado multi-modelo aplicado ao controle de press?o arterial

Silva, Humberto Ara?jo da 19 March 2010 (has links)
Made available in DSpace on 2014-12-17T14:55:44Z (GMT). No. of bitstreams: 1 HumbertoAS_DISSERT.pdf: 1011716 bytes, checksum: 2b872372fd085e114502d8002132d6ba (MD5) Previous issue date: 2010-03-19 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Postsurgical complication of hypertension may occur in cardiac patients. To decrease the chances of complication it is necessary to reduce elevated blood pressure as soon as possible. Continuous infusion of vasodilator drugs, such as sodium nitroprusside (Nipride), would quickly lower the blood pressure in most patients. However, each patient has a different sensitivity to infusion of Nipride. The parameters and the time delays of the system are initially unknown. Moreover, the parameters of the transfer function associated with a particular patient are time varying. the objective of the study is to develop a procedure for blood pressure control i the presence of uncertainty of parameters and considerable time delays. So, a methodology was developed multi-model, and for each such model a Preditive Controller can be a priori designed. An adaptive mechanism is then needed for deciding which controller should be dominant for a given plant / Em muitos procedimentos cir?rgicos existe a necessidade de realizar o controle da press?o arterial para, com isto, preservar a sa?de do paciente. Para diminuir as chances de uma complica??o, ? necess?rio reduzir a press?o arterial o mais r?pido poss?vel. A infus?o cont?nua de drogas vasodilatadoras, como o nitroprussiato de s?dio (NPS), reduz rapidamente a press?o arterial na maioria dos pacientes. Por?m, cada paciente tem uma sensibilidade diferente a infus?o do NPS, o que faz com que os par?metros e os atrasos do sistema sejam desconhecidos a priori. Al?m disso, os par?metros de uma fun??o de transfer?ncia associados ? um paciente particular s?o variantes no tempo. Desta forma, o objetivo do trabalho consiste em desenvolver uma metodologia capaz de controlar de forma autom?tica a press?o arterial na presen?a de incertezas de par?metros e de grandes atrasos. Para isso foi desenvolvida uma metodologia multi-modelo, onde para cada modelo existe um Controlador Preditivo especificamente sintonizado, e um mecanismo adaptativo decide qual controlador deve ser o dominante para uma determinada planta
14

Efeito agudo do exerc?cio intervalado de alta intensidade de baixo volume sobre a press?o arterial ambulatorial de normotensos / Acute effect of low-volume high-intensity interval exercise on ambulatorial blood pressure in normotensive

Dantas, Teresa Cristina Batista 31 August 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-07-04T14:08:48Z No. of bitstreams: 1 TeresaCristinaBatistaDantas_DISSERT.pdf: 2035837 bytes, checksum: 9e4bbb8e58581fb11c89382b14e4a5b1 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-07-13T14:55:41Z (GMT) No. of bitstreams: 1 TeresaCristinaBatistaDantas_DISSERT.pdf: 2035837 bytes, checksum: 9e4bbb8e58581fb11c89382b14e4a5b1 (MD5) / Made available in DSpace on 2017-07-13T14:55:41Z (GMT). No. of bitstreams: 1 TeresaCristinaBatistaDantas_DISSERT.pdf: 2035837 bytes, checksum: 9e4bbb8e58581fb11c89382b14e4a5b1 (MD5) Previous issue date: 2016-08-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Introdu??o: estudos demonstram a ocorr?ncia de hipotens?o p?s-exerc?cio (HPE) ap?s ~60 minutos de exerc?cio intervalado de alta intensidade (EIAI) em normotensos. Entretanto, existe uma lacuna no que se refere a HPE ambulatorial e ainda n?o ? conhecido se os modelos de EIAI de baixo volume s?o capazes de reduzir a press?o arterial (PA) ambulatorial em normotensos. Objetivo: investigar o efeito de uma sess?o de EIAI de baixo volume sobre a PA ambulatorial de normotensos. M?todos: vinte e um homens normotensos (23,6 ? 3,6 anos; 23,5 ? 2,3 kg/m2; PA de repouso 111,1 ? 6,4 / 62,4 ? 6,1 mmHg) realizaram: (i) teste incremental m?ximo; (ii) sess?o EIAI e controle (sem exerc?cio) em ordem randomizada. O EIAI consistiu de 10x60s a 100% da velocidade m?xima atingida no teste de esfor?o intercalado com 60s de recupera??o passiva. Os sujeitos permaneceram 20h com o aparelho de Monitoriza??o Ambulatorial da Press?o Arterial (MAPA). Foram avaliadas 13h de vig?lia e 7h de sono. O teste t de Student pareado foi utilizado para comparar a PA sist?lica e diast?lica entre as sess?es controle e EIAI. A ANOVA two-way (condi??o vs. tempo) foi usada para comparar a PA ambulatorial hora a hora ap?s as sess?es controle e EIAI. Resultados: a PA sist?lica no per?odo de 20h de an?lise reduziu 2,8 ? 3,7 mmHg e a PA diast?lica reduziu 1,7 ? 3,5 mmHg ap?s a sess?o de EIAI em rela??o ? sess?o controle (p<0,05). No per?odo da vig?lia, a PA sist?lica reduziu 3,2 ? 3,7 mmHg e a PA diast?lica 1,8 ? 3,9 mmHg ap?s a sess?o de EIAI em rela??o ? sess?o controle (p<0,05). N?o houve diferen?a na PA sist?lica e diast?lica durante o per?odo do sono (p>0,05). A ANOVA two-way demostrou que a PA sist?lica foi menor nas primeiras cinco horas ap?s a sess?o EIAI comparada a sess?o controle [delta m?nimo: -3,2 mmHg; delta m?ximo: -4,8 mmHg (p<0,05)]. Conclus?es: uma sess?o de EIAI de baixo volume reduziu a PA na vig?lia e no per?odo de 20h em normotensos. A hipotens?o em maior magnitude ocorrida nas primeiras cinco horas p?s-exerc?cio parecer explicar a redu??o da PA na vig?lia e no per?odo de 20h. / Introduction: Previous research have already shown the occurrence of post-exercise hypotension (PEH) after ~60 minutes of high-intensity interval exercise (HIIE) in normotensive subjects. However, there is a gap with regard to ambulatory PEH and it is not yet knowns if the low-volume HIIE reduces ambulatory blood pressure (BP) in normotensive subjects. Objective: To investigate the effect of a single session of low-volume HIIE on ambulatory BP in normotensive subjects. Methods: Twenty-one normotensive males (23.6 ? 3.6 years, 23.5 ? 2.3 kg/m2, resting PA 111.1 ? 6.4 / 62.4 ? 6.1 mmHg) performed: (i) maximum incremental test; (ii) HIIE and control sessions in a randomized order. The HIIE consisted of 10x60s at 100% of maximal velocity interspersed by 60s of passive recovery. The paired sample t-test was used to compare systolic and diastolic BP between control and HIIE sessions. A two-way ANOVA (condition vs. time) was used to compare the ambulatory BP response hour to hour following the control and HIIE sessions. Results: Systolic BP in the 20-hour analysis reduced 2.8 ? 3.7 mmHg and diastolic BP reduced 1.7 ? 3.5 mmHg after the HIIE session compared to the control session (p<0.05). In the awake period, systolic BP decreased 3.2 ? 3.7 mmHg and diastolic BP 1.8 ? 3.9 mmHg after the HIIE session compared to the control session (p<0.05). There was no difference in the systolic and diastolic BP during the asleep period (p> 0.05). The two-way ANOVA demonstrated that systolic BP was lower in the first five hours after the HIIE session compared to the control session [minimum delta: -3.2 mmHg; maximum delta: -4.8 mmHg (p <0.05)]. Conclusion: A single session of low-volume HIIE reduces ambulatory BP in normotensive. The greater magnitude of hypotension during the first five hours post-exercise seems to explain the BP reduction in 20h and awake periods.

Page generated in 0.0992 seconds