• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An?lise da transfer?ncia de calor de fluidos t?rmicos aditivado com etilenoglicol e pol?meros / Heat transfer analysis of thermal fluids additive with ethylene glycol and polymers

Santana, Rony Oliveira de 19 December 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-04-03T19:57:46Z No. of bitstreams: 1 RonyOliveiraDeSantana_DISSERT.pdf: 3552291 bytes, checksum: 7287cd95690c8efbcd000e256538b3d5 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-04-06T21:03:00Z (GMT) No. of bitstreams: 1 RonyOliveiraDeSantana_DISSERT.pdf: 3552291 bytes, checksum: 7287cd95690c8efbcd000e256538b3d5 (MD5) / Made available in DSpace on 2017-04-06T21:03:00Z (GMT). No. of bitstreams: 1 RonyOliveiraDeSantana_DISSERT.pdf: 3552291 bytes, checksum: 7287cd95690c8efbcd000e256538b3d5 (MD5) Previous issue date: 2016-12-19 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / Um sistema de arrefecimento ? usado para manter a temperatura ideal de funcionamento e evitar sobreaquecimento, atrav?s de um fluido t?rmico tamb?m chamado fluido de arrefecimento e um trocador de calor. Os fluidos de arrefecimento s?o normalmente compostos por uma solu??o de ?gua e um aditivo, al?m de aditivos inibidores de corros?o e corantes. O etilenoglicol ? um tipo de ?lcool amplamente utilizado como aditivo por ser totalmente sol?vel, com baixa ou nenhuma atividade corrosiva e quimicamente est?vel, al?m de reduzir a press?o de vapor da ?gua. A redu??o da press?o de vapor da solu??o garante aumento do ponto de ebuli??o (ebulioscopia), permitindo uma maior efici?ncia de troca t?rmica do fluido em temperaturas mais elevadas sem mudan?a de fase, tamb?m ? obtida uma diminui??o do ponto de congelamento da ?gua (crioscopia). Por ser t?xico, o etilenoglicol sofre atualmente concorr?ncia de aditivos org?nicos polim?ricos de alta condutividade t?rmica, desenvolvidos para ter um comportamento t?rmico semelhante ao etilenoglicol, com a vantagem de ser at?xicos e biodegrad?veis. Este trabalho desenvolveu an?lises experimentais para caracteriza??o energ?tica de dois fluidos comerciais de arrefecimento, um a base de etilenoglicol e outro a base de pol?mero, foram realizadas an?lises que estimaram suas propriedades termof?sicas a fim de verificar a efici?ncia energ?tica do processo de transfer?ncia de calor no aparato experimental, desenvolvido como parte integrante deste trabalho. / A cooling system is used to maintain the ideal operating temperature and prevent overheating, through a thermal fluid also called cooling fluid and a heat exchanger. Cooling fluids are usually composed of a solution of water and an additive, as well as corrosion inhibiting additives and colorants. Ethylene glycol is a type of alcohol widely used as an additive because it is completely soluble, with little or no corrosive and chemically stable activity, and also reduces the water vapor pressure. The reduction of the vapor pressure of the solution guarantees boiling point increase (ebullioscopy), allowing a higher thermal exchange efficiency of the fluid at higher temperatures without phase change, also a decrease in the freezing point of the water (cryoscopy) . Because it is toxic, ethylene glycol currently undergoes competition from organic additives with high thermal conductivity, developed to have a thermal behavior similar to ethylene glycol, with the advantage of being non-toxic and biodegradable. This work developed experimental analyzes for the energy characterization of two commercial cooling fluids, one based on ethylene glycol and another based on polymer. Analyzes were carried out to estimate its thermophysical properties in order to verify the energy efficiency of the heat transfer process in the apparatus Developed as an integral part of this work.
2

Estudo das propriedades termof?sicas com varia??o da expansibilidade de comp?sito desenvolvido com matriz PUR-NOP e carga funcional de argilomineral

Rahn, Marco Aur?lio dos Santos 11 July 2011 (has links)
Made available in DSpace on 2014-12-17T14:57:51Z (GMT). No. of bitstreams: 1 MarcoASR_TESE.pdf: 5586767 bytes, checksum: d92d904a4f89177a814a13f5f7230b94 (MD5) Previous issue date: 2011-07-11 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / In this study were conducted experimental procedures for determination of variation of the expandability of rigid polyurethane foam (PUR) from a natural oil polyol (NOP), specifically the Castor oil plant, Ricinus communis, pure and additions of the vermiculite in phase dispersed in different percentage within a range from 0% to 20%, mass replacement. From the information acquired, were defined the parameters for production of bodies of test, plates obtained through controlled expansion, with the final volume fixed. Initially, the plates were subjected to thermal performance tests and evaluated the temperature profiles, to later be extracted samples duly prepared in accordance with the conditions required for each test. Was proceeded then the measurement of the coefficient of thermal conductivity, volumetric capacity heat and thermal diffusivity. The findings values were compared with the results obtained in the tests of thermal performance, contributing to validation of the same. Ultimately, it was investigated the influence that changes in physical-chemical structure of the material had exerted on the variation of thermophysical quantities through gas pycnometry, scanning electron microscopy (SEM) combined with energy dispersive X-ray fluorescence spectroscopy (EDXRF), infrared spectroscopy using Fourier transform (FTIR), thermogravimetric analysis (TGA) and differential thermal analysis (DTA). Based on the results obtained was possible to demonstrate that all load percentage analyzed promoted an increase in the potential expansion (PE) of the resin. In production of the plates, the composites with density near at the free expansion presented high contraction during the cure, being the of higher density adopted as definitive standard. In the thermal performance tests, the heating and cooling curves of the different composites had presented symmetry and values very close for lines of the temperature. The results obtained for the thermophysical properties of composites, showed little difference in respect of pure foam. The percentage of open pores and irregularities in the morphology of the composites were proportionate to the increment of vermiculite. In the interaction between the matrix and dispersed phase, there were no chemical transformations in the region of interface and new compounds were not generated. The composites of PUR-NOP and vermiculite presented thermal insulating properties near the foam pure and percentage significantly less plastic in its composition, to the formulation with 10% of load / Neste estudo, foram realizados procedimentos experimentais para determina??o da varia??o da expansibilidade da espuma r?gida de poliuretano (PUR) de um poliol de ?leo natural (NOP), especificamente o de mamona, Ricinus communis, puro e acrescido de vermiculita na fase dispersa, em distintos percentuais, dentro de uma faixa de 0% a 20%, de substitui??o em massa. A partir das informa??es adquiridas, foram definidos os par?metros para produ??o dos corpos de prova, placas obtidas atrav?s de expans?o controlada, com volume final fixo. Inicialmente, as placas foram submetidas a testes de desempenho t?rmico, sendo avaliados os perfis de temperatura, para posteriormente serem extra?das amostras, devidamente preparadas conforme as condi??es exigidas para cada ensaio. Procedeu-se ent?o a medi??o do coeficiente de condutividade t?rmica, capacidade t?rmica volum?trica e difusividade t?rmica. Os valores encontrados foram comparados com os resultados obtidos nos testes de desempenho t?rmico, contribuindo para valida??o dos mesmos. Por fim, foi investigada a influ?ncia que as altera??es na estrutura f?sico-qu?mica do material, exerceram sobre a varia??o das grandezas termof?sicas, por meio de picnometria a g?s, microscopia eletr?nica de varredura (MEV) combinada com espectroscopia de fluoresc?ncia de raios-X por energia dispersiva (EDXRF), espectroscopia de infravermelho com transformada de Fourier (FTIR), an?lise termogravim?trica (TGA) e an?lise t?rmica diferencial (DTA). Com base nos resultados obtidos foi poss?vel demonstrar que todos os percentuais de carga analisados promoveram um aumento do potencial de expans?o (PE) da resina. Na produ??o das placas, os comp?sitos com densidade pr?xima ? expans?o livre apresentaram grande contra??o na cura, sendo adotados os de maior densidade como padr?o definitivo. Nos ensaios de desempenho t?rmico, as curvas de aquecimento e resfriamento dos diferentes comp?sitos apresentaram simetria e valores muito pr?ximos para as linhas de temperatura. Os resultados obtidos para as propriedades termof?sicas dos comp?sitos, demonstraram pouca diferen?a em rela??o aos da espuma pura. O percentual de poros abertos e irregularidades na morfologia dos comp?sitos foram proporcionais ao incremento da vermiculita. Na intera??o entre matriz e fase dispersa n?o ocorreram transforma??es qu?micas na regi?o de interface e n?o foram gerados novos compostos. Os comp?sitos de PUR-NOP e vermiculita apresentaram propriedades isolantes t?rmicas pr?ximas as da espuma pura e percentual significativamente menor de pl?stico em sua composi??o, para a formula??o com 10% de carga
3

Estudo do aproveitamento de res?duo de gesso como carga para comp?sito com matriz de resina expansiva de mamona

Oliveira Neto, Manoel Leonel de 16 February 2012 (has links)
Made available in DSpace on 2014-12-17T14:57:53Z (GMT). No. of bitstreams: 1 ManoelLON_TESE.pdf: 2837089 bytes, checksum: 962b0c298a9cc0d199caa357de4ce608 (MD5) Previous issue date: 2012-02-16 / In the execution of civil engineering works, either by wasting during the coating of wall or demolition of gypsum walls, the generation of the gypsum waste involves serious environmental concerns. These concerns are increased by the high demand of this raw material in the sector and by the difficulties of proper disposal byproduct generated. In the search for alternatives to minimize this problem, many research works are being conducted, giving emphasis in using gypsum waste as fillers in composites materials in order to improve the acoustic, thermal and mechanical performances. Through empirical testing, it was observed that the crystallization water contained in the residue (CaSO4.2H2O) could act like primary agent in the expanding of the polyurethane foam. Considering that polyurethane produced from vegetable oils are biodegradable synthetic polymers and that are admittedly to represent an alternative to petrochemical synthetic polyurethane, this research consist an analysis of the thermal behavior of a composite whose matrix obtained from a resin derived from the expansive castor oil seed, with loads of 4%, 8%, 12% and 16% of gypsum waste replacing to the polyol prepolymer blend. Contributors to this analysis: a characterization of the raw material through analysis of spectroscopy by Fourier transform infrared (FTIR), chemical analysis by X-Ray Fluorescence (XRF) and mineralogical analysis by X Ray Diffraction (XRD), complemented by thermo gravimetric analysis (TGA). In order to evaluate the thermo physical properties and thermal behavior of the composites manufactured in die closed with expansion contained, were also carried tests to determine the percentage of open pore volume using a gas pycnometer, scanning electronic microscopy (SEM), in addition to testing of flammability and the resistance to contact with hot surfaces. Through the analysis of the results, it appears that it is possible to produce a new material, which few changes in their thermo physical properties and thermal performance, promotes significant changes and attractive to the environment / Na execu??o de obras na constru??o civil, seja por desperd?cio de gesso durante o revestimento de paredes ou na demoli??o de paredes de gesso acartonado, a gera??o do res?duo implica em preocupa??es ambientais decorrentes da alta demanda dessa mat?ria prima no setor e da dificuldade de destina??o adequada ao subproduto gerado. Na busca por uma alternativa que atenue o problema, muitas pesquisas t?m sido realizadas com ?nfase na utiliza??o do res?duo de gesso como carga em comp?sitos, com o intuito de melhorar os desempenhos ac?stico, t?rmico e mec?nico. Atrav?s de ensaios emp?ricos, observou-se que a ?gua de cristaliza??o contida no res?duo (CaSO4.2H2O) pode atuar como agente prim?rio no processo de expans?o de espumas de poliuretano. Considerando que os poliuretanos, derivados de ?leos vegetais, s?o pol?meros sint?ticos biodegrad?veis e que, reconhecidamente, representam uma alternativa aos poliuretanos sint?ticos petroqu?micos, a presente pesquisa procura fazer uma an?lise do comportamento t?rmico de um comp?sito desenvolvido com matriz de resina vegetal derivada do ?leo de mamona, com cargas de 4%, 8%, 12% e 16% de res?duo de gesso em substitui??o ? mistura poliol + pr?-pol?mero. Contribu?ram para esta an?lise: caracteriza??o da mat?ria prima por meio de espectroscopia de absor??o na regi?o do infravermelho por transformada de Fourier (FTIR), an?lise qu?mica por FRX e mineral por DRX e an?lise termogravim?trica (TGA e DTA). Com o prop?sito de avaliar as propriedades termof?sicas e o comportamento t?rmico dos comp?sitos produzidos com expans?o contida por fechamento do molde. Tamb?m foram realizados ensaios para determina??o do percentual de poros abertos, por meio de picn?metro a g?s, morfologia dos comp?sitos (MEV), al?m de ensaios de inflamabilidade e de resist?ncia ao contato com superf?cies aquecidas. Mediante a an?lise dos resultados obtidos, constatou-se a possibilidade de produ??o de um novo material para isola??o t?rmica, apresentando poucas altera??es em suas propriedades Termof?sicas, assim como em seu desempenho t?rmico, promovendo altera??es significativas e atraentes ao meio ambiente
4

An?lise das propriedades termof?sicas, mec?nicas e geom?tricas de telhas cer?micas queimadas em forno caieira e forno ab?bada

Morais, Dabney S?rgio Guedes de 31 March 2011 (has links)
Made available in DSpace on 2014-12-17T14:58:05Z (GMT). No. of bitstreams: 1 DabneySGM_DISSERT.pdf: 1770376 bytes, checksum: 5e5a6ea101ce8878066e0256504f801a (MD5) Previous issue date: 2011-03-31 / In the industry of ceramic in Rio G. do Norte, tile stands out as the most manufactured product by this industry, being the intermittent kiln ab?bada and caieira the principal type of kiln used in burning. There was a need to make a study of the influence exerted by the type of kiln in which tiles are burnt in their thermo physical properties. The analysis started with 24 raw samples of tile, which was split in two groups of 12 samples and burnt in Ab?bada and Caieira kiln. Besides that, it was made study of the tax of heat transfer to the environment (for each kiln). After having been burnt the samples were taken for laboratory analysis. The properties verified were impermeability, determination of dry mass, absorption of water, the load of bending rupture and its geometric characteristics, the tests were conducted following the currents standards. The tests were carried out according to the ABNT - NBR 15310. The calculation of the rate of heat transfer showed that the ab?bada kiln is more efficient than the Caieira, however the results of tests on the samples revealed no superiority of one over another sample. So the furnace had no influence on the performance of the ceramic tiles / Na ind?stria de cer?mica vermelha a telha desponta como o produto mais fabricado pela ind?stria de cer?mica do Serid?/RN, sendo os fornos intermitentes do tipo ab?bada e caieira os mais utilizados para a queima destas telhas. Verificou-se a necessidade de se fazer um estudo da influ?ncia exercida pelo tipo de forno no qual as telhas s?o queimadas nas suas propriedades termof?sicas, mec?nicas e geom?tricas. Sendo selecionadas 24 amostras de um mesmo processo de fabrica??o, no entanto estas foram posteriormente separadas em dois lotes de 12 unidades e levadas a queima no forno caieira e ab?bada. ? importante ressaltar que os corpos de prova n?o fazem parte do processo produtivo das cer?micas de onde foram utilizados os fornos para queima, ou seja, as cer?micas gentilmente cederam seus fornos para a realiza??o do experimento. Foi realizado um estudo da taxa de transfer?ncia de calor ao meio ambiente para cada tipo de forno. Assim as amostras ap?s serem queimadas foram levadas para an?lise em laborat?rio. As propriedades verificadas foram ? impermeabilidade, determina??o da massa seca e da absor??o da ?gua, determina??o da carga de ruptura ? flex?o e de suas caracter?sticas geom?tricas. Os ensaios foram realizados segundo a norma ABNT - NBR 15310. O calculo da taxa de transfer?ncia de calor mostrou que o forno ab?bada ? mais eficiente que o caieira, no entanto os resultados dos ensaios nas amostras mostraram que n?o houve superioridade de uma amostra sobre outra, assim os fornos n?o tiveram influ?ncia no desempenho das telhas
5

Desenvolvimento e caracteriza??o de solu??es tern?rias ?gua-glicerol-propilenoglicol como fluido refrigerante secund?rio / Development and Characterization of Ternary Solutions Glycerol-Propylene Glycol-Water like Secondary Coolant Fluid

Medeiros, Pedro Samuel Gomes 17 December 2012 (has links)
Made available in DSpace on 2014-12-17T14:58:19Z (GMT). No. of bitstreams: 1 PedroSGM_DISSERT.pdf: 2326508 bytes, checksum: 0470d41afc69c7b0199856916c484045 (MD5) Previous issue date: 2012-12-17 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Cada vez mais o mundo est? adotando uma matriz energ?tica limpa e sustent?vel, com o uso da agricultura para produ??o de agroenergia e combust?veis verdes, como bioetanol e biodiesel. A produ??o do biodiesel gera um coproduto, a glicerina, em que as usinas produtoras t?m dificuldades com o destino do seu excedente. V?rias pesquisas est?o sendo desenvolvidas para nortear diferentes usos do glicerol (glicerina pura). O glicerol possui total solubilidade com a ?gua e pode ser usado como aditivo anticongelante aplicado como fluido refrigerante secund?rio, em sistemas de refrigera??o indireta e com termoacumula??o. Tamb?m, o glicerol ? uma mat?ria-prima alternativa na produ??o de propilenoglicol, um ?lcool de grande aplicabilidade industrial inclusive como anticongelante. Por?m, o melhor ?lcool anticongelante ? o etilenoglicol, um ?lcool t?xico derivado do petr?leo. As solu??es ?gua-glicerol (AG) e ?gua-propilenoglicol (AP) possuem propriedades termof?sicas de qualidade inferior e desequilibradas se comparadas ?s solu??es ?gua-etilenoglicol (AE). Desta forma, esta pesquisa inovadora teve como prop?sito o desenvolvimento e a caracteriza??o de solu??es tern?rias ?gua-glicerol-propilenoglicol (AGP) como fluidos secund?rios, com propriedades termof?sicas desej?veis e competitivas com as solu??es ?gua-etilenoglicol. Equa??es preditivas simplificadas foram usadas para prever o comportamento das solu??es AGP, onde as seguintes propriedades termof?sicas foram avaliadas e estimadas teoricamente: ponto de congelamento, massa espec?fica, calor espec?fico e condutividade t?rmica. As concentra??es para definir o ponto de congelamento das solu??es AGP foram definidas a partir da Lei de Raoult das propriedades coligativas. A an?lise matem?tica inicial mostrou que as solu??es AGP possuem propriedades mais equilibradas que as solu??es AG e AP e competitiva com a solu??o AE. A comprova??o experimental das solu??es AGP foi feita a partir de ensaios para verificar suas propriedades (massa espec?fica, condutividade t?rmica e viscosidade din?mica), comparando com as solu??es de refer?ncia AG e AP. Os resultados experimentais comprovaram as expectativas iniciais e viabilidade t?cnica do novo fluido secund?rio tern?rio. A grande vantagem dos fluidos AGP ? que s?o at?xicos e derivam de fontes renov?veis

Page generated in 0.0937 seconds