• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 268
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1026
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 87
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Carbon deposition for artificial heart valves using liquid reagent CVD

Watson, Stuart Kent 08 1900 (has links)
No description available.
102

An in vitro investigation of the leakage and hinge flow fields through bileaflet mechanical heart valves and their relevance to thrombogenesis

Ellis, Jeffrey Thomas 05 1900 (has links)
No description available.
103

Durability evaluation of articular cartilage prostheses

Covert, Rebeccah Jean 05 1900 (has links)
No description available.
104

Characterization and control of smooth muscle cell phenotype in vascular tissue engineering

Stegemann, Jan Philip 12 1900 (has links)
No description available.
105

Development and characterization of a prosthetic intervertebral disc

Hudgins, Robert Garryl 12 1900 (has links)
No description available.
106

Effects of neurostimulation via a suprachoroidal vision prosthesis

Wong, Yan Tat, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2009 (has links)
Microelectronic vision prostheses aim to restore visual percepts through electrical stimulation of the surviving visual pathways in the blind. Electrical stimulation has been shown to produce spots of light in the visual field. A neurostimulator that forms the basis of a vision prosthesis was designed using a high voltage CMOS process to allow it to be able to stimulate when faced with high electrode-tissue impedances. It was implemented with novel features that allow it to be scalable, and to focus charge injection, and can stimulate multiple sites simultaneously using a current source and sink at each site. To reduce electrical cross-talk between multiple stimulation sites, six-return electrodes surround each stimulating electrode, electrically guarding them from each other. The six-return electrode configuration was shown to reduce electrical cross-talk in saline bath tests compared to single-return electrode configurations. The neurostimulator was used to evoke responses from cats through electrical stimulation via intravitreal ball electrodes, corneal electrodes, and planar electrode arrays in the suprachoroidal space. Responses were measured on the visual cortex through optical imaging of intrinsic signals, and through surface electrodes. Using the planar electrode array in the suprachoroidal space, responses were elicited to biphasic, bipolar and monopolar stimuli, with each stimulating electrode coupled with either six-return electrodes, two-return electrodes, or a single-return electrode. The average charge threshold to elicit a response for biphasic, bipolar stimulation with six-return electrodes was 76.47 ?? 8.76 nC (standard error of the mean). For biphasic, bipolar stimulation, the magnitude and area of cortical response with the six-return electrode configurations was on average 2.18 ?? 0.19 times smaller than single-return electrode configurations, and 1.89 ?? 0.19 times smaller than two-return electrode configurations (P < 0.0001). It was also found that for biphasic stimulation, a greater magnitude and area of response was elicited for monopolar stimulation compared to bipolar stimulation. This dissertation details the design and testing of a novel, scalable neurostimulator to focus charge injection. It also shows that suprachoroidal, bipolar stimulation can elicit visual responses, and that the area of cortical activation was more focused when using bipolar, biphasic stimulation, and six-return electrodes.
107

Residual kinetics indices a versatile interface for prosthetic control /

Phillips, Sam L. January 2007 (has links)
Thesis (Ph. D.)--Rutgers University, 2007. / "Graduate Program in Biomedical Engineering." Includes bibliographical references (p. 123-131).
108

Numerical studies of flow through prosthetic heart valves /

Thalassoudis, Kym. January 1987 (has links) (PDF)
Thesis (Ph. D.)--University of Adelaide, Dept. of Applied Mathematics, 1987. / Includes bibliographical references (leaves 184-190).
109

Design, development and optimisation of a tissue culture vessel system for tissue engineering applications /

Damen, Bas Stefaan. January 2003 (has links) (PDF)
Thesis (MEng) - Industrial Research Institute Swinburne, Swinburne University of Technology, 2003. / Thesis submitted for the degree of Master of Engineering by Research, Industrial Research Institute Swinburne, Swinburne University of Technology, 2003. Typescript. Includes bibliographical references (p. 159-169).
110

Coagulase-negative staphylococci in prosthetic hip infections /

Nilsdotter, Åsa, January 2005 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2005. / Härtill 5 uppsatser.

Page generated in 0.0596 seconds