1

Effects of neurostimulation via a suprachoroidal vision prosthesis

Wong, Yan Tat, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2009 (has links)
Microelectronic vision prostheses aim to restore visual percepts through electrical stimulation of the surviving visual pathways in the blind. Electrical stimulation has been shown to produce spots of light in the visual field. A neurostimulator that forms the basis of a vision prosthesis was designed using a high voltage CMOS process to allow it to be able to stimulate when faced with high electrode-tissue impedances. It was implemented with novel features that allow it to be scalable, and to focus charge injection, and can stimulate multiple sites simultaneously using a current source and sink at each site. To reduce electrical cross-talk between multiple stimulation sites, six-return electrodes surround each stimulating electrode, electrically guarding them from each other. The six-return electrode configuration was shown to reduce electrical cross-talk in saline bath tests compared to single-return electrode configurations. The neurostimulator was used to evoke responses from cats through electrical stimulation via intravitreal ball electrodes, corneal electrodes, and planar electrode arrays in the suprachoroidal space. Responses were measured on the visual cortex through optical imaging of intrinsic signals, and through surface electrodes. Using the planar electrode array in the suprachoroidal space, responses were elicited to biphasic, bipolar and monopolar stimuli, with each stimulating electrode coupled with either six-return electrodes, two-return electrodes, or a single-return electrode. The average charge threshold to elicit a response for biphasic, bipolar stimulation with six-return electrodes was 76.47 ?? 8.76 nC (standard error of the mean). For biphasic, bipolar stimulation, the magnitude and area of cortical response with the six-return electrode configurations was on average 2.18 ?? 0.19 times smaller than single-return electrode configurations, and 1.89 ?? 0.19 times smaller than two-return electrode configurations (P < 0.0001). It was also found that for biphasic stimulation, a greater magnitude and area of response was elicited for monopolar stimulation compared to bipolar stimulation. This dissertation details the design and testing of a novel, scalable neurostimulator to focus charge injection. It also shows that suprachoroidal, bipolar stimulation can elicit visual responses, and that the area of cortical activation was more focused when using bipolar, biphasic stimulation, and six-return electrodes.
2

Effects of neurostimulation via a suprachoroidal vision prosthesis

Wong, Yan Tat, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2009 (has links)
Microelectronic vision prostheses aim to restore visual percepts through electrical stimulation of the surviving visual pathways in the blind. Electrical stimulation has been shown to produce spots of light in the visual field. A neurostimulator that forms the basis of a vision prosthesis was designed using a high voltage CMOS process to allow it to be able to stimulate when faced with high electrode-tissue impedances. It was implemented with novel features that allow it to be scalable, and to focus charge injection, and can stimulate multiple sites simultaneously using a current source and sink at each site. To reduce electrical cross-talk between multiple stimulation sites, six-return electrodes surround each stimulating electrode, electrically guarding them from each other. The six-return electrode configuration was shown to reduce electrical cross-talk in saline bath tests compared to single-return electrode configurations. The neurostimulator was used to evoke responses from cats through electrical stimulation via intravitreal ball electrodes, corneal electrodes, and planar electrode arrays in the suprachoroidal space. Responses were measured on the visual cortex through optical imaging of intrinsic signals, and through surface electrodes. Using the planar electrode array in the suprachoroidal space, responses were elicited to biphasic, bipolar and monopolar stimuli, with each stimulating electrode coupled with either six-return electrodes, two-return electrodes, or a single-return electrode. The average charge threshold to elicit a response for biphasic, bipolar stimulation with six-return electrodes was 76.47 ?? 8.76 nC (standard error of the mean). For biphasic, bipolar stimulation, the magnitude and area of cortical response with the six-return electrode configurations was on average 2.18 ?? 0.19 times smaller than single-return electrode configurations, and 1.89 ?? 0.19 times smaller than two-return electrode configurations (P < 0.0001). It was also found that for biphasic stimulation, a greater magnitude and area of response was elicited for monopolar stimulation compared to bipolar stimulation. This dissertation details the design and testing of a novel, scalable neurostimulator to focus charge injection. It also shows that suprachoroidal, bipolar stimulation can elicit visual responses, and that the area of cortical activation was more focused when using bipolar, biphasic stimulation, and six-return electrodes.
3

A vision prosthesis neurostimulator: progress towards the realisation of a neural prosthesis for the blind

Dommel, Norbert Brian, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2008 (has links)
Restoring vision to the blind has been an objective of several research teams for a number of years. It is known that spots of light -- phosphenes -- can be elicited by way of electrical stimulation of surviving retinal neurons. Beyond this, however, our understanding of prosthetic vision remains rudimentary. To advance the realisation of a clinically viable prosthesis for the blind, a versatile integrated circuit neurostimulator was designed, manufactured, and verified. The neurostimulator provides electrical stimuli to surviving neurons in the visual pathway, affording blind patients some form of patterned vision; besides other benefits (independence), this limited vision would let patients distinguish between day and night (resetting their circadian rhythm). This thesis presents the development of the neurostimulator, an interdisciplinary work bridging engineering and medicine. Features of the neurostimulator include: high-voltage CMOS transistors in key circuits, to prevent voltage compliance issues due to an unknown or changing combined tissue and electrode/tissue interface impedance; simultaneous stimulation using current sources and sinks, with return electrodes configured to provide maximum charge containment at each stimulation site; stimuli delivered to a two dimensional mosaic of hexagonally packed electrodes, multiplexing current sources and sinks to allow each electrode in the whole mosaic to become a stimulation site; electrode shorting to remove excess charge accumulated during each stimulation phase. Detailed electrical testing and characterisation verified that the neurostimulator performed as specified, and comparable to, or better than, other vision prostheses neurostimulators. In addition, results from several animal experiments verified that the neurostimulator can elicit electrically evoked visual responses. The features of the neurostimulator enable research into how simultaneous electrical stimulation affects the visual neural pathways; those research results could impact other neural prosthetics research and devices.
4

A vision prosthesis neurostimulator: progress towards the realisation of a neural prosthesis for the blind

Dommel, Norbert Brian, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2008 (has links)
Restoring vision to the blind has been an objective of several research teams for a number of years. It is known that spots of light -- phosphenes -- can be elicited by way of electrical stimulation of surviving retinal neurons. Beyond this, however, our understanding of prosthetic vision remains rudimentary. To advance the realisation of a clinically viable prosthesis for the blind, a versatile integrated circuit neurostimulator was designed, manufactured, and verified. The neurostimulator provides electrical stimuli to surviving neurons in the visual pathway, affording blind patients some form of patterned vision; besides other benefits (independence), this limited vision would let patients distinguish between day and night (resetting their circadian rhythm). This thesis presents the development of the neurostimulator, an interdisciplinary work bridging engineering and medicine. Features of the neurostimulator include: high-voltage CMOS transistors in key circuits, to prevent voltage compliance issues due to an unknown or changing combined tissue and electrode/tissue interface impedance; simultaneous stimulation using current sources and sinks, with return electrodes configured to provide maximum charge containment at each stimulation site; stimuli delivered to a two dimensional mosaic of hexagonally packed electrodes, multiplexing current sources and sinks to allow each electrode in the whole mosaic to become a stimulation site; electrode shorting to remove excess charge accumulated during each stimulation phase. Detailed electrical testing and characterisation verified that the neurostimulator performed as specified, and comparable to, or better than, other vision prostheses neurostimulators. In addition, results from several animal experiments verified that the neurostimulator can elicit electrically evoked visual responses. The features of the neurostimulator enable research into how simultaneous electrical stimulation affects the visual neural pathways; those research results could impact other neural prosthetics research and devices.
5

Prosthetic vision : Visual modelling, information theory and neural correlates

Hallum, Luke Edward, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2008 (has links)
Electrical stimulation of the retina affected by photoreceptor loss (e.g., cases of retinitis pigmentosa) elicits the perception of luminous spots (so-called phosphenes) in the visual field. This phenomenon, attributed to the relatively high survival rates of neurons comprising the retina's inner layer, serves as the cornerstone of efforts to provide a microelectronic retinal prosthesis -- a device analogous to the cochlear implant. This thesis concerns phosphenes -- their elicitation and modulation, and, in turn, image analysis for use in a prosthesis. This thesis begins with a comparative review of visual modelling of electrical epiretinal stimulation and analogous acoustic modelling of electrical cochlear stimulation. The latter models involve coloured noise played to normal listeners so as to investigate speech processing and electrode design for use in cochlear implants. Subsequently, four experiments (three psychophysical and one numerical), and two statistical analyses, are presented. Intrinsic signal optical imaging in cerebral cortex is canvassed appendically. The first experiment describes a visual tracking task administered to 20 normal observers afforded simulated prosthetic vision. Fixation, saccade, and smooth pursuit, and the effect of practice, were assessed. Further, an image analysis scheme is demonstrated that, compared to existing approaches, assisted fixation and pursuit (but not saccade) accuracy (35.8% and 6.8%, respectively), and required less phosphene array scanning. Subsequently, (numerical) information-theoretic reasoning is provided for the scheme's superiority. This reasoning was then employed to further optimise the scheme (resulting in a filter comprising overlapping Gaussian kernels), and may be readily extended to arbitrary arrangements of many phosphenes. A face recognition study, wherein stimuli comprised either size- or intensity-modulated phosphenes, is then presented. The study involved unpracticed observers (n=85), and showed no 'size' --versus--'intensity' effect. Overall, a 400-phosphene (100-phosphene) image afforded subjects 89.0% (64.0%) correct recognition (two-interval forced-choice paradigm) when five seconds' scanning was allowed. Performance fell (64.5%) when the 400-phosphene image was stabilised on the retina and presented briefly. Scanning was similar in 400- and 100-phosphene tasks. The final chapter presents the statistical effects of sampling and rendering jitter on the phosphene image. These results may generalise to low-resolution imaging systems involving loosely packed pixels.
6

Prosthetic vision : Visual modelling, information theory and neural correlates

Hallum, Luke Edward, Graduate School of Biomedical Engineering, Faculty of Engineering, UNSW January 2008 (has links)
Electrical stimulation of the retina affected by photoreceptor loss (e.g., cases of retinitis pigmentosa) elicits the perception of luminous spots (so-called phosphenes) in the visual field. This phenomenon, attributed to the relatively high survival rates of neurons comprising the retina's inner layer, serves as the cornerstone of efforts to provide a microelectronic retinal prosthesis -- a device analogous to the cochlear implant. This thesis concerns phosphenes -- their elicitation and modulation, and, in turn, image analysis for use in a prosthesis. This thesis begins with a comparative review of visual modelling of electrical epiretinal stimulation and analogous acoustic modelling of electrical cochlear stimulation. The latter models involve coloured noise played to normal listeners so as to investigate speech processing and electrode design for use in cochlear implants. Subsequently, four experiments (three psychophysical and one numerical), and two statistical analyses, are presented. Intrinsic signal optical imaging in cerebral cortex is canvassed appendically. The first experiment describes a visual tracking task administered to 20 normal observers afforded simulated prosthetic vision. Fixation, saccade, and smooth pursuit, and the effect of practice, were assessed. Further, an image analysis scheme is demonstrated that, compared to existing approaches, assisted fixation and pursuit (but not saccade) accuracy (35.8% and 6.8%, respectively), and required less phosphene array scanning. Subsequently, (numerical) information-theoretic reasoning is provided for the scheme's superiority. This reasoning was then employed to further optimise the scheme (resulting in a filter comprising overlapping Gaussian kernels), and may be readily extended to arbitrary arrangements of many phosphenes. A face recognition study, wherein stimuli comprised either size- or intensity-modulated phosphenes, is then presented. The study involved unpracticed observers (n=85), and showed no 'size' --versus--'intensity' effect. Overall, a 400-phosphene (100-phosphene) image afforded subjects 89.0% (64.0%) correct recognition (two-interval forced-choice paradigm) when five seconds' scanning was allowed. Performance fell (64.5%) when the 400-phosphene image was stabilised on the retina and presented briefly. Scanning was similar in 400- and 100-phosphene tasks. The final chapter presents the statistical effects of sampling and rendering jitter on the phosphene image. These results may generalise to low-resolution imaging systems involving loosely packed pixels.