Estudo do desempenho de sistemas de aterramento frente às descargas atmosféricas em instalações de baixa e média tensão

Sant'Anna, Cezar José [UNESP] 07 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07Bitstream added on 2014-06-13T18:52:40Z : No. of bitstreams: 1 santanna_cj_me_bauru.pdf: 665147 bytes, checksum: 6306cdfa87c4bda06d03c808dedff5fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho possui como linha mestra a apresentação de proposições técnicas para as instalações de baixa e média tensão na incidência de descargas atmosféricas, visando diminuir danos nos equipamentos elétricos dos consumidores. Para a realização dessas proposições foram estudados e analisados diversos casos relacionados ao sistema de aterramento recomendados pelas normas e publicações técnicas. A diretriz metodológica adotada nesta pesquisa incorporou estudos correlatos já consolidados, experimentos e também simulações computacionais. Os resultados obtidos foram analisados levando-se em conta a influência dos sistemas de aterramento e seus componentes, tais como: tipos de eletrodos, solo, tipo de condutor de descida e dispositivos de proteção contra surtos. / The master line of this present study consists of the presentation of technical propositions related to low and medium tension installations in the incidence lightning, aiming to decrease damages on consumer's electrical equipment. For the accomplishment of those propositions, several cases related to the earthing systems recommended standards and publications have been studied and analyzed. The methodological directive adopted in the present research has been incorporated already consolidated correlate studies consolidated, experiments, as well as digital simulations. The results obtained have been analyzed taking into account the influence of the earthing systems and their components, such as: electrodes, soil, descending conductors and protection devices.
2

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Bassi, Welson 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
3

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Bassi, Welson 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.
4

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Welson Bassi 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
5

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Welson Bassi 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.