• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 6
  • 6
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The Optimal Transmission Line Relaying Planning and Analysis with Immune Algorithm

Tsai, Cheng-Ta 24 June 2005 (has links)
The objective of this thesis is to enhance the reliability analysis of Relaying systems and build-up model by Markov theory for taipower transmission lines. The set of combinatory multi-elements can be expressed a transition matrix for any pilot protection analysis. The protective reliability system need for transmission protection is introduced and the block modeling consists of protective relays, communication set and circuit breaker. The block modeling is applied for the analysis of the reliability and availability of protection systems by Markov theory, which can be need to derive the adapative maintance cycle by Markov reliability modeling. The system reliability is analysis related to the interruption of supply power. There many methods to be used for the analysis of system reliability such as state space, network. etc. The Markov modeling is more complicated and difficult, however better time-vary probability functions can be defined, for stochastic modeling, the system reliability at any time axis can be obtained by Markov transition matrix, with the time-vary Markov transition matrix. The customers served by each substation can be affected according to the states of transmission lines healthy. Althouth 80% of system faults occurs in the distribution system, transmission line faults will cause more serious service outage. According to the Kauo-Ping transmission line model in taipower, the optimal protection relay planning is solved by minimizing the overall outage cost of customer service interruption and investment protection relay equipments for transmission power systems with immune algorithm. The objective function and constraints are expressed as antigen, and all feasible solutions are expressed as antibody. The diversity of antibody is then enhanced by proximity of antigen so that the global optimization during the solution process can be obtained. It is found that the power service can be restored effectively with the optimal planning of protection relay by the proposed immune algorithm. Based on the computer simulation of protection relay planning, different protection relaying strategies optimal relay planning and customer loss, can be considered for different to enhance the reliability of protection relay system for loss interruption of customer power outage.
2

Short-circuit current calculations and protective relay coordination for industrial and commercial power systems

Mohammadi, Houshang January 1986 (has links)
No description available.
3

Utilização de relés digitais para mitigação dos riscos envolvendo arco elétrico. / Reduction of the risks involving arc flash using digital relays.

Queiroz, Alan Rômulo Silva 24 November 2011 (has links)
O trabalho tem como objetivo avaliar e propor a utilização de soluções tecnológicas que permitam a redução dos riscos causados por arcos elétricos nas instalações de uma unidade industrial com sistema isolado de geração elétrica. Por ser extremamente danosa à segurança das pessoas que interagem com uma instalação elétrica e por causar danos significativos aos equipamentos e instalações, a energia incidente, proveniente de um arco elétrico, deve ser mensurada em conformidade com as normas existentes e os riscos devem ser controlados e mitigados, de maneira a não comprometer a integridade física das pessoas e das instalações. Dessa forma, o presente trabalho propõe alterações no sistema de proteção e a inserção de dispositivos dedicados à identificação de arcos elétricos no interior de painéis da unidade em questão, contribuindo significativamente para a redução da energia incidente liberada na ocorrência de um arco elétrico. Essa redução da energia incidente é conseguida devido à redução do tempo para eliminação da falta, necessitando, dessa forma, de dispositivos e relés de proteção voltados exclusivamente para a proteção contra arco elétrico. / This dissertation aims to evaluate and propose the use of technological solutions that enable the reduction of risks caused by arc flash on the premises of an industrial unit with insulated system of electricity generation. It may be extremely damaging to the safety of people who interact with electrical installations and could cause significant damage to the equipment and facilities, the incident energy from an arc flash should be measured in accordance with existing standards, their risks must be controlled and attenuated, in order not to compromise the physical integrity of people and facilities. That way, this paper proposes changes into the system of protection and the insertion of devices dedicated to the identification of arc flashes inside panels of the unit concerned, contributing significantly to the reduction of incident energy released in the event of an arc flash. This reduction is obtained by lowering the time for the elimination of absence, requiring, therefore, devices and protective relays devoted exclusively to protect against electric arc.
4

Utilização de relés digitais para mitigação dos riscos envolvendo arco elétrico. / Reduction of the risks involving arc flash using digital relays.

Alan Rômulo Silva Queiroz 24 November 2011 (has links)
O trabalho tem como objetivo avaliar e propor a utilização de soluções tecnológicas que permitam a redução dos riscos causados por arcos elétricos nas instalações de uma unidade industrial com sistema isolado de geração elétrica. Por ser extremamente danosa à segurança das pessoas que interagem com uma instalação elétrica e por causar danos significativos aos equipamentos e instalações, a energia incidente, proveniente de um arco elétrico, deve ser mensurada em conformidade com as normas existentes e os riscos devem ser controlados e mitigados, de maneira a não comprometer a integridade física das pessoas e das instalações. Dessa forma, o presente trabalho propõe alterações no sistema de proteção e a inserção de dispositivos dedicados à identificação de arcos elétricos no interior de painéis da unidade em questão, contribuindo significativamente para a redução da energia incidente liberada na ocorrência de um arco elétrico. Essa redução da energia incidente é conseguida devido à redução do tempo para eliminação da falta, necessitando, dessa forma, de dispositivos e relés de proteção voltados exclusivamente para a proteção contra arco elétrico. / This dissertation aims to evaluate and propose the use of technological solutions that enable the reduction of risks caused by arc flash on the premises of an industrial unit with insulated system of electricity generation. It may be extremely damaging to the safety of people who interact with electrical installations and could cause significant damage to the equipment and facilities, the incident energy from an arc flash should be measured in accordance with existing standards, their risks must be controlled and attenuated, in order not to compromise the physical integrity of people and facilities. That way, this paper proposes changes into the system of protection and the insertion of devices dedicated to the identification of arc flashes inside panels of the unit concerned, contributing significantly to the reduction of incident energy released in the event of an arc flash. This reduction is obtained by lowering the time for the elimination of absence, requiring, therefore, devices and protective relays devoted exclusively to protect against electric arc.
5

Optimering av selektivplaner och dessbetydelse för samhället / Optimization of selective tripping schedule and its importancefor society

Gannholm, Fredrik January 2018 (has links)
Vid ombyggnationer och utbyggnationer av elnät förändras dess karakteristik.Detta leder till att skyddsfunktioner kan behöva justeras för att passa elnätets nyakarakteristik. Justeringar kan medföra att selektiviteten mellan skydden försvinner.Selektivitet innebär att endast skyddet närmast felet bryter strömmen, så atten så liten del som möjligt av elnätet blir strömlöst. För att säkerställa att selektivitetråder mellan skydden utformas selektivplaner där selektiviteten visuellt kananalyseras och vid behov utförs justering av skydden. Rotebro mottagningsstation iSollentuna ägs och drivs av Sollentuna Energi & Miljö (SEOM). Stationen står införombyggnationer och selektivplanerna behöver därför ses över.Då problemställningen är att selektiviteten mellan skydden behöver kontrollerasblir målsättningen att skapa en selektivplan för Rotebro mottagningsstation. Dennabaseras på mottagningsstationens skyddsinställningar och det anslutna elnätetskarakteristik. Arbetet resulterade i att en modell av Rotebro mottagningsstationskapades i programmet PSS Sincal. Från denna genererades selektivplaner somvisar att små justeringar av skydden kan göras. Det utfördes även en generell analyssom visar att selektivplaner har stor betydelse för samhället. / In case of build out and rebuilding electricity grids, the electrical characteristicschange. This means that protection features may need to be adjusted to suit theelectrical grids’ new characteristics. Adjustments may lead to loss of selectivity betweenprotective relays. Selectivity means that only the protection device closest tothe fault break the current, so only the smallest possible part of the electrical gridgets disconnected. To assure selectivity, selective tripping schedule is created andprotective relays are adjusted if needed. Rotebro substation in Sollentuna is ownedand operated by Sollentuna Energi & Miljö (SEOM). The substation is facing rebuildingand its selective tripping schedule needs to be reviewed.Since the problem is that selectivity between the protective relays needs to bechecked the goal is to create a selective tripping schedule for Rotebro substation.This is based on the substation protective settings and the connected electricalgrids characteristics. The thesis resulted in a model of Rotebro substation createdin the computer program PSS Sincal. From this a selective tripping schedule weregenerated that shows that small adjustments of the protective relays can be made.A general analysis was also conducted which shows that a selective tripping scheduleis of great importance to the society.
6

Innovative numerical protection relay design on the basis of sampled measured values for smartgrids / Conception de relais de protection numérique innovants à base d'échantillons horodatés pour les smartgrids

Ghafari, Christophe 16 December 2016 (has links)
Avec le paradigme du réseau intelligent, les ingénieurs de protection ont maintenant à leur disposition une large gamme de nouvelles technologies de communication. Parmi elles, la norme CEI 61850-9-2 a introduit le concept de bus de procédé qui permet l'envoi de valeurs échantillonnées horodatées à un temps absolu depuis les transformateurs de mesure du terrain jusqu’aux relais de protection numériques. Ces derniers peuvent intégrer la fonction d'unité de mesure de phaseur qui peut être utilisé pour échanger des synchrophaseurs entre les fonctions de protection et pour une nouvelle protection anti-îlotage. Les relais de fréquence et de dérivée de fréquence sont, de nos jours, les méthodes anti-îlotage les plus couramment employées, mais leurs performances ne sont pas satisfaisantes. Dans ce contexte, une nouvelle génération de techniques de traitement du signal pour les relais de protection ayant des échantillons horodatées comme signal d'entrée et intégrant la mesure de synchrophaseurs est nécessaire. Cette thèse étudie d'abord l'impact des valeurs échantillonnées sur le traitement du signal. Trois solutions sont ensuite proposées pour calculer les phaseurs, les fréquences et les dérivées de fréquence dans diverses conditions statiques et dynamiques, puis testées par simulation. Enfin, un algorithme de mesure de synchrophaseurs incorporé dans le traitement de signal initial est proposé. Cet algorithme a été testé selon la dernière version de la norme d'unité de mesure de phaseur et les résultats obtenus sont conformes aux exigences de mesure. / With the Smart Grid paradigm, protection engineers now have available to them a large range of new communication technologies. Among them, IEC Standard 61850-9-2 has introduced the process bus concept which permits sending of absolute time-stamped digitized analogue values from the instrument transformers of the field to numerical relays. The latter can incorporate the phasor measurement unit function which can be used for exchanging synchrophasors between protection functions and for new anti-islanding protection. Frequency and rate-of-change-of-frequency relays are, nowadays, the most commonly employed anti-islanding methods but their performance is not satisfactory. In this context, a new generation of signal processing techniques for protection relays having time-stamped digitized analogue values as input signal with synchrophasors measurement capability is required. This thesis first studies the impact of sampled measured values on the signal processing. Three solutions are then proposed to compute phasor, frequency and rate-of-change-of-frequency estimates under various static and dynamic conditions, and tested via simulation. Finally, a synchronized phasor measurement algorithm incorporated into the initial signal processing is proposed. This algorithm has been tested following the latest version of the phasor measurement unit standard and the results obtained comply with the measurement requirements.