Reconhecimento da perda de eficácia de protetor intra-auricular

Bastos, Ramsés da Silva [UNESP] 30 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-30Bitstream added on 2014-06-13T20:53:05Z : No. of bitstreams: 1 bastos_rs_me_bauru.pdf: 1657123 bytes, checksum: 82b2a42a73240813e3ae8798567f18a4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre os agentes nocivos à saúde, considera-se o ruído um dos mais presentes nos ambientes urbanos e sociais, principalmente nos locais de trabalho e nas atividades de lazer. Existem medidas eficazes para o controle do ruído e o Equipamento de Proteção Individual auricular (EPIa) é o mais utilizado na prevenção da Perda Auditiva Induzida por Ruído (PAIR), sendo que, uma vez instalada, a perda auditiva é irreversível. A perda auditiva vem sendo estudada com forte afinco desde o final do século XIX, desde então, diversas áreas do conhecimento têm realizado estudos com o objetivo de diminuir ou extinguir o problema. Observou-se a carência nos produtos de proteção individuais auditivos confortáveis e funcionais, relacionados à durabilidade, face ao comprometimento eficaz do equipamento. O objetivo principal deste estudo foi reconhecer se há perda da eficácia diante ao tempo de uso em Equipamento de Proteção Individual auditivo, intra-auricular, de espuma e da marca 3M, modelo 1110. Foi apurado que os equipamentos sofrem alteração de eficácia conforme o tempo de uso, e que o desgaste do material inicia perda de confiança, principalmente em frequências audíveis de até 100Hz, e a partir de 16 dias para pressão sonora sofrida de 101dB a 20Hz. Para pressão sonora sofrida a partir de 107dB a 20Hz, a perda de confiança para uso, principalmente em frequências audíveis até 100Hz, foi de 8 dias. Os EPIas não perdem eficácias de atenuação importantes com o uso diário em frequências a partir de 1KHz até 20KHz. Conclui-se que há perda de eficácia, conforme o uso diário e frequente do equipamento de Proteção Individual auditivo estudado. Os resultados confirmaram as expectativas, demonstrando que parâmetros de função, em detrimento ao envelhecimento do EPIa, face a seu uso diuturno,... / Among the health harmful agents, it is conferred to the noise, one of the most presents in urban and social environments, mainly in workstations and the laser activities. There are efficient measures to control of the noise and the auricular Individual Protection Equipment is the most used to prevent of the Induced Auditory Loss by Noise, being that, once installed, the hearing loss is irreversible. The hearing loss has been studied with much dedication since the end of century XIX, since then, several areas of the knowledge have accomplished studies with the objective of decreasing or extinguishing problem. It has been observed the scarcity in the comfortable auditory products of individual and functionaries protection, related to durability, face to the efficient right of the equipment. The main objective of this study was recognizing if there is effectiveness loss in presence of the time of use of the Auditory Equipment, intra-auricular Individual Protection, of foam (3M), model 1110. It has been acute that the equipments suffer efficacy alteration according to the time of use, and the material wear initiates reliable loss, mainly in audible frequencies going up to 100Hz, and from 16 days on for sonorous pressure suffered in 101dB 20Hz. For sonorous pressure suffered from 107dB to 20Hz, the reliable loss for the use, mainly in audible frequencies going up to 100Hz, was of 8 days. The EPlas do not lose effectiveness of important attenuation by the daily use in frequencies from 1KHz until 20KHz. It's been concluded that the loss of effectiveness, according to the daily and frequent use of the auditory Protection Equipment was studied. The results have confirmed the expectations, demonstrating that function parameters, in detriment to the aging of the EPla, in the daily presence of its use, they show themselves important in...(Complete abstract, click electronic access below)
2

Conhecimento dos trabalhadores de uma empresa de manutenção industrial em relação à proteção auditiva / Knowledge of workers exposed to noise in relation to hearing protection

Greca, Ana Ligia Melo Martins 14 December 2010 (has links)
Made available in DSpace on 2016-04-27T18:11:48Z (GMT). No. of bitstreams: 1 Ana Ligia Melo Martins Greca.pdf: 460056 bytes, checksum: b44d71bbbac35e1535f5b80186a51c22 (MD5) Previous issue date: 2010-12-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objective. Evaluate the knowledge of workers exposed to noise in relation to hearing protection and identify prevalence and outbreaks of noiseinduced hearing loss over three years. Method. The sample consisted of 65 workers at an engineering company aged 21 to 57 years, all male and exposed to noise at or above 85 dB (A). All workers wore hearing protection. The procedures included the use of the questionnaire "Beliefs and attitudes about hearing protection and hearing loss" and analysis of audiometric tests performed in 2007, 2008 and 2009. Results: Most workers (70.8%) had a time of noise exposure in the company within one to five years. Of the total, 33 workers (50.7%) reported complaints regarding the use of hearing protectors. The most frequent complaints were itching (23.1%) and difficulty in communication (12.3%). Most workers (78.5%) reported working in noisy environment. The prevalence of noise-induced hearing loss ranged from 21.6% to 38.5% during the three years. The onset of hearing loss ranged from 23 to 38.5% in the comparison of tests from 2007 to 2009. The questionnaire answers indicated, in most cases, workers attached importance to the hearing and know the strategies of hearing protection. Conclusion: There was a statistically significant association between age and hearing loss. The questionnaire results indicated that, in general, workers have knowledge about hearing protection, despite the high prevalence rate and triggering noise-induced hearing loss / Objetivo. Avaliar o conhecimento de trabalhadores expostos a ruído em relação à proteção auditiva e identificar prevalências e desencadeamentos de perda auditiva induzida por ruído no decorrer de três anos. Método. A amostra foi composta por 65 trabalhadores de uma empresa de engenharia com idade de 21 a 57 anos, todos do sexo masculino e expostos a ruído igual ou superior a 85 dB(A). Todos os trabalhadores usavam protetores auditivos. Os procedimentos incluíram a aplicação do questionário Crenças e atitudes sobre proteção auditiva e perda auditiva e análise das audiometrias realizadas em 2007, 2008 e 2009. Resultados: A maioria dos trabalhadores (70,8%) tinha tempo de exposição a ruído na empresa no intervalo de um a cinco anos. Do total, 33 trabalhadores (50,7%) relataram queixas em relação ao uso de protetor auditivo. As queixas de maior ocorrência foram coceira (23,1%) e dificuldade de comunicação (12,3%). A maioria dos trabalhadores (78,5%) relatou trabalhar em ambiente ruidoso. A prevalência de perda auditiva induzida pelo ruído variou de 21,6% a 38,5% no decorrer dos três anos. O desencadeamento de perdas auditivas variou de 23 a 38,5% na comparação dos exames de 2007 a 2009. As respostas do questionário indicaram, em sua maioria, que os trabalhadores atribuíam importância à audição e conheciam as estratégias de proteção auditiva. Conclusão: Houve associação estatisticamente significante entre idade e perda auditiva. Os resultados do questionário indicaram que, em geral, os trabalhadores têm conhecimento com relação à proteção auditiva, apesar do elevado índice de prevalência e de desencadeamento de perdas auditivas induzidas por ruído
3

Aplicação de exame de resposta auditiva de estado estável para avaliação da atenuação de protetores auriculares

Queiroz, James Luizar de [UNESP] 18 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-18Bitstream added on 2014-06-13T18:34:56Z : No. of bitstreams: 1 queiroz_jl_me_bauru.pdf: 1056571 bytes, checksum: 740ab85f7a95dbf39493eb3d2218a8b5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta pesquisa foi determinar os níveis de atenuação de Dispositivos de Proteção Auditivos (DPAs), usando um teste chamado Resposta Auditiva de Estado Estável (RAEE). O teste RAEE é um exame eletrofisiológico que usa elétrodos para captar a atividade elétrica do tronco encefálico, sem depender da resposta do indivíduo, eliminando a subjetividade, assim como aspectos ligados à atenção, tempo de resposta, níveis de audição, etc. Neste método foram avaliados dez indivíduos, por meio da RAEE, estimulando-se o sistema de audição, primeiro sem protetor e, subsequentemente, com dois tipos de protetores auditivos, a saber um de inserção intra-auricular outro circunauricular de uso comum no mercado. Os resultados evidenciaram valores inferiores àqueles expressos no Certificado de Aprovação: para o plug, uma diferença de 10,3 dB, e para a concha, 4,3 dB. Na repetição dos testes, encontrou-se uma boa repetitividade, com diferença entre zero e 5 dB para 75% das frequências testadas. / The purpose of this research was to determine the levels of attenuation of Hearing Protection Devices (HPDs) using a test called Auditory Steady-State Response (ASSR). The ASSR test is an electrophysiological examination that uses electrodes to capture the electrical activity of the auditory nerve and the brainstem without depending on the individual's response, thus eliminating the subjectivity of personal factors such as attention, response time, hearing ability, etc. This paper presents the results of a ten test which evaluated the hearing threshold of individuals, by first stimulating the hearing system without a protector and subsequently with a hearing protector. The results of this study were lower than those expressed in the Certificate of Approval: to plug a gap of 10.3 dB and dB the ear mufflers. The repetition of tests found a good repeatability with a difference between zero and 5 dB for 75% of the frequencies tested.