• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 16
  • 6
  • 3
  • 2
  • 2
  • Tagged with
  • 62
  • 62
  • 62
  • 62
  • 62
  • 20
  • 16
  • 15
  • 13
  • 12
  • 10
  • 10
  • 9
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Détermination des mécanismes de dégradation d'électrodes modèles de pile à combustible à membrane échangeuse de protons / Structure effect of carbon-supported Pt nanoparticles on PEMFC reaction kinetics

Zhao, Zuzhen 07 December 2012 (has links)
Ce travail de thèse s’est intéressé aux mécanismes de dégradation de nanoparticules de Pt supportées sur carbone utilisées pour catalyser les réactions électrochimiques dans une pile à combustible à membrane échangeuse de protons (PEMFC) et à leur conséquences d’un point de vue cinétique. Nous avons mis en évidence les différents mécanismes (maturation d’Ostwald 3D, corrosion du support carboné, migration/agrégation des cristallites métalliques) conduisant à une perte de surface active électrochimiquement et avons trouvé des conditions permettent d’isoler chacun de ces mécanismes. En premier lieu, nous avons montré que les nanoparticules de Pt supportées sur carbone ne sont pas immobiles mais agrègent en conditions réactionnelles notamment en présence de molécules réductrices. La vitesse de ce processus varie dans l'ordre CO > CH3OH > H2 et a été reliée à (i) la baisse du travail d’adhésion engendrée par la chimisorption de ces molécules et (ii) la réduction des groupements oxygénés présents sur le support carboné natif.Nous nous sommes également intéressés au mécanisme d’électrooxydation électrochimique du Vulcan XC72, un noir de carbone classiquement utilisé dans les couches catalytiques de PEMFC. Des mesures par spectroscopie Raman ont montré que les domaines désordonnés du Vulcan XC72 (non-graphitiques, hybridation sp3) sont corrodés de façon préférentielle dans des conditions expérimentales proches de celles d’une cathode de PEMFC. Les domaines ordonnés du support carboné (carbone graphitique, hybridation sp2) sont également corrodés, la vitesse de ce processus étant largement inférieure à ce qui est observé sur les domaines désordonnés. En conséquence, les nanoparticules de Pt se détachent ou agglomèrent comme le révèlent des expériences de microscopie électronique en transmission couplées à l’électrochimie. L’ensemble de ces mécanismes de dégradation conduit à un abaissement de la densité du nombre de particules métalliques et augmente la distance entre ces dernières. Dans le chapitre IV, nous montrons que des électrocatalyseurs Pt/Sibunit electrocatalysts possédant (i) un faible chargement massique en Pt, et (ii) de grandes distances inter-particules présentant une faible activité pour la réduction du dioxygène de l’air. Le nombre moyen d’électrons transférés par molécule de dioxygène décroît bien sous la valeur théorique de 4 lorsque l’épaisseur de la couche catalytique ou le chargement massique diminue. Nous avons relié cela à un transport et à une ré-adsorption plus difficiles des intermédiaires réactionnels notamment le péroxyde d’hydrogène. Une diminution du nombre de sites catalytiques peut également engendrer une limitation des cinétiques réactionnelles par l’adsorption de l’oxygène. Au vu de l’ensemble des résultats précédents, nous avons conclu que des cristallites de plus grande taille permettraient d’améliorer la durabilité des matériaux contenus dans les couches catalytiques de PEMFC. Des nano-fils de Pt (NWs) avec une taille moyenne de cristallite de 2,1 ± 0,2 nm ont été synthétisés. Nous avons montré que la morphologie du matériau joue un rôle conséquent à la fois en termes d’activité électrocatalytique et de durabilité : les matériaux Pt NWs/C permettent une réduction de prêt de 170 mV de la surtension d’oxydation d’une monocouche de monoxyde de carbone et possèdent une activité catalytique élevée et stable pour l’électrooxydation du méthanol. Cette dernière a été attribuée à (i) l’augmentation de la masse des cristallites de Pt résultant de l’augmentation en taille (nanoparticules à nano-fils) et (ii) une surface de contact élevée avec le support carboné. Ces matériaux possèdent un potentiel intéressant pour résoudre les problèmes de durabilité rencontrés avec les matériaux 0D utilisés de façon conventionnelle. / State-of-the-art catalytic layers of proton-exchange membrane fuel cells (PEMFCs) utilize ionomer-bonded Pt-based nanocrystallites supported on a high surface area carbon support to accelerate the rate of the hydrogen oxidation reaction at the anode, and of the oxygen reduction reaction at the cathode. Post-mortem analysis of PEMFC catalytic layers reveal that four degradation mechanisms yield Pt surface area losses (and hence decreased PEMFC performance): (i) aggregation and/or detachment of the metal nanoparticles, (ii) corrosion of the carbon support, (iii) Ostwald ripening (dissolution/redeposition of the Pt-based crystallites) yielding the formation of ionic species and (iv) chemical reduction of the Ptz+ species in ion conductors, yielding the formation of electrically disconnected Pt crystallites. A major concern of the Ph.D. was to be able to isolate the migration of the Pt nanocrystallites. For that purpose, commercial Pt/Vulcan XC 72 electrocatalysts were aged in “mild” conditions, for which the corrosion of both the Pt nanoparticles and the carbon support could not be considered dominant. Evidences were provided that the Pt/C nanoparticles are not immobile but prone to agglomerate in the presence of H2, CH3OH, and CO, three molecules of interest for PEMFCs. The migration rate of the Pt crystallites was the largest in CO-containing solution and decreased in the order CO > CH3OH > H2. We postulate that the morphological changes of the Pt/C nanoparticles may be caused by (i) a change of the work of adhesion between the metal phase and the carbon support or (ii) the reduction of the oxygen-bearing surface groups strongly interacting with the Pt nanocrystallites. We also investigated the mechanism of the electrochemical oxidation of Vulcan XC72, a carbon black conventionally used in PEMFCs. Raman spectroscopy measurements evidenced that the disordered domains of the Vulcan XC72 support (non-graphitic, sp3-hybridized) are preferentially oxidized. The ordered domains (graphitic carbon, sp2-hybridized) of the Vulcan XC72 support are also oxidized but at a much smaller rate than that observed on the non-graphitic domains. A major consequence of the oxidation of the high-surface area carbon support is the aggregation and the detachment of the supported Pt nanoparticles. In Chapter V, we used model Pt/Sibunit electrocatalysts to show that aged catalytic layers with (i) low Pt to C weight fraction, (ii) large inter-particle distance, feature bad performance for the oxygen reduction reaction (ORR). The average number of transferred electrons produced during the ORR decreases below 4 with the decrease of the catalyst layer thickness or the Pt loading. This was rationalized by considering the lower probability for H2O2 molecules (the major reaction intermediate) to be re-adsorbed and further reduced into water in the catalytic layer when the inter-particle distance decreases. Finally, Pt nanowires (NWs) with 2.1 ± 0.2 nm crystallite size were synthesized by a soft template method. Evidences were provided that the morphology of the Pt material plays a pivotal role both in terms of electrocatalytic activity/stability: the 1D Pt NWs/C demonstrate a reduction by ca. 170 mV of the CO oxidation overpotential and feature high and stable MOR activity with respect to a conventional Pt/C 20 wt. % catalyst. The enhanced durability of Pt NWs/C was rationalized by considering (i) the increase in weight of the Pt nanomaterials resulting from the increase in size (from nanoparticles to nanowires) and (ii) the enhanced contact surface area between the Pt NWs and the carbon support. The development of 1D Pt nanostructures, such as Pt NWs, hold promises to solve the durability issues faced with the 0D materials currently used in PEMFCs.Keywords: proton exchange membrane fuel cell, durability of PEMFC materials, electrochemical carbon oxidation, crystallite migration, Pt nanowires.
52

Corrosion of high surface area carbon supports used in proton-exchange membrane fuel cell electrodes / Corrosion des supports carbonés des électrocatalyseurs de pile à combustible basse température

Castanheira, Luis Filipe Rodrigues 14 November 2014 (has links)
Cette thèse est consacrée à l’étude des mécanismes de dégradation de noirs de carbone de forte surface spécifique (HSAC) utilisés comme supports d’électrocatalyseurs dans une pile à combustible à membrane échangeuse de protons (PEMFC). Nous avons montré que le mécanisme et les cinétiques de la corrosion électrochimique du carbone (COR) sont influencés par la présence d’ionomère Nafion®, la limite supérieure de potentiel électrochimique, la nature et le nombre de caractérisations intermédiaires présentes dans des tests de dégradation accélérés. En utilisant la spectroscopie Raman,il apparaît que la COR est sensible à la structure cristallographique des HSAC et procède plus rapidement sur les domaines désordonnés (carbone amorphe, cristallites de graphite présentant des défauts). Le taux de recouvrement en espèces oxygénées évalué par spectroscopie de photoélectrons X a été comparé à celui trouvé en intégrant l’intensité du pic quinone/hydroquinone (Q/HQ) envol tampérométrie cyclique. Finalement, une comparaison avec des matériaux carbonés ayant fonctionné pendant 12860 heures en PEMFC confirme nos principaux résultats et permet d’élaborer des stratégies pour atténuer les conséquences de la COR. / This thesis investigates the degradation mechanism of high surfacearea carbon (HSAC) supports used in proton-exchange membrane fuel cell (PEMFC) electrodes. The structural and the chemical properties of different HSAC supports were established. The effectof the Nafion® ionomer used as a proton conductor, the gas atmosphere, the upper potential limit and the intermediate electrochemical characterizations used to monitor the changes ofthe electrochemical surface area during accelerated stress tests(ASTs) were investigated. The long-term physical and chemical changes of Pt/HSAC electrocatalysts were investigated insimulated PEMFC operating conditions. Using Raman spectroscopy, we showed that the COR is strongly structure sensitive and proceeds more rapidly on disordered domains of the HSAC (amorphous carbon and defective graphite crystallites) thanon graphitic domains. The coverage with carbon surface oxides was investigated with X-ray photoelectron spectroscopy and bridged tothe intensity of the quinone/hydroquinone (Q/HQ) peak monitored by cyclic voltammetry. Finally, the analyses realized on membrane electrode assemblies operated for 12,860h disclosed a perfect agreement between model and real PEMFC operating conditions, and confirmed the structural dependency of the COR kinetics.
53

Etude de l'influence des protons sur la réduction de l'oxygène dans des couches catalytiques ordonnées en vue d'une application en pile à combustible / Study of the influence of protons on the oxygen reduction in ordered catalytic layers for fuel cell applications

Rouhet, Marlene 16 September 2014 (has links)
Les couches catalytiques avec une structure ordonnée à base de nanoparticules de Pt supportées sur des nanofilaments de carbone verticalement alignés ont montré des performances intéressantes grâce à l’amélioration des propriétés du transport de matière et à une meilleure utilisation du Pt. Des études électrochimiques combinées à une modélisation mathématique ont mis en évidence l’influence du transport de protons sur les processus d’oxydo-réduction, la cinétique et le mécanisme de réduction de l’O2 (ORR), et sur H2O2 qui s’échappe des couches pendant l’ORR. Nous avons montré que (i) les protons sont impliqués dans l’étape limitante de la réaction, (ii) pour un pH ≥ 3, un plateau de courant limité par la diffusion des protons est observé et, (iii) pour un pH ≥ 3, le mécanisme de l’ORR implique non seulement les ions hydroniums mais aussi les molécules d’eau. L’intégration de ces couches catalytiques dans des PEMFCs haute température a ensuite été étudiée. Les performances obtenues sont légèrement plus basses que celles des couches conventionnelles. Un travail d’optimisation reste donc à accomplir pour améliorer les performances. / Ordered catalytic layers based on vertically aligned carbon nanofilaments with Pt nanoparticles demonstrate high efficiency for oxygen transport and Pt utilization in the catalytic layer. Electrochemical studies combined with mathematical modeling confirm the influence of the proton transport on surface red-ox processes, the kinetics and the mechanism of the O2 reduction (ORR), and on the H2O2 escape. We show that (i) protons are involved in the rate-determining step of the O2 reduction, (ii) for pH ≥ 3, a plateau corresponding to the diffusion-limited current of protons is observed and, (iii) for pH ≥ 3, the mechanism of the ORR involves not only the hydronium ions but also water molecules. The integration of these catalytic layers in high temperature PEMFCs was then studied. The performance is slightly lower than that for conventional layers. An optimization work is required to improve the performance.
54

Comportement local et performances électriques d'une pile à combustible à membrane : vers un outil de diagnostic / Proton exchange membrane fuel cell local behavior and electric performances : basis to a diagnosis tool

Chupin, Sylvain 11 December 2009 (has links)
Le travail de thèse présenté ici apporte des éléments de compréhension sur l'influence de la gestion de l'eau et de la gestion thermique d'une PEMFC sur ses performances électriques. Un modèle bidimensionnel représentant les transferts de matière et de chaleur dans l'épaisseur d'une cellule élémentaire et le long des canaux d'alimentation est mis en place. Une partie spécifique de l'étude concerne la modélisation microscopique des agglomérats réactionnels et l'influence de l'eau présente dans ces zones actives sur les performances électriques locales et globales de la pile. Dans l'optique de réaliser un modèle pouvant s'intégrer à un système de contrôle, les transports couplés de l'eau liquide et vapeur, de la chaleur et des charges sont résolus analytiquement. Quelles que soient les conditions de fonctionnement, le modèle permet de calculer quel est l'état interne de la pile en terme d'hydratation, de production de courant et de chaleur. Le diagnostic de l'état interne de la pile en fonction des conditions opératoires permet de connaître précisément comment adapter les paramètres d'alimentation de la pile pour obtenir des performances électriques optimales. Les distributions locales d'eau, de courant et de température sont présentées en fonction de la stratégie d'alimentation en gaz de la pile et de l'orientation du circuit de régulation thermique. Une partie consacrée au diagnostic de fonctionnement d'une pile illustre en quoi l'utilisation du modèle et la connaissance de l'état interne de la pile apporte des informations primordiales lors de l'utilisation d'une pile à combustible / The present work contributes to the understanding of water management and thermal management of a PEM fuel cell influences on the electrical performances. A bidimensional model representing mass and heat transfer in the cell thickness and along distribution channels is done. A specific part of the study concerns a microscopic representation of reactive agglomerates. This part presents the impact of the liquid water presence on local and global current densities. In te vein of integrating this model in a total fuel cell control system, simplifications have been done and coupled mass, heat and charge transfers are solved analytically. For any operating condition, the model gives a complete view of the hydric, thermal and electric inner situation of the cell. This diagnosis of the inner state of the cell leads to find the operating conditions giving to the optimal electric performances. Water, current and temperature distributions are presenting for different gas feeding strategies and different thermal management configurations. A specific part is dedicated to illustrate how this local diagnosis of the cell state can be used to estimate its global electric performances
55

Study of catalysts with high stability for proton exchange membrane fuel cells

Yang, Fan 08 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The innovation and investigation of catalysts in proton exchange membrane fuel cells are included in this thesis. In the first part of this work, stability of the catalyst support of PEMFC catalyst is investigated. Nanoscale platinum particles were loaded on two different kinds of carbon supports, nano graphene sheets and functionalized carbon black/graphene hybrid were developed by the liquid phase reaction. The crystal structure of two kinds of catalysts was characterized by X-ray diffractometer (XRD). The morphology and particle size were characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Pt loading was measured by thermal gravimetric analysis (TGA). The Brunauer, Emmett and Teller (BET) method was applied to test the surface area of the catalysts. The electrochemical surface area (ECSA) and mass activity during oxygen reduction reaction (ORR) process for two kinds of catalyst were tested by cyclic voltammetry method under different conditions. The stability of the catalysts were tested by accelerated durability test (ADT). The results show that although the mass activity of Pt/graphene is much lower, the stability of it is much better than that of the commercial catalyst. After adding functionalized carbon black (FCB) as spacer, the stability of the catalyst is preserved and at the meantime, the mass activity becomes higher than 20% Pt/XC72 catalyst. The lower mass activity of both catalysts are due to the limitation of the electrolyte diffusion into the carbon support because of the aggregation nature of graphene nano-sheets. After introducing functional carbon black as spacer, the mass activity and ECSA increased dramatically which proved that FCB can be applied to prevent the restacking of graphene and hence solved the diffusion problem. In the meantime, the durability was still keeping the same as Pt/graphene catalyst. In the second part of the work, the restacking problem was solved by introducing FCB as spacers between functionalized graphene nanosheets. The same measurement was applied to test the electrochemical performance of Pt/FCB/FG catalyst. The new catalyst showed a higher mass activity compared to Pt/graphene catalyst which meant the restacking problem was partially solved. The durability of the Pt/FCB/FG catalyst was still excellent.
56

Kinetic Studies and Electrochemical Processes at Fuel Cell Electrodes

Stuckey, Philip A. January 2011 (has links)
No description available.
57

Experimental Studies on the Mechanical Durability of Proton Exchange Membranes

Li, Yongqiang 28 December 2008 (has links)
Three testing methods are proposed to characterize properties of fuel cell materials that affect the mechanical durability of proton exchange membranes (PEMs). The first two methods involved measuring the in-plane biaxial strength of PEMs and the biaxial hygrothermal stresses that occur in PEMs during hygrothermal cycles. The third method investigated the nonuniform thickness and compressibility of gas diffusion media which can lead to concentrated compressive stresses in the PEM in the through-plane direction. Fatigue and creep to leak tests using multi-cell pressure-loaded blister fixtures were conducted to obtain the lifetimes of PEMs before reaching a threshold value of gas leakage. These tests are believed to be more relevant than quasi-static uniaxial tensile to rupture tests because of the introduction of biaxial cyclic and sustained loading and the use of gas leakage as the failure criterion. They also have advantages over relative humidity cycling test because of the controllable mechanical loading. Nafion® NRE-211 membrane was tested at three different temperatures and the time-temperature superposition principle was used to construct a stress-lifetime master curve. Tested at 90°C, extruded Ion Power® N111-IP membrane was found to have longer lifetime than Gore™-Select® 57 and Nafion NRE-211 membranes under the same blister pressure profiles. Bimaterial specimens fabricated by bonding a piece of PEM to a substrate material were used to measure the hygral stresses, compressive and tensile, in the PEM during relative humidity cycles. The substrate material and its thickness were carefully chosen so that stresses in the PEM could be obtained directly from the curvature of the bimaterial specimen without knowing the constitutive properties of the PEM. Three commercial PEMs were tested at 80°C by cycling the relative humidity between 90% and 0% and by drying the membrane to 0%RH after submersion in liquid water. Stress histories for all three membranes show strong time-dependencies and Nafion® NRE-211 exhibited the largest tensile stress upon drying. Besides in-plane stresses, hard spots in gas diffusion media (GDM) can locally overcompress PEMs in the out-of-plane direction and cause electrical shorting. In this study, GDM samples sealed with an impermeable Kapton® film on the surface were compressed with uniform air pressure and the nonuniform displacement field was measured with a three-dimensional digital image correlation technique. Hard spots as a result of the nonuniform thickness and compressibility of the GDM were found and their severities as stress risers are evident. Locally, a nominal platen compression (similar to bipolar plate land compression) of 0.68 MPa can lead to compressive stress as large as 2.30 MPa in various hard spots that are in the order of 100s µm to 1 mm in size. / Ph. D.
58

Contribution au pronostic de durée de vie des systèmes piles à combustible PEMFC / Contribution to lifetime prognostics for proton exchange membrane fuel cell (PEMFC) systems

Silva Sanchez, Rosa Elvira 21 May 2015 (has links)
Les travaux de cette thèse visent à apporter des éléments de solutions au problème de la durée de vie des systèmes pile à combustible (FCS – Fuel Cell System) de type à « membrane échangeuse de protons » (PEM – Proton Exchange Membrane) et se décline sur deux champs disciplinaires complémentaires :Une première approche vise à augmenter la durée de vie de celle-ci par la conception et la mise en œuvre d'une architecture de pronostic et de gestion de l'état de santé (PHM – Prognostics & Health Management). Les PEM-FCS, de par leur technologie, sont par essence des systèmes multi-physiques (électriques, fluidiques, électrochimiques, thermiques, mécaniques, etc.) et multi-échelles (de temps et d'espace) dont les comportements sont difficilement appréhendables. La nature non linéaire des phénomènes, le caractère réversible ou non des dégradations, et les interactions entre composants rendent effectivement difficile une étape de modélisation des défaillances. De plus, le manque d'homogénéité (actuel) dans le processus de fabrication rend difficile la caractérisation statistique de leur comportement. Le déploiement d'une solution PHM permettrait en effet d'anticiper et d'éviter les défaillances, d'évaluer l'état de santé, d'estimer le temps de vie résiduel du système, et finalement, d'envisager des actions de maîtrise (contrôle et/ou maintenance) pour assurer la continuité de fonctionnement. Une deuxième approche propose d'avoir recours à une hybridation passive de la PEMFC avec des super-condensateurs (UC – Ultra Capacitor) de façon à faire fonctionner la pile au plus proche de ses conditions opératoires optimales et ainsi, à minimiser l'impact du vieillissement. Les UCs apparaissent comme une source complémentaire à la PEMFC en raison de leur forte densité de puissance, de leur capacité de charge/décharge rapide, de leur réversibilité et de leur grande durée de vie. Si l'on prend l'exemple des véhicules à pile à combustible, l'association entre une PEMFC et des UCs peut être réalisée en utilisant un système hybride de type actif ou passif. Le comportement global du système dépend à la fois du choix de l'architecture et du positionnement de ces éléments en lien avec la charge électrique. Aujourd'hui, les recherches dans ce domaine se focalisent essentiellement sur la gestion d'énergie entre les sources et stockeurs embarqués ; et sur la définition et l'optimisation d'une interface électronique de puissance destinée à conditionner le flux d'énergie entre eux. Cependant, la présence de convertisseurs statiques augmente les sources de défaillances et pannes (défaillance des interrupteurs du convertisseur statique lui-même, impact des oscillations de courant haute fréquence sur le vieillissement de la pile), et augmente également les pertes énergétiques du système complet (même si le rendement du convertisseur statique est élevé, il dégrade néanmoins le bilan global). / This thesis work aims to provide solutions for the limited lifetime of Proton Exchange Membrane Fuel Cell Systems (PEM-FCS) based on two complementary disciplines:A first approach consists in increasing the lifetime of the PEM-FCS by designing and implementing a Prognostics & Health Management (PHM) architecture. The PEM-FCS are essentially multi-physical systems (electrical, fluid, electrochemical, thermal, mechanical, etc.) and multi-scale (time and space), thus its behaviors are hardly understandable. The nonlinear nature of phenomena, the reversibility or not of degradations and the interactions between components makes it quite difficult to have a failure modeling stage. Moreover, the lack of homogeneity (actual) in the manufacturing process makes it difficult for statistical characterization of their behavior. The deployment of a PHM solution would indeed anticipate and avoid failures, assess the state of health, estimate the Remaining Useful Lifetime (RUL) of the system and finally consider control actions (control and/or maintenance) to ensure operation continuity.A second approach proposes to use a passive hybridization of the PEMFC with Ultra Capacitors (UC) to operate the fuel cell closer to its optimum operating conditions and thereby minimize the impact of aging. The UC appear as an additional source to the PEMFC due to their high power density, their capacity to charge/discharge rapidly, their reversibility and their long life. If we take the example of fuel cell hybrid electrical vehicles, the association between a PEMFC and UC can be performed using a hybrid of active or passive type system. The overall behavior of the system depends on both, the choice of the architecture and the positioning of these elements in connection with the electric charge. Today, research in this area focuses mainly on energy management between the sources and embedded storage and the definition and optimization of a power electronic interface designated to adjust the flow of energy between them. However, the presence of power converters increases the source of faults and failures (failure of the switches of the power converter and the impact of high frequency current oscillations on the aging of the PEMFC), and also increases the energy losses of the entire system (even if the performance of the power converter is high, it nevertheless degrades the overall system).
59

Diagnostic et Pronostic de Systèmes Dynamiques Incertains dans un contexte Bond Graph / Diagnostics and Prognostics of Uncertain Dynamical Systems in a Bond Graph Framework

Jha, Mayank Shekhar 08 December 2015 (has links)
Cette thèse développe des approches pour le diagnostic et le pronostic de systèmes dynamiques incertains en utilisant la technique de modélisation Bond Graph (BG). Tout d'abord, une représentation par intervalles des incertitudes paramétriques et de mesures est intégrée à un modèle BG-LFT (Linear Fractional Transformation). Une méthode de détection robuste de défaut est développée en utilisant les règles de l'arithmétique d'intervalle pour la génération de seuils robustes et adaptatifs sur les résidus nominaux. La méthode est validée en temps réel sur un système de générateur de vapeur.Deuxièmement, une nouvelle méthodologie de pronostic hybride est développée en utilisant les Relations de Redondance Analytique déduites d'un modèle BG et les Filtres Particulaires. Une estimation de l'état courant du paramètre candidat pour le pronostic est obtenue en termes probabilistes. La prédiction de la durée de vie résiduelle est atteinte en termes probabilistes. Les incertitudes associées aux mesures bruitées, les conditions environnementales, etc. sont gérées efficacement. La méthode est validée en temps réel sur un système mécatronique incertain.Enfin, la méthodologie de pronostic développée est mise en œuvre et validée pour le suivi efficace de la santé d'un sous-système électrochimique d’une pile à combustible à membrane échangeuse de protons (PEMFC) industrielle à l’aide de données de dégradation réelles. / This thesis develops the approaches for diagnostics and prognostics of uncertain dynamic systems in Bond Graph (BG) modeling framework. Firstly, properties of Interval Arithmetic (IA) and BG in Linear Fractional Transformation, are integrated for representation of parametric and measurement uncertainties on an uncertain BG model. Robust fault detection methodology is developed by utilizing the rules of IA for the generation of adaptive interval valued thresholds over the nominal residuals. The method is validated in real time on an uncertain and highly complex steam generator system.Secondly, a novel hybrid prognostic methodology is developed using BG derived Analytical Redundancy Relationships and Particle Filtering algorithms. Estimations of the current state of health of a system parameter and the associated hidden parameters are achieved in probabilistic terms. Prediction of the Remaining Useful Life (RUL) of the system parameter is also achieved in probabilistic terms. The associated uncertainties arising out of noisy measurements, environmental conditions etc. are effectively managed to produce a reliable prediction of RUL with suitable confidence bounds. The method is validated in real time on an uncertain mechatronic system.Thirdly, the prognostic methodology is validated and implemented on the electrical electro-chemical subsystem of an industrial Proton Exchange Membrane Fuel Cell. A BG of the latter is utilized which is suited for diagnostics and prognostics. The hybrid prognostic methodology is validated, involving real degradation data sets.
60

Electrocatalyseurs à base d’oxydes métalliques poreux pour pile à combustible à membrane échangeuse de protons / Porous metal oxide-based electrocatalysts for proton exchange membrane fuel cells

Cognard, Gwenn 28 March 2017 (has links)
Les électrocatalyseurs conventionnels utilisés dans les piles à combustibles à membrane échangeuse de protons (PEMFC) sont composés de nanoparticules de platine supportées sur des noirs de carbone de forte surface spécifique. A la cathode de la PEMFC, siège de la réaction de réduction de l’oxygène (ORR), le potentiel électrochimique peut atteindre des valeurs élevées - notamment lors de phases arrêt-démarrage - engendrant des dégradations irréversibles du support carboné. Une solution « matériaux » consiste à remplacer ce dernier par des supports à base d’oxydes métalliques. Ceux-ci doivent être résistants à la corrosion électrochimique, conducteurs électroniques et posséder une structure poreuse et nano-architecturée (permettant le transport des réactifs et produits et une distribution homogène de l’ionomère et des nanoparticules de platine). Dans ce travail, nous avons donc élaboré et caractérisé des électrocatalyseurs à base de nanoparticules de platine (Pt) déposées sur du dioxyde d’étain (SnO₂) et de titane (TiO₂) texturés (morphologies aérogel, nanofibres ou « loosetubes ») et conducteurs électroniques (dopés au niobium Nb ou à l’antimoine Sb). Le support permettant d’atteindre les meilleures propriétés électrocatalytiques est un aérogel de SnO₂ dopé à l’antimoine, noté ATO. En particulier, l’électrocatalyseur Pt/ATO présente une activité spécifique vis-à-vis de l’ORR supérieure à celle d’un électrocatalyseur Pt/carbone Vulcan® synthétisé dans les mêmes conditions, suggérant des interactions bénéfiques entre les nanoparticules de Pt et le support oxyde métallique (Strong Metal Support Interactions, SMSI).Des tests de durabilité simulant le fonctionnement d’une PEMFC en conditions automobile ont été effectués en électrolyte liquide à 80 °C sur ces deux électrocatalyseurs : cyclage entre 0,60 et 1,00 V vs l’électrode réversible à hydrogène (RHE) ou entre 1,00 et 1,50 V vs RHE. Le catalyseur Pt/ATO présente une durabilité accrue par rapport au catalyseur Pt/carbone Vulcan® de référence. Cependant, de nouveaux mécanismes de dégradation ont été mis en évidence dans cette étude : tout d’abord, l’élément dopant Sb est progressivement dissout au cours du vieillissement électrochimique, ce qui implique une perte de conductivité électronique. Cette perte est en partie liée à des incursions à bas potentiel, notamment durant les caractérisations électrochimiques. De plus, entre 5 000 et 10 000 cycles de vieillissement électrochimique (entre 0,60 et 1,00 V vs RHE ou entre 1,00 et 1,50 V vs RHE à 57 °C), le matériau support perd sa structure poreuse et forme un film amorphe peu conducteur. / Conventional electrocatalysts used in proton exchange membrane fuel cells (PEMFC) are composed of platinum nanoparticles supported on high specific surface area carbon blacks. At the cathode side of the PEMFC, where the oxygen reduction reaction (ORR) occurs, the electrochemical potential can reach high values - especially during startup-shutdown operating conditions - resulting in irreversible degradation of the carbon support. A “material” solution consists of replacing the carbon with supports based on metal oxides. The latter have to be resistant to electrochemical corrosion, be electronic conductor and have a porous and nano-architectural structure (for the transport of reagents and products and the homogeneous distribution of the ionomer and platinum nanoparticles).In this work, we have developed and characterized electrocatalysts composed of platinum (Pt) nanoparticles based on tin dioxide (SnO2) and titanium dioxide (TiO2) with optimized textural (aerogel, nanofibres or loosetubes morphologies) and electron-conduction properties (doped with niobium Nb or antimony Sb). The best electrocatalytic properties are reached for an antimony-doped SnO2 aerogel support, denoted ATO. The Pt/ATO electrocatalyst has especially a higher specific activity for the ORR than a Pt/carbon Vulcan® electrocatalyst, synthesized in the same conditions, suggesting beneficial interactions between the Pt nanoparticles and the metal oxide support (Strong Metal Support Interactions SMSI).Durability tests simulating automotive operating conditions of a PEMFC were carried out in liquid electrolyte at 57 °C on these two electrocatalysts by cycling between 0.60 and 1.00 V vs the reversible hydrogen electrode (RHE) or between 1.00 and 1.50 V vs RHE. The Pt/ATO electrocatalyst has an increased stability compared to the reference Pt/carbon Vulcan® electrocatalyst. However, new degradation mechanisms were highlighted in this study: first, the doping element (Sb) is progressively dissolved during electrochemical ageing, which implies a loss of electronic conductivity. This loss is partly due to incursions at low potential, including during electrochemical characterizations. Moreover, between 5,000 and 10,000 cycles of the accelerated stress tests (between 0.60 and 1.00 V vs RHE or between 1.00 and 1.50 V vs RHE at 57 °C), the support loses its porous structure and forms a poorly conductive amorphous film.

Page generated in 0.1025 seconds