1

Conception d'un formalisme de pouvoir d'arrêt équivalent et accélération graphique : des simulations Monte Carlo plus efficaces en protonthérapie

Maneval, Daniel 27 April 2019 (has links)
En radiothérapie, la planification de traitement correspond à l’optimisation de la balistique pour administrer la dose prescrite aux lésions à traiter, tout en minimisant les doses collatérales reçues par les tissus sains. L’algorithme de calcul de dose qui est au cœur de cette simulation numérique se doit d’être précis et efficace. L’antagonisme de ces deux compétences a abouti au développement d’algorithmes analytique rapides dont l’amélioration de la précision dosimétrique a, de nos jours, atteint sa limite. L’exactitude de l’algorithme de calcul de dose est particulièrement importante en protonthérapie pour exploiter pleinement le potentiel balistique des protons. La méthode Monte Carlo de transport de proton est la plus précise mais également la moins efficace. Cette thèse a pour sujet le développement d’une plateforme Monte Carlo de calcul de dose suffisamment efficace pour envisager son utilisation en routine clinique. L’objectif principal du projet est d’accélérer le transport Monte Carlo de protons sans compromettre la précision des dépôts de dose. Pour ce faire, deux voies de recherche ont été exploitées. La première a consisté à établir une nouvelle méthode de réduction de variance nommée formalisme du pouvoir d’arrêt restreint équivalent (formalisme Leq). Cette technique améliore significativement la complexité algorithmique temporelle rendue constante (O(1)) au lieu de linéaire (O(n)) des algorithmes Monte Carlo actuels. La seconde voie de recherche s’est attardée à l’utilisation des processeurs graphiques pour améliorer la vitesse d’exécution du transport Monte Carlo de protons. La plateforme développée, nommée pGPUMCD, réalise le transport des protons sur des processeurs graphiques au sein de géométries voxelisées. Dans pGPUMCD, les techniques d’interactions condensées et ponctuelles sont considérées. Les interactions inélastiques de faibles portées sont modélisées par la décélération continue du proton à l’aide du formalisme Leq, et les interactions élastiques par la diffusion coulombienne multiple. Les interactions ponctuelles modélisées sont les interactions inélastiques, les intéractions nucléaires élastiques et non-élastiques proton-noyaux. pGPUMCD est comparé à Geant4, et les procédés physiques implémentés sont validés les uns après les autres. Pour les cas cliniques de calcul de dose, 27 matériaux sont définis pour la segmentation des tissus du scanner tomodensitométrique. L’exactitude dosimétrique du formalisme Leq est meilleure que 0.31% pour divers milieux allant de l’eau à l’or. Les gains d’efficacité intrinsèque au formalisme Leq sont supérieurs à 30 : entre 100 et 630 à précisions dosimétriques similaires. Combiné à l’accélération du GPU, le gain d’efficacité est d’un ordre de grandeur supérieur à 10⁵. pGPUMCD concorde à Geant4 à moins de 1% jusqu’au pic de Bragg et à moins de 3% dans sa pénombre distale, pour différentes configurations de simulations allant des milieux homogènes jusqu’aux cas cliniques. De plus, 99.5% des points de dose passent le critère 1% et les portées de prescription concordent avec celles de Geant4 à moins 0.1%. Les temps de calcul de pGPUMCD sont inférieurs à 0.5 seconde par million de protons transportés contre plusieurs heures avec Geant4. Les performances dosimétriques et d’efficacité de pGPUMCD lui confèrent les bonnes caractéristiques pour être employé dans un environnement de planification dosimétrique clinique. L’apport médical attendu est un meilleur contrôle sur les doses administrées, ce qui permet une réduction significative des marges et des toxicités des traitements. / In radiotherapy, treatment planning is the optimization of the ballistics to administer the prescribed dose to the treated lesions while minimizing collateral doses received by the healthy tissue. The algorithm of the dose calculation is at the heart of this numerical simulation. It must be precise and computationally efficient. The antagonism of these two features has led to the development of rapid analytical algorithms whose improvement in dosimetric accuracy has nowadays reached its limit. The accuracy of the dose calculation algorithm is particularly important in proton therapy to fully exploit the ballistic potential of protons. The Monte Carlo proton transport method is the most accurate but also the least efficient. This thesis deals with the development of a Monte Carlo dose calculation platform that is sufficiently effective to consider its use in clinical routine. The main objective of the project is to accelerate the Monte Carlo proton transport without compromising the precision of the dose deposition. To do this, two lines of research have been exploited. The first was to establish a new variance reduction technique called the equivalent restricted stopping power formalism (formalism Leq). This technique significantly improves the algorithmic time complexity made constant (O(1)) instead of linear (O(n)) for the current Monte Carlo algorithms. The second line of research focused on the use of graphics processing units to improve the execution speed of the proton Monte Carlo transport. The developed platform, named pGPUMCD, transports protons on graphic processors in a voxelized geometry. In pGPUMCD, condensed and discrete interaction techniques are considered. The inelastic low-range interactions are modeled with a continuous proton slowing down using the Leq formalism and the energy straggling is considered. The elastic interactions are based on the multiple Coulomb scattering. The discrete interactions are the inelastic interactions, the nuclear elastic and the non-elastic proton-nuclei interactions. pGPUMCD is compared to Geant4 and the implemented physical processes are validated one after the other. For the dose calculation in a clinical context, 27 materials are defined for the tissue segmentation from the CT scan. The dosimetric accuracy of the Leq formalism is better than 0.31% for various materials ranging from water to gold. The intrinsic efficiency gain factors of the Leq formalism are greater than 30, between 100 to 630 for a similar dosimetric accuracy. Combined with the GPU acceleration, the efficiency gain is an order of magnitude greater than 10⁵. Dose differences between pGPUMCD and Geant4 are smaller than 1% in the Bragg peak region and below 3% in its distal fall-off for the different simulation configurations with homogeneous phantoms and clinical cases. In addition, 99.5% of the dose points pass the criterion 1% and the prescribing ranges match with those of Geant4 at less than 0.1%. The computing times of pGPUMCD are below 0.5 seconds per million of transported protons compared to several hours with Geant4. The dosimetric and efficiency performances of pGPUMCD make it a good candidate to be used in a clinical dosimetric planning environment. The expected medical benefit is a better control of the delivered doses allowing a significant margin and toxicity reductions of the treatments.
2

Shielding study against high-energy neutrons produced in a proton therapy facility by means of Monte Carlo codes and on-site measurements / Etude de blindages pour un faisceau de protons thérapeutique: simulations par les méthodes de Monte Carlo et mesures au centre de protonthérapie d'Essen

Vanaudenhove, Thibault 12 June 2014 (has links)
Over the last few decades, radiotherapy using high-energy proton beams over the range from 50 MeV to 250 MeV has been increasingly used and developed. Indeed, it offers the possibility to focus the dose in a very narrow area around the tumor cells. The tumor control is improved compared to radiotherapy using photon beams and the healthy cells around the tumor are not irradiated since the range of charged particles is limited. However, due to nuclear reactions of the incident charged particles in the tissue, secondary high-energy radiations, essentially photons and neutrons, are produced and irradiate the treatment room.<p>As a consequence, thick concrete shielding walls are placed around the treatment room to ensure that other people and workers received a dose as small as possible. The dose measurement is performed with specific dosemeters such as the WENDI-II, which gives a conservative estimation of the ambient dose equivalent up to 5 GeV. The dose in working areas may also be estimated by means of numerical calculations by using simulation codes of particle transport such as the GEANT4, MCNPX, FLUKA and PHITS Monte Carlo codes.<p>Secondary particle yields calculated with Monte Carlo codes show discrepancies when different physical models are used but are globally in good agreement with experimental data from the literature. Neutron and photon doses decrease exponentially through concrete shielding wall but the neutron dose is definitely the main component behind a wall with sufficient thickness. Shielding parameters, e.g. attenuation coefficients, vary as functions of emission angle (regarding the incident beam direction), incident proton energy, and target material and composition.<p>The WENDI-II response functions computed by using different hadronic models show also some discrepancies. Thermal treatment of hydrogen in the polyethylene composing the detector is also of great importance to calculate the correct response function and the detector sensitivity.<p>Secondary particle sources in a proton therapy facility are essentially due to losses in cyclotron and beam interactions inside the energy selection system, with the treatment nozzle components and the target - patient or phantom. Numerical and experimental results of the dose in mazes show a good agreement for the most of detection points while they show large discrepancies in control rooms. Indeed, statistical consistency is reached with difficulty for both experimental and calculated results in control rooms since concrete walls are very thick in this case.<p>/<p>La radiothérapie utilisant des faisceaux de protons d’énergie entre 50 MeV et 250 MeV s’est largement développée ces dernières années. Elle a l’immense avantage de pouvoir concentrer la dose due au faisceau incident de manière très efficace et très précise sur la tumeur, en épargnant les éventuels organes sains et sensibles aux radiations situés aux alentours. Cependant, des rayonnements « secondaires » très énergétiques sont créés par les réactions nucléaires subies par les protons lors de leur parcours dans les tissus, et peuvent sortir du patient. Des blindages entourant la salle de traitement et suffisamment épais doivent être présents afin que la dose reçue par les personnes se trouvant aux alentours soit la plus faible possible. La mesure de la dose se fait avec des dosimètres spécifiques et sensibles aux rayonnements de haute énergie, tels que le WENDI-II pour les neutrons. L’estimation de cette dose, et donc la modélisation des blindages, se fait également avec des codes de simulation numérique de transport de particules par les méthodes de Monte Carlo, tels que GEANT4, MCNPX, FLUKA et PHITS.<p>La production de rayonnements secondaires calculée à l’aide de codes Monte Carlo montre des écarts significatifs lorsque différents modèles d’interactions physiques sont utilisés, mais est en bon accord avec des données expérimentales de référence. L’atténuation de la dose due aux neutrons et aux photons secondaires à travers un blindage composé de béton est exponentielle. De plus, la dose due aux neutrons est clairement la composante dominante au-delà d’une certaine épaisseur. Les paramètres d’atténuation, comme par exemple le coefficient d’atténuation, dépendent de l’angle d’émission (par rapport à la direction du faisceau incident), de l’énergie des protons incidents et de la nature et la composition de la cible.<p>La fonction de réponse du dosimètre WENDI-II montre également des variations lorsque différents modèles physiques sont considérés dans les codes Monte Carlo. La prise en compte d’effets fins comme les états de vibration et de rotation des atomes d’hydrogène au sein du polyéthylène composant le détecteur se révèle essentielle afin de caractériser correctement la réponse du détecteur ainsi que sa sensibilité.<p>L’émission secondaire dans un centre de protonthérapie est essentiellement due aux pertes dans le cyclotron et aux interactions du faisceau avec les systèmes de sélection de l’énergie, les composants de la tête de tir et le patient (ou le fantôme). L’évaluation numérique de la dose dans les labyrinthes des différentes salles du centre montre un bon accord avec les données expérimentales. Tandis que pour les points de mesure dans leur salle de contrôle respective, de larges différences peuvent apparaitre. Ceci est en partie dû à la difficulté d’obtenir des résultats statistiquement recevables du point de vue expérimental, mais aussi numérique, au vu de l’épaisseur des blindages entourant les salles de contrôle. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
3

Prompt gamma imaging with a slit camera for real time range control in particle therapy

Smeets, Julien 10 October 2012 (has links)
In a growing number of cutting edge centres around the world, radiotherapy treatments delivered by beams of protons and carbon ions offer the opportunity to target tumours with unprecedented conformality. But a sharper dose distribution increases the need for efficient quality control. Treatments are still affected by uncertainties on the penetration depth of the beam within the patient, requiring medical physicists to add safety margins. To reduce these margins and deliver safer treatments, different projects investigate real time range control by imaging prompt gammas emitted along the proton or carbon ion tracks in the patient.<p><p>This thesis reports on the feasibility, development and test of a new type of prompt gamma camera for proton therapy. This concept uses a knife-edge slit collimator to obtain a 1-dimensional projection of the beam path on a gamma camera. It was optimized, using the Monte Carlo code MCNPX version 2.5.0, to select high energy photons correlated with the beam range and detect them with both high counting statistics and sufficient spatial resolution for use in clinical routine. To validate the Monte Carlo model, spectrometry measurements of secondary particles emitted by a PMMA target during proton irradiation at 160 MeV were realised. An excellent agreement with the simulations was observed when using subtraction methods to isolate the gammas in direct incidence. A first prototype slit camera using the HiCam gamma detector was consequently prepared and tested successfully at 100 and 160 MeV beam energies. If we neglect electronic dead times and rejection of detected events, the current solution with its collimator at 15 cm from beam axis can achieve a 1-2 mm standard deviation on range estimation in a homogeneous PMMA target for numbers of protons that correspond to doses in water at Bragg peak as low as 15 cGy at 100 MeV and 25 cGy at 160 MeV assuming pencil beams with a Gaussian profile of 5 mm sigma at target entrance.<p><p>This thesis also investigates the applicability of the slit camera for carbon ion therapy. On the basis of Monte Carlo simulations with the code MCNPX version 2.7.E, this type of camera appears not to be able to identify the beam range with the required sensitivity. The feasibility of prompt gamma imaging itself seems questionable at high beam energies given the weak correlation of secondaries leaving the patient.<p><p>This work consequently concludes to the relevance of the slit camera approach for real time range monitoring in proton therapy, but not in carbon ion therapy. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished