The function of the human diaphragm as a volume pump and measurement of its efficiencySingh, Bhajan January 2004 (has links)
[Truncated abstract] The function of the diaphragm as a volume pump has not been adequately evaluated because there are no accurate methods to measure the volume displaced by diaphragm motion (ΔVdi). As a consequence, the work done, power output and efficiency of the diaphragm have not been measured. Efficiency of the diaphragm could be measured by relating the power output of the diaphragm to its neural activation. The aims of this thesis were to (a) develop a new biplanar radiographic method to measure ΔVdi and use this to evaluate the effect of costophrenic fibrosis and emphysema on ΔVdi, (b) develop a new fluoroscopic method to enable breath-by-breath measurements of ΔVdi, (c) evaluate a method for quantifying neural activation of the diaphragm, and (d) combine measurements of transdiaphragmatic pressure, ΔVdi, inspiratory duration and neural activation of the diaphragm to quantify the neuromechanical efficiency of the diaphragm
|
2 |
Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas / Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeriesTonelotto, Bruno Francisco de Freitas 03 December 2018 (has links)
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar / Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
|
3 |
Determinação da PEEP ideal e avaliação de atelectasia pulmonar com o uso da ultrassonografia durante intraoperatório de cirurgias eletivas / Ideal PEEP and evaluation of pulmonary atelectasia with the use of ultrasonography during intraoperatory of elective surgeriesBruno Francisco de Freitas Tonelotto 03 December 2018 (has links)
Introdução: A atelectasia intraoperatória ocorre imediatamente após a indução anestésica e pode ser detectada por ultrassom pulmonar (LUS). No entanto, até o momento o LUS não é utilizado para avaliar a hiperdistensão pulmonar. Neste estudo, descreveu-se um método para detectar hiperdistensão pulmonar usando LUS. A tomografia de impedância elétrica (TIE) foi a referência para comparação dos métodos. Métodos: Dezoito (18) pacientes, com 63 ± 6 anos de idade, com pulmões normais, submetidos à cirurgia abdominal inferior. O TIE foi calibrado, realizada a indução anestésica, intubação e ventilação mecânica. Para reverter a atelectasia posterior, realizou-se uma manobra de recrutamento alveolar com o uso de pressão expiratória final positiva (PEEP) 20 cmH20 e pressão aérea do platô 40 cmH2O durante 120 segundos. A titulação PEEP foi então obtida com valores descendentes: 20, 18, 16, 14,12,10, 8, 6 e 4 cmH2O. Os dados de ultrassom e TIE foram coletados em cada nível PEEP e interpretados por dois observadores independentes. O número de linhas H foi contado usando um filtro especial. O teste de correlação de Spearman e a curva ROC foram utilizados para comparar os dados do LUS e TIE. Resultados: O número de linhas H aumentou linearmente com PEEP: de 3 em PEEP 4 cmH2O a 10 em PEEP 20 cmH2O. Cinco linhas H foram o limiar para a detecção de hiperdistensão pulmonar, definida como hiperdistensão na TIE >= 24,5%. A área sob a curva ROC foi 0,947 (IC 95% 0.901-0.976). Conclusão: O LUS intraoperatório detectou hiperdistensão pulmonar em valores descendentes de PEEP. A presença de cinco ou mais linhas H podem ser consideradas como indicando hiperdistensão pulmonar / Purpose: Intraoperative atelectasis occurs immediately after anaesthetic induction and can be detected by lung ultrasound (LUS). However, LUS is considered as unable to assess pulmonary hyperinflation. In this study, we propose a method to detect pulmonary hyperinflation using LUS. Electrical impedance tomography (EIT) was the reference method. Methods: We included 18 patients, 63 ± 6-year old, with normal lungs, undergoing lower abdominal surgery. The following protocol was used: EIT was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment maneuver - positive end-expiratory pressure (PEEP) 20 cmH20 and plateau airway pressure 40 cmH2O during 120 sec was performed. PEEP titration was then obtained during a descending trial: 20, 18, 16, 14,12,10, 8, 6 and 4 cmH2O. Ultrasound and EIT data were collected at each PEEP level and analyzed by two independent observers. The number of H lines was counted using a special filter. Spearman correlation test and ROC curve were used to compare LUS and EIT data. Results: The number of H lines increased linearly with PEEP: from 3 at PEEP 4 cmH2O to 10 at PEEP 20 cmH2O. Five H lines was the threshold for detecting pulmonary hyperinflation, defined as a mean decrease in maximum EIT compliance >= 24,5 %. The area under the ROC curve was 0.947 (CI 95% 0.901-0.976). Conclusion: Intraoperative transthoracic LUS can detect pulmonary hyperinflation during a PEEP descending trial. Five or more H lines can be considered as indicating pulmonary hyperinflation in normally aerated lung regions
|