Manutenção de uma instalação de AVAC das áreas limpas de uma indústria farmacêutica

Marques, José Manuel Fialho January 2005 (has links)
Tese de mestrado. Manutenção Industrial. Faculdade de Engenharia. Universidade do Porto. 2005
2

Estudo do conforto térmico, do consumo energético e da qualidade do ar interior em salas cirúrgicas, através da simulação computacional e análise de layout / Study of the thermal comfort, the energy consumption and indoor air quality in operating rooms, through computational simulation and architectural analysis

Melhado, Monica do Amaral January 2003 (has links)
No presente trabalho foi feita a simulação computacional de três salas cirúrgicas e de alguns ambientes contíguos. Este estudo teve como objetivo verificar a influência dos diferentes layouts no conforto térmico dos ocupantes, na qualidade do ar interior, no dimensionamento dos equipamentos de climatização e no gasto energético. Todos os ambientes foram simulados para as condições climáticas de cinco capitais Brasileiras: Belém, Brasília, Porto Alegre, Recife e São Paulo. Estudou-se três tipos de distribuição arquitetônica. No Caso 1, o layout apresentado foi uma sala cirúrgica e um corredor. No Caso 2 foram analisados a sala cirúrgica, um corredor limpo e um corredor “sujo” (corredor de expurgo); enquanto no Caso 3, a sala cirúrgica, antecâmara e corredor. Os ambientes estudados são hipotéticos. As características construtivas e parâmetros ambientais (temperatura, umidade relativa, velocidade do ar, etc.) foram pré-estabelecidos segundo o tipo de cirurgia, baseando-se em normas brasileiras e algumas internacionais. Os tipos de cirurgias estudadas foram a ortopédica e a abdominal, considerando-as, respectivamente, asséptica e séptica. O conforto térmico foi calculado para os seguintes ocupantes: paciente, cirurgiã, anestesista, enfermeira auxiliar, enfermeira instrumentadora, enfermeira circulante, equipe de preparo e equipe de limpeza, pessoas no corredor e pessoas acessando a antecâmara. A escala utilizada para estabelecer as condições de conforto térmico, foi a ISO 7730. O gasto energético foi simulado para o período de um ano de projeto, enquanto os demais parâmetros, para um dia de verão (21 de janeiro) e um dia de inverno (21 de julho). O software utilizado na simulação foi o Energy Plus, versão 1.03. Com o modelamento foi possível observar o comportamento de cada parâmetro requerido, dentro de um espaço de tempo e nas diferentes regiões brasileiras estudadas. Na simulação, verificou-se que as variáveis, temperatura e umidade relativa, mantiveram-se dentro dos parâmetros exigidos. Estas variáveis, estando sob controle, não expuseram o ambiente a condições favoráveis para a amplificação de microorganismos. O controle de contaminantes nos ambientes, fez-se a partir do diferencial de pressão, da política de acesso de pessoas às salas cirúrgicas, bem como as filtragens recomendadas pelas normas. Com o dimensionamento dos equipamentos, foi possível ter as potências de cada fan-coil no dia de verão e de inverno para cada cidade e tipo de cirurgia. A menor potência encontrada para a sala cirúrgica foi no Caso 2. Dentro das análises realizadas, o layout do Caso 2 se mostrou mais eficiente, do ponto de vista energético, e em relação ao conforto térmico. Em todos os casos o anestesista e o paciente encontraram-se em situação de extremo desconforto, porém, no dia de inverno no Caso 2, apresentaram uma pequena melhora na sensação térmica, enquanto as demais pessoas, mantiveram-se em conforto ou pouco desconfortáveis. Analisando a política de acesso às salas cirúrgicas o layout com dois corredores permite um maior controle da sala cirurgica, diminuindo assim o risco de infecção cruzada nestes ambientes. Com o controle do ambiente interior, melhora-se as condições de segurança e saúde do corpo clínico e pacientes. O uso de simulação computacional mostrou-se uma importante ferramenta de suporte, permitindo avaliar o desempenho de diferentes soluções. A simulação computacional permite identificar ainda na fase de projeto, os projetos que são mais adequados ao uso do ambiente e o de maior qualidade, e os mais eficientes do ponto de vista energético. / At the present report, was made a computational simulation of three operating rooms and some adjacent areas. The purpose of this study was to verify the influence of the different layouts in the thermal comfort of the occupants, the indoor air quality, in the HVAC characteristics and in the energy consumption. All the environments were simulated according to the climate conditions of five Brazilian capitals: Belem, Brasilia, Porto Alegre, Recife e Sao Paulo. Three different layouts were studied. In Case 1, the layout consisted of an operating room and a hallway. Case 2 consisted of an operating room, a hallway with ultra-clean air and a second hallway with normal air treatment which is used as exit from the operating room and remove contaminated materials and instruments. Case 3 were considered an operating room, an antechamber and a hallway. The three cases described and studied are hypothetical. The constructive characteristics and the environmental parameters (temperatures, relative humidity, the air velocity, pressure, filters, etc.) were established according to the type of surgery and also based on Brazilian and some International standards. Two types of surgeries were evaluated: the orthopedic and the abdominal, considering them aseptic and septic, respectively. The thermal comfort of the patient, surgical team, support staff and the person, who cleans the operating room, were evaluated. The scale ISO 7730 was used to establish the thermal comfort conditions. The energy consumption was simulated for a one-year project, while the other parameters for one Summer day (21st January) and one Winter day (21st July). The software used in the simulation was the Energy Plus, version 1.03. With the modeling, it was possible to observe the behavior of each required parameters within a time space in the different Brazilian capitals. In the simulation, the environment temperature and the relative humidity were analyzed, and they remained in the demanded parameters. Those variables were under control and, therefore do not exposed the environment to favorable conditions of microorganisms increase. The architectural analysis was made to the politics of people’s access to the operating room. With the equipment dimensioning, it was possible to have the potencies of each fan-coil in the Summer and Winter day for each city and kind of surgery. The lowest power found was the one for the surgery room in Case 2. Based on the results of the simulations, comparing the performance of the three different layouts, Case 2 revealed to be more efficient on the energy consumption and also to the thermal comfort. However, in Case 1, 2 and 3, the anesthesiologist and the patient were in a situation of extreme thermal discomfort, although in winter day Case 2 revealed a small improvement on the feeling of thermal discomfort, while the other people remained in comfort or a little thermal discomfort. Analyzing the politics of people’s access to the operating rooms, Case 2 provides higher control of the indoor environment, since the surgical team and aseptic materials and instruments enter in the operating room for a hallway with clean air and leave the room for another hallway. Case 2 layout works as an architectonic barrier, defining the people behavior in the Operating Unit and, therefore, decreasing the risk of cross-infection. A computational simulation is an important support tool in the performance assessment of architectonic solutions. The use of computational simulation permits to compare and evaluate different design solutions during the design process, and to identify designs that are more efficient, adequate for the use and that provides improved indoor environment quality for the users.
3

Estudo do conforto térmico, do consumo energético e da qualidade do ar interior em salas cirúrgicas, através da simulação computacional e análise de layout / Study of the thermal comfort, the energy consumption and indoor air quality in operating rooms, through computational simulation and architectural analysis

Melhado, Monica do Amaral January 2003 (has links)
No presente trabalho foi feita a simulação computacional de três salas cirúrgicas e de alguns ambientes contíguos. Este estudo teve como objetivo verificar a influência dos diferentes layouts no conforto térmico dos ocupantes, na qualidade do ar interior, no dimensionamento dos equipamentos de climatização e no gasto energético. Todos os ambientes foram simulados para as condições climáticas de cinco capitais Brasileiras: Belém, Brasília, Porto Alegre, Recife e São Paulo. Estudou-se três tipos de distribuição arquitetônica. No Caso 1, o layout apresentado foi uma sala cirúrgica e um corredor. No Caso 2 foram analisados a sala cirúrgica, um corredor limpo e um corredor “sujo” (corredor de expurgo); enquanto no Caso 3, a sala cirúrgica, antecâmara e corredor. Os ambientes estudados são hipotéticos. As características construtivas e parâmetros ambientais (temperatura, umidade relativa, velocidade do ar, etc.) foram pré-estabelecidos segundo o tipo de cirurgia, baseando-se em normas brasileiras e algumas internacionais. Os tipos de cirurgias estudadas foram a ortopédica e a abdominal, considerando-as, respectivamente, asséptica e séptica. O conforto térmico foi calculado para os seguintes ocupantes: paciente, cirurgiã, anestesista, enfermeira auxiliar, enfermeira instrumentadora, enfermeira circulante, equipe de preparo e equipe de limpeza, pessoas no corredor e pessoas acessando a antecâmara. A escala utilizada para estabelecer as condições de conforto térmico, foi a ISO 7730. O gasto energético foi simulado para o período de um ano de projeto, enquanto os demais parâmetros, para um dia de verão (21 de janeiro) e um dia de inverno (21 de julho). O software utilizado na simulação foi o Energy Plus, versão 1.03. Com o modelamento foi possível observar o comportamento de cada parâmetro requerido, dentro de um espaço de tempo e nas diferentes regiões brasileiras estudadas. Na simulação, verificou-se que as variáveis, temperatura e umidade relativa, mantiveram-se dentro dos parâmetros exigidos. Estas variáveis, estando sob controle, não expuseram o ambiente a condições favoráveis para a amplificação de microorganismos. O controle de contaminantes nos ambientes, fez-se a partir do diferencial de pressão, da política de acesso de pessoas às salas cirúrgicas, bem como as filtragens recomendadas pelas normas. Com o dimensionamento dos equipamentos, foi possível ter as potências de cada fan-coil no dia de verão e de inverno para cada cidade e tipo de cirurgia. A menor potência encontrada para a sala cirúrgica foi no Caso 2. Dentro das análises realizadas, o layout do Caso 2 se mostrou mais eficiente, do ponto de vista energético, e em relação ao conforto térmico. Em todos os casos o anestesista e o paciente encontraram-se em situação de extremo desconforto, porém, no dia de inverno no Caso 2, apresentaram uma pequena melhora na sensação térmica, enquanto as demais pessoas, mantiveram-se em conforto ou pouco desconfortáveis. Analisando a política de acesso às salas cirúrgicas o layout com dois corredores permite um maior controle da sala cirurgica, diminuindo assim o risco de infecção cruzada nestes ambientes. Com o controle do ambiente interior, melhora-se as condições de segurança e saúde do corpo clínico e pacientes. O uso de simulação computacional mostrou-se uma importante ferramenta de suporte, permitindo avaliar o desempenho de diferentes soluções. A simulação computacional permite identificar ainda na fase de projeto, os projetos que são mais adequados ao uso do ambiente e o de maior qualidade, e os mais eficientes do ponto de vista energético. / At the present report, was made a computational simulation of three operating rooms and some adjacent areas. The purpose of this study was to verify the influence of the different layouts in the thermal comfort of the occupants, the indoor air quality, in the HVAC characteristics and in the energy consumption. All the environments were simulated according to the climate conditions of five Brazilian capitals: Belem, Brasilia, Porto Alegre, Recife e Sao Paulo. Three different layouts were studied. In Case 1, the layout consisted of an operating room and a hallway. Case 2 consisted of an operating room, a hallway with ultra-clean air and a second hallway with normal air treatment which is used as exit from the operating room and remove contaminated materials and instruments. Case 3 were considered an operating room, an antechamber and a hallway. The three cases described and studied are hypothetical. The constructive characteristics and the environmental parameters (temperatures, relative humidity, the air velocity, pressure, filters, etc.) were established according to the type of surgery and also based on Brazilian and some International standards. Two types of surgeries were evaluated: the orthopedic and the abdominal, considering them aseptic and septic, respectively. The thermal comfort of the patient, surgical team, support staff and the person, who cleans the operating room, were evaluated. The scale ISO 7730 was used to establish the thermal comfort conditions. The energy consumption was simulated for a one-year project, while the other parameters for one Summer day (21st January) and one Winter day (21st July). The software used in the simulation was the Energy Plus, version 1.03. With the modeling, it was possible to observe the behavior of each required parameters within a time space in the different Brazilian capitals. In the simulation, the environment temperature and the relative humidity were analyzed, and they remained in the demanded parameters. Those variables were under control and, therefore do not exposed the environment to favorable conditions of microorganisms increase. The architectural analysis was made to the politics of people’s access to the operating room. With the equipment dimensioning, it was possible to have the potencies of each fan-coil in the Summer and Winter day for each city and kind of surgery. The lowest power found was the one for the surgery room in Case 2. Based on the results of the simulations, comparing the performance of the three different layouts, Case 2 revealed to be more efficient on the energy consumption and also to the thermal comfort. However, in Case 1, 2 and 3, the anesthesiologist and the patient were in a situation of extreme thermal discomfort, although in winter day Case 2 revealed a small improvement on the feeling of thermal discomfort, while the other people remained in comfort or a little thermal discomfort. Analyzing the politics of people’s access to the operating rooms, Case 2 provides higher control of the indoor environment, since the surgical team and aseptic materials and instruments enter in the operating room for a hallway with clean air and leave the room for another hallway. Case 2 layout works as an architectonic barrier, defining the people behavior in the Operating Unit and, therefore, decreasing the risk of cross-infection. A computational simulation is an important support tool in the performance assessment of architectonic solutions. The use of computational simulation permits to compare and evaluate different design solutions during the design process, and to identify designs that are more efficient, adequate for the use and that provides improved indoor environment quality for the users.
4

Estudo do conforto térmico, do consumo energético e da qualidade do ar interior em salas cirúrgicas, através da simulação computacional e análise de layout / Study of the thermal comfort, the energy consumption and indoor air quality in operating rooms, through computational simulation and architectural analysis

Melhado, Monica do Amaral January 2003 (has links)
No presente trabalho foi feita a simulação computacional de três salas cirúrgicas e de alguns ambientes contíguos. Este estudo teve como objetivo verificar a influência dos diferentes layouts no conforto térmico dos ocupantes, na qualidade do ar interior, no dimensionamento dos equipamentos de climatização e no gasto energético. Todos os ambientes foram simulados para as condições climáticas de cinco capitais Brasileiras: Belém, Brasília, Porto Alegre, Recife e São Paulo. Estudou-se três tipos de distribuição arquitetônica. No Caso 1, o layout apresentado foi uma sala cirúrgica e um corredor. No Caso 2 foram analisados a sala cirúrgica, um corredor limpo e um corredor “sujo” (corredor de expurgo); enquanto no Caso 3, a sala cirúrgica, antecâmara e corredor. Os ambientes estudados são hipotéticos. As características construtivas e parâmetros ambientais (temperatura, umidade relativa, velocidade do ar, etc.) foram pré-estabelecidos segundo o tipo de cirurgia, baseando-se em normas brasileiras e algumas internacionais. Os tipos de cirurgias estudadas foram a ortopédica e a abdominal, considerando-as, respectivamente, asséptica e séptica. O conforto térmico foi calculado para os seguintes ocupantes: paciente, cirurgiã, anestesista, enfermeira auxiliar, enfermeira instrumentadora, enfermeira circulante, equipe de preparo e equipe de limpeza, pessoas no corredor e pessoas acessando a antecâmara. A escala utilizada para estabelecer as condições de conforto térmico, foi a ISO 7730. O gasto energético foi simulado para o período de um ano de projeto, enquanto os demais parâmetros, para um dia de verão (21 de janeiro) e um dia de inverno (21 de julho). O software utilizado na simulação foi o Energy Plus, versão 1.03. Com o modelamento foi possível observar o comportamento de cada parâmetro requerido, dentro de um espaço de tempo e nas diferentes regiões brasileiras estudadas. Na simulação, verificou-se que as variáveis, temperatura e umidade relativa, mantiveram-se dentro dos parâmetros exigidos. Estas variáveis, estando sob controle, não expuseram o ambiente a condições favoráveis para a amplificação de microorganismos. O controle de contaminantes nos ambientes, fez-se a partir do diferencial de pressão, da política de acesso de pessoas às salas cirúrgicas, bem como as filtragens recomendadas pelas normas. Com o dimensionamento dos equipamentos, foi possível ter as potências de cada fan-coil no dia de verão e de inverno para cada cidade e tipo de cirurgia. A menor potência encontrada para a sala cirúrgica foi no Caso 2. Dentro das análises realizadas, o layout do Caso 2 se mostrou mais eficiente, do ponto de vista energético, e em relação ao conforto térmico. Em todos os casos o anestesista e o paciente encontraram-se em situação de extremo desconforto, porém, no dia de inverno no Caso 2, apresentaram uma pequena melhora na sensação térmica, enquanto as demais pessoas, mantiveram-se em conforto ou pouco desconfortáveis. Analisando a política de acesso às salas cirúrgicas o layout com dois corredores permite um maior controle da sala cirurgica, diminuindo assim o risco de infecção cruzada nestes ambientes. Com o controle do ambiente interior, melhora-se as condições de segurança e saúde do corpo clínico e pacientes. O uso de simulação computacional mostrou-se uma importante ferramenta de suporte, permitindo avaliar o desempenho de diferentes soluções. A simulação computacional permite identificar ainda na fase de projeto, os projetos que são mais adequados ao uso do ambiente e o de maior qualidade, e os mais eficientes do ponto de vista energético. / At the present report, was made a computational simulation of three operating rooms and some adjacent areas. The purpose of this study was to verify the influence of the different layouts in the thermal comfort of the occupants, the indoor air quality, in the HVAC characteristics and in the energy consumption. All the environments were simulated according to the climate conditions of five Brazilian capitals: Belem, Brasilia, Porto Alegre, Recife e Sao Paulo. Three different layouts were studied. In Case 1, the layout consisted of an operating room and a hallway. Case 2 consisted of an operating room, a hallway with ultra-clean air and a second hallway with normal air treatment which is used as exit from the operating room and remove contaminated materials and instruments. Case 3 were considered an operating room, an antechamber and a hallway. The three cases described and studied are hypothetical. The constructive characteristics and the environmental parameters (temperatures, relative humidity, the air velocity, pressure, filters, etc.) were established according to the type of surgery and also based on Brazilian and some International standards. Two types of surgeries were evaluated: the orthopedic and the abdominal, considering them aseptic and septic, respectively. The thermal comfort of the patient, surgical team, support staff and the person, who cleans the operating room, were evaluated. The scale ISO 7730 was used to establish the thermal comfort conditions. The energy consumption was simulated for a one-year project, while the other parameters for one Summer day (21st January) and one Winter day (21st July). The software used in the simulation was the Energy Plus, version 1.03. With the modeling, it was possible to observe the behavior of each required parameters within a time space in the different Brazilian capitals. In the simulation, the environment temperature and the relative humidity were analyzed, and they remained in the demanded parameters. Those variables were under control and, therefore do not exposed the environment to favorable conditions of microorganisms increase. The architectural analysis was made to the politics of people’s access to the operating room. With the equipment dimensioning, it was possible to have the potencies of each fan-coil in the Summer and Winter day for each city and kind of surgery. The lowest power found was the one for the surgery room in Case 2. Based on the results of the simulations, comparing the performance of the three different layouts, Case 2 revealed to be more efficient on the energy consumption and also to the thermal comfort. However, in Case 1, 2 and 3, the anesthesiologist and the patient were in a situation of extreme thermal discomfort, although in winter day Case 2 revealed a small improvement on the feeling of thermal discomfort, while the other people remained in comfort or a little thermal discomfort. Analyzing the politics of people’s access to the operating rooms, Case 2 provides higher control of the indoor environment, since the surgical team and aseptic materials and instruments enter in the operating room for a hallway with clean air and leave the room for another hallway. Case 2 layout works as an architectonic barrier, defining the people behavior in the Operating Unit and, therefore, decreasing the risk of cross-infection. A computational simulation is an important support tool in the performance assessment of architectonic solutions. The use of computational simulation permits to compare and evaluate different design solutions during the design process, and to identify designs that are more efficient, adequate for the use and that provides improved indoor environment quality for the users.
5

Avaliação da qualidade ambiental interna no transporte coletivo da cidade de São Carlos, SP / Assessment of indoor environmental quality in public transport from the city of São Carlos, SP

Peiter, Fernanda Santana 12 May 2014 (has links)
A circulação no trânsito das cidades faz parte da rotina das pessoas, que podem despender tempos consideráveis dentro de automóveis durante seus deslocamentos. Fatores como a emissão de gases provinda do tráfego e a má circulação de ar podem afetar a qualidade ambiental no interior dos veículos e torná-lo prejudicial à saúde de seus ocupantes. Sendo assim, durante vinte dias aleatórios, entre agosto e dezembro de 2013, monitorou-se o ambiente interno de um dos ônibus pertencentes ao sistema de transporte coletivo da cidade de São Carlos. Foram medidos temperatura, umidade relativa do ar, ruído, monóxido e dióxido de carbono, compostos orgânicos voláteis totais (COVT) e material particulado. Os dados encontrados foram analisados baseando-se em distintas normas e padrões. Observou-se também a influência dos parâmetros avaliados na saúde das pessoas, de acordo com a literatura. Dentre as referências consultadas, consideraram-se os valores limites recomendados pelo Ministério do Trabalho e Emprego (normas NR-15, NR-17 e NHO 01), pela Agência Nacional de Vigilância Sanitária (Resolução 09/03), pelo Conselho Nacional de Meio Ambiente (Resolução 03/90) e pela Organização Mundial de Saúde. A partir dos dados de temperatura e umidade relativa do ar, calculou-se o índice de calor (Heat Index) utilizado pela National Oceanic and Atmospheric Administration dos EUA, para averiguação do conforto térmico. Os resultados mostraram que os níveis de temperatura, umidade relativa, índice de calor e material particulado estiveram, em sua maioria, acima dos valores referenciais. O ruído também constitui um fator preocupante, apesar de os valores encontrados estarem abaixo do limite máximo de 85 dB(A), pois, pesquisas recentes indicam que níveis acima de 60 dB(A) tendem trazer complicações à saúde (Willich et al., 2006). Ao observar as concentrações dos óxidos de carbono, notou-se a interferência da poluição provinda do meio externo. Por fim, conclui-se que a qualidade ambiental interna do ônibus pode ser prejudicial principalmente aos cobradores e motoristas, que trabalham neste ambiente por muitas horas diárias. / The movement of traffic in cities is part of the people\'s routine that can spend considerable time inside automobiles during their displacement. Factors such as greenhouse gas emissions from traffic and poor air circulation can affect the environmental quality inside vehicles and make it harmful to the health of its occupants. Thus, for twenty random days between August and December 2013, air quality inside one of the buses belonging to the public transportation system of the city of São Carlos was monitored. Temperature, relative humidity, noise, carbon monoxide, carbon dioxide, volatile organic compounds (TVOC) and particulate matter were measured. Data were analyzed based on limiting values recommended by different institutions and observing the influence of the parameters measured in people\'s health, according to the literature. Were taken as reference standards established by the Ministry of Labor and Employment (standards NR-15, NR-17 and NHO 01), the National Health Surveillance Agency (Resolution 09/03), the National Environmental Council (Resolution 03 / 90) and the World Health Organization. Aiming to verify the thermal sensation, we calculated the Heat Index used by the National Oceanic and Atmospheric Administration of the USA. The results show that levels of temperature, relative humidity, heat index and particulate matter are mostly above the reference values. Noise is also a worrying factor, despite being within the ceiling of 85 dB (A), because, according to recent surveys, over 60 dB (A) there is potential damage to health (Willich et al., 2006). By observing the concentrations of oxides of carbon, it was noted interference stemmed from the pollution of the external environment. Finally, it is concluded that the air quality inside the bus can be harmful especially to collectors and drivers, working in this environment for many hours a day.
6

Avaliação da qualidade ambiental interna no transporte coletivo da cidade de São Carlos, SP / Assessment of indoor environmental quality in public transport from the city of São Carlos, SP

Fernanda Santana Peiter 12 May 2014 (has links)
A circulação no trânsito das cidades faz parte da rotina das pessoas, que podem despender tempos consideráveis dentro de automóveis durante seus deslocamentos. Fatores como a emissão de gases provinda do tráfego e a má circulação de ar podem afetar a qualidade ambiental no interior dos veículos e torná-lo prejudicial à saúde de seus ocupantes. Sendo assim, durante vinte dias aleatórios, entre agosto e dezembro de 2013, monitorou-se o ambiente interno de um dos ônibus pertencentes ao sistema de transporte coletivo da cidade de São Carlos. Foram medidos temperatura, umidade relativa do ar, ruído, monóxido e dióxido de carbono, compostos orgânicos voláteis totais (COVT) e material particulado. Os dados encontrados foram analisados baseando-se em distintas normas e padrões. Observou-se também a influência dos parâmetros avaliados na saúde das pessoas, de acordo com a literatura. Dentre as referências consultadas, consideraram-se os valores limites recomendados pelo Ministério do Trabalho e Emprego (normas NR-15, NR-17 e NHO 01), pela Agência Nacional de Vigilância Sanitária (Resolução 09/03), pelo Conselho Nacional de Meio Ambiente (Resolução 03/90) e pela Organização Mundial de Saúde. A partir dos dados de temperatura e umidade relativa do ar, calculou-se o índice de calor (Heat Index) utilizado pela National Oceanic and Atmospheric Administration dos EUA, para averiguação do conforto térmico. Os resultados mostraram que os níveis de temperatura, umidade relativa, índice de calor e material particulado estiveram, em sua maioria, acima dos valores referenciais. O ruído também constitui um fator preocupante, apesar de os valores encontrados estarem abaixo do limite máximo de 85 dB(A), pois, pesquisas recentes indicam que níveis acima de 60 dB(A) tendem trazer complicações à saúde (Willich et al., 2006). Ao observar as concentrações dos óxidos de carbono, notou-se a interferência da poluição provinda do meio externo. Por fim, conclui-se que a qualidade ambiental interna do ônibus pode ser prejudicial principalmente aos cobradores e motoristas, que trabalham neste ambiente por muitas horas diárias. / The movement of traffic in cities is part of the people\'s routine that can spend considerable time inside automobiles during their displacement. Factors such as greenhouse gas emissions from traffic and poor air circulation can affect the environmental quality inside vehicles and make it harmful to the health of its occupants. Thus, for twenty random days between August and December 2013, air quality inside one of the buses belonging to the public transportation system of the city of São Carlos was monitored. Temperature, relative humidity, noise, carbon monoxide, carbon dioxide, volatile organic compounds (TVOC) and particulate matter were measured. Data were analyzed based on limiting values recommended by different institutions and observing the influence of the parameters measured in people\'s health, according to the literature. Were taken as reference standards established by the Ministry of Labor and Employment (standards NR-15, NR-17 and NHO 01), the National Health Surveillance Agency (Resolution 09/03), the National Environmental Council (Resolution 03 / 90) and the World Health Organization. Aiming to verify the thermal sensation, we calculated the Heat Index used by the National Oceanic and Atmospheric Administration of the USA. The results show that levels of temperature, relative humidity, heat index and particulate matter are mostly above the reference values. Noise is also a worrying factor, despite being within the ceiling of 85 dB (A), because, according to recent surveys, over 60 dB (A) there is potential damage to health (Willich et al., 2006). By observing the concentrations of oxides of carbon, it was noted interference stemmed from the pollution of the external environment. Finally, it is concluded that the air quality inside the bus can be harmful especially to collectors and drivers, working in this environment for many hours a day.
7

Qualidade do ar interior e conforto t?rmico : um estudo em espa?os de estacionamento em Natal/RN

Costa, Juliana Magna da Silva 13 May 2005 (has links)
Made available in DSpace on 2014-12-17T13:57:10Z (GMT). No. of bitstreams: 1 JulianaMSC.pdf: 2960475 bytes, checksum: ff925978b7f6c5c27eed0072ef0251db (MD5) Previous issue date: 2005-05-13 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air / A atual tend?ncia de utiliza??o dos espa?os destinados a estacionamento veicular para outras finalidades tem resultado num tempo maior de perman?ncia dos usu?rios nestes espa?os, principalmente nas grandes cidades. Por esta raz?o, o presente trabalho investiga a qualidade do ar interior e o conforto t?rmico em ?reas reservadas a estacionamentos, atrav?s da rela??o direta destes ambientes com a polui??o veicular. Para realiza??o deste estudo, optou-se por estacionamentos com tipologias arquitet?nicas diferenciadas, sendo um estacionamento aberto e um estacionamento fechado, ambos ventilados naturalmente, situados em Natal/RN, com o intuito de contribuir para a proposi??o de novos espa?os desta natureza adequados ? perman?ncia humana. Para tal, realizou-se pesquisa de campo nos dois estacionamentos em per?odos distintos (janeiro e julho), espa?o de tempo condizente com os per?odos clim?ticos caracter?sticos (ver?o e inverno, respectivamente) da referida cidade. As condicionantes ambientais internas foram mensuradas atrav?s de instrumentos de medi??es da temperatura do ar, umidade relativa do ar, velocidade do ar e dire??o dos ventos; as humanas, atrav?s de entrevistas aplicadas com usu?rios dos locais (visitantes e funcion?rios); e as qu?micas, atrav?s de instrumentos de medi??o apropriados para material particulado, mon?xido de carbono e oz?nio. Na an?lise dos resultados, constatou-se que as condicionantes qu?micas atingiram maiores concentra??es no estacionamento fechado. Este quadro foi agravado pelas condi??es clim?ticas do local (maiores temperaturas do ar), resultando num maior registro de usu?rios insatisfeitos. Constatou-se que a tipologia arquitet?nica de estacionamentos fechados, com contribui??o tamb?m de seu aspecto topogr?fico, compromete as condi??es ambientais internas, potencializando a reten??o de poluentes, acarretando espa?os com baixo ?ndice de conforto t?rmico para seus usu?rios, sendo, assim, menos adequados do ponto de vista da qualidade do ar interior e do conforto t?rmico
8

Particulate matter inside residences of elderly in the Metropolitan Area of São Paulo / Material particulado em residências de idosos na Região Metropolitana de São Paulo.

Segalin, Bruna 24 November 2017 (has links)
The elderly population is sensitive to damages caused by air pollution on health. They spend relatively more time indoors, however there is limited information on the air quality they breathe inside their residences. The objectives of this work are to characterise mass of sizesegregated particulate matter (PM) in elderly residences in Metropolitan Area of Sao Paulo (MASP) in Brazil; assess the meteorological parameters influence; evaluate the indoor and outdoor relationship of PM; quantify the ions, trace elements and black carbon (rBC) in quasi-ultrafine particles (qUFP) and identify their sources, and estimate the respiratory deposition doses (RDD). To achieve these objectives, we measured during 24 hours the mass concentrations of PM in differents sizes (102.5, 2.51.0, 1.00.5, 0.50.25 and <0.25 µm (PM0.25, qUFP) in 59 elderly residences in MASP using a Personal Cascade Impactor Sampler. The PM10 is the sum of all size and PM2.5 is PM10 less PM102.5. The PM2.5 and PM0.25 contributed 78% and 38% of total PM10, respectively. About 77% and 40% of the residences had higher PM2.5 and PM10 than those in outdoor environments. About 13 and 43% of the measurements exceeded the World Health Organization (WHO) guidelines for PM10 and PM2.5, respectively. The PM0.25 exceeded the WHO guideline for PM2.5 in 8.3% of residences. Residences with higher PM concentration in all size bins are predominantly near the heavy traffic areas during the nonprecipitation days. About 68% of residences have the highest mass concentration in PM0.25. We analysed ions by chromatography, trace elements by x-ray fluorescence and rBC by reflectance. The major of ions concentrations in qUFP were found to be SO42- and NH4+, and the major trace elements were Si and Fe. Around 26% of the qUFP is rBC. Some residences have a high concentration of the toxic heavy metals Cu, Ni, Pb and Cr. We identified 6 dominant sources of the indoor qUFP by positive matrix factorization: vehicular emission (57%), secondary inorganic aerosol (21%), soil and construction (7%), wall painting (7%), cooking (5%) and industry (3%). The RDD for coarse and fine particles were found to be 20% and 24.6% higher for male than female elderly during seated position, respectively. The maximum RDD of qUFP and rBC are in the tracheobronchial part. It is important the control of PM sources in the elderly residences to limit adverse health effects of PM, especially fine particles. We suggest consider the rBC as one regulated air pollutant in terms of public control actions for air quality improvement in MASP. / A população idosa é sensível aos riscos da poluição do ar à saúde. Os idosos passam mais tempo dentro de suas casas, mas há pouca informação sobre a qualidade do ar dentro de suas residências. Os objetivos deste trabalho são caracterizar a massa do material particulado (PM) de diferentes tamanhos em residências de idosos na Região Metropolitana de São Paulo (RMSP) no Brasil; avaliar a influência dos parâmetros meteorológicos e a relação entre PM de ambiente interno e externo; quantificar os íons, elementos traços e black carbon (rBC) em partículas quasi-ultrafinas (qUFP) e identificar suas fontes, e estimar as doses de deposição de PM no trato respiratório (RDD). Para alcançar esses objetivos, medimos durante 24 horas as concentrações em massa de PM nos tamanhos 10-2,5; 2,5-1,0; 1,0-0,5; 0,5-0,25 e <0,25 m (PM0.25, qUFP) em 59 residências de idosos na RMSP usando o Personal Cascade Impactor Sampler. O PM10 é a soma da massa em todos os tamanhos e PM2.5 é o PM10 menos o PM10-2.5. O PM2.5 e PM0.25 contribuíram com 78% e 38% do total de PM10, respectivamente. Cerca de 77% e 40% das residências apresentaram maior concentração de PM2.5 e PM10 do que aqueles em ambientes externos. Cerca de 13 e 43% das medidas excederam as diretrizes da Organização Mundial de Saúde (OMS) para PM10 e PM2.5, respectivamente. O PM0.25 excedeu o limiar da OMS para PM2.5 em 8.3% das residências. As residências com maior concentração de PM em todos os tamanhos estão próximas das áreas de intenso tráfego veicular e não houve precipitação durante a medição. Cerca de 68% das residências têm a maior concentração de massa em PM0.25. Analisamos os íons por cromatografia, elementos traços por fluorescência de raios-x e rBC por reflectância. A maior concentração de íons em qUFP foi SO42- e NH4+, e os principais elementos traços foram Si e Fe. Cerca de 26% do qUFP é rBC. Algumas residências têm uma alta concentração dos metais pesados tóxicos Cu, Ni, Pb e Cr. Identificou-se 6 fontes de qUFP por fatoração de matriz positiva: emissão de veículos (57%), aerossol inorgânico secundário (21%), solo e construção (7%), pintura de parede (7%), cozimento (5%) e indústria (3%). O RDD para PM10-2.5 e PM2.5 foi 20% e 24,6% maior para homens do que mulheres enquanto sentados, respectivamente. O RDD máximo de qUFP e rBC foi na parte traqueobrônquica. É importante o controle de fontes de PM nas residências de idosos para limitar os efeitos adversos à saúde, especialmente partículas finas. Sugerimos considerar o rBC como um poluente atmosférico regulado em termos de ações de controle público para a melhoria da qualidade do ar na RMSP.
9

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Marè, Renata Maria 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
10

Particulate matter inside residences of elderly in the Metropolitan Area of São Paulo / Material particulado em residências de idosos na Região Metropolitana de São Paulo.

Bruna Segalin 24 November 2017 (has links)
The elderly population is sensitive to damages caused by air pollution on health. They spend relatively more time indoors, however there is limited information on the air quality they breathe inside their residences. The objectives of this work are to characterise mass of sizesegregated particulate matter (PM) in elderly residences in Metropolitan Area of Sao Paulo (MASP) in Brazil; assess the meteorological parameters influence; evaluate the indoor and outdoor relationship of PM; quantify the ions, trace elements and black carbon (rBC) in quasi-ultrafine particles (qUFP) and identify their sources, and estimate the respiratory deposition doses (RDD). To achieve these objectives, we measured during 24 hours the mass concentrations of PM in differents sizes (102.5, 2.51.0, 1.00.5, 0.50.25 and <0.25 µm (PM0.25, qUFP) in 59 elderly residences in MASP using a Personal Cascade Impactor Sampler. The PM10 is the sum of all size and PM2.5 is PM10 less PM102.5. The PM2.5 and PM0.25 contributed 78% and 38% of total PM10, respectively. About 77% and 40% of the residences had higher PM2.5 and PM10 than those in outdoor environments. About 13 and 43% of the measurements exceeded the World Health Organization (WHO) guidelines for PM10 and PM2.5, respectively. The PM0.25 exceeded the WHO guideline for PM2.5 in 8.3% of residences. Residences with higher PM concentration in all size bins are predominantly near the heavy traffic areas during the nonprecipitation days. About 68% of residences have the highest mass concentration in PM0.25. We analysed ions by chromatography, trace elements by x-ray fluorescence and rBC by reflectance. The major of ions concentrations in qUFP were found to be SO42- and NH4+, and the major trace elements were Si and Fe. Around 26% of the qUFP is rBC. Some residences have a high concentration of the toxic heavy metals Cu, Ni, Pb and Cr. We identified 6 dominant sources of the indoor qUFP by positive matrix factorization: vehicular emission (57%), secondary inorganic aerosol (21%), soil and construction (7%), wall painting (7%), cooking (5%) and industry (3%). The RDD for coarse and fine particles were found to be 20% and 24.6% higher for male than female elderly during seated position, respectively. The maximum RDD of qUFP and rBC are in the tracheobronchial part. It is important the control of PM sources in the elderly residences to limit adverse health effects of PM, especially fine particles. We suggest consider the rBC as one regulated air pollutant in terms of public control actions for air quality improvement in MASP. / A população idosa é sensível aos riscos da poluição do ar à saúde. Os idosos passam mais tempo dentro de suas casas, mas há pouca informação sobre a qualidade do ar dentro de suas residências. Os objetivos deste trabalho são caracterizar a massa do material particulado (PM) de diferentes tamanhos em residências de idosos na Região Metropolitana de São Paulo (RMSP) no Brasil; avaliar a influência dos parâmetros meteorológicos e a relação entre PM de ambiente interno e externo; quantificar os íons, elementos traços e black carbon (rBC) em partículas quasi-ultrafinas (qUFP) e identificar suas fontes, e estimar as doses de deposição de PM no trato respiratório (RDD). Para alcançar esses objetivos, medimos durante 24 horas as concentrações em massa de PM nos tamanhos 10-2,5; 2,5-1,0; 1,0-0,5; 0,5-0,25 e <0,25 m (PM0.25, qUFP) em 59 residências de idosos na RMSP usando o Personal Cascade Impactor Sampler. O PM10 é a soma da massa em todos os tamanhos e PM2.5 é o PM10 menos o PM10-2.5. O PM2.5 e PM0.25 contribuíram com 78% e 38% do total de PM10, respectivamente. Cerca de 77% e 40% das residências apresentaram maior concentração de PM2.5 e PM10 do que aqueles em ambientes externos. Cerca de 13 e 43% das medidas excederam as diretrizes da Organização Mundial de Saúde (OMS) para PM10 e PM2.5, respectivamente. O PM0.25 excedeu o limiar da OMS para PM2.5 em 8.3% das residências. As residências com maior concentração de PM em todos os tamanhos estão próximas das áreas de intenso tráfego veicular e não houve precipitação durante a medição. Cerca de 68% das residências têm a maior concentração de massa em PM0.25. Analisamos os íons por cromatografia, elementos traços por fluorescência de raios-x e rBC por reflectância. A maior concentração de íons em qUFP foi SO42- e NH4+, e os principais elementos traços foram Si e Fe. Cerca de 26% do qUFP é rBC. Algumas residências têm uma alta concentração dos metais pesados tóxicos Cu, Ni, Pb e Cr. Identificou-se 6 fontes de qUFP por fatoração de matriz positiva: emissão de veículos (57%), aerossol inorgânico secundário (21%), solo e construção (7%), pintura de parede (7%), cozimento (5%) e indústria (3%). O RDD para PM10-2.5 e PM2.5 foi 20% e 24,6% maior para homens do que mulheres enquanto sentados, respectivamente. O RDD máximo de qUFP e rBC foi na parte traqueobrônquica. É importante o controle de fontes de PM nas residências de idosos para limitar os efeitos adversos à saúde, especialmente partículas finas. Sugerimos considerar o rBC como um poluente atmosférico regulado em termos de ações de controle público para a melhoria da qualidade do ar na RMSP.