• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception conjointe optimisée de lois de contrôle et d'ordonnancement / Integrated optimal control and scheduling co-design

Jia, Ning 15 January 2009 (has links)
Le cadre de ce travail est l’étude coordonnée de lois de contrôle et d’ordonnancement. Le premier objectif est de proposer et évaluer une approche de contrôle de la dégradation de la Qualité de Contrôle (QdC) par rejet sélectif d’instances de tâches ou de messages selon le modèle (m,k)-firm. Plus particulièrement, nous avons étudié l’impact de distribution de rejets sur la QdC d'une boucle de contrôle et, sur la base des résultats obtenus, nous avons spécifié une méthode de co-conception permettant de déterminer les paramètres (gain) optimaux de la loi de contrôle et les paramètres de la contrainte (m,k)-firm spécifiant le rejet sélectif d’instances. Cette proposition a été validée sur modèles à l’aide de techniques analytiques, par simulation ainsi que grâce à des expérimentations. Notre deuxième objectif est d'étudier le problème de l'ordonnancement d'un ensemble de tâches temps réel réalisant chacune les algorithmes de contrôle dans une application centralisée évolutive. Nous proposons un mécanisme d'ordonnancement qui ajuste en ligne les contraintes (m,k)-firm des tâches suivant la configuration courante de l'application de manière à ce qu’un critère reflétant la performance globale de l'application soit optimal à tout instant / In this thesis, we study a coordinated approach for the design of control laws and scheduling parameters. The first objective is to propose and evaluate a technique to control the degradation of the quality of control (QoC) by selectively rejecting task or message instances according to the (m,k)-firm model. More specifically, we have studied the impact of the (m,k)-firm packet dropout policy on the QoC of a control loop. Based on the obtained results, we have specified a co-design method for determining the parameters (gain) of the optimal control law and the (m,k)-firm constraint specifying the selective rejet of instances. This proposal was validated by using analytical techniques, simulation and experimentation activities. The second objective is to address the scheduling problem of a set of real-time tasks where each task implements a control law in a centralized scalable application. We proposed a scheduling mechanism which determines on line, according to the current system configuration, a (m,k)-constraint based scheduling strategy to apply to each task so that the criterion reflecting the overall performance of the application is optimal at all times
2

Réseaux de Communication et Applications de Contrôle-Commande

Nguyen, Xuan Hung 15 December 2011 (has links) (PDF)
Cette thèse se situe dans le domaine des Systèmes Commandés en Réseaux, systèmes pluridisciplinaires qui connaissent un grand développement dans le contexte technologique actuel et qui introduisent de nouveaux problèmes de recherche, en particulier, pour les communautés Automatique et Réseau de Communication. L'objectif est de montrer l'intérêt de considérer un lien bidirectionnel entre la Qualité de Contrôle (QdC) (stabilité et performance des applications de contrôle-commande) et la Qualité de Service (QdS) (retards dans les transmissions) en se focalisant sur les réseaux locaux et plus particulièrement sur l'ordonnancement des trames dans la sous couche MAC où on considère des protocoles MAC de type CSMA. Notre travail se situe tout d'abord dans le cadre du réseau CAN où nous faisons trois propositions. La première proposition consiste en des solutions de QdS pour des applications de contrôle-commande sur la base du concept de priorité hybride, pour l'ordonnancement de trames, dans laquelle nous définissons une partie priorité dynamique qui dépend d'un paramètre de QdC. Ceci permet de réaliser une relation QdC->QdS. La deuxième proposition consiste en des solutions de QdC par une méthode de compensation de retard (maintenance des pôles dominants) ce qui permet de réaliser une relation QdS->QdC. La troisième proposition consiste à réaliser une relation QdC<=>QdS qui assure lors de l'implantation de plusieurs applications, une propriété d'équité comportementale. Nous abordons ensuite le cadre particulier des réseaux locaux sans fil où, d'une part, nous définissons des protocoles MAC de type CSMA sans collision sur la base de priorités et, d'autre part, nous montrons la faisabilité des idées développées dans le cadre du réseau CAN.
3

Proposition d'une approche intégrée basée sur les réseaux de Petri de haut niveau pour simuler et évaluer les systèmes contrôlés en réseau

Brahimi, Belynda 05 December 2007 (has links) (PDF)
L'étude des systèmes en réseau supports d'applications collaboratives, distribuées et interconnectées par un réseau repose sur l'identification des exigences de fonctionnement de l'application appelées Qualité de Contrôle (QdC), et sur l'évaluation des performances du réseau pour obtenir son niveau de Qualité de Service (QdS). « Cette thématique comporte d'importants verrous de nature fondamentale relevant du domaine de l'automatique, de la robotique, des capteurs, de la théorie de l'information, des réseaux. Par souci de simplification, les travaux sur les systèmes en réseau se repartissent selon deux approches: la première compense les perturbations générées par les communications au niveau de l'application (« control over network »). La seconde adapte les performances du réseau en fonction des besoins applicatifs (« control of network »). L'objectif de nos travaux de thèse est donc de proposer un environnement de modélisation intégré permettant de représenter le comportement des SCRs. Nous avons choisi les Réseaux de Petri de haut niveau qui possède un fort pouvoir d'expression, de formalisation et dont la modularité permet d'ajouter et/ou de faire évoluer les modèles qui sont développés dans ce travail. Dans un premier temps, nous avons proposé un modèle Ethernet Commuté gérant des mécanismes d'ordonnancement. Le choix de ce réseau a été guidé par le fait qu'il est de plus en plus utilisé dans les SCRs. Ensuite, le modèle d'un SCR a été proposé, et modélisé par des Réseaux de Petri de haut de niveau, en intégrant au modèle Ethernet Commuté, l'environnement applicatif : Contrôleur, Process,.. Enfin, des stratégies pour commander le réseau de façon à adapter sa Qualité de Service en regard de la Qualité de Contrôle requise par l'application, ont été mises en oeuvre. Pour cela, des ordonnanceurs à priorité stricte et de type WRR sont utilisés. Les résultats de simulation montrent clairement que des dispositifs de compensation du réseau pour améliorer les performances du système de communication, permettent aussi d'améliorer les performances du système à commander.
4

Réseaux de communication et applications de contrôle-commande / Communication Networks and Process Control Applications

Nguyen, Xuan hung 15 December 2011 (has links)
Cette thèse se situe dans le domaine des Systèmes Commandés en Réseaux, systèmes pluridisciplinairesqui connaissent un grand développement dans le contexte technologique actuel etqui introduisent de nouveaux problèmes de recherche, en particulier, pour les communautés Automatiqueet Réseau de Communication. L’objectif est de montrer l’intérêt de considérer un lienbidirectionnel entre la Qualité de Contrôle (QdC) (stabilité et performance des applications decontrôle-commande) et la Qualité de Service (QdS) (retards dans les transmissions) en se focalisantsur les réseaux locaux et plus particulièrement sur l’ordonnancement des trames dans la souscouche MAC où on considère des protocoles MAC de type CSMA.Notre travail se situe tout d’abord dans le cadre du réseau CAN où nous faisons trois propositions.La première proposition consiste en des solutions de QdS pour des applications decontrôle-commande sur la base du concept de priorité hybride, pour l’ordonnancement de trames,dans laquelle nous définissons une partie priorité dynamique qui dépend d’un paramètre de QdC.Ceci permet de réaliser une relation QdC→QdS. La deuxième proposition consiste en des solutionsde QdC par une méthode de compensation de retard (maintenance des pôles dominants)ce qui permet de réaliser une relation QdS→QdC. La troisième proposition consiste à réaliserune relation QdC⇋QdS qui assure lors de l’implantation de plusieurs applications, une propriétéd’équité comportementale. Nous abordons ensuite le cadre particulier des réseaux locaux sans filoù, d’une part, nous définissons des protocoles MAC de type CSMA sans collision sur la basede priorités et, d’autre part, nous montrons la faisabilité des idées développées dans le cadre duréseau CAN / This thesis is in the field of Networked Controlled Systems, which are multidisciplinary systemsand which experience a great development in the context of the current technology andintroduce new research problems, particularly for the communities of Automatic Control andCommunication Network. The aim is to show the interest in considering a bidirectional link betweenthe Quality of Control (QoC) (stability and performance of process control applications) andQuality of Service (QoS) (delays in the transmissions) and to focus on Local Area Networks and,more particularly, on the scheduling of frames in the MAC layer in which we consider CSMAMAC protocols.Our work first concerns a CAN network where we have three proposals. The first proposalconsists of solutions for QoS, for process control applications, which are based on the conceptof hybrid priority for the frame scheduling in which we define a dynamic priority part which dependson a QoC parameter. This allows to implement a relation QoC→QoS. The second proposalconsists of QoC solutions by using a compensation method for time delays (maintenance of dominantpoles) which allows to implement a relation QoS→QoC. The third proposal consists inimplementing a relation QoS⇋QoC that ensures, for the implementation of several applications,a fairness property. We then discuss the specific context of Wireless LANs, where, on the onehand, we define collision-free CSMA MAC protocols on the basis of priorities and, on the otherhand, we show the feasibility of the ideas developed in the CAN network
5

Assurance qualité des traitements par hadronthérapie carbone par imagerie de particules promptes chargées / Quality assurance for carbon hadrontherapy treatments with prompt charged particles imaging

Reithinger, Valérian 29 September 2015 (has links)
L'hadronthérapie est une modalité de radiothérapie innovante dans laquelle des ions légers -tels des protons ou des ions carbone- sont accélérés à une vitesse relativiste, puis focalisés afin d'irradier la zone tumorale du patient. Cette technique se démarque de la radiothérapie dite conventionnelle utilisant des photons- par l'existence d'un pic de dépôt d'énergie, appelé pic de Bragg, qui se situe à la fin du parcours des ions. L'existence de différents phénomènes qui aboutissent à une incertitude sur le parcours des ions représente toutefois une limite à la précision intrinsèque de cette modalité. Cela justifie la nécessité d'une assurance qualité des traitements et motive le développement de techniques de suivi en ligne et en temps réel du parcours des ions. Ces travaux de thèse ont pour objet la caractérisation d'une technique de suivi du parcours des ions, appelée imagerie des vertex d'interaction. Il a en effet été observé que lors du parcours des ions dans le patient, une fraction importante de ceux-ci subit des réactions nucléaires, à l'origine d'un rayonnement de particules promptes secondaires chargées. Un télescope constitué de capteurs pixélisés est proposé pour localiser les vertex d'interaction de ces particules et mesurer leur corrélation avec le parcours des ions, corrélation prédite par des travaux in-silico précédents. La réalisation de plusieurs expériences durant lesquelles des cibles homogènes et hétérogènes ont été irradiées dans des conditions réalistes a permis d'obtenir les premiers résultats expérimentaux relatifs à cette technique, confrontés à des simulations qui ont également été réalisées. Avant de discuter l'ensemble des résultats obtenus, ce manuscrit détaille les aspects matériels et logiciels des importants développements mis en oeuvre et qui ont abouti à un prototype complet et fonctionnel d'imageur, accompagné de simulations Monte Carlo basées sur le logiciel Geant4 / Hadrontherapy is an innovative radiotherapy modality in which light ions -such as protons or carbon ionsare accelerated to a relativistic speed and focused to irradiate a tumoral area. This technique differs from the conventional radiotherapy -which uses photons- by the existence of an energy deposition peak, called Bragg peak, which stands at the end of the ions path. However, different phenomena that lead to uncertainty in the real ion range exist, and limit the intrinsic accuracy of this modality. This justifies the need for a treatments quality assurance and motivates the development of in-line and real-time monitoring techniques to follow the real ions range. This PhD thesis work aims the characterization of an ion range monitoring technic, called interaction vertex imaging. It has been observed that during the ion path in the patient, a significant part of incoming ions undergoes nuclear reactions, causing a prompt secondary charged particles radiation. A telescope made up of pixelated sensors is proposed to locate these particles interaction vertex and to measure their correlation with the ions range, correlation predicted by a previous in-silico work. The first experimental results for this technique has been obtained with the realization of several experiments during which homogeneous and heterogeneous targets were irradiated under realistic conditions. Simulations were also performed to compare with experimental results. Before discussing the overall results, this manuscript details the hardware and software aspects of important developments that was made and that resulted in a complete and working prototype imager, with Monte Carlo simulations based on the Geant4 software
6

Mise en oeuvre d’un démonstrateur de caméra Compton pour l’imagerie en médecine nucléaire et pour le contrôle en temps réel de l’hadronthérapie à l’aide des rayonnements gamma prompts / Development of a time-of-flight Compton camera prototype for online control of ion therapy and medical imaging

Ley, Jean-Luc 14 December 2015 (has links)
L'hadronthérapie est l'une des modalités disponibles pour traiter le cancer. Cette modalité utilise des ions légers (protons, ions carbone) pour détruire les cellules cancéreuses. De telles particules ont une précision balistique de par leur trajectoire quasi-rectiligne, leur parcours fini et le profil de dose maximum en fin de parcours, ce qui permet, par rapport à la radiothérapie conventionnelle, d'épargner les tissus sains situés à côté, en aval et en amont de la tumeur. L'un des enjeux de l'assurance qualité de cette modalité est le contrôle du positionnement de la dose déposée par les ions dans le patient. Une possibilité pour effectuer ce contrôle est d'observer les gammas prompts émis lors des réactions nucléaires induites le long du parcours des ions dans le patient. Un prototype de caméra Compton, permettant théoriquement de maximiser l'efficacité de détection des gammas prompts, est actuellement développé dans une collaboration régionale. Mon travail de thèse s'est axé autour de cette caméra et plus particulièrement sur les points suivants : i) étudier par les simulations Monte Carlo le fonctionnement du prototype en cours de construction, notamment en regard des taux de comptage attendus sur les différents types d'accélérateurs en hadronthérapie, ii) mener des études de simulation sur l'utilisation de cette caméra en imagerie clinique, iii) caractériser les détecteurs silicium du diffuseur, iv) confronter les simulations entreprises sur la réponse de la caméra avec des mesures sur faisceau à l'aide d'un démonstrateur. Il résulte que le prototype de caméra Compton développé rend possible un contrôle de la localisation du dépôt de dose en protonthérapie à l'échelle d'un spot, à condition que l'intensité clinique du faisceau de protons soit diminuée d'un facteur 200 (intensité de 108 protons/s). Une application de la caméra Compton en médecine nucléaire semble réalisable avec l'utilisation de radioisotopes d'énergie supérieure à 300 keV. Ces premiers résultats doivent être confirmés par des simulations plus réalistes (cibles de PMMA homogènes et hétérogènes). Des tests avec l'intégration progressive de tous les éléments de la caméra vont avoir lieu courant 2016 / Hadrontherapy is one of the modalities available for treating cancer. This modality uses light ions (protons, carbon ions) to destroy cancer cells. Such particles have a ballistic accuracy thanks to their quasi-rectilinear trajectory, their path and the finished profile maximum dose in the end. Compared to conventional radiotherapy, this allows to spare the healthy tissue located adjacent downstream and upstream of the tumor. One of this modality’s quality assurance challenges is to control the positioning of the dose deposited by ions in the patient. One possibility to perform this control is to detect the prompt gammas emitted during nuclear reactions induced along the ion path in the patient. A Compton camera prototype, theoretically allowing to maximize the detection efficiency of the prompt gammas, is being developed under a regional collaboration. This camera was the main focus of my thesis, and particularly the following points : i) studying, throughout Monte Carlo simulations, the operation of the prototype in construction, particularly with respect to the expected counting rates on the different types of accelerators in hadrontherapy ii) conducting simulation studies on the use of this camera in clinical imaging, iii) characterising the silicon detectors (scatterer) iv) confronting Geant4 simulations on the camera’s response with measurements on the beam with the help of a demonstrator. As a result, the Compton camera prototype developed makes a control of the localization of the dose deposition in proton therapy to the scale of a spot possible, provided that the intensity of the clinical proton beam is reduced by a factor 200 (intensity of 108 protons / s). An application of the Compton camera in nuclear medicine seems to be attainable with the use of radioisotopes of an energy greater than 300 keV. These initial results must be confirmed by more realistic simulations (homogeneous and heterogeneous PMMA targets). Tests with the progressive integration of all camera elements will take place during 2016

Page generated in 0.0704 seconds