• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 362
  • 173
  • 26
  • Tagged with
  • 552
  • 552
  • 351
  • 321
  • 314
  • 312
  • 211
  • 202
  • 95
  • 94
  • 90
  • 79
  • 74
  • 67
  • 61
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Régions cérébrales impliquées dans l'encodage mnésique de la douleur

Auclair, Vincent January 2016 (has links)
Le rappel d'une douleur passée est souvent utilisé par les professionnels de la santé afin d'évaluer la progression d'une douleur clinique et l'efficacité des moyens mis en place pour la traiter. Hors, le rappel d'une douleur est rarement précis et ceci représente une entrave majeure au processus décisionnel du traitement de la douleur clinique. À ce jour, on ignore toujours les mécanismes neuronaux engagés dans la formation de la mémoire d'une douleur et ceci est regrettable puisqu'aucune disposition ne peut être prise pour favoriser le rappel précis de la douleur. Il est aujourd'hui bien documenté que les mécanismes cérébraux engagés au moment de l'encodage mnésique sont essentiels dans la formation de la mémoire à long terme. En se basant sur ces résultats, nous avons postulé que l'activité cérébrale engagée au moment de l'encodage d'une douleur pourrait permettre de prédire la précision du rappel à long terme de cette douleur. Des stimulations électriques transcutanées, provoquant des sensations non-douloureuses et douloureuses, ont été administrées chez 21 participants en santé tout en procédant à l'enregistrement de leur activité cérébrale par la technique d'imagerie par résonance magnétique fonctionnelle (IRMf). Le rappel de la douleur a été évalué deux mois plus tard. La différence entre le rappel de la douleur et l'intensité de la douleur a constitué la variable dépendante principale, soit le score de précision du rappel de la douleur (PRD). Ces scores ont été rectifiés, de façon à ce que de faibles scores représentent un rappel précis de la douleur et de hauts scores représentent un rappel imprécis de la douleur. La douleur expérimentale a provoqué l'activation des régions classiquement associées au traitement et à la perception de la douleur, soit les cortex somatosensoriels primaires et secondaires, le cortex insulaire, le thalamus, le cortex cingulé antérieur et le cervelet (Z > 2.4, p < 0.05). L'analyse corrélationnelle principale a démontré que les scores de PRD étaient significativement et négativement associés à l'activité de l'insula dorso-antérieure gauche à l'encodage (r = -0.7549, p < 0.05 après correction pour mesures répétées). Aucune association similaire n'a été observée pour les stimulations électriques non-douloureuses. L'insula dorso-antérieure est traditionnellement associée à la saillance émotionnelle, l'interoception et la pertinence personnelle relative à une expérience. Puisque la précision du rappel est associée l'activité insulaire et qu'il a été démontré que le rappel d'un évènement qui nous concerne personnellement est plus précis, il est possible que le rappel d'une douleur passée soit plus précis lorsque la sensation ou le contexte a une importante signification émotionnelle ou personnelle.
2

Mesure de performance de l'angiographie par résonance magnétique pour diagnostiquer les résidus anévrismaux après une embolisation cérébrale

Lavoie, Pascale January 2011 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdoctorales, 2011-2012 / Cette étude visait à estimer les mesures de performance de l'angiographie par résonance magnétique (ARM) pour diagnostiquer un résidu anévrismal après une embolisation cérébrale. Les patients suivis dans notre centre pour au moins un anévrisme cérébral ont été recrutés pour passer une ARM et une angiographie par soustraction digitale (ASD) le même jour. Les mesures de performance de l'ARM ont été estimées dans une analyse transversale, et avec un devis longitudinal pour les valeurs prédictives, à partir de 167 images d'anévrismes embolisés obtenues pour chaque examen. La sensibilité et la spécificité de l'ARM pour le diagnostic de tout résidu étaient de 88% [IC95% : 80-94] et de 79% [IC95%: 67-88] respectivement. La valeur prédictive positive pour une récidive de classe 3 était de 67% [IC95% : 51-80] et la valeur prédictive négative de 93% [IC95% : 86-97]. La sensibilité de l'ARM pour un résidu de classe 3 était inférieur pour les petits anévrismes de moins de 6 mm que pour les plus grands. En conclusion, la performance de l'ARM est adéquate pour dépister un résidu anévrismal après une embolisation. En raison de sa plus faible valeur prédictive négative, les récidives anévrismales devraient être confirmées avec une ASD avant de planifier un retraitement. L'ARM ne devrait être utilisée de routine pour les petits anévrismes que lorsqu'une meilleure estimation de ses mesures de performance dans ce sous-groupe aura été obtenue.
3

Segmentation automatisée du ventricule gauche en IRM cardiaque : Evaluation supervisée et non supervisée de cette approche et application à l'étude de la viabilité myocardique / Automated segmentation of the left ventricle in cardiac MRI : supervised and non-supervised evaluation of this approach and application to the study of the myocardial viability

Constantinides, Constantin 10 July 2012 (has links)
Cette thèse a pour objectif de parvenir à une estimation automatisée des contours du ventricule gauche sur des images IRM en coupes petit-axe, nécessitant un minimum d’interventions de la part de l’utilisateur. En s’appuyant sur une approche semi-automatique récemment développée, une méthode entièrement automatique est proposée, reposant sur la localisation des structures cardiaques et la création d’une région d’intérêt autour du ventricule gauche, puis la segmentation de sa cavité. L’algorithme a été développé en prenant en compte des connaissances anatomiques et fonctionnelles sur le cœur : les caractéristiques temporelles du battement cardiaque, la pseudo-circularité des coupes petit-axe du ventricule gauche, la continuité 3D qui ont été combinées à l’intensité dans les images. La segmentation utilise une approche fondée sur les contours actifs combinée à un filtrage morphologique qui améliore la robustesse de la segmentation vis-à-vis des hétérogénéités au sein de la cavité. Le travail réalisé avec le groupe MedIEval (MedicalImaging Evaluation) a permis de comparer les deux méthodes avec 6 autres méthodes, dont 3 tracés d'experts. Une classification par une approche d’évaluation sans référence a été appliquée à la fraction d’éjection estimée par les 8 méthodes. Enfin, la méthode de segmentation proposée a été utilisée systématiquement dans une étude de recherche clinique combinant l’étude de la contraction régionale et la quantification de la transmuralité de l’infarctus du myocarde. Ces travaux ouvrent des perspectives, sur l’automatisation de la segmentation du ventricule droit et l’estimation d’une forme mutuelle robuste à partir de plusieurs segmentations. / The aim of this work is to perform an automated segmentation of the Left Ventricle on short-axis cardiac MR images with as few user interactions as possible. Based on a recently developed semi-automated segmentation method, a fully automated segmentation method is proposed that includes three main steps: the heart localization, the definition of a region of interest around the left ventricle, and finally its segmentation. The algorithm developed here takes into account anatomic and functional a priori information such as the temporal features of the heartbeat, the pseudo-circular shape of the LV, and the 3D continuity, combined with the image intensity features. The segmentation process is achieved using deformable models combined with morphological filters, which improve the model performances when dealing with heterogeneous gray levels within the cavity. The work achieved within the MedIEval group (Medical Imaging Evaluation) allowed to compare both proposed methods with 6 other methods, including 3 manual delineations by experts. In particular, an approach for ranking segmentation methods without using a gold standard was applied to the ejection fractions estimated by the 8 methods. Finally, the proposed segmentation method was used in a clinical research work about the regional contraction and thequantification of the myocardial infarction extent.Future work includes the automated segmentation of the right ventricle as well as the estimation of a robust mutual shape from several segmentation methods.
4

Using MRI physics and AI for multi-parametric MRI-guided radiotherapy

Safari, Mojtaba, Safari, Mojtaba 11 March 2024 (has links)
Thèse ou mémoire avec insertion d'articles / L'objectif principal de cette thèse est d'explorer les applications de l'imagerie par résonance magnétique multiparamétrique (IRMmp) en radio-oncologie. Les images IRM sont utilisées à différentes étapes de la radiothérapie, notamment la planification, le guidage et le suivi. L'étape de planification utilise généralement le contraste des tissus mous de l'IRM ou des images physiologiques pour délimiter les cibles. L'étape de guidage utilise le contraste des tissus mous de l'IRM pour guider les traitements de radiothérapie. L'IRM quantitative (qMRI) et l'IRMmp sont utilisées pour évaluer une réponse au traitement. Cette thèse vise à utiliser les cartes qMRI pour quantifier la réponse des tissus de la tête et du cou à l'oxygénation, réduire les artefacts et les distorsions de l'IRM, et enfin fusionner l'IRM et la tomodensitométrie (TDM). Un des objectif est d'optimiser les cartes qMRI incluant T₁ et R₂* pour quantifier la préservation de l'oxygène après avoir administré de l'oxygène pur (pO₂) aux volontaires sains. Cette étude était la première in vivo quantifiant la préservation de l'oxygène dans les tissus de la tête et du cou après l'administration de pO₂. Deux expériences distinctes ont été réalisées : (1) délivrer une oxygénation normobare (NBO) et comparer les cartes qMRI en série T₁ et R₂* acquises pendant et après la NBO avec la ligne de base (avant de délivrer la NBO), et (2 ) délivrant une oxygénation hyperbare (HBO) et comparant les cartes qMRI en série T₁ et R₂* acquises après HBO avec la ligne de base (avant de délivrer HBO). Nous avons réalisé que le niveau d'oxygène de la glande parotide et du muscle masséter augmentait de manière significative (*p* < 0,05) après l'administration du NBO pendant 15 minutes et revenait à la valeur de base environ sept minutes après le NBO. Dans l'expérience HBO, une tendance similaire a été observée. Nous n'avons pas trouvé de différence entre les images qMRI de base et post-HBO. Ensuite, le travail s'est concentrée sur les distorsions et les artefacts de l'IRM. Dans cette étude, nous avons proposé un modèle d'apprentissage profond pour prédire les distorsions géométriques spécifiques aux patients (PSgD) causées par les différences de susceptibilité entre deux tissus. Ensuite, le T₁w (ceT₁w) amélioré en contraste a été corrigé pour le PSgD. Nous avons formé notre modèle d'apprentissage profond (DL) à l'aide d'un ensemble de données de 380 sujets. Nous avons comparé les distributions de doses de radiochirurgie stéréotaxique Gamma Knife (GK-SRS) pour les patients atteints de schwannome vestibulaire, calculées à l'aide d'images corrigées et corrompues par le PSgD. Nous avons constaté qu'en moyenne D$_μ$, D$_\textup{95\%}$ et D$_\textup{min}$ en Gy ont augmenté de manière significative après correction PSgD de 16,85 à 17,25, 12,30 à 12,77 et de 8,98 à 9,92. La couverture moyenne des objectifs et l'indice de conformité de Paddick ont considérablement augmenté, passant de 0,97 à 0,98 et de 0,94 à 0,96. L'indice de gradient de Paddick moyen a diminué de manière significative, passant de 2,24 à 2,15 après correction du PSgD. Les troisième et quatrième études visaient à réduire les artefacts de mouvement de l'IRM à l'aide de nouveaux modèles génératifs. Les deux études ont été formées et testées auprès de 230 patients postopératoires. De plus, un ensemble de données de 148 patients présentant des artefacts de mouvement réels a été utilisé pour valider notre modèle afin de supprimer les artefacts de mouvement réels. Cette troisième étude a exploité la T₂ fluid-attenuated inversion recovery pour former un modèle génératif non supervisé permettant de supprimer les artefacts de mouvement ceT₁w. Nous avons comparé notre modèle avec deux modèles génératifs bien connus. Nous avons également réalisé une étude d'ablation pour évaluer différentes variantes de notre modèle proposé. Notre modèle a mieux performé quantitativement et qualitativement par rapport aux autres modèles. Dans la quatrième étude, nous avons utilisé un modèle probabiliste de diffusion conditionnelle stable pour supprimer les artefacts de mouvement ceT₁w. Cette étude a proposé une nouvelle méthode pour simuler le modèle de diffusion directe dans l'espace *k*, permettant la génération d'ensembles de données in silico avec différents niveaux d'artefacts de mouvement. Notre méthode a surpassé quantitativement et qualitativement deux modèles génératifs et un modèle supervisé. Le dernier volet a proposé une méthode non supervisée pour fusionner la tomodensitométrie et l'IRM, car elles fournissent des informations complémentaires pour la planification de la radiothérapie. Les images TDM sont géométriquement corrigées et fournissent des informations sur la densité électronique pour un calcul précis de la dose et l'IRM fournit des images avec un excellent contraste des tissus mous. Cette étude a proposé un modèle génératif de fusion médicale non supervisé pour fusionner la tomodensitométrie et le ceT₁w haute résolution afin de générer une image avec la structure osseuse de la tomodensitométrie et le contraste des tissus mous de l'IRM. Ainsi, la délimitation des tumeurs et des organes à risque sera améliorée et le temps de planification de la radiothérapie sera réduit. Les résultats de notre méthode ont été comparés quantitativement et qualitativement à sept méthodes traditionnelles et à huit méthodes de pointe DL, où notre méthode les a toutes surpassées. / The main goal of this thesis is to explore multi-parametric magnetic resonance imaging (mpMRI) applications in radiation oncology. MRI images are used in different stages of the treatments including planning, guiding, and following up. The planning step usually utilizes MRI soft-tissue contrast or physiological images to delineate targets. The guiding step uses MRI soft-tissue contrast to guide radiation treatments. Quantitative MRI (qMRI) and mpMRI are used to evaluate a response to the treatment. This thesis aimed to use qMRI maps to quantify head and neck tissues' response to oxygenation, reduce MRI artifacts and distortions, and finally fuse MRI and computed tomography (CT). This thesis was started to optimize qMRI maps including T₁ and R₂* to quantify oxygen preservation after delivering pure oxygen (pO₂) to the healthy volunteers. This study was the first in vivo quantifying head and neck tissue oxygen preservation after delivering pO₂ . Two separate experiments were carried out : (1) delivering normobaric oxygenation (NBO) and comparing serial qMRI T₁ and R₂* maps acquired during and after NBO with the baseline (before delivering NBO), and (2) delivering hyperbaric oxygenation (HBO) and comparing the serial qMRI T₁ and R₂* maps acquired after HBO with the baseline (before delivering HBO). We realized that the parotid gland and masseter muscle oxygen level increased significantly (*p* < 0.05) after delivering NBO for 15 minutes and returned to the baseline around seven minutes after the NBO. In the HBO experiment, a similar trend was observed. We did not find a difference between baseline and post-HBO qMRI images. Then, our thesis concentrated on the MRI distortions and artifacts. In the second study, we proposed a deep learning model to predict MRI patient-specific geometry distortions (PSgD) caused by susceptibility differences between two tissues. Then, the contrast-enhanced T₁W (ceT₁W) was corrected for the PSgD. We trained our deep learning (DL) model using a dataset of 380 subjects. We compared the Gamma Knife stereotactic radiosurgery (GK-SRS) dose distributions for the patients with vestibular schwannoma calculated using PSgD-corrected and PSgD-corrupted images. We found that on average D$_μ$, D$_\textup{95\%}$ et D$_\textup{min}$ in Gy significantly increased after PSgD correction from 16.85 to 17.25, 12.30 to 12.77, and from 8.98 to 9.92. Average target coverage and Paddick's conformity index significantly increased from 0.97 to 0.98, and 0.94 to 0.96. Average Paddick's gradient index decreased significantly from 2.24 to 2.15 after PSgD correction. The third and fourth studies aimed to reduce MRI motion artifacts using novel generative models. Both studies were trained and tested using post-surgery 230 patients. In addition, a dataset of 148 patients with real motion artifacts was used to validate our model to remove real motion artifacts. The third study leveraged T₂-fluid-attenuated inversion recovery to train an unsupervised generative model for removing ceT₁W motion artifacts. We compared our model with two well-known generative models. Also, we performed an ablation study to evaluate different variations of our proposed model. Our model outperformed quantitatively and qualitatively other models. In the fourth study, we used a stable conditional diffusion probabilistic model to remove ceT₁W motion artifacts. This study proposed a novel method for simulating the forward diffusion model in *k*-space, enabling the generation of in-silico datasets with varying levels of motion artifacts. Our method quantitatively and qualitatively outperformed two generative models and one supervised model. The fifth study proposed an unsupervised method to fuse CT and MRI because they provide complementary information for radiation therapy planning. CT images are geometrically corrected and provide electron density information for accurate dose calculation and MRI provides images with excellent soft-tissue contrast. This study proposed an end-to-end unsupervised medical fusion generative model to fuse CT and high-resolution ceT₁W to generate an image with CT bone structure and MRI soft-tissue contrast. Thus, tumor and organs at risk delineation will be improved and the radiotherapy planning time will be reduced. The results of our method were quantitatively and qualitatively compared with seven traditional and eight DL state-of-the-art methods where our method outperformed the traditional and DL approaches.
5

Rôle clinique de l'imagerie par résonance magnétique pour le pronostic de sujets avec troubles cognitifs légers : stratification selon le fonctionnement cognitif global

Bodryzlova, Yuliya 23 April 2018 (has links)
Introduction : La valeur prédictive de la volumétrie cérébrale par imagerie par résonance magnétique (IRM) pour le pronostic de progression des individus avec trouble cognitif léger amnésique (TCLa) vers la maladie d’Alzheimer est généralement rapportée comme étant hors des barèmes requis pour l’implémentation de tests diagnostiques dans la pratique courante (rapport de vraisemblance positif (LR+) >= 5.0 et négatif (LR-) <= 0.2). Par contre, aucune recherche à ce jour n’a évalué cette valeur prédictive en utilisant une stratégie de stratification prenant en considération leur état cognitif global, comme indice de progression de la maladie. Objectif : Estimer la valeur pronostique de l’IRM chez les TCLa ayant un fonctionnement cognitif global préservé, défini par une cote au Mini-Mental State Examination entre 28 et 30. Méthodes : Une étude de cohorte rétrospective portant sur 147 TCLa avec fonctionnement global préservé a été effectuée à partir de la base de données de l’Alzheimer’s Disease Neuroimaging Initiative. Nous avons créé un modèle prédictif pour la progression du TCLa sur un suivi de 36 mois à partir de variables volumétriques en IRM et d’informations cliniques et sociodémographiques accessibles en première ligne. Résultats : Le meilleur modèle inclut le volume de l’hippocampe gauche, l’épaisseur corticale du lobe temporal médian, le volume intracrânien, l’âge et le sexe. L’aire sous la courbe ROC est de 91.1%; l’exactitude de classification est de 81.9%, la sensibilité est de 71.4% et la spécificité est de 85.3% (LR + = 4.9 and LR- = 0.3.) Conclusion : La prédiction obtenue par le modèle pour les sujets avec fonctionnement cognitif préservé est meilleure que celle rapportée par les études précédentes, et atteint le seuil d’utilité clinique.
6

Trabeculated myocardium in healthy adults : a first step in understanding the diagnosis of non-compaction cardiomyopathy by magnetic resonance

Tizón-Marcos, Helena 19 April 2018 (has links)
La cardiomyopathie non-compacté (NCC) est une maladie rare avec des critères diagnostiques basés sur la détection de l’augmentation du myocarde trabeculé par échocardiographie. L’imagerie par résonance magnétique (IRM) est devenue la méthode de référence pour étudier la fonction et la morphologie du cœur compte tenu de sa meilleure résolution spatiale et temporale. Toutefois, les critères diagnostiques de NCC que nous utilisons en ce moment en IRM ont été tirés d’études en échocardiographie. Ceci pourrait impliquer une augmentation de l’incidence de nouveaux cas de NCC, de même que la positivité chez les adultes en santé. Le présent travail a voulu étudier la “normalité” par IRM en termes de présence et de distribution de myocarde trabeculé chez les adultes en santé et déterminer la présence des associations entre le myocarde trabeculé et les paramètres de fonction cardiaque. / Non-compaction cardiomyopathy (NCC) is a rare entity that is currently diagnosed for the most part by echocardiography in cases of an increased layer of trabeculated myocardium. Recently, magnetic resonance imaging (MRI) became the gold standard imaging technique in the study of cardiac function and morphology due to its high spatial and temporal resolution. However, diagnostic NCC criteria developped for echocardiography have been directly applied to MRI in the abscence of a standard definition of trabeculated myocardium. This direct application of echocardiography criteria to MRI may have led to an increased incidence of new NCC cases. The aim of this present work is to clarify clinical practice by determining normality by MRI in terms of presence and distribution of trabeculated myocardium in healthy adults and determine if any association exist between the presence and extension of trabeculated myocardium and cardiac function.
7

Couplage de l'acquisition compressée et de l'imagerie du spectre de diffusion

Saint-Amant, Etienne January 2011 (has links)
Ce mémoire porte sur la croisée des chemins de deux technologies récentes et fascinantes : l'imagerie du spectre de diffusion et l'acquisition compressée. L'imagerie du spectre de diffusion est issue de l'imagerie par résonance magnétique nucléaire. Elle permet d'observer la façon dont les molécules d'eau se déplacent dans le cerveau. Les molécules d'eau sont contraintes par la riche géométrie cellulaire des tissus cérébraux et les caractéristiques les plus probantes de cette géométrie peuvent être observées. En particulier, la diffusion est intimement liée à l'aspect fibreux de la matière blanche. L'information angulaire et l'information radiale de la matière blanche peuvent être déduites mathématiquement en analysant le signal du spectre de diffusion. À l'aide de ces informations, nous pouvons reconstruire le réseau de matière blanche du cerveau d'un patient (par tractographie) et en analyser l'intégrité (taille d'axone, démyélinisation, mort axonale). Cependant, la précision d'une technologie apporte souvent un défaut : son temps d'acquisition en tunnel IRM est prohibitif. L'acquisition compressée est une technologie récente, riche et complexe, issue de nombreuses branches différentes des mathématiques. Cette technologie peut s'appliquer sur l'acquisition de tous les types de signaux ou images. L'idée est d'acquérir de façon partielle les données et de résoudre un problème mathématique pour déduire quelle serait l'information complète (on déduit les données non mesurées). L'entièreté de cette technologie repose sur le principe fondamental suivant : les signaux/images d'intérêt ont la propriété d'être compressibles dans certaines bases de représentations. Cette technologie est particulièrement intéressante quand le temps d'acquisition est crucial ou que le nombre de mesures d'acquisition se doit d'être limité. Le sujet central de ce mémoire est de combiner l'acquisition compressée à l'imagerie du spectre de diffusion pour accélérer l'examen en tunnel IRM. Pour ce faire, nous avons développé une plate-forme informatique nous permettant d'analyser et de caractériser le couplage de ces deux technologies. Nous testons en détail nos méthodes sur des données générées synthétiquement et sur des données naturelles cérébrales in vivo. Finalement, nous proposons une méthode d'acquisition qui ferait passer le temps d'acquisition de 105 minutes à 29 minutes sans trop de perte perceptuelle par rapport à l'imagerie du spectre de diffusion acquise de façon exhaustive. Nous concluons avec un ensemble de pistes de solution pour pousser encore plus loin l'accélération de l'acquisition.
8

Etude par calorimétrie à titrage isotherme (ITC) et spectroscopie de résonance magnétique nucléaire (RMN) des équilibres de protonation liés à l'interaction entre l'alpha-chymotrypsine et la proflavine

Bruylants, Gilles 16 December 2005 (has links)
Le nombre de cibles potentielles pour la conception de nouvelles molécules à activité thérapeutique ne cesse de croître. Pour chaque cible, il est nécessaire d’identifier des molécules actives et de les optimiser afin d’atteindre l’affinité et la sélectivité recherchées. Ces nouveaux défis accentuent la nécessité d’améliorer notre compréhension des facteurs qui mènent à la reconnaissance moléculaire entre une drogue potentielle et une macromolécule biologique, et particulièrement des facteurs énergétiques à la base de la stabilisation d’un complexe d’interaction. Dans le cadre de ce travail, nous nous sommes intéressés à l’effet que pouvaient avoir les équilibres de protonation/déprotonation des résidus ionisables d’une protéine sur les paramètres thermodynamiques caractérisant la complexation d’un ligand. Dasns ce but, nous avons étudié l’interaction entre l’α-chymotrypsine et un de ses inhibiteurs compétitifs, la proflavine. Cette protéine est représentative d’un nombre important d’enzymes présentant le même mécanisme catalytique. La compréhension des facteurs qui régissent les équilibres de protonation/déprotonation des résidus ionisables présents dans son site actif ainsi que de l’effet sur ceux-ci de l’interaction avec des ligands est d’une importance primordiale pour le développement d’inhibiteurs plus sélectifs de ces protéases. Cette étude s’est essentiellement composée de trois volets. (i) La réalisation d’un modèle du complexe d’interaction afin de confronter des données structurales aux données expérimentales recueillies. (ii) L’étude de l’interaction entre l’α-chymotrypsine et la proflavine par spectroscopie de Résonance Magnétique Nucléaire (RMN) afin de mettre en évidence les résidus ionisables dont les équilibres de protonation/déprotonation sont influencés par la complexation du ligand. (iii) L’étude de la thermodynamique de l’interaction par Calorimétrie à Titrage Isotherme (ITC) et spectroscopie d’absorption en fonction de l’état d’ionisation des résidus identifiés par l’étude RMN. Le modèle du complexe d’interaction entre l’α-chymotrypsine et la proflavine a été réalisé sur base de la structure cristallographique du complexe entre cet inhibiteur et une protéase apparentée à la chymotrypsine, la thrombine. Il ressort de l’analyse du modèle obtenu que la proflavine est profondément enfouie dans le subsite S1 de l’enzyme et présente une très grande complémentarité de surface avec cette poche hydrophobe. Nous avons également pu constater la présence de plusieurs molécules d’eau immobilisées au sein du complexe, et d’une molécule en particulier faisant office de relais de liens-H. L’étude de l’interaction entre l’α-chymotrypsine et la proflavine par RMN du 1H a été précédée par une étude de l’effet du degré de maturité de l’enzyme sur les interactions liant les différents résidus composant la triade catalytique (Asp102, His57 et Ser195). Lors de l’activation du précurseur inactif de l’enzyme, le chymotrypsinogène, vers la forme mature, l’α-chymotrypsine, il semble en effet que le lien-H entre le NHε2 de l’His57 et le Oγ de la Ser195 soit affaibli, contrairement à celui qui relie le NHδ1 de cette même histidine au Oδ1 de l’Asp102. Nous rapportons pour la première fois l’observation de l’influence de la protonation de l’Asp102 sur les déplacements chimiques des protons NHδ1 et NHε2 de l’His57. L’étude de l’interaction entre l’α-chymotrypsine et la proflavine par RMN, nous a permis de mettre en évidence l’effet de la complexation du ligand sur l’état d’ionisation des résidus His57 et Asp102 de la triade catalytique, les pKa de ces résidus dans l’enzyme libre valant respectivement 7 et approximativement 4. Les paramètres thermodynamiques de l’interaction α-chymotrypsine - proflavine et des différents équilibres de protonation/déprotonation qui y sont liés ont été obtenus par spectroscopie d’absorption et ITC. Cette dernière technique constitue un outil précieux pour l’étude d’interactions moléculaires car il s’agit de la seule technique expérimentale permettant la mesure directe de l’enthalpie d’interaction. Lorsque des équilibres de protonation/déprotonation sont thermodynamiquement liés à l’interaction, il s’agit également de la seule technique permettant la quantification de ces effets. En mesurant la constante d’affinité et l’enthalpie d’interaction observées à différents pH et dans différents tampons, nous avons pu, sur base du modèle obtenu par RMN, déterminer les paramètres thermodynamiques intrinsèques des différents équilibres. La corrélation entre les données thermodynamiques obtenues par ITC et spectroscopie d’absorption et les données structurales obtenues par RMN et sur base de l’analyse du modèle du complexe d’interaction, nous a permis de rationaliser les facteurs à la base de l’interaction préférentielle de l’inhibiteur avec une des formes de l’enzyme. L’interaction entre l’α-chymotrypsine et la proflavine est la plus favorable lorsqu’à la fois l’His57 et l’Asp102 sont déprotonnés. Cette interaction est caractérisée par un terme enthalpique favorable et un terme entropique légèrement défavorable. Ce dernier terme s’expliquerait en partie par l’immobilisation dans le site d’interaction de plusieurs molécules d’eau. L’affinité entre l’α-chymotrypsine et la proflavine diminue lorsque l’His57 se protonne. La répulsion électrostatique entre les charges positives de la proflavine et de l’His57 est vraisemblablement un des facteurs permettant d’expliquer cette diminution de la constante d’affinité. Nous n’avons pu mettre en évidence d’interaction entre ces deux molécules dès lors que l’Asp102 est protonné, malgré que ce résidu soit situé relativement loin de la proflavine dans le complexe. Il s’agit donc d’un effet indirect, probablement relayé par l’His57. Tant que l’Asp102 est déprotonné, sa charge négative compenserait la charge positive de l’His57 et réduirait la répulsion électrostatique avec la proflavine, ce qui n’est plus le cas lorsque l’aspartate se protonne.
9

Études cognitive et neuroanatomique fonctionnelle des hallucinations auditives dans la schizophrénie

Ait Bentaleb, Lahcen January 2003 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
10

Mécanisme de ciblage des prohormones convertases vers les granules de sécrétion denses

Dikeakos, Dimitrios January 2008 (has links)
Thèse diffusée initialement dans le cadre d'un projet pilote des Presses de l'Université de Montréal/Centre d'édition numérique UdeM (1997-2008) avec l'autorisation de l'auteur.

Page generated in 0.0665 seconds