• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An Evaluation of Kilo Voltage Image Quality Produced by an On-Board Imager System

Mobini, Tina January 2015 (has links)
Syfte: Syftet med detta projekt var att utvärdera kvaliteten på de digitala röntgenbilder som genereras med en On-Board imager® (OBI), monterad på en medicinsk linjäraccelerator på radioterapiavdelningen på Karolinska Universitetssjukhuset. Dessa kilovoltbilder används för att verifiera patientens position på behandlingsbordet, inför behandling, för att reducera risken att friskvävnad bestrålas i onödan. Detta utförs genom en online ortogonal 2D-2D matchningsteknik innan strålningen leveras. Material och metoder: OBI-system, utvecklad av Varian Medical System, erbjuder en protokoll med exponeringsparametrar för att hjälpa användaren att välja lämpliga inställningar för exempelvis lämplig rörström och spänning under bildtagningen de digitala kilovoltbilderna. Under detta projekt skapades flera testbilder tagna med ändrade exponeringsparametrarna i de befintliga protokollen. Dessa testbilders kontrast bedömdes sedan och jämfördes med bilder tagna med de förinställda parametrar från Varians protokoll. Resultat och slutsats: En utvärdering av de experimentella testbilderna, i jämförelse med bilder skapade med det befintliga protokollet, visade att en justering av exponeringsfaktorer inte leder till något signifikant förbättring av bildernas kontrast. / Purpose: The purpose of this project was to evaluate the quality of kilo Voltage- digital radiography images that are provided by an On-Board imager® (OBI) mounted on a medical linear accelerator at the Radiotherapy department of Karolinska University Hospital. The digital kV-images are used to verify patient position on the treatment table, in order to reduce healthy tissue irradiation, using an online orthogonal set of 2D-2D matching technique, before the treatment delivery. Material and methods: The OBI- system elaborated by Varian Medical System offers an exposure factor protocol in order to help users to choice proper exposure factors, as proper tube current and tube voltage, during acquisition of kV-images. In this project several test images were performed by changing the exposure factors. Further the test images quality regarding, quality index contrast, was assessed and compared with the image performed by the existent Varian protocol. Result and Conclusion: Evaluation of the tests images shows that changing of the exposure factors doesn’t result in any significant improvement of kV-images contrast as compared to images created with the existent protocols parameters.
2

Evaluation of the Impact of X-ray Tube Voltage and Filter Thickness on the Performance of Spectral Photon-Counting Detectors / Utvärdering av inverkan av röntgenrörsspänning och filtertjocklek på prestanda för spektrala fotonräknande detektorer

Mannila, Cassandra, Larsson, Marcus January 2021 (has links)
During the past years photon-counting detectors (PCDs) have emerged as an alternative to conventional energy-integrating detectors and may significantly improve the standard of care for computed tomography (CT). There are two main alternatives for the material of the detector: cadmium telluride (CdTe) and silicon (Si). The settings of the X-ray tube and the applied filters need to be evaluated and optimized for the new detector technology. In this report, Monte Carlo simulations are used to determine how image quality is affected by different X-ray tube voltages and filter thicknesses. The image quality indicators that were chosen to evaluate are detective quantum efficiency (DQE) for material quantification and both DQE and dose-normalized signal-difference-to-noise ratio (SDNR) for detection tasks. Overall, silicon-based detectors performed better than cadmium-based detectors for quantification imaging tasks for all object thicknesses, while cadmium-based detectors were superior for detection imaging tasks in larger patients. For both silicon- and cadmium-based detectors, the dose-normalized image quality was largely independent of filter thickness, while the X-ray tube voltage had a more distinct impact on the result, where low voltages were optimal. / Under de senaste åren har fotonräknande detektorer blivit aktuellt som ett alternativ till konventionella energiintegrerande detektorer och kommer troligen förbättra datortomografibilder avsevärt. För de nya detektorerna finns det två huvudsakliga materialalternativ: kadmiumtellurid (CdTe) och kisel (Si). Inställningarna för röntgenröret och det pålagda filtret behöver utvärderas och optimeras för den nya detektorteknologin. I denna rapport användes Monte Carlo-simuleringar för att bestämma hur bildkvaliteten påverkades av rörspänningen och filtertjockleken. Bildkvaliteten bestämdes sedan utifrån tre indikatorer, detective quantum efficiency (DQE) för materialbestämning samt både DQE och dosnormaliserad signal-difference-to-noise ratio (SDNR) för detektionsuppgifter.    Den kiselbaserade detektorn presterade bättre än den kadmiumbaserade för materialbestämning för alla patientstorlekar medan den kadmiumbaserade presterade bättre på detektionsuppgifterna för större patienter. Vidare var den dosnormaliserade bildkvaliteten för både kisel- och kadmiumdetektorer svagt beroende av filtertjocklek medan båda påverkades starkt av rörspänningen, där låga spänningar var att föredra.

Page generated in 0.0645 seconds