• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • Tagged with
  • 337
  • 337
  • 145
  • 87
  • 71
  • 56
  • 55
  • 52
  • 42
  • 40
  • 40
  • 39
  • 39
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Determinacao das zonas de seguranca da central nuclear de Angra dos Reis conforme o modelo de difusao de radiacao na atmosfera

DELLA SANTINA, MURILO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:24:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:13Z (GMT). No. of bitstreams: 1 00376.pdf: 2599179 bytes, checksum: c0a89c9bf1cb4f69498ed0fb9b039e9d (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
172

Implementacao e aceite de sistema de radioterapia de feixe modulado dinamico com o uso de colimador secundario de multiplas folhas / Commisioning and implantation of the dynamic intensity modulated radiation therapy using secondary multi-leaf collimator (MLC)

CECILIO, PAULO J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:01Z (GMT). No. of bitstreams: 0 / A radioterapia de feixe de intensidade modulada (IMRT) no seu modo dinâmico é uma forma de radioterapia tri-dimensional (3D), na qual modula-se um feixe de forma a obter-se a irradiação com campos que possuem perfil variável. Os campos são gerados por um sistema de otimização matemático e transformado em seqüências de movimento ou abertura de lâminas dos colimadores terciários de múltiplas folhas (MLC) ou feixe colimado helicoidal, reproduzindo a fluência de radiação adequada. No processo o operador atribui valores limitantes de dose ao alvo e aos órgãos de risco circunvizinhos para que o sistema de planejamento inverso realize a otimização possível. Após a aprovação do plano de tratamento o mesmo deve ser conferido, através de um controle de qualidade (CQ), onde são verificadas as doses que deverão ser administradas ao paciente, comprovando-se as doses obtidas e aprovadas no plano do sistema de planejamento (SPC). Para este controle os mesmos feixes e campos são medidos em termos de dose absorvida e perfis, através de dosimetria na qual comprova-se que não há erro físico ou dosimétrico no plano que irá tratar o paciente com diferença aceitável de até 5%, também utilizada como tolerância para a aprovação dos 460 casos avaliados nesta tese. Foram apresentados as metodologias para a aceitação no primeiro serviço a utilizá-la no Brasil e os testes de controle de qualidade de dois serviços de radioterapia, desde agosto de 2001 à maio de 2006 e no outro serviço de outubro de 2007 a maio de 2008, com controle de qualidade que permitiram os respectivos tratamentos clínicos com dados de 4 anos, ou seja, 460 casos com 3935 campos de tratamento verificados individualmente por dosimetria. Isto possibilitou o aperfeiçoamento da metodologia e garantia da qualidade nos tratamentos de IMRT dinâmico destes pacientes. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
173

Desenvolvimento e calibracao de um dosimetro pessoal para neutrons utilizando detectores solidos de tracos nucleares

VILELA, EUDICE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 1 02811.pdf: 5186762 bytes, checksum: f178f608c95e9fecbaf736562e08dae5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:94/03409-4
174

Dosimetria interna para o [4-14C] - colesterol em humanos / Internal dosimetry for [4-14C]-cholesterol in humans

MARCATO, LARISSA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:11Z (GMT). No. of bitstreams: 0 / O principal objetivo deste trabalho é fornecer um modelo biocinético validado em termos fisiológicos para a avaliação das doses radiométricas devido à ingestão de [4-14C]-colesterol em humanos. Com o intuito de validar o modelo biocinético proposto para o [4-14C]-Colesterol, os valores de excreção fecal e absorção preditos pelo modelo foram comparados com dados experimentais da literatura, foi obtido um alto grau de concordância entre os resultados de acordo com teste ANOVA (p = 0,416 para os valores de excreção e p = 0,423 para os valores de absorção). Foram calculados os coeficientes de Dose Efetiva (SvBq-1), Dose Equivalente (SvBq-1) e Dose Absorvida (GyBq-1) nos orgãos e tecidos para humanos utilizando a metodologia MIRD e o software de análise compartimental ANACOMP para quatro objetos simuladores que representam: um adulto com massa de 73,3 kg, um adolescente de 15 anos (56,9 kg), uma criança de 10 anos (33,2 kg) e uma criança de cinco anos (19,8 kg). O órgão que obteve a maior Dose Absorvida, para todos os objetos simuladores, foi o intestino grosso inferior (IGI). O conceito da alometria foi utilizado para interpolar o Coeficiente de Dose Absorvida no intestino grosso inferior (DIGI) para massas corpóreas (m) desconhecidas: DIGI(SvBq-1)=161,26.m(kg)-1,025. Para uma mesma quantidade administrada de colesterol, o Coeficiente de Dose Efetiva (E) diminui com o aumento da massa corporal do objeto simulador, em outras palavras, para a mesma atividade administrada os indivíduos com menor massa são submetidos a Doses Efetivas mais elevadas. O conceito de alometria também foi utilizado para interpolar o Coeficiente de Dose Efetiva (E) para massas corpóreas (m) desconhecidas: E(SvBq-1)= 171,1.m(kg)-1,021. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
175

Avaliacao da dose na populacao da regiao urano-fosfatica do Nordeste que utiliza os recursos hidricos da regiao

ANDRADE LIMA, RICARDO de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:10Z (GMT). No. of bitstreams: 1 02943.pdf: 7400226 bytes, checksum: 2a1828504f2dd8a88dc486ab61287612 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
176

Otimizacao no controle dos valores de radiacao nas dependencias do ciclotron de 30 MeV do IPEN

RODRIGUES, DEMERVAL L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:37Z (GMT). No. of bitstreams: 1 07969.pdf: 4735290 bytes, checksum: 35766584f698fd08a530a144cb0a0bd0 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
177

Estudo e avaliacao da radiometria no tratamento fototerapico da hiperbilirrubinemia neonatal / Study and evaluation of radiometry in phototherapeutic treatment of the neonatal hiperbilirubinemia

CALY, JOSE P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:41Z (GMT). No. of bitstreams: 0 / A fototerapia é um procedimento estabelecido há mais de 50 anos no tratamento da icterícia em recém-nascidos. No entanto ainda não há um método padronizado de quantificação da dose fototerápica nos estudos clínicos publicados, dificultando a comparação de estudos prévios sobre a eficácia da fototerapia, bem como o estabelecimento de doses seguras e previsíveis. A dose fototerápica depende, dentre outros fatores, da irradiância média útil entregue pelas unidades fototerápicas. Mas não há procedimentos padronizados tanto na quantificação da irradiância útil ao tratamento, quanto na estimação da irradiância média útil em fontes fototerápicas. Por isso, têm sido relatadas grandes variações nas medições de uma mesma fonte usando os radiômetros disponíveis no mercado, como conseqüência da vasta diversidade de responsividades espectrais dos instrumentos. Um objetivo deste trabalho foi adaptar e aplicar os princípios da radiometria ultravioleta de banda larga na quantificação da irradiância disponível em fontes fototerápicas, estabelecendo procedimentos que permitem comparar irradiâncias medidas em diversas fontes, usando radiômetros com diferentes responsividades espectrais. Outro objetivo foi caracterizar amostras de fontes comumente usadas atualmente, focando o problema da estimação da irradiância média útil em unidades de fototerapia, propondo um método de estimação da irradiância média útil em fontes com foco dirigido. Os resultados experimentais obtidos nos permitem concluir que não somente é necessário padronizar a radiometria fototerápica, como também o método de estimação da irradiância média útil. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
178

Inibicao das reacoes de polimerizacao e de desproporcionamento, exotermicas e explosivas, do monomero tetrafluoroetileno

MOURA, ESPERIDIANA A.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:53Z (GMT). No. of bitstreams: 1 06502.pdf: 9031757 bytes, checksum: 4eb0a51540742e535950d2d55abcd40e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
179

Toronio no ar .Avaliacao da dose ocupacional

CAMPOS, MARCIA P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:49Z (GMT). No. of bitstreams: 1 06772.pdf: 7651270 bytes, checksum: aad35d8f09b378cbb730443e1cd36015 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
180

Medida do perfil de dose no aluminio, irradiado com raios gama de captura de neutrons termicos, utilizando o dosimetro termoluminescente CaSO sub(4):Dy

FEDERICO, CLAUDIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:11Z (GMT). No. of bitstreams: 0 / Radiação gama com energias maiores que 1,25 MeV são usualmente encontradas em ambientes de reatores, aceleradores de partículas e campos de radiação de origem cósmica. Nestas energias, a resposta de um dosímetro varia fortemente com a espessura de material absorvedor, até atingir um valor máximo conhecido como espessura de equibl^rio de partículas carregadas. O objetivo principal do presente trabalho foi a determinação experimental do perfil de dose absorvida por uma amostra de alumínio, para várias energias de feixes de raios gama, de forma a obter uma relação entre a energia média do campo de radiação gama e a espessura de equilíbrio de partículas carregadas para o alumínio. Os dosímetros foram irradiados com radiação gama produzida pela captura de neutrons térmicos em 23 materiais alvos no arranjo experimental montado no canal tangencial do reator do IPEN-CNEN/SP. Na determinação da camada de equilíbrio de partículas carregadas, foi ajustada aos dados experimentais uma função semi-empirica que permitiu obter a espessura de ETPC (Equilíbrio Transitório de Partículas Carregadas) para cada espectro de radiação gama utilizado neste trabalho, com energia média variando no intervalo de 3,26 a 7,85 MeV. Os resultados experimentais do presente trabalho permitiram obter uma relação entre a energia média do campo de radiação gama e a espessura de ETPC, que apresenta uma excelente concordância com o alcance corrigido dos elétrons gerados naquela energia. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0306 seconds