641

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton / Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

Barsanelli, Cristiane 23 November 2006 (has links)
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.
642

Elaboração e validação de um instrumento para identificação da prática de enfermeiros relacionada ao manejo e à prevenção das radiodermatites / Elaboration and validation of na instrument for identification of the practice of nurses to handling and prevention of radiodermatitis

Fuzissaki, Marceila de Andrade 08 May 2012 (has links)
A identificação da prática profissional relacionada à prevenção e ao manejo das radiodermatites é fundamental na medida em que permite elencar dificuldades, como a utilização de protocolos institucionais e o uso de evidências científicas em detrimento de um cuidado baseado em mitos e senso comum, e, consequentemente programar ações educativas para sanar tais problemas que estão associados diretamente à qualidade da assistência. A adoção de instrumentos válidos e confiáveis para mensuração quantitativa é imprescindível na medida em que proporciona credibilidade às informações. Diante da inexistência de instrumentos válidos, optou-se por realizar uma pesquisa destinada à elaboração e à validação de um instrumento neste contexto. Trata-se de um estudo metodológico, com delineamento transversal e análise quantitativa. Utilizou-se a metodologia descrita pelos projetos europeus DISABKIDS® e KIDSCREEN®, adaptada para a realidade do presente estudo, sendo percorridas quatro etapas: revisão da literatura para identificação dos itens importantes e instrumentos existentes; elaboração do instrumento; avaliação pelos juízes e validação semântica. A primeira etapa consistiu na identificação de aspectos relevantes sobre a prevenção e o manejo das toxicidades cutâneas devido à radioterapia, a partir da análise da literatura científica, e a elaboração da primeira versão do instrumento. Em seguida, o instrumento foi submetido à validação de aparência e de conteúdo pelos juízes. Os resultados apontam que, no geral, o instrumento foi considerado claro, objetivo e bem estruturado. Porém, evidenciou-se a necessidade de alguns ajustes que foram analisados pelos pesquisadores e o instrumento foi reestruturado. Na sequência, ocorreu o processo de validação semântica, realizada em um hospital especializado em oncologia. A amostra foi constituída por 27 enfermeiros. Diante da análise dos dados, observou-se que a maioria é do sexo feminino, estudou em instituição particular e terminou o curso de graduação recentemente. Em relação à impressão geral do instrumento, nota-se que ele foi bem aceito pelos profissionais, que o consideraram importante para avaliar a assistência prestada aos pacientes com câncer submetidos à radioterapia. O instrumento foi avaliado como muito bom ou bom. Identificou-se dificuldade de compreensão referente a alguns itens, como aqueles que se iniciam com a palavra \"não\", o termo \"especifique\", entre outros, e quanto ao uso da categoria de resposta \"não se aplica\". Quanto ao formulário de validação semântica específico, observou-se que alguns enfermeiros tiveram dificuldades de compreender palavras como \"fria\", \"lavar\", \"tecido sintético\", portanto houve a necessidade de alteração. Notou-se que foi atribuída pequena importância a itens que indicam orientações e produtos não recomendados por eles na prática, como o uso de talco em pó, amido de milho e limpeza com água oxigenada. Percebe-se, portanto, que o processo de elaboração de instrumentos é complexo e exige análise, discussão e sistematização, sendo fundamental a fase de validação semântica. A pesquisa seguirá para a próxima fase, que é a realização do piloto, cujos objetivos são analisar as propriedades psicométricas do questionário e simular uma pesquisa de campo. Ao final espera-se que o instrumento possa ser utilizado na prática, em diversas localidades e, consequentemente, contribuir para o avanço no conhecimento sobre como o cuidado tem sido dispensado. / The identification of Professional practice related to prevention and handling of radiodermatitis is fundamental insofar it allows to list difficulties, as the use of institutional protocols and the use of scientific evidences to detriment of care based on myths and common sense, and consequently plan educational actions to solve such issues that are directly associated with quality of the assistance care. The adoption of reliable and valid instruments for quantitative measurement is essential insofar it provided credibility to the information. Before the lack of valid instruments, it was chosen to carry out a research aimed at the elaboration and the validation of an instrument in this context. This is a methodological study with transversal delineation and quantitative analysis. The methodology described by European projects DISABKIDS and KIDSCREEN was used which covered four stages: a literature review to identify the important items and existing instruments, elaboration of the instrument, the evaluation and semantic validation. The first stage consisted of identification of relevant aspects on the prevention and handling of skin toxicity due to radiotherapy, from the analysis of scientific literature and from the elaboration of the first version of the instrument. Then the instrument was subjected to validation by the judges. The results indicate that, in general, the instrument was considered clear, objective and well structured. However, it was noticed that there was a need for some adjustments which have been analyzed by the researchers. Then, the process of semantic validation which was performed in a hospital specialized in oncology happened. The sample consisted of 27 nurses. Before data analysis, it was observed that the majority is female, educated at a private institution and has finished the undergraduate program recently. In respect to the overall impression of the instrument, it is observed that it was well accepted by professionals, who have considered it important to evaluate the care provided to cancer patients undergoing radiotherapy. The instrument was evaluated as very good or good. One noted some difficulty of understanding regarding some items, such as those that begin with the word \"no\", the term \"specify\", among others, and also in respect to the use of the response category \"not applicable\". As to specific form of semantic validation, one noticed that some nurses have had some difficulty in understanding words such as \"cold\", \"wash\", \"synthetic fabric\", hence there was the need for alteration. It was noted that minor importance was given to items which indicate directions and to products not recommended by them in practice, such as talcum powder, corn starch and cleaning process using hydrogen peroxide. It can be seen, therefore, that the process of the elaboration of the instruments is complex and demand analysis, discussion and systematization, which turns the semantic validation phase crucial. This research will be lead to the next phase, which is the realization of the pilot. Finally, it is expected that the instrument can be used in practice in different sites, and thus contribute to advances in knowledge concerning how care has been provided.
643

Estudo comparativo dos parâmetros associados à dose absorvida e controle de qualidade em aceleradores lineares com filtro aplainador (FF) e sem filtro aplainador (FFF) / Comparative study of the parameters associated with quality control and absorbed dose in linear accelerators with (FF) and without (FFF) flattening filter

Souza, Anderson Sorgatti de 23 June 2017 (has links)
A utilização da técnica de teleterapia para tratamento de câncer tem sido usada por anos com bons resultados clínicos. Em meados da década de 90, a remoção do filtro aplainador, item que compõe o cabeçote de um acelerador linear de uso clínico, tem sido objeto de estudos por demonstrar bons resultados no tratamento de alguns tipos de câncer. Técnicas utilizadas como Radioterapia de Intensidade Modulada (IMRT) e Radioterapia Estereotáxica (SRT), mostram-se mais eficazes quando não se utiliza o filtro aplainador. A empresa Varian Oncology lançou em 2012 um acelerador linear de uso clínico capaz de operar com o filtro aplainador (FF) e sem o filtro aplainador (FFF), o TrueBeam. Os objetivos desse trabalho são avaliar a homogeneidade de dois importantes parâmetros utilizados para o cálculo de dose nos pacientes submetidos ao tratamento com esse modelo de acelerador linear, a porcentagem de dose profunda (PDP) e índice de qualidade do feixe (TPR20/10). Os dados fornecidos para a análise foram cedidos pelo Hospital Israelita Albert Einstein (HIAE), Real Hospital Português (RHP) e 3 instituições norte-americanas. Através de uma análise estatística dos dados das instituições citadas pode-se observar melhor o comportamento desses parâmetro que demonstraram-se muito homogêneos e com erros menores que 1% na maioria dos casos, confirmando desse modo que os aceleradores lineares do modelo TrueBeam mantém na maioria das vezes uma boa concordância dos parâmetros analisados. / Teletherapy, radiation therapy with linear accelerators, for cancer treatment has being used for years with good clinical results.Since the 90\'s the removal of the flattening filter, item placed at the gantry of the machine, has shown better results for the treatment of some cancers thus being extensively studied. Treatments with Intensity Modulated RadioTherapy (IMRT) and Sthereotaxic RadioTherapy (SRT) were more efficient without the flattening filter. Varian Oncology released the TrueBeam in 2012, a accelerator capable of operating with or without the flattening filter. The aim of this work is to access homogeneity of the percentage depth dose (PDP) and beam quality index (TPR20/10), two important parameters used in patient dose calculations. The data used for analysis were obtained with the Israelita Albert Einstein Hospital (HIAE), Real Português Hospital (RHP) and 3 more institutions located in the United States. The statistical data analysis allowed to observe the parameters behaviors. In general, they were very homogeneous, with errors smaller than 1% confirming the conformance of the TrueBeam accelerators.
644

Comprometimento da mobilidade mandibular em pacientes oncológicos submetidos à radioterapia / Mandibular mobility in patients with head and neck cancer undergoing radiotherapy

Caleffi, Carla de Sousa 04 July 2018 (has links)
A preservação da mobilidade mandibular é um aspecto fundamental para a manutenção da qualidade de vida de pacientes oncológicos submetidos à radioterapia. Este estudo avalia o tempo mínimo de 1 ano decorrido após a realização do tratamento radioterápico, dose e aparelho radioterápico empregados para terapêutica, utilização de sonda nasogástrica e tipo de alimentação, acompanhamento e fisioterapia miofuncional. Integraram este estudo pacientes da Fundação Oncocentro do Estado de São Paulo. Os dados clínicos foram coletados nos respectivos prontuários e as mensurações da amplitude dos movimentos mandibulares de máxima abertura, protrusão e lateralidade direita e esquerda foram registradas em sessão clínica com auxílio de um paquímetro digital. Observou-se que: os gêneros masculino e feminino respondem de modo semelhante na avaliação do comprometimento da mobilidade mandibular; a radioterapia associada à oncocirurgia é a opção terapêutica mais utilizada para o tratamento oncológico de tumores da cavidade oral; o tempo decorrido para a detecção da alteração da mobilidade mandibular é bastante longo, impondo-se medidas preventivas e mesmo interceptadoras mais precoces como o acompanhamento e tratamento com terapia miofuncional; a dose de irradiação e o tipo de aparelho radioterápico empregados no tratamento de pacientes oncológicos são determinantes da alteração da mobilidade mandibular; a utilização de sonda nasogástrica e a dieta pastosa potencializam o efeito da radioterapia no que diz respeito à mobilidade mandibular. / The preservation of mandibular mobility is a fundamental aspect for the maintenance of the quality of life of cancer patients undergoing radiotherapy. This study evaluates the minimum time of 1 year after radiotherapy, dose and radiotherapy used for therapy, use of nasogastric tube and type of feeding, monitoring and myofunctional physiotherapy. Patients at the São Paulo Oncocentro Foundation were enrolled in this study. The clinical data were collected in the respective charts and the measurements of the amplitude of the mandibular movements of maximum opening, protrusion and right and left laterality were recorded in a clinical session with the aid of a digital caliper. It was observed that: the masculine and feminine genera respond similarly in the evaluation of mandibular mobility impairment; radiotherapy associated with oncosurgery is the most used therapeutic option for the oncological treatment of tumors of the oral cavity; the elapsed time to detect the change in mandibular mobility is quite long, imposing preventive and even earlier interceptive measures such as monitoring and treatment with myofunctional therapy; the dose of irradiation and the type of radiotherapy used in the treatment of cancer patients are determinants of the mandibular mobility alteration; the use of nasogastric tube and pasty diet potentiate the effect of radiotherapy with respect to mandibular mobility.
645

Estudo de parâmetros dosimétricos e dosimetria in vivo em radioterapia / Study of dosimetric parameters and in vivo dosimetry in Radiotherapy

Alva Sánchez, Mirko Salomón 31 August 2007 (has links)
Os resultados esperados em Radioterapia requerem o controle da qualidade dos procedimentos executados, existindo a necessidade de avaliar-se a dose administrada aos pacientes e sendo recomendado que a diferença percentual entre as doses prescrita e administrada esteja entre -5% e +7%, conforme a Comissão Internacional sobre Unidades e Medidas em Radiação (ICRU). Especificamente em tratamentos de irradiação de corpo inteiro (TBI, do inglês Total Body Irradiation), que emprega distâncias fonte-superfície extensas e campos largos de radiação, apresentando um grau de complexidade elevada quando comparada com os procedimentos convencionais, não há um protocolo bem estabelecido para o cálculo da dose absorvida. Considerando-se, por outro lado, os efeitos colaterais severos associados ao tratamento, TBI requer um controle rigoroso das doses administradas ao paciente, fazendo com que um programa de verificação do tratamento através de dosimetria in vivo seja imprescindível. O presente trabalho apresenta um estudo dos parâmetros dosimétricos, para campos convencionais e de irradiação de corpo inteiro, como parte de um programa de controle da qualidade em Radioterapia. Os parâmetros dosimétricos foram determinados utilizando-se dosímetros termoluminescentes, câmara de ionização e dosímetro semicondutor. Avaliaram-se as correções necessárias para o uso dos parâmetros dosimétricos, obtidos em condições convencionais, nos tratamentos de irradiação de corpo inteiro, apresentado-se, ainda, uma metodologia de dosimetria in vivo para tratamentos de TBI. Os resultados obtidos permitem concluir que os parâmetros dosimétricos utilizados em TBI devem ser obtidos nas condições próprias desse tipo de técnica, não devendo ser adaptados de condições convencionais, e que a metodologia de dosimetria de entrada é adequada para avaliação das doses nessa técnica de tratamento. / The expected outcomes in Radiotherapy require a strict quality control program to be performed in order to evaluate the doses delivered to patients. Accordingly to the International Commission on Radiation Units and Measurements (ICRU) the possible discrepancies between prescribed and delivered doses to patients must be in a range of -5% and +7%. Treatments of total body irradiation (TBI) use large source-surface distances and broad radiation fields, showing high complexity when compared to conventional procedures and do not present a well-established protocol for the calculation of the absorbed dose. On the other hand, considering, the severe collateral effects associated to this treatment, TBI requires a rigorous control of the doses administrated to the patient and a program of verification of the treatment through in vivo dosimetry is paramount. This work presents a study of dosimetric parameters for both conventional and total body irradiation treatments as part of a quality control program in Radiotherapy. The dosimetric parameters had been determined using termoluminescente dosimetry, ionization chamber, and semiconductor dosimeters. Possible corrections for the use of the conventional conditions-obtained parameters in total body irradiation were evaluated. An in vivo dosimetry methodology had been also studied to be applied to TBI treatments. The obtained results leads to the conclusions that TBI dosimetric parameters must be obtained under proper irradiation conditions and should not be adapted from conventional conditions and that entrance dosimetry is an adequate technique to evaluate delivered doses in TBI.
646

Estudo de dosimetria gel polimérica em radioterapia com feixes de elétrons utilizando ressonância magnética e simulação Monte Carlo / Study of polymer gel dosimetry in Radiotherapy with electron beams using magnetic resonance imaging and Monte Carlo simulation.

Pianoschi, Thatiane Alves 03 February 2014 (has links)
Radioterapia com feixe de elétrons tem sido empregada, frequentemente, para tratamentos de neoplasias superficiais, devido às características de alcance bem definido e alto gradiente de dose em pouca profundidade. Para que as novas técnicas radioterápicas com esse tipo de feixe possam ser implementadas com segurança é necessária a realização de um controle da qualidade rigoroso. Protocolos recomendam que o controle da qualidade para esse tipo de feixe seja realizado com câmara de ionização, porém dosímetros termoluminescentes, diodos e filmes também são empregados com essa finalidade. Entretanto, esses dosímetros não possuem simultaneamente um conjunto de características essenciais para realização do controle da qualidade, como alta resolução espacial, baixa dependência energética, possibilidade de uso em altos gradientes de dose e distribuição tridimensional de dose. Nesse trabalho avaliou-se a utilização do dosímetro polimérico MAGIC-f gel em aplicações em controle da qualidade em Radioterapia com feixes de elétrons. As leituras das amostras de gel foram realizas por ressonância magnética e simulação Monte Carlo foi utilizada para comparação dos resultados. Como parte de um controle da qualidade para feixe de elétrons, foram determinados parâmetros dosimétricos, como perfil de dose e porcentagem de dose em profundidade, e fatores de qualidade do feixe, como R50, em condições de referência e para campos pequenos. Da comparação entre os dados clínicos e MAGIC-f as diferenças máximas encontradas foram de 4%. Além disso, distribuições de dose de aplicações clínicas com feixes de elétrons foram avaliadas pelo método de comparação do índice gama. Considerando os critérios de 3% e 3 mm, os resultados obtidos para o índice gama mostraram concordâncias acima de 94% para os métodos dosimétricos utilizados. Dessa forma, de acordo com as medidas dosimétricas realizadas com o dosímetro MAGIC-f gel conclui- se que a dosimetria polimérica gel pode ser empregada como uma ferramenta auxiliar em procedimentos de controle da qualidade em Radioterapia com feixes de elétrons, assim como uma ferramenta na determinação das distribuições tridimensionais de dose para feixe de elétrons. / Electron beam radiotherapy has been used frequently for treatments of superficial tumors, due its characteristics of well-defined range and high dose gradient at low depth. For new radiotherapy techniques with this type of beam, a strict quality control is necessary for a safe implementation. Protocols recommend that the quality control for electron beams must be performed with an ionization chamber. However, thermoluminescent dosimeters, films and diodes are also used for this purpose. Although, these dosimeters do not have a set of essential characteristics for performing quality control, like high spatial resolution, low energy dependence, possibility of use in high dose gradients and three dimensional dose distribution acquisition. The present work evaluated the use of MAGIC-f gel dosimeter for the quality control in radiotherapy with electron beams. The readings of the gel samples were made by magnetic resonance imaging and Monte Carlo simulation was used to compare the obtained results. As part of a quality control for the electron beam parameters as percentage depth dose and beam profile were determined. Also beam quality factors, such as R50, were calculated in reference conditions and for small fields. The obtained results were compared with clinical data and MAGIC-f the maximum obtained difference was 4%. In addition, dose distributions from clinical applications with electron beams were evaluated by the gamma index. Considering the criteria of 3% DD and 3 mm DTA, the results showed concordance greater than 94% for all dosimetric methods. Thus, according to the dosimetric measurements through MAGIC-f gel dosimeter it can be inferred that the gel dosimeter can be used as auxiliary tool in the quality control procedures in radiotherapy to electron beam. Also, MAGIC-f is a useful a tool to determine tridimensional dose distributions of electron beam.
647

Modelagem de um sistema de planejamento em radioterapia e medicina nuclear com o uso do código MCNP6 / Modeling of a planning system in Radiotherapy and Nuclear Medicine using the MCNP6 code

Massicano, Felipe 03 September 2015 (has links)
O tratamento de câncer possui diversas modalidades. Uma delas é a utilização de fontes de radiação como principal protagonista do tratamento. A radioterapia e a medicina nuclear são exemplos desse tipo de tratamento. Por utilizarem a radiação ionizante como principal ferramenta para a terapia, há a necessidade de se efetuar diversas simulações do tratamento a fim de maximizar a dose nos tecidos tumorais sem ultrapassar os limites de dose nos tecidos sadios circunvizinhos. Os sistemas utilizados na simulação desses tipos de terapia recebem o nome de Sistemas de Planejamento Dosimétrico. A medicina nuclear e a radioterapia possuem seus próprios sistemas de planejamento dosimétricos devido a grande diversidade das informações necessárias às suas simulações. Os sistemas de planejamento em radioterapia são mais consolidados do que os de medicina nuclear e por tal motivo um sistema que aborde tanto os casos de radioterapia como de medicina nuclear contribuiria para significativos avanços na área de medicina nuclear. Dessa forma, o objetivo do trabalho foi modelar um Sistema de Planejamento Dosimétrico com o uso do código de Monte Carlo MCNP6 Monte Carlo N-Particle Transport Code que permitisse incorporar os casos de radioterapia e medicina nuclear e que fosse extensível a novos tipos de tratamentos. A modelagem desse sistema resultou na construção de um Framework, orientado a objetos, nomeado IBMC o qual auxilia no desenvolvimento de sistemas de planejamento que necessitam interpretar grandes quantidades de informações com o objetivo de escrever o arquivo base do MCNP6. O IBMC permitiu desenvolver de maneira rápida e prática sistemas de planejamento para radioterapia e medicina nuclear e os resultados foram validados com sistemas já consolidados. Ele também mostrou alto potencial para desenvolver sistemas de planejamento de novos tipos de tratamentos que utilizam a radiação ionizante. / Cancer therapy has many branches and one of them is the use of radiation sources as treatment leading method. Radiotherapy and nuclear medicine are examples of these treatment types. For using the ionization radiation as main tool for the therapy, there is the need of crafting many treatment simulation in order to maximum the tumoral tissue dose without throught the dose limit in health tissue surrounding. Treatment planning systems (TPS) are systems which have the purpose of simulating these therapy types. Nuclear medicine and radiotherapy have many distinct features linked to the therapy mode and consequently they have different TPS destined for each. The radiotherapy TPS is more developed than the nuclear medicine TPS and by that reason the development of a TPS that was similar to the radiotherapy TPS, but enough generic for include other therapy types, it will contribute with significant advances in nuclear medicine and in others therapy types with radiation. Based on this, the goal of work was to model a TPS that utilizes the Monte Carlo N-Particle Transport code (MCNP6) in order to simulate radiotherapy therapy, nuclear medicine therapy and with potential for simulating other therapy types too. The result of this work was the creation of a Framework in Java language, objectoriented, named IBMC which will assist in the development of new TPS with MCNP6 code. The IBMC allowed to develop rapidly and easily TPS for radiotherapy and nuclear medicine and the results were validated with systems already consolidated. The IBMC showed high potential for developing TPS by new therapy types.
648

Montagem e caracterização de um fantoma para utilização em radioterapia utilizando imagens convencionais por ressonância magnética e contraste por transferência de magnetização / Phanton developing and caractherizing for radiotherapy using conventional magnetic resonance imaging and magnetization transfer contrast

Pastorello, Bruno Fraccini 04 August 2006 (has links)
A dosimetria 3D utilizando gel à base de monômeros é uma importante ferramenta utilizada em casos de Radioterapia, em que há necessidade de uma alta resolução da distribuição espacial de dose. Neste trabalho, desenvolvemos um gel à base de monômeros do acido metacrilico, denominado MAGIC®, com a finalidade de avaliar a distribuição espacial de dose em simulações de tratamento de radioterapia, utilizando duas técnicas de imagens por ressonância magnética, Magnetic Resonance Imaging (MRI): a relaxometria (RT) e a transferência de magnetização (Magnetization Transfer, MT). Para tal, o trabalho foi desenvolvido em três etapas. Na primeira, desenvolvemos fantomas para serem irradiados com radiação ? e x, sobre os quais imagens de ressonância foram obtidas e analisadas. Desenvolvemos também um software, escrito em Matlab®, para analisar as imagens e traçar curvas de isodose dos fantomas irradiados. Em seguida, aperfeiçoamos o preparo, a composição, e as maneiras de adquirir e processar as imagens do gel irradiado. Nessa etapa incorporamos o formaldeido ao gel MAGIC, aumentando sua sensibilidade em 15%. Por fim, simulamos cinco configurações de tratamento de radioterapia e avaliamos as isodoses adquiridas, comparando-as com aquelas obtidas pelo software de planejamento radioterápico virtual, TPS®. As avaliações feitas com a técnica de relaxometria corresponderam às nossas expectativas. Com ela foi possível caracterizar o gel MAGIC, com alguns testes dosimétricos, bem como avaliar as 5 simulações de tratamentos radioterápicos propostas. O gel se mostrou linear até 20 Gy, mas não apresentou níveis aceitáveis de reprodutibilidade, necessitando de uma curva de calibração em cada teste. O gel possui número atômico efetivo próximo ao da água não necessitando de fatores de correções. Na maioria dos casos simulados, as isodoses das simulações feitas com o gel MAGIC reproduziram as simulações virtuais. Infelizmente, não obtivemos, por enquanto, o mesmo sucesso com a avaliação por MT. As imagens de MT não se mostraram confiáveis e por esse motivo as simulações com o gel só foram feitas com a técnica de RT. / The 3D monomeric gel dosimetry is an important tool in radiation therapy cases which needs high spatial dose resolution. In this work we developed a methacrilic acid monomeric gel called MAGIC® to evaluate spatial dose distributions in simulations of radiation therapy treatments. We used two Magnetic Resonance Imaging (MRI) techniques, the relaxometry (RT) and the magnetization transfer (MT). The work was developed in three stages. First of all, the phantoms were created to be irradiated using and x radiations, the MRI were acquired and analyzed. We also developed a software, programmed in Matlab®, to analyze the images and to draw isodoses curves of irradiated phantoms. Following it, we improved the way the gel was prepared and its composition, as well the image acquisition and processing. In this part we added formaldehyde to the gel, improving its sensibility in 15%. Finally, we simulated 5 different radiation therapy treatments and compared the isodoses measured with the isodoses of the radiation therapy treatment planning software (TPS®). The results of the RT technique corresponded to our expectations. Using the RT we characterized the gel with dosimetric tests and evaluated five different radiation therapy treatments. The gel showed a linear relation with the dose until 20 Gy, but the results of the tests were not reproducibles, because of that we made a calibration curve for each test. The effective atomic number of the gel is close to the water, so it was not necessary any correction. In most of the simulated cases, the isodoses measured with the gel reproduced the virtual simulations. Unfortunately, until now, we didn\' t have the same success using the MT technique. The MT images were not reliable and because of that the simulations were only made with the RT technique.
649

Verificação de tratamentos radioterápicos diversos com dosimetria termoluminescente / Assessment of radiotherapic treatments with thermoluminescent dosimetry

Morlotti, Marcelo Scolaro 28 March 2007 (has links)
As técnicas radioterápicas evoluíram muito nas últimas décadas, destacando-se a utilização de feixes segmentados por colimadores de multifolhas, os quais permitem entregar maior quantidade de dose com maior precisão espacial. Os sistemas de planejamento em radioterapia (TPS), entretanto, são em grande parte fechados, com acesso restrito aos parâmetros de cálculo de dose. Desta forma, o presente trabalho teve como principal objetivo comparar valores de dose envolvidas em tratamentos radioterápicos, medidos com a técnica de dosimetria termoluminescente (TL), usando um objeto simulador antropomórfico (Alderson Rando Phantom - ARP) como paciente, com valores de referência extraídos dos TPS em simulações realistas de tratamento. O objeto simulador continha dosímetros TL de LiF (TLD100) posicionados na pelve, no tórax, na cabeça e no pescoço, a fim de que fossem monitoradas regiões com dose homogênea (como no volume alvo planejado - PTV), regiões com gradiente de dose e regiões afastadas do PTV. As irradiações foram feitas usando técnicas de radioterapia conformacional 3D e radioterapia por modulação da intensidade do feixe (IMRT). Quatro TPS foram utilizados: CadPlan, ECLIPSE, Helax-TMS e KonRad. Em algumas situações utilizaram-se algoritmos de cálculo implementados pelos fabricantes nos TPS; dois deles baseados em correção de heterogeneidades (Batho e pencil beam) e um deles baseado em convolução e superposição de feixes simulados (collapsed cone). Nos casos de irradiações com IMRT os algoritmos foram sempre usados. Paralelamente ao uso do ARP, utilizou-se um objeto simulador com água com objetivo de verificar o comportamento dos dosímetros TL expostos a feixes de fótons de alta energia, em comparação com câmaras de ionização cilíndricas do tipo Farmer (volume interno de 0,6 cm3). Além disso, esse objeto simulador possibilitou garantir a qualidade de suportes desenvolvidos para a câmara e para os dosímetros, nos casos de medidas em água. A irradiação da pelve do objeto simulador ARP, região com poucas heterogeneidades, revelou que o comportamento do material que o constitui é equivalente ao da água e, por isso, pode ser usado na simulação de tecido humano em feixes de radioterapia. Simulações de tratamentos revelaram compatibilidade entre valores medidos e planejados no interior do PTV, com discrepâncias menores que 2%; valores que estão dentro dos limites estabelecidos pelo ICRU62 (+7%/-5%, 2?). Nas regiões afastadas do PTV, todos os códigos de planejamento apresentaram discrepâncias relativamente grandes, evidenciando limitações no cálculo de componentes secondárias. Apesar dos algoritmos de cálculo aumentarem a concordância entre doses medidas e planejadas, não foi possível identificar diferenças entre os algoritmos pencil beam e collapsed cone. Em regiões onde havia alto gradiente de dose, as discrepâncias se tornam maiores devido à dificuldade em posicionar os dosímetros no mesmo ponto em que o cálculo é feito. Sistematicamente, observou-se que a técnica para radioterapia 3D apresenta valores de dose dentro dos limites preestabelecidos, enquanto IMRT mostra valores com maior exatidão. / The last decades noticed a massive improvement in radiotherapy techniques and the use of segmented beams produced by multileaf collimators. However, the dose radiation therapy planning systems (TPS) in use are characterized by the restriction of access to the calculation algorithms. The aim of this work was to compare dose values measured in an anthropomorphic phantom (Alderson Rando Phantom - ARP) to the reference dose values obtained from the TPS in real case simulations of radiotherapy treatments. Thermoluminescent dosimetry (TLD) technique was used to evaluate the doses. LiF dosimeters (TLD100) were positioned on the phantom pelvis, thorax, head and neck at homogeneous dose regions, as the Planned Target Volume (PTV), gradient dose regions, and areas far from PTV. The doses were delivered using two techniques, 3D conformal radiotherapy and Intensity Modulated Radiation Therapy (IMRT). Four TPS were used: CadPlan, ECLIPSE, Helax-TMS and KonRad. In several situations, calculation algorithms implemented in these planning systems were employed to take heterogeneities into account: two of them were correction-based algorithms (Batho and Pencil Beam) and one of them based in beam convolution-superposition (Collapsed Cone). Furthermore, a liquid water phantom was used to compare the TLD behavior to the Farmer thimble chamber (0,6 cc internal volume) results when exposed to high-energy photon beams. It was also possible to verify the quality of the PMMA supports that wer used in the calibration of the dosimeters on clinical beam, obtaining reliable results. Both the ARP pelvis and a water phantom showed similar behavior under irradiation, indicating that, in highly homogenous regions, the ARP material can be used to simulate human soft tissues under radiotherapy treatment. Inside the PTV, the dosimetry performed in the ARP, showed compatibility between measured and planned dose values, with discrepancies smaller than 2%, which are within the ICRU62 fixed limits (+7%/-5%, 2?). When the algorithms were used, a better agreement between the experimental and planned doses was achieved, but it was not possible to discriminate the Pencil Beam and Collapsed Cone algorithms. In regions with large dose gradients, the discrepancies between experimental and planned dose values are higher as the difficulties the position of the dosimeters are more critical. The measured doses, when the 3D radiotherapy technique was used, were within the ICRU62 pre-established limits whereas the IMRT technique provider more accurate values.
650

Prurigo pós radioterapia: estudo clínico, histológico e imunohistoquímico / Post radiotherapy prurigo: clinical, histologic and immunohistochemical study

Fabio Francesconi do Valle 27 November 2018 (has links)
Introdução: Prurigo é uma terminologia de conotação sindrômica que tem o prurido como sintoma incondicional. O sinal é dermatológico, caracteristicamente manifestado por pápulas que se distribuem com relativa simetria pelo tegumento. Do ponto de vista clínico é uma condição de fácil suspeita, mas de difícil conclusão causal. Na Fundação Centro de Controle de Oncologia do Amazonas (FCECON), quadro de prurigo em pacientes oncológicos eram ocasionalmente identificados após início da radioterapia para o tratamento do tumor de base, contexto epidemiológico que não é classicamente relacionado ao prurigo. Objetivos: Descrever os aspectos clínicos, histopatológicos e imunoistoquímicos dos casos pósradioterapia. Métodos: estudo transversal, descritivo, de janeiro de 2006 a dezembro de 2012, com seleção de pacientes com CID de prurigo na FCECON. Serão descritas as características clínicas, histopatológicas e imunoistoquimicas dos casos com pesquisa de DNA viral do EBV, CMV e parvovírus B19. Resultados: Foram 35 mulheres e um homem, com idade média de 47 anos, sempre com queixa de prurido. A pelve sempre foi o campo irradiado com mediana de 28 dias para o surgimento dos sintomas. Foram 34 tumores ginecológicos com 31 casos de colo de útero. Ao todo ocorreram 13.339 lesões (média de 371), com 535 do grupo 1 (vesículas e urticas), 4.934 do grupo 2 (pápulas), 4.218 do grupo 3 (escoriações) e 3.652 do grupo 4 (residuais). Os membros inferiores foram acometidos em todos os casos e em 27 casos houve acometimento dos membros superiores. A histologia das 27 lâminas disponíveis identificou epiderme normal em cinco pacientes, atrofia em dois, espongiose em oito e alteração secundária ao prurido nas demais. Espongiose folicular e/ou espongiose do acrossiríngeo foram identificadas por nove ocasiões. Infiltrado perivascular superficial, profundo e intersticial composto por linfócitos e eosinófilos com distribuição perianexial foi o padrão mais encontrado na derme. O padrão do infiltrado foi de linfócitos T CD4 e ausência de linfócitos CD20 e linfócitos CD56. Não foi identificado DNA viral nas amostras examinadas. Discussão: O quadro de prurigo pós-radioterapia possui as mesmas características clínicoepidemiológicas e histológicas da síndrome EPPER. Histologicamente pode ser inclusa dentro das doenças inflamatórias eosinofílicas da pele, com padrão imunoistoquímico do infiltrado sugestivo de reação de hipersensibilidade mediada por linfócitos no padrão Th2. Como reação a picada de mosquitos foi o diagnóstico histológico de todos os casos, postula-se que o prurigo pós radioterapia, ou síndrome EPPER, seja reação imunológica precipitada pela exposição aos antígenos salivares do mosquito em um ambiente imune induzido pelo efeito abscopal secundário a irradiação pélvica. A natureza do estudo não permite confirmar esta conclusão, que deverá ser fruto de pesquisas futuras. Conclusões: O quadro de prurigo pós radioterapia esteve associado a irradiação da pelve, especialmente de tumores ginecológicos, com predomínio do câncer de colo de útero. Clinicamente semelhante a erupção pruriginosa, polimórfica, eosinofílica associada a radioditerapia (EPPER), pode ser classificado como prurigo agudo. As manifestações clínicas, histológicas e imunoistoquímicas são semelhantes ao quadro de hipersensibilidade a picada de mosquito do padrão celular, mediado por linfócitos Th2, sem evidencia de co-participação viral nos casos examinados / Introduction: Prurigo, a terminology used with a syndromic connotation, is characterized by pruritus, as an unconditional symptom, and papules usually distributed with relative symmetry by the integument. From the clinical point of view, it is a condition of easy suspicion, but of difficult causal conclusion. At the Fundação Centro de Controle de Oncologia do Amazonas (FCECON), prurigo was occasionally identified in cancer patients after radiation therapy for the treatment of the underlying tumor, an epidemiological context that is not classically related to prurigo. Objectives: To describe the clinical, histopathological and immunohistochemical aspects of post-radiotherapy prurigo. Methods: a cross-sectional, descriptive study, from January 2006 to December 2012, with the selection of patients with prurigo as classified by international classification of diseases in FCECON. The clinical, histopathological and immunohistochemical characteristics of the cases with viral DNA screening by RT-PCR EBV, CMV and parvovirus B19 is described. Results: There were 35 women and one man, with an average age of 47 years. Pruritus was always present. The pelvis was invariably the irradiated field with a median of 28 days for the onset of symptoms. There were 34 cases with gynecological tumors with 31 of the uterine cervix. A total of 13,339 lesions (mean of 371), with 535 of group 1 (vesicles and urticas), 4,934 of group 2 (papules), 4,218 of group 3 (excoriations) and 3,652 of group 4 (residual). The lower limbs were affected in all cases, and in 27 cases there was involvement of the upper limbs. The histology of the 27 available slides identified normal epidermis in five patients, atrophy in two, spongiosis in eight and alteration secondary to pruritus in the others. Follicular spongiosis or spongiosis of the acrosyringium were identified on nine occasions. A superficial, deep and interstitial perivascular infiltrate composed of lymphocytes and eosinophils with perianexial distribution was the most common pattern found in the dermis. The composition of the infiltrate was of CD3 CD4 T lymphocytes and absence of CD20 lymphocytes and CD56 lymphocytes. There were no viral DNA identified in the samples examined. Discussion: Postradiotherapy prurigo has the same clinical-epidemiological and histological characteristics of eosinophilic, polymorphic, pruritic associated with radiotherapy (EPPER) syndrome. Histologically it can be included within the inflammatory eosinophilic diseases of the skin, and the immunohistochemestry pattern of the infiltrate suggests a hypersensitivity reaction mediated by Th2 lymphocytes. Since a reaction to mosquito bites was the clinicopathological diagnosis of all cases, the authors postulate that post-radiation prurigo, or EPPER syndrome, is an immunological reaction precipitated by exposure to the mosquito\'s salivary antigens in an immune environment induced by the abscopal effect secondary to irradiation of the pelvis. The nature of the study does not allow this conclusion, which should be the result of future research. Conclusions: Post-radiation prurigo was associated with irradiation of the pelvis especially to treat gynecological tumors, with cancer of the cervix predominance. Clinically similar to EPPER syndrome, it can be classified as acute prurigo. Clinical, histological and immunohistochemical manifestations are similar to the hypersensitivity of Th2 lymphocytemediated mosquito bites, with no evidence of viral co-participation in the cases examined