1

[en] ELECTRONS LONGITUDINAL FOCUSING IN A LINEAR ACCELERATOR / [pt] FOCALIZAÇÃO LONGITUDIONAL DE ELETRONS EM ACELERADOR LINEAR

FRANCIRA RODRIGUES DA CUNHA 22 September 2009 (has links)
[pt] Este trabalho está integrado no programa geral de atividades, destinado ao projeto e a execução, no Centro Brasileiro de Pesquisas Físicas, de um Acelerador Linear de Elétrons com energia final de 50 MeV. O espectro de energia de uma máquina dessa natureza e a eficiência de captura dos elétrons pela onda estão condicionados à prévia determinação e otimização das condições de focalização axial, segundo as quais virão a ser dimensionados os parâmetros da primeira seção aceleradora, destinada a captar os elétrons injetados e transportá-los à região ultra-relativista, grupando-os simultaneamente em fase e em energia. Constitui primeiro objeto desta tese a solução do problema dessa focalização, dentro de certas ordens de grandeza, previamente fixadas para alguns parâmetros, por imposições, outras, do Projeto. A execução compreende a análise do problema, a sua adaptação ao cálculo em computador e a variação de parâmetros em cálculo numérico, efetuada de forma paralela com o levantamento de famílias de cursos e a interpretação das curvas levantadas, de modo a discernir os sentidos mais convenientes a adotar na variação acima referida, para que a otimização venha a ser obtida. O texto é conduzido até o cotejo entre as previsões teóricas e as reais condições de desempenho da seção grupadora do acelerador, dimensionada e construída segundo as prescrições fixadas ao longo desta tese. Como segundo objeto, o presente trabalho, dentro do mesmo mecanismo de procedimento, estuda o dimensionamento de um pré-grupador, atuando por modulação de velocidade, destinado a acrescentar eficiência, no mecanismo de captura dos elétrons, à seção grupadora tratada precedentemente. / [en] This work is integrated in the general schedule of activities aiming the design and setting up a Linear Electron Accelerator at the Brazilian center of Physical Research. The Linear Accelerator will provide a final energy of 50 MeV. The energy spectrum of such a device, and the electron capture efficiency of the wave are conditioned to the previous determination and optimization of the axial focusing conditions. These conditions will determine the parameters of the first accelerating unit, wich is designed to collect the injected electrons and take them to the ultra-relativistc region bunching them simultaneously by phase and by energy levels. It is the main purpose of this thesis to solve the problem of focusing, within certain conditions imposed on some parameters by other aspacts of the project. The work comprises the analysis of the problem, its adaptation to electronic computing and the numerical variation of the parameters, together with the plotting and interpretation of the curves, to choose the most convenient directions of change to adapt on the parameters, to attain optimization. The text goes as far as comparing the theoretical predictions with the measured performance of the bunching unit, designed and built as prescribed in this thesis. As a second object, with the same procedure, we studied the design of a pre-buncher, acting on velocity-modulation, to improve the electron capture efficiency of the bunching unit mentioned above.
2

[en] ELETRONIC R.F. ENERGY GENERATION SYSTEM TO FEED A LINEAR ELECTRON ACCELERATOR / [pt] SISTEMA DE ALIMENTAÇÃO EM ENERGIA EM R.F. PARA ACELERADOR LINEAR DE ELÉTRONS

NEWTON MAGALHAES SANCHES 21 September 2009 (has links)
[pt] O presente trabalho descreve o projeto, a construção e o ajuste sob reais condições operativas, do sistema eletrônico gerador de energia R.F. destinado a alimentar a seção grupadora (buncher) de 7 MeV, do Acelerador Linear de Elétrons de 50 MeV, em construção no C.B.P.F.. Envolve não sòmente a realização dos moduladores de pulsos, cujo desenvolvimento é detalhado no texto que se segue, mas também a do equipamento eletrônico de regulação e controle que, por envolver técnica corrente, é abordado de forma suscinta e deslocado para o título Apêndice. / [en] This work covers the desing, construction and adjustment under real operating conditions, of the Electronic R.F. Energy Generation System that feeds the 7 MeV bunching unit of the 50 MeV Linear Electron Accelerator under construction at the C.B.P.F.. The development of the pulse modulators is described in detail, as well as the eletroctronic control equipment. Because the latter subject involves current techiniques, it is briefly described under the title Apendix.
3

Estudo comparativo dos parâmetros associados à dose absorvida e controle de qualidade em aceleradores lineares com filtro aplainador (FF) e sem filtro aplainador (FFF) / Comparative study of the parameters associated with quality control and absorbed dose in linear accelerators with (FF) and without (FFF) flattening filter

Souza, Anderson Sorgatti de 23 June 2017 (has links)
A utilização da técnica de teleterapia para tratamento de câncer tem sido usada por anos com bons resultados clínicos. Em meados da década de 90, a remoção do filtro aplainador, item que compõe o cabeçote de um acelerador linear de uso clínico, tem sido objeto de estudos por demonstrar bons resultados no tratamento de alguns tipos de câncer. Técnicas utilizadas como Radioterapia de Intensidade Modulada (IMRT) e Radioterapia Estereotáxica (SRT), mostram-se mais eficazes quando não se utiliza o filtro aplainador. A empresa Varian Oncology lançou em 2012 um acelerador linear de uso clínico capaz de operar com o filtro aplainador (FF) e sem o filtro aplainador (FFF), o TrueBeam. Os objetivos desse trabalho são avaliar a homogeneidade de dois importantes parâmetros utilizados para o cálculo de dose nos pacientes submetidos ao tratamento com esse modelo de acelerador linear, a porcentagem de dose profunda (PDP) e índice de qualidade do feixe (TPR20/10). Os dados fornecidos para a análise foram cedidos pelo Hospital Israelita Albert Einstein (HIAE), Real Hospital Português (RHP) e 3 instituições norte-americanas. Através de uma análise estatística dos dados das instituições citadas pode-se observar melhor o comportamento desses parâmetro que demonstraram-se muito homogêneos e com erros menores que 1% na maioria dos casos, confirmando desse modo que os aceleradores lineares do modelo TrueBeam mantém na maioria das vezes uma boa concordância dos parâmetros analisados. / Teletherapy, radiation therapy with linear accelerators, for cancer treatment has being used for years with good clinical results.Since the 90\'s the removal of the flattening filter, item placed at the gantry of the machine, has shown better results for the treatment of some cancers thus being extensively studied. Treatments with Intensity Modulated RadioTherapy (IMRT) and Sthereotaxic RadioTherapy (SRT) were more efficient without the flattening filter. Varian Oncology released the TrueBeam in 2012, a accelerator capable of operating with or without the flattening filter. The aim of this work is to access homogeneity of the percentage depth dose (PDP) and beam quality index (TPR20/10), two important parameters used in patient dose calculations. The data used for analysis were obtained with the Israelita Albert Einstein Hospital (HIAE), Real Português Hospital (RHP) and 3 more institutions located in the United States. The statistical data analysis allowed to observe the parameters behaviors. In general, they were very homogeneous, with errors smaller than 1% confirming the conformance of the TrueBeam accelerators.
4

Estudo comparativo dos parâmetros associados à dose absorvida e controle de qualidade em aceleradores lineares com filtro aplainador (FF) e sem filtro aplainador (FFF) / Comparative study of the parameters associated with quality control and absorbed dose in linear accelerators with (FF) and without (FFF) flattening filter

Anderson Sorgatti de Souza 23 June 2017 (has links)
A utilização da técnica de teleterapia para tratamento de câncer tem sido usada por anos com bons resultados clínicos. Em meados da década de 90, a remoção do filtro aplainador, item que compõe o cabeçote de um acelerador linear de uso clínico, tem sido objeto de estudos por demonstrar bons resultados no tratamento de alguns tipos de câncer. Técnicas utilizadas como Radioterapia de Intensidade Modulada (IMRT) e Radioterapia Estereotáxica (SRT), mostram-se mais eficazes quando não se utiliza o filtro aplainador. A empresa Varian Oncology lançou em 2012 um acelerador linear de uso clínico capaz de operar com o filtro aplainador (FF) e sem o filtro aplainador (FFF), o TrueBeam. Os objetivos desse trabalho são avaliar a homogeneidade de dois importantes parâmetros utilizados para o cálculo de dose nos pacientes submetidos ao tratamento com esse modelo de acelerador linear, a porcentagem de dose profunda (PDP) e índice de qualidade do feixe (TPR20/10). Os dados fornecidos para a análise foram cedidos pelo Hospital Israelita Albert Einstein (HIAE), Real Hospital Português (RHP) e 3 instituições norte-americanas. Através de uma análise estatística dos dados das instituições citadas pode-se observar melhor o comportamento desses parâmetro que demonstraram-se muito homogêneos e com erros menores que 1% na maioria dos casos, confirmando desse modo que os aceleradores lineares do modelo TrueBeam mantém na maioria das vezes uma boa concordância dos parâmetros analisados. / Teletherapy, radiation therapy with linear accelerators, for cancer treatment has being used for years with good clinical results.Since the 90\'s the removal of the flattening filter, item placed at the gantry of the machine, has shown better results for the treatment of some cancers thus being extensively studied. Treatments with Intensity Modulated RadioTherapy (IMRT) and Sthereotaxic RadioTherapy (SRT) were more efficient without the flattening filter. Varian Oncology released the TrueBeam in 2012, a accelerator capable of operating with or without the flattening filter. The aim of this work is to access homogeneity of the percentage depth dose (PDP) and beam quality index (TPR20/10), two important parameters used in patient dose calculations. The data used for analysis were obtained with the Israelita Albert Einstein Hospital (HIAE), Real Português Hospital (RHP) and 3 more institutions located in the United States. The statistical data analysis allowed to observe the parameters behaviors. In general, they were very homogeneous, with errors smaller than 1% confirming the conformance of the TrueBeam accelerators.
5

Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG / Physical Dosimetric Parameters Commissioning in Clinical Linear Accelerators using FXG dosimeter

Petchevist, Paulo Cesar Dias 22 May 2015 (has links)
A International Comission on Radiation Units and Measurements (ICRU) recomenda que a incerteza total de um tratamento radioterápico não deva ultrapassar de 5%, ou seja, cada etapa do processo de entrega da dose absorvida ao volume alvo do paciente tenha incerteza menor que esse valor (ICRU 50, 1993; ICRU 62, 1999). O cuidado com essas incertezas inicia-se na instalação da máquina (neste caso, de um Acelerador Linear Clínico), passando pela sua aceitação, pelo comissionamento, perdurando nos controles de qualidade posteriores e até em novos comissionamentos, se necessários. Os parâmetros físicos dosimétricos mínimos necessários a serem comissionados para feixes de fótons e elétrons são: Porcentagem de Dose em Profundidade (PDD), Perfis de Campos abertos e filtrados, Fatores de Espalhamento Total (Scp), Cone (Fcone) e de Transmissão (de Filtros em cunha FF, Bandeja FB, e de Transmissão intra FMLC,intra e de fuga inter lâminas FMLC,inter), além da Determinação da Posição Virtual da Fonte de Elétrons através da SSD efetiva (SSDeff). Para tal, a American Association of Physicists in Medicine (AAPM), através do seu protocolo mais recente, apresenta objetos simuladores, tipos e tamanhos de detectores, arranjos e procedimentos experimentais específicos, através dos quais é possível inferir os parâmetros dosimétricos de feixes de fótons e elétrons, usando varredura destes com câmara de ionização (CI), considerando o erro total das medidas menor do que 1% (AAPM TG 106, 2008). Entretanto este mesmo protocolo cita de maneira sucinta ou pouco detalhada, a possibilidade da utilização de dosímetros tipo gel para o citado comissionamento, já que possuem diversas vantagens a serem consideradas na Radioterapia, como equivalência ao tecido mole (Z e ), independência energética num amplo intervalo de energia de fótons e elétrons, além da alta resolução espacial. Desta forma, o objetivo geral deste trabalho é apresentar de forma inédita, o comissionamento dos parâmetros físicos dosimétricos de aceleradores lineares clínicos (PFDALC), especificamente através do dosímetro Fricke Xilenol Gel (FXG), como método alternativo e/ou complementar aos internacionais vigentes. Para tal, neste trabalho foram desenvolvidos dispositivos e procedimentos que proporcionassem aos usuários uma forma prática, eficiente e de baixo custo para obtenção dos parâmetros citados através do FXG, em relação aqueles obtidos com a CI (método padrão). Todos os resultados dos parâmetros físicos dosimétricos obtidos com o dosímetro citado foram validados com a CI, considerando a incerteza preconizada para a mesma. Esses resultados sugerem que o FXG efetivamente poderá ser utilizado para o comissionamento de aceleradores lineares clínicos e que um protocolo específico para este dosímetro poderá ser gerado. / The International Commission on Radiation Units and Measurements (ICRU) recommends that the total radiotherapy treatment uncertainty should not exceeds 5%, in other words, considering that each step involved in the absorbed dose delivery process should not surpass the cited value (ICRU 50, 1993; ICRU 62, 1999). The uncertainties considered are those involved with, the machine installation (in this work, a Clinical Linear Accelerator), its acceptance, commissioning, followed by those related to subsequent quality controls and even new commissioning, if necessary. The minimum required physical dosimetric parameters to be commissioned for electron or photon beams are: the Percentage Depth Dose (PDD), the filtered and open Field Profiles, Total Scatter Factors (Scp), Cone Factor (Fcone), Transmission Factors: Wedge Filter (FF), Tray (FB), intra Leaf (FMLC,intra) and inter Leaf Leakage (FMLC,inter), besides the Virtual Source Position Determination (SSDeff). For this purpose, the American Association of Physicists in Medicine (AAPM), through its last protocol, provides guidelines on phantom and detector selections, setting up of phantom for data acquisition (for scanning and no-scanning data), procedures for acquiring the cited beam parameters with ionizing chambers (CI) and methods to reduce the total measurement error lower than 1% (AAPM TG 106, 2008). However, this protocol does not present any information or details about the physical dosimetric parameters for clinical linear accelerators (PFDALC), through gel dosimeters once they present several useful advantages for Radiotherapy, such as: soft tissue equivalence (Z and ), wide energy independence range for photons or electrons beams and high spatial resolution. The scope of this work is to present an innovative way for physical dosimetric parameters commissioning, specifically using the Fricke Xylenol Gel (FXG) dosimeter, like an alternative and/or complementary method to that employed internationally. Devices and procedures have been developed for this work in order to infer the cited parameters, in a practical, efficient and low cost way, compared to that used with CI (standard method). All the FXG results obtained were validated with the CI, considering the uncertainty recommended for the last one. The results suggest that the FXG effectively can be used for physical dosimetric parameters commissioning for clinical linear accelerators and a new specific protocol can be generated.
6

Comissionamento dos parâmetros físicos dosimétricos em aceleradores lineares clínicos usando o dosímetro FXG / Physical Dosimetric Parameters Commissioning in Clinical Linear Accelerators using FXG dosimeter

Paulo Cesar Dias Petchevist 22 May 2015 (has links)
A International Comission on Radiation Units and Measurements (ICRU) recomenda que a incerteza total de um tratamento radioterápico não deva ultrapassar de 5%, ou seja, cada etapa do processo de entrega da dose absorvida ao volume alvo do paciente tenha incerteza menor que esse valor (ICRU 50, 1993; ICRU 62, 1999). O cuidado com essas incertezas inicia-se na instalação da máquina (neste caso, de um Acelerador Linear Clínico), passando pela sua aceitação, pelo comissionamento, perdurando nos controles de qualidade posteriores e até em novos comissionamentos, se necessários. Os parâmetros físicos dosimétricos mínimos necessários a serem comissionados para feixes de fótons e elétrons são: Porcentagem de Dose em Profundidade (PDD), Perfis de Campos abertos e filtrados, Fatores de Espalhamento Total (Scp), Cone (Fcone) e de Transmissão (de Filtros em cunha FF, Bandeja FB, e de Transmissão intra FMLC,intra e de fuga inter lâminas FMLC,inter), além da Determinação da Posição Virtual da Fonte de Elétrons através da SSD efetiva (SSDeff). Para tal, a American Association of Physicists in Medicine (AAPM), através do seu protocolo mais recente, apresenta objetos simuladores, tipos e tamanhos de detectores, arranjos e procedimentos experimentais específicos, através dos quais é possível inferir os parâmetros dosimétricos de feixes de fótons e elétrons, usando varredura destes com câmara de ionização (CI), considerando o erro total das medidas menor do que 1% (AAPM TG 106, 2008). Entretanto este mesmo protocolo cita de maneira sucinta ou pouco detalhada, a possibilidade da utilização de dosímetros tipo gel para o citado comissionamento, já que possuem diversas vantagens a serem consideradas na Radioterapia, como equivalência ao tecido mole (Z e ), independência energética num amplo intervalo de energia de fótons e elétrons, além da alta resolução espacial. Desta forma, o objetivo geral deste trabalho é apresentar de forma inédita, o comissionamento dos parâmetros físicos dosimétricos de aceleradores lineares clínicos (PFDALC), especificamente através do dosímetro Fricke Xilenol Gel (FXG), como método alternativo e/ou complementar aos internacionais vigentes. Para tal, neste trabalho foram desenvolvidos dispositivos e procedimentos que proporcionassem aos usuários uma forma prática, eficiente e de baixo custo para obtenção dos parâmetros citados através do FXG, em relação aqueles obtidos com a CI (método padrão). Todos os resultados dos parâmetros físicos dosimétricos obtidos com o dosímetro citado foram validados com a CI, considerando a incerteza preconizada para a mesma. Esses resultados sugerem que o FXG efetivamente poderá ser utilizado para o comissionamento de aceleradores lineares clínicos e que um protocolo específico para este dosímetro poderá ser gerado. / The International Commission on Radiation Units and Measurements (ICRU) recommends that the total radiotherapy treatment uncertainty should not exceeds 5%, in other words, considering that each step involved in the absorbed dose delivery process should not surpass the cited value (ICRU 50, 1993; ICRU 62, 1999). The uncertainties considered are those involved with, the machine installation (in this work, a Clinical Linear Accelerator), its acceptance, commissioning, followed by those related to subsequent quality controls and even new commissioning, if necessary. The minimum required physical dosimetric parameters to be commissioned for electron or photon beams are: the Percentage Depth Dose (PDD), the filtered and open Field Profiles, Total Scatter Factors (Scp), Cone Factor (Fcone), Transmission Factors: Wedge Filter (FF), Tray (FB), intra Leaf (FMLC,intra) and inter Leaf Leakage (FMLC,inter), besides the Virtual Source Position Determination (SSDeff). For this purpose, the American Association of Physicists in Medicine (AAPM), through its last protocol, provides guidelines on phantom and detector selections, setting up of phantom for data acquisition (for scanning and no-scanning data), procedures for acquiring the cited beam parameters with ionizing chambers (CI) and methods to reduce the total measurement error lower than 1% (AAPM TG 106, 2008). However, this protocol does not present any information or details about the physical dosimetric parameters for clinical linear accelerators (PFDALC), through gel dosimeters once they present several useful advantages for Radiotherapy, such as: soft tissue equivalence (Z and ), wide energy independence range for photons or electrons beams and high spatial resolution. The scope of this work is to present an innovative way for physical dosimetric parameters commissioning, specifically using the Fricke Xylenol Gel (FXG) dosimeter, like an alternative and/or complementary method to that employed internationally. Devices and procedures have been developed for this work in order to infer the cited parameters, in a practical, efficient and low cost way, compared to that used with CI (standard method). All the FXG results obtained were validated with the CI, considering the uncertainty recommended for the last one. The results suggest that the FXG effectively can be used for physical dosimetric parameters commissioning for clinical linear accelerators and a new specific protocol can be generated.
7

[en] METROLOGICAL EVALUATION OF THE RADIATION FIELD SIZE BY LINEAR ACCELERATORS / [pt] AVALIAÇÃO METROLÓGICA DO TAMANHO DE CAMPO IRRADIADO POR ACELERADORES LINEARES

NILMARA ALMEIDA GUIMARÃES 30 August 2018 (has links)
[pt] O objetivo desta dissertação é o estudo de procedimentos para avaliação da confiabilidade metrológica do tamanho de campo irradiado (TCI) por aceleradores lineares. No contexto das recentes alterações no panorama regulamentar dos serviços de radioterapia, com a implementação da RDC número 20, em 2006, pela Agência Nacional de Vigilância Sanitária (ANVISA), foi estabelecida a compulsoriedade do uso do densitômetro óptico na verificação do TCI, como parte do controle da qualidade. Questões associadas à implementação prática dos recentes requisitos para medição do tamanho de campo irradiado e as recentes indicações do potencial uso de filmes radiocrômicos para o controle da qualidade em radioterapia motivaram a realização do presente trabalho. Foram empregados três diferentes procedimentos para avaliação do tamanho de campo irradiado por aceleradores lineares utilizados em treze serviços de radioterapia localizados no Estado do Rio de Janeiro, utilizando filmes radiocrômicos EBT QD mais, RTQA, densitômetro óptico DensiX tipo T52001 ou scanner de transmissão Microtek. Os resultados destacam a contribuição das fontes de incerteza de medição para cada procedimento realizado e indicam a necessidade de considerá-la na avaliação da conformidade utilizando o densitômetro óptico (DO). Devido às propriedades do filme radiocrômico RTQA, o mesmo não pode ser utilizado no procedimento de medição com DO. Em conclusão, o uso do procedimento de medição utilizando scanner mostrou-se mais adequado para avaliação das dimensões de campos de radiação não-homogêneos. / [en] The objective of the present work is to study different procedures for metrological evaluation of the size of the radiation field emitted by linear accelerators. In the context of the recent requirements determined by the publication of the RDC number 20, in 2006, by National Agency for Sanitary Vigilance (Anvisa), the compulsory use of the optical densitometer for the measurements of the field size during quality control tests was introduced. Practical implementation issues associated with these requirements and the recent studies indicating the potential use of radiochromic films for measurements of the field size motivated the present work. Three different procedures were employed in order to evaluate the radiation field size emitted by linear accelerators used in thirteen radiotherapy services located in Rio de Janeiro, using radiochromic films EBT QD plus and RTQA, optical densitometer DensiX type T52001 or scanner Microtek. The results indicate the contribution of the measurement uncertainty associated to each procedure performed, highlighting the importance of its consideration during tests for conformity assessment with the recently required optical densitometer. Nevertheless, the RTQA radiochromic film properties precluded its use in the procedure using optical densitometer. In conclusion, among the evaluated procedures for radiation field evaluation, the use of the scanner was the most appropriate, especially if dimensional non-homogeneities are present.
8

Avaliação de materiais usando a radiografia computadorizada (CR) empregando um acelerador linear e cobalto - 60 como fontes de altas energias / Evaluation of materials using computed radiography (CR) employing a linear accelerator and cobalt - 60 as source of high energy

Heleno Ribeiro Simões 15 December 2012 (has links)
Nas construções de caldeiras de força, vasos de pressão e outros tipos de equipamentos para os diversos segmentos industriais têm exigido da engenharia de materiais um desenvolvimento tecnológico para melhores processos na obtenção de materiais fundidos, forjados, laminados, e outros. Desenvolver recursos tecnológicos que minimizem a presença de imperfeições que possam comprometer a integridade estrutural dos equipamentos que operam com pressão tem sido uma busca constante tanto nas usinas como nas indústrias de bens de capital nas fases das construções. Uma construção implica em seleção de materiais, projeto, fabricação, exames, inspeção, testes, certificação e dispositivos de alívio que atendam aos requisitos dos códigos e normas. Estes requisitos estão cada vez maiores e estabelecem limites para a existência destas imperfeições vão de encontro à necessidade de lançar mão de métodos de ensaios não destrutivos que permitam sempre a melhor probabilidade de detecção. Os processos de controle da qualidade têm buscado por meio das novas tecnologias aumentarem a sua sensibilidade, visando à detecção de descontinuidades que hoje são detectadas pelos métodos convencionais. Em termos de ensaios não destrutivos, as exigências para o ensaio radiográfico convencional estão no limite da sensibilidade dos filmes radiográficos industriais disponíveis, além do compromisso de buscar um tempo de exposição menor ser sempre um fator importante a ser considerado na qualidade, segurança e produtividade tanto na fábrica como no campo. O objetivo deste trabalho foi estudar e avaliar a técnica de radiografia computadorizada (RC) em relação à radiografia convencional para inspeção dos materiais, utilizando os parâmetros de avaliação, tais como, relação sinal ruído, resolução espacial, ferramentas para detectabilidade, sensibilidade ao contraste e tons de cinza, que são aplicáveis nas avaliações de imagens digitais. Para a avaliação da técnica de radiografia industrial digital foi utilizado um corpo-de-prova fabricada pelo processo de fundição com espessura de 75 a 150 mm, com defeitos típicos do processo. O corpo-de-prova foi radiografado com a técnica convencional e digital. Na técnica convencional foram utilizados os filmes radiográficos industriais tipos I e II do ASTM E 1815, um acelerador linear Varian modelo Linatron 400 de 4 MeV e duas fontes de Cobalto-60 com atividades diferentes. Na técnica computadorizada foram utilizados as mesmas fontes de radiação, uma placa de fósforo denominada IPX e um equipamento CR-50P ambos da GE IT. Pelos resultados obtidos pode-se verificar que a radiografia digital com os equipamentos avaliados, atende satisfatoriamente os códigos e normas que são utilizadas na avaliação de peças fundidas. A técnica mostrou-se mais qualitativa quando na avaliação das descontinuidades localizadas nas seções críticas, pois o sistema RC possibilita a utilização de ferramenta de perfil de linha que fornece os valores de nível de cinza ao longo de uma trajetória linear demarcada na área da imagem da descontinuidade. Com isto, mesmo em poucos experimentos e um único sistema de RC pode-se concluir que a técnica é bastante vantajosa na detecção de descontinuidades nos processos de fabricação e que atendeu tanto os requisitos do ASTM E 272 para o cobre ou o ASME Seção VIII Divisão 1, Apêndice 7 que referenciam os padrões radiográficos conforme as normas ASTM E-186 e ASTM E-280 para aços fundidos. / In the constructions of power boilers, pressure vessels and other equipment for several industries has required the development of materials engineering technology for better processes in obtaining materials cast, forged, rolled, and others. Develop technological resources that minimize the presence of imperfections that could compromise the structural integrity of the equipment operating pressure has been a constant search both in plants and in capital goods industries phases of construction. A construction involves materials selection, design, fabrication, testing, inspection, testing, certification, and relief devices that meet the requirements of codes and standards. These requirements are increasing and establish limits for the existence of these imperfections go against the need to resort to non-destructive testing methods that enable always the best probability of detection. The processes of quality control have sought through new technologies increase their sensitivity in order to detect discontinuities of today are detected by conventional methods. In terms of non-destructive testing, requirements for conventional radiographic testing are at the limit of sensitivity of available industrial radiographic films, besides the commitment to seek a lower exposure time is always an important factor to be considered in quality, safety and productivity both in the factory and in the field. The aim of this work was to study and evaluate the technical radiography Computed (RC) compared to conventional radiography for inspection of materials, using evaluation parameters such as signal to noise ratio, spatial resolution, and tools for detectability, contrast sensitivity and grayscale, which apply in evaluations of digital images. For the evaluation of industrial radiography technique it was used a test specimen manufactured by the casting process with thickness from 75 to 150 mm, with typical defects in the process. The test specimen was X-rayed with the conventional and digital techniques. In the conventional technique were used industrial radiographic films types I and II to ASTM E 1815, a linear accelerator Varian model 400 Linatron 4 MeV and two cobalt-60 sources with different activities. In the technique computed were used the same radiation source, a phosphor plate IPX and an apparatus called CR-50P both GE IT. From the results it can be seen that with digital radiography equipment evaluated satisfactorily meets the codes and standards that are used in the evaluation of castings. The technique was more qualitative evaluation when the discontinuities located in critical sections for the system to use RC allows tool profile line shows values of gray level along a linear path demarcated in the image area discontinuity. With this, even in a few experiments a single system and RC can be concluded that the technique is quite advantageous in the detection of discontinuities in the manufacturing processes and that both met the requirements of ASTM E 272 for copper or ASME Section VIII Division 1, Appendix 7 that reference radiographic patterns according to ASTM E-186 and ASTM E-280 for steel castings.