• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Heat Transfer Simulation of Reactor Cavity Cooling System Experimental Facility using RELAP5-3D and Generation of View Factors using MCNP

Wu, Huali 16 December 2013 (has links)
As one of the most attractive reactor types, The High Temperature Gas-cooled Reactor (HTGR) is designed to be passively safe with the incorporation of Reactor Cavity Cooling System (RCCS). In this paper, a RELAP5-3D simulation model is set up based on the 1/16 scale experimental facility established by Texas A&M University. Also, RELAP5-3D input decks are modified to replicate the experiment procedures and the experimental results are compared with the simulation results. The results show there is a perfect match between experimental and simulation results. Radiation heat transfer dominates in the heat transfer process of high temperature gas-cooled reactor due to its high operation temperature. According to experimental research done with the RCCS facility in Texas A&M University, radiation heat transfer takes up 80% of the total heat transferred to standing pipes. In radiation heat transfer, the important parameters are view factors between surfaces. However, because of the geometrical complexity in the experimental facility, it is hard to use the numerical method or analytical view factor formula to calculate view factors. In this project, MCNP based on the Monte Carlo method is used to generate view factors for RELAP5-3D input. MCNP is powerful in setting up complicated geometry, source definition and tally application. In the end, RCCS geometry is set up using MCNP and view factors are calculated.
2

Simulation of natural circulation in an air-cooled Reactor Cavity Cooling System using Flownex / Kabelo Albert Sehoana

Sehoana, Kabelo Albert January 2014 (has links)
Nuclear reactors with improved safety concepts are currently being studied within the nuclear engineering community, with a focus on passive safety features. One of these reactor concepts is the Very High Temperature gas-cooled Reactor (VHTR) of which the Reactor Cavity Cooling Systems (RCCS) is seen as an integral and crucial part of the passive safety concept. Considerable validation and development of the necessary software tools is required to perform analysis and designs of these future reactor concepts. The primary objective of this study is to establish a methodology for the creation of an integrated system level process model of a typical air-cooled RCCS in Flownex®, and to illustrate its applicability by simulating different scenarios that illustrate the operational characteristics of such a system. For this purpose, the existing RCCS conceptual design that is being studied by the KAERI was used as the case study. As a start, selected case studies were performed to verify that the Flownex® models were set up correctly to perform natural circulation flows, both in steady and transient conditions, and with radiation, convection and conduction taking part. These are the major typical physical phenomena in the RCCS. The models were compared with EES (Engineering Equation Solver) models of the same geometries and specifications. There was a good agreement between Flownex® and EES model results. After this verification, a simulation model of the integrated RCCS system was developed. The Flownex® models were applied to model selected possible operational scenarios. The major observations from the results are that: - The RCCS carries with it enough heat to the ambient such that the concrete wall temperature is maintained below the benchmark value of 65°C for the different boundary conditions imposed. - The RCCS maintains its functionality even with three quarters of the risers blocked or in the event that there is a break in one of the chimney pipes. / MIng (Nuclear Engineering), North-West University, Potchefstroom Campus, 2015
3

Simulation of natural circulation in an air-cooled Reactor Cavity Cooling System using Flownex / Kabelo Albert Sehoana

Sehoana, Kabelo Albert January 2014 (has links)
Nuclear reactors with improved safety concepts are currently being studied within the nuclear engineering community, with a focus on passive safety features. One of these reactor concepts is the Very High Temperature gas-cooled Reactor (VHTR) of which the Reactor Cavity Cooling Systems (RCCS) is seen as an integral and crucial part of the passive safety concept. Considerable validation and development of the necessary software tools is required to perform analysis and designs of these future reactor concepts. The primary objective of this study is to establish a methodology for the creation of an integrated system level process model of a typical air-cooled RCCS in Flownex®, and to illustrate its applicability by simulating different scenarios that illustrate the operational characteristics of such a system. For this purpose, the existing RCCS conceptual design that is being studied by the KAERI was used as the case study. As a start, selected case studies were performed to verify that the Flownex® models were set up correctly to perform natural circulation flows, both in steady and transient conditions, and with radiation, convection and conduction taking part. These are the major typical physical phenomena in the RCCS. The models were compared with EES (Engineering Equation Solver) models of the same geometries and specifications. There was a good agreement between Flownex® and EES model results. After this verification, a simulation model of the integrated RCCS system was developed. The Flownex® models were applied to model selected possible operational scenarios. The major observations from the results are that: - The RCCS carries with it enough heat to the ambient such that the concrete wall temperature is maintained below the benchmark value of 65°C for the different boundary conditions imposed. - The RCCS maintains its functionality even with three quarters of the risers blocked or in the event that there is a break in one of the chimney pipes. / MIng (Nuclear Engineering), North-West University, Potchefstroom Campus, 2015
4

Analysis of the Reactor Cavity Cooling System for Very High Temperature Gas-cooled Reactors Using Computational Fluid Dynamics Tools

Frisani, Angelo 2010 May 1900 (has links)
The design of passive heat removal systems is one of the main concerns for the modular Very High Temperature Gas-Cooled Reactors (VHTR) vessel cavity. The Reactor Cavity Cooling System (RCCS) is an important heat removal system in case of accidents. The design and validation of the RCCS is necessary to demonstrate that VHTRs can survive to the postulated accidents. The commercial Computational Fluid Dynamics (CFD) STAR-CCM+/ V3.06.006 code was used for three-dimensional system modeling and analysis of the RCCS. Two models were developed to analyze heat exchange in the RCCS. Both models incorporate a 180 degree section resembling the VHTR RCCS bench table test facility performed at Texas A&M University. All the key features of the experimental facility were taken into account during the numerical simulations. Two cooling fluids (i.e., water and air) were considered to test the capability of maintaining the RCCS concrete walls temperature below design limits. Mesh convergence was achieved with an intensive parametric study of the two different cooling configurations and selected boundary conditions. To test the effect of turbulence modeling on the RCCS heat exchange, predictions using several different turbulence models and near-wall treatments were evaluated and compared. The models considered included the first-moment closure one equation Spalart-Allmaras model, the first-moment closure two-equation k-e and k-w models and the second-moment closure Reynolds Stress Transport (RST) model. For the near wall treatments, the low y+ and the all y+ wall treatments were considered. The two-layer model was also used to investigate the effect of near-wall treatment. The comparison of the experimental data with the simulations showed a satisfactory agreement for the temperature distribution inside the RCCS cavity medium and at the standpipes walls. The tested turbulence models demonstrated that the Realizable k-e model with two-layer all y+ wall treatment performs better than the other k-e models for such a complicated geometry and flow conditions. Results are in satisfactory agreement with the RST simulations and experimental data available. A scaling analysis was developed to address the distortion introduced by the experimental facility and CFD model in simulating the physics inside the RCCS system with respect to the real plant configuration. The scaling analysis demonstrated that both the experimental facility and CFD model give a satisfactory reproduction of the main flow characteristics inside the RCCS cavity region, with convection and radiation heat exchange phenomena being properly scaled from the real plant to the model analyzed.
5

In Vitro Simulation of Microgravity Induced Muscle Loss Successfully Increases Expression of Key In Vivo Atrophy Markers

Harding, Charles P. 01 May 2019 (has links)
Muscle loss from lack of activity is a serious issue for immobilized patients on Earth and in human spaceflight, where the low gravity environment prevents normal muscle activity. Simulating muscle loss in cultured cells is an important step in understanding how this condition occurs. This work evaluates different means of simulating muscle loss and selects the one that most closely mimics the cellular responses seen in animals and humans. To simulate the microgravity environment of spaceflight, mouse skeletal muscle cells were grown in a rotary cell culture system (RCCS). Growing the cells within a natural gelled substrate was compared against growing them on the surface of small plastic beads. Changes after culture under simulated microgravity were characterized by assessing proteins and genes known to change during muscle loss. The structure of the cells was also evaluated by microscopy. The mouse skeletal muscle cells grown on plastic beads in the RCCS had significant changes in multiple key genes associated with muscle loss and demonstrated physical characteristics expected of mature tissue in live animals. This model is a valuable platform for exploring muscle loss mechanisms and testing new drugs.

Page generated in 0.0386 seconds