Optimisation automatique des incidences des faisceaux par l'algorithme du simplexe et optimisation des Contrôles qualité par la Maitrise Statistique des Processus (MSP) en Radiothérapie Conformationnelle par Modulation d'Intensité (RCMI)

Gerard, Karine 07 November 2008 (has links) (PDF)
La Radiothérapie Conformationnelle par Modulation d'Intensité (RCMI) est aujourd'hui reconnue comme une technique de référence permettant d'augmenter le contrôle local de la tumeur tout en réduisant la dose reçue par les organes à risques avoisinants. Cependant, son développement est freiné par l'étape de préparation du traitement du patient qui nécessite une charge de travail considérable. Dans le but d'augmenter l'efficience de la mise en œuvre d'un traitement, deux axes de travail ont été déterminés.<br />Le premier axe concernait l'optimisation automatique des incidences des faisceaux. Nous avons pour cela mis en œuvre un algorithme (le simplexe) qui a été intégré dans le système de planification de traitement. Il permet, à partir des objectifs dosimétriques fixés par l'utilisateur, de déterminer automatiquement les incidences de faisceaux optimales : irradiant suffisamment le volume cible tout en épargnant les organes à risques avoisinants. En plus d'un gain en temps, les résultats du simplexe ont montré – sur trois patients atteints d'un cancer de l'oropharynx – un gain en qualité par rapport à une sélection manuelle des faisceaux. En effet, pour une couverture du volume cible équivalente voire meilleure, il permet de réduire la dose reçue par les organes à risques.<br />Le second axe concernait l'optimisation des contrôles pré-traitement. Nous avons pour cela utilisé une méthode industrielle : la Maîtrise Statistique des Processus (MSP) afin d'analyser rétrospectivement les résultats des contrôles de la dose absolue effectués avec la chambre d'ionisation au Centre Alexis Vautrin (CAV). Cette étude a montré l'intérêt de la MSP pour renforcer la sécurité des traitements grâce à la mise en place de cartes de contrôle. Elle a également montré que notre processus de délivrance de la dose était stable et statistiquement capable pour les traitements de la prostate, ce qui implique qu'une réduction du nombre de contrôles peut être envisagée pour ce type de traitement au CAV.
2

Apport de la modulation d'intensité et de l'optimisation pour délivrer une dose adaptée aux hétérogénéités biologiques / Contribution of the modulation of intensity and the optimization to deliver a dose adapted to the biological heterogeneities

Kubs, Fleur 19 October 2007 (has links)
Les progrès en imagerie fonctionnelle ouvrent de nouvelles perspectives dans la délimitation des volumes cibles en radiothérapie. Il est envisagé d’adapter les doses d’irradiation sur l’activité tumorale et de réaliser une escalade de dose. Nos objectifs étaient caractériser la détectabilité en TEP, en quantifiant les incertitudes de contour du GTV, de mettre en place la géométrie appropriée, d’évaluer l’impact dosimétrique de ce nouveau protocole et de vérifier la bonne délivrance de cette irradiation. 3 fantômes originaux et 2 fantômes virtuels avec les 3 niveaux de dose recherchés ont été spécialement conçus. Le diamètre de 1cm pour le niveau 3 a pu être atteint. Une escalade de 20Gy a été possible. L’impact dosimétrique sur deux cas réels était satisfaisant. Les tolérances cliniques ont été respectées. Toute la chaîne de traitement a été évaluée et validée. Cependant de telles doses doivent être évaluées avec précaution avant d’être prescrites et des progrès sont attendus en imagerie / The progress in functional imaging opens new perspectives in the delineation of target volumes in radiotherapy. We can intend to adapt the irradiation doses on the tumor activity and to perform a dose escalation. Our objectives were (i) to characterize the TEP thresholding, by quantifying the uncertainties of the target volume contour, (ii) to set up the geometry suited, (iii) to estimate the dosimetric impact of this new protocol and (iv) to verify that dosimetry is perfectly distributed. 3 original phantoms and 2 virtual phantoms containing 3 dose levels were specially created. The diameter of 1cm for the 3rd level was able to be reached. A dose escalation of 20Gy was possible. The dosimetric impact on two real cases was suitable. The clinical tolerances were respected. So all the treatment process was estimated and validated. However such doses should be carefully estimated before being prescribed clinically and progress is also expected in imaging
3

Optimisation automatique des incidences des faisceaux par l'algorithme du simplexe et optimisation des contrôles qualité par la Maîtrise Statistique des Processus (MSP) en Radiothérapie Conformationnelle par Modulation d'Intensité (RCMI) / Automatic optimisation of beam orientations using the simplex algorithm and optimisation of quality control using statistical process control (SPC) for intensity modulated radiation therapy (IMRT)

Gérard, Karine 07 November 2008 (has links)
La Radiothérapie Conformationnelle par Modulation d’Intensité (RCMI) est aujourd’hui reconnue comme une technique de référence permettant d’augmenter le contrôle local de la tumeur tout en réduisant la dose reçue par les organes à risques avoisinants. Cependant, son développement est freiné par l’étape de préparation du traitement du patient qui nécessite une charge de travail considérable. Dans le but d’augmenter l’efficience de la mise en œuvre d’un traitement, deux axes de travail ont été déterminés. Le premier axe concernait l’optimisation automatique des incidences des faisceaux. Nous avons pour cela mis en œuvre un algorithme (le simplexe) qui a été intégré dans le système de planification de traitement. Il permet, à partir des objectifs dosimétriques fixés par l’utilisateur, de déterminer automatiquement les incidences de faisceaux optimales : irradiant suffisamment le volume cible tout en épargnant les organes à risques avoisinants. En plus d’un gain en temps, les résultats du simplexe ont montré – sur trois patients atteints d’un cancer de l’oropharynx – un gain en qualité par rapport à une sélection manuelle des faisceaux. En effet, pour une couverture du volume cible équivalente voire meilleure, il permet de réduire la dose reçue par les organes à risques. Le second axe concernait l’optimisation des contrôles pré-traitement. Nous avons pour cela utilisé une méthode industrielle : la Maîtrise Statistique des Processus (MSP) afin d’analyser rétrospectivement les résultats des contrôles de la dose absolue effectués avec la chambre d’ionisation au Centre Alexis Vautrin (CAV). Cette étude a montré l’intérêt de la MSP pour renforcer la sécurité des traitements grâce à la mise en place de cartes de contrôle. Elle a également montré que notre processus de délivrance de la dose était stable et statistiquement capable pour les traitements de la prostate, ce qui implique qu’une réduction du nombre de contrôles peut être envisagée pour ce type de traitement au CAV / Intensity Modulated Radiation Therapy (IMRT) is currently considered as a technique of choice to increase the local control of the tumour while reducing the dose to surrounding organs at risk. However, its routine clinical implementation is partially held back by the excessive amount of work required to prepare the patient treatment. In order to increase the efficiency of the treatment preparation, two axes of work have been defined. The first axis concerned the automatic optimisation of beam orientations. We integrated the simplex algorithm in the treatment planning system. Starting from the dosimetric objectives set by the user, it can automatically determine the optimal beam orientations that best cover the target volume while sparing organs at risk. In addition to time sparing, the simplex results of three patients with a cancer of the oropharynx, showed that the quality of the plan is also increased compared to a manual beam selection. Indeed, for an equivalent or even a better target coverage, it reduces the dose received by the organs at risk. The second axis of work concerned the optimisation of pre-treatment quality control. We used an industrial method: Statistical Process Control (SPC) to retrospectively analyse the absolute dose quality control results performed using an ionisation chamber at Centre Alexis Vautrin (CAV). This study showed that SPC is an efficient method to reinforce treatment security using control charts. It also showed that our dose delivery process was stable and statistically capable for prostate treatments, which implies that a reduction of the number of controls can be considered for this type of treatment at the CAV
4

Apport de la modulation d'intensité et de l'optimisation pour délivrer une dose adaptée aux héterogénités biologiques

Kubs, Fleur 19 October 2007 (has links) (PDF)
Les progrès récents en imagerie fonctionnelle par Tomographie d'Emission de Positons (TEP) ouvrent de nouvelles perspectives dans la délimitation des volumes cibles en radiothérapie. L'information fonctionnelle est capitale, on peut envisager d'adapter les doses d'irradiation sur l'activité tumorale (AT) et de réaliser une escalade de dose. Nos objectifs étaient caractériser la détectabilité en TEP, en quantifiant les incertitudes de contour du volume cible en fonction de la taille des lésions et du seuillage appliqué, de mettre en place la géométrie appropriée pour réaliser une forte irradiation hautement précise basée sur l'AT, d'évaluer l'impact dosimétrique de ce nouveau protocole et de vérifier la bonne délivrance de cette irradiation. Trois fantômes originaux ont été spécialement conçus pour satisfaire aux contraintes rencontrées, ainsi que deux fantômes virtuels contenant les 3 niveaux de dose recherchés (niveau3=AT). Nos résultats ont montré l'importance de l'effet seuil-volume sur la planification en radiothérapie. Afin d'utiliser cette méthode d'irradiation, le diamètre de 1cm pour le 3ème niveau a pu être atteint. Une escalade de 20Gy a été possible entre le 2ème (70Gy) et le 3ème niveau (90Gy). L'impact dosimétrique évalué sur deux cas réels était satisfaisant (augmentation de COIN de 0,6 à 0,8 et diminution de NTCP d'un facteur 5). En dosimétrie absolue et relative, les tolérances cliniques ont été respectées. Ainsi toute la chaîne de traitement, allant du diagnostic, avec la TEP pour déceler l'AT, au traitement du patient effectué au préalable sur fantôme, en passant par la balistique et le calcul de dose, a été évaluée et validée selon notre objectif d'adapter l'irradiation aux hétérogénéités biologiques. Cependant de telles hautes doses doivent être évaluées avec précaution avant d'être prescrites en clinique, et des progrès sont aussi attendus en imagerie, puisque la taille minimale que l'on peut irradier est à la limite de la résolution TEP.
5

Application des innovations technologiques de la radiothérapie au traitement des cancers ORL : résultats cliniques de la radiothérapie conformationnelle avec modulation d'intensité : applications de l'imagerie embarquée en radiothérapie ORL / Radiation therapy technology innovations applied to the treatment of head and neck patients : Clinical results of Intensity Modulated Radiotherapy (IMRT) : Contribution of Image Guided Radiotherapy (IGRT) in the management of head and neck patients treated with IMRT

Graff-Cailleaud, Pierre 10 November 2011 (has links)
Dans une démarche d'évaluation rigoureuse des innovations technologiques de la radiothérapie, notre travail de thèse a été construit autours de 2 thématiques : 1) Evaluation clinique des résultats de la radiothérapie conformationnelle avec modulation d'intensité (RCMI) appliquée au traitement des cancers ORL. La première étude rapporte les conclusions d'un enregistrement prospectif monocentrique du devenir au long cours des patients ORL traités par RCMI. Le contrôle locorégional est excellent et les niveaux de toxicité faibles. Des recommandations dosimétriques (dose aux parotides) adaptées à nos pratiques ont été établies. La deuxième étude rapporte les résultats d'une comparaison nationale multicentrique de la qualité de vie des patients traités pour un cancer ORL, soit par radiothérapie conventionnelle, soit par RCMI. Le bénéfice de la RCMI est remarquable dans les domaines du confort de la sphère buccale et de la prise alimentaire orale. 2) Evaluation de l'apport de l'imagerie embarquée (Cone Beam CT ou CBCT) dans la prise en charge des patients traités par RCMI pour un cancer ORL. Un premier projet propose, sur un panel de patients ORL traités par RCMI, le contrôle qualité de la distribution de la dose réellement délivrée. Le retentissement dosimétrique des variations anatomiques est discuté. L'apport d'outils dosimétriques spécifiques est étudié. Le second projet a pour objectif de quantifier la mobilité relative des régions anatomiques qui composent la sphère ORL et d'étudier l'impact dosimétrique lié au choix de différentes procédures de recalage. Une recommandation sur les modalités d'utilisation des images CBCT a pu être proposée. / Numerous and exciting technological innovations were recently developed in radiotherapy. We aimed to assess benefits in two specific fields. 1) Clinical results of Intensity Modulated Radiotherapy (IMRT) applied to the treatment of Head and Neck (H&N) patients. The first study was a long-term monocentric prospective registration of all H&N patients treated with IMRT in our institution. Locoregional control was excellent and toxicities limited. Recurrences were in-field. Dosimetric recommendations (parotids mean dose) were established. The second study assessed the impact of IMRT on health-related quality of life for H&N patients through a multicentric matched-pair comparison with conventional radiotherapy. Outstanding benefits were observed particularly in the fields of salivary dysfunction and oral discomfort. 2) Contribution of Image Guided Radiotherapy (IGRT) in the management of H&N patients treated with IMRT. The first study was a monitoring of delivered dose, using 3D dose recalculation from Megavoltage Cone-Beam CT (CBCT), as a quality assurance measure of a panel of H&N IMRT patients aligned with IGRT. Dosimetric consequences of anatomical changes were assessed. Contribution of color-coded MVCBCT dose-difference maps was studied. The aim of the second study was to quantify the inherent relative mobility between anatomic regions of the H&N area and to assess the dosimetric impact of several different matching procedures. Recommendations for the use of CBCT images in a daily practice were established.