• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • Tagged with
  • 34
  • 34
  • 34
  • 34
  • 30
  • 11
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da resistência de união entre infra-estrutura de zircônia e cerâmica de cobertura comparado com um sistema metalo-cerâmico

Carlucci, Cristiano Lages January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000425713-0.pdf: 1781396 bytes, checksum: 7eeb594432bb477d3935d002b3c3bfbb (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this in vitro study was to evaluate the bond strength interface between the veneering and core zirconia ceramic of a system metal free compared to metal-ceramic system. For this, 40 blocks were made of zirconia (Procera Zirconia), where 32 without color and 8 color have A2) and 8 blocks of metal (alloy Viron 99), all the dimensions (10 x 10 x 2 mm). Samples of zirconia were divided into 5 groups (8 each), and received different preparations: Group 1 (zirconia without color): application of the dentin; Group 2 (zirconia A2 color): application of the dentin; Group 3 (zirconia without color): application of liner + dentin; Group 4 (zirconia without color): application of dentin + liner on the inner surface; Group 5 (zirconia without color): wear diamond drill + liner + dentin. As a control group: metal-ceramic (IPS Dsign Viron 99 + dentin A2). After sintering of ceramics according to the manufacturer, the samples were subjected to analysis of shear strength tests performed on machine EMIC DL 2000, where results were obtained in MPa. Through photographs and SEM with magnitude of 37X, 200X and 2000X as the type of failure that occurred at the interface core and veneering ceramic. When submitting the results to the ANOVA, it was possible to observe that there were statistically significant differences between groups (p=0,000). According to Tukey's test, the control group had the highest values of tensile bond strength, statistically different (P<0. 05) than other groups of zirconia. The groups of zirconia showed no statistical difference between them (p>0. 05). Group 2 had the highest average among the zirconia and group 4 had the lowest average of all groups. The flaws found in the joint interface were 100% in all samples and only 1 sample of group 2 it was cohesive failures in the core of zirconia. It was concluded that the control group showed a tensile bond strength approximately 50% higher than all groups of zirconia tested. / O objetivo deste estudo in vitro foi avaliar a resistência de união entre infraestrutura de zircônia e cerâmica de cobertura de um sistema livre de metal comparado com um sistema metalo-cerâmico. Para isso, foram confeccionados 40 blocos de zircônia (Procera Zirconia), onde 32 não possuíam cor e 8 possuíam cor A2) e 8 blocos metálicos (liga Viron 99), todos nas dimensões (10 x 10 x 2 mm). As amostras de zircônia foram divididas em 5 grupos (8 em cada), e receberam diferentes tratamentos: Grupo 1 (zircônia s/ cor): aplicação da dentina; Grupo 2 (zircônia c/ cor): aplicação da dentina; Grupo 3 (zircônia s/ cor): aplicação do liner + dentina; Grupo 4 (zircônia s/ cor): aplicação do liner + dentina na superfície interna; Grupo 5 (zircônia s/ cor): desgaste com broca diamantada + liner + dentina. Como Grupo Controle: metalo-cerâmica (viron 99 + IPS Dsign dentina A2). Após sinterização das cerâmicas de acordo com o fabricante, as amostras foram submetidas ao teste de resistência ao cisalhamento realizados em máquina de ensaios EMIC DL 2000, onde os resultados foram obtidos em MPa. Através de fotografias e de MEV com magnitude de 37X, 200X e 2000X foi verificado o tipo de falha que ocorreu na interface infra-estrutura e cerâmica de cobertura. Ao submeter os resultados ao teste ANOVA, foi possível observar que houve diferenças estatisticamente significantes entre os grupos (p=0,000). De acordo com teste de Tukey, o grupo controle obteve os maiores valores de resistência de união, estatisticamente diferente (p<0,05) aos demais grupos de zircônia. Os grupos de zircônia não apresentaram diferença estatística entre si (p>0,05). O grupo 2 apresentou a maior média entre os grupos de zircônia e o grupo 4 apresentou a menor média de todos os grupos testados. As falhas encontradas na interface foram 100% mistas em todas amostras e apenas 1 amostra do grupo 2 constatou-se falhas coesivas na infra-estrutura de zircônia. Concluiu-se que o grupo controle mostrou uma resistência de união aproximadamente 50% maior que todos os grupos de zircônia testados.
12

Análise de metodologias de microdureza aplicadas a compósitos: é possível comparar resultados utilizando-se diferentes protocolos?

Barbosa, Gustavo Frainer January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000427785-0.pdf: 701572 bytes, checksum: 6d68289fb0a8c4a345e9c231cfaa8675 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Objective: Firstly, to evaluate correlation between load and dwell time in composite resin microhardness tests, using Vickers and Knoop mechanic test methods. Secondly, to correlate time and load on Knoop microhardness test over a composite resin, and to show, with the obtained results, whether composite resin conversion degree comparison is possible through the tests. Materials and Methods: Resin Grandio (Voco, Cuxhaven, Germany), shade A2, was used to make the samples. Ninety (90) samples were made on a six-(6)-mm-diameter by three-(3)-mm-deep polytetrafluorethylene matrix, where two equidistant increments were each photocured for 20s by the LED device (Celalux, Voco, Cuxhaven, Germany, with 800 mW/cm2). The samples were randomly divided into three groups according to the load factor. Groups I, II and III received loads at 50g, 100g and 500g respectively. These groups were divided into nine subgroups according to the deal time (15s, 30s, 45s). Each sample received indentations from a Shimadzu HMV tester (Shimadzu, Kyoto, Japan). The results were submitted to a two-way ANOVA with fixed factors (load and dwell time), and to the post-hoc Tukey multiple comparison test at α = 0. 05.Results: Significant differences were recorded between groups for each methodology, Vickers and Knoop (p<0. 001). Among the Vickers (VHN) tested samples, the average recorded ranged from 164. 94 (50g for 45s) to 210. 33 (100g for 45s). Knoop microhardness (KHN) ranged from 128. 92 (500g 45s) to 184. 26 (100g 15s). For both methodologies, both load and dwell time were statistically significant (p<0. 001), this way showing that different loads and dwell time influence the microhardness of resins. Conclusion: Firstly, this study demonstrated that correlating both Vickers and Knoop microhardness test results is not recommended, and similar protocols must be applied to allow comparisons among the different studies that use the same kind of test. Secondly, this study demonstrated that Knoop microhardness test results is not recommended for composite resin conversion degree comparisons, and similar protocols should be applied to allow this kind of correlation. / OBJETIVO: Primeiramente, avaliar, em uma resina composta, a correlação existente, em testes de microdureza, entre os fatores carga e tempo de aplicação, utilizando-se os métodos de ensaio mecânico Vickers e Knoop. Em segundo lugar, avaliar, em uma resina composta, os fatores carga e tempo de aplicação no teste de microdureza Knoop, e mostrar, com os resultados obtidos, quando é possível, através dos testes, fazer uma comparação com o grau de conversão da resina composta. MATERIAIS E MÉTODOS: Resina Grandio (Voco, Cuxhaven, Alemanha), cor A2, foi utilizada para confeccionar as amostras. Noventa (90) amostras foram feitas em uma matriz de politetrafluoretileno com seis (6) mm de diâmetro por três (3) mm de profundidade, onde dois incrementos equidistantes foram fotopolimerizados por 20s cada um através de um dispositivo LED (Celalux, Voco, Cuxhaven, Alemanha, com 800 mW/cm2). As amostras foram divididas aleatoriamente em três grupos de acordo com o fator carga. Os grupos I, II e III receberam cargas de 50g, 100g e 500g, respectivamente. Estes grupos foram divididos em nove subgrupos de acordo com o fator tempo de aplicação (15s, 30s, 45s). Cada amostra recebeu edentações de um dispositivo Shimadzu HMV tester (Shimadzu, Kioto, Japão). Os resultados foram analisados estatisticamente através de ANOVA com fatores fixos (carga e tempo de aplicação), e ao teste de comparações múltiplas de Tukey (α = 0. 05).RESULTADOS: Diferenças significativas foram encontradas entre os grupos para cada metodologia, Vickers e Knoop (p<0. 001). Entre as amostras testadas com a metodologia Vickers (VHN), a média encontrada variou de 164. 94 (50g 45s) até 210. 33 (100g 45s). Os valores de microdureza para a metodologia Knoop (KHN) variaram de 128. 92 (500g 45s) até 184. 26 (100g 15s). Para ambas as metodologias, tanto o fator tempo e o fator tempo de aplicação foram estatisticamente significantes (p<0. 001), isto mostra que diferentes cargas e tempos de aplicação influenciam na microdureza das resinas. CONCLUSÃO: Primeiramente, este estudo demonstrou que correlacionar os resultados de testes de microdureza Vickers and Knoop não é recomendado, e protocolos similares devem ser aplicados a fim de permitir comparações entre diferentes estudos que utilizam o mesmo tipo de teste. Em Segundo lugar, este estudo demonstrou que os resultados de microdureza Knoop não são recomendados para comparações com o grau de conversão das resinas compostas, e protocolos similares devem ser aplicados a fim de permitir este tipo de correlação.
13

Resistência de união de pinos intrarradiculares cimentados à dentina com e sem tratamento com laser de Nd:YAG

Simon, Rosana Simões January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000425443-0.pdf: 137763 bytes, checksum: 07c751d4d7073c523bf8aaedf5f3b302 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Aims: to evaluate the bond strength of fibre-posts luted with two kind of resin cements to dentin of the root canal treated or not with Nd:YAG laser associated to phosphoric acid. Materials and methods: Sixty one-root teeth with similar morphology and length were submitted to the endodontic treatment with manual instrumentation. After, it were divided into six groups according to the luting protocol of the fibre post (n=10): G1 –RelyX Unicem; G2 – Nd:YAG laser + self-etching luting cement RelyX Unicem; G3 – 37% phosphoric acid gel (AG37%) + RelyX ARC; G4 – Nd:YAG laser + AG37% + RelyX ARC; G5 – etching with the Experimental Solution (ES): Patent number BRPI0903355-6) + RelyX ARC; e G6 – Nd:YAG laser + SS solution + RelyX ARC. The Nd:YAG laser were irradiated with the following protocol: 1064 nm, 60 mJ, 15 Hz and 47. 77 mJ/cm2, 1 min. Afterwards, the teeth with the luted fibre posts were stored in distilled water at 37ºC for 1 week. Next, the roots were sectioned in thirds – cervical, medial and apical – being the slices submitted to the push-out bond strength test. Results: the SS solution group associated to RelyX ARC presented together with the Nd:YAG laser associated to the RelyX Unicem the higher bond strength considering all thirds. Notwithstanding, the phosphoric acid gel associated to the RelyX ARC presented the lower bond strength together with the Relyx Unicem control group. Conclusion: The use of the ES solution increased significantly the bond strength of the RelyX Arc to dentin of the root canal. / Objetivos: Avaliar a resistência de união de pinos de fibra de vidro cimentados à dentina radicular tratada com laser de Nd:YAG, ácido fosfórico gel a 37% ou com uma solução experimental (PATENTE solicitada ao INPI nº PI0903355-6), utilizando dois tipos de cimentos resinosos. Materiais e métodos: Sessenta dentes unirradiculares com morfologia e comprimentos semelhantes foram submetidos ao tratamento endodôntico tradicional ou com laser de Nd:YAG, com instrumentação manual. Após, os dentes foram divididos em seis grupos de acordo com o protocolo de cimentação do pino de fibra de vidro (n=10): G1 –RelyX Unicem; G2 –laser Nd:YAG + RelyX Unicem; G3 –ácido fosfórico gel a 37% (AG37%) + RelyX ARC; G4 –laser Nd:YAG + AG37% + RelyX ARC; G5 – condicionamento com solução experimental (PATENTE solicitada ao INPI nº PI0903355- 6) + RelyX ARC; e G6 – laser Nd:YAG + solução experimental (PATENTE solicitada ao INPI nº PI0903355-6) + RelyX ARC. O laser de Nd:YAG foi irradiado com o seguinte protocolo: 1064 nm, 60 mJ, 15 Hz, 47,77 mJ/cm2 durante 1 min. Os dentes com os pinos cimentados foram armazenados em água destilada a 37ºC por 7 dias. Após esse período, as raízes foram seccionadas em terços cervical, médio e apical, sendo as fatias submetidas ao ensaio de resistência de união por push-out. Ainda, seis dentes foram submetidos aos tratamentos de superfície e levados à microscopia eletrônica de varredura e análise EDS. Resultados: o grupo da solução experimental (PATENTE solicitada ao INPI nº PI0903355- 6) associada ao cimento resinoso RelyX ARC apresentou juntamente com o grupo do laser 4 de Nd:YAG associado ao cimento RelyX Unicem a maior resistência de união considerando todos os terços radiculares. Por sua vez, o ácido fosfórico gel associado ao cimento RelyX ARC apresentou a menor resistência de união juntamente com o grupo do RelyX Unicem. Conclusão: O uso da solução experimental (PATENTE solicitada ao INPI nº PI0903355-6) aumentou significativamente a resistência de união do cimento resinoso RelyX ARC à superfície dentinária do conduto radicular, assim como a irradiação por laser, de uma maneira geral, também aumentou a resistência de união particularmente nos grupos G2 e G4.
14

Efeito da vibração sônica em adesivo autocondicionante e adesivo de frasco único na resistência de união à dentina

Cavazzola, Fernanda de Cássia Mortari January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000410352-0.pdf: 1564649 bytes, checksum: f945ade3456419a19d997c80c2fb43fc (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Objetivo: Verificar se a aplicação dos sistemas adesivos, por meio da vibração do aparelho sônico, aumenta a resistência de união do sistema adesivo à dentina. A hipóse nula é que a resistência de união nos sistemas adesivos Single Bond e Clearfil SE Bond é similar tanto nos grupos controle quanto nos grupos que receberem tratamento sônico. Materiais e Método: Doze terceiros molares extraídos hígidos foram incluídos em resina acrílica autopolimerizável com a parte coronária do dente voltada para a sua parte superior, onde foi realizada a remoção do esmalte com lixas de carbeto de silício de granulação #600, preparando uma superfície dentinária lisa. Os dentes foram divididos em 4 grupos, onde cada sistema adesivo utilizado foi aplicado de acordo com as instruções do fabricante (aplicação dinâmica manual) e com a vibração de aparelho sônico por um dispositivo adaptador para pincel microbrush. Após a técnica adesiva, foi aplicada resina composta microhíbrida com altura de 6mm. Após o corpo de prova foi incluído completamente pela resina acrílica autopolimerizável estabilizando o material restaurador e interface adesiva ao cilíndro para os cortes seriados. Após isso, estes cilindros foram armazenados em água destilada em uma estufa de cultura a 37°C por 24 horas. Passado este período, foram confeccionados os corpos de prova para o ensaio de resistência de união por microtração com cada cilindro. Os dados obtidos foram submetidos ao teste Kolmogorov-Smirnov para verificação de normalidade. A seguir, os dados foram comparados com o teste ANOVA e Tukey (alpha=0,05). A analise estatística da fractografia, foi submetida ao teste Exato de Fisher, com nível de significância de 5% (p<0,05). Resultados: A resistência de união com a aplicação ativada pela vibração sônica foi maior do que a aplicação dinâmica manual em ambos os sistemas adesivos, apresentando diferenças estatisticamente significativas nos diferentes grupos de um mesmo adesivo. Conclusão: A utilização da aplicação sônica é um método eficaz para a otimização da resistência de união em dentina.
15

Avaliação e comparação de instrumentos endodônticos rotatórios de NiTi antes e após o uso clínico

Weis, Adriano January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000428355-0.pdf: 4558366 bytes, checksum: 162a6f78756da7890951b745bc913a80 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The objective of this study was to evaluate and to compare rotatory instruments of NiTi before and after the clinical use. Twenty-four groups of rotatory instruments of NiTi of the ProTaper system (Dentsply-Maillefer, Ballaigues, Switzerland) were divided in two groups in a random way. The instruments of the group 1 (n=12) were stored for subsequent accomplishment of the mechanical tests. The instruments of the group 2 (n=12) were directed to a single endodontist, who used each group in the preparation of ten radicular canals. After the collection of the instruments, all the S1, S2 and F1 alloys from the two groups, were tested related to the resistance to the cyclical fatigue. For this test a simulator of curved canal of stainless steel was used with 1,5mm of internal diameter, angle of 90 degrees and ray of 6mm where the instruments were introduced with speed of 350 rotations per minute (RPM) until happening the fracture of the same ones. The passed time to the fracture happened was analyzed and transformed in RPM. The size of the fragments was also analyzed. The data were analyzed using the normality test of Kolmogorov-Smirnov at the level of significance of 1% and they were analyzed with ANOVA of two factors (RPM and size of the fragment), following by the Tukey test at the level of significance of 5%.The obtained results showed significant difference for the factor RPM (p=0. 008), but not significant for the factor of the fragment (p=0. 12). Average values of RPM were from 641 to the new instrument S1 (±127, 92); 476 to the used instrument S1 (± 182, 92); 545 to new instrument S2 (±66, 61); 504 to used instrument S2 (±150. 01); 453 to new instrument F1 (±53, 18) and 433 to used instrument F1 (±153, 43). The average values of the fragments (mm) recorded were 6, 41 (new S1); 7, 46 (used S1); 6, 95 (new S2); 7, 35 (used S2); 7, 30 (new F1) and 7, 09 (used F1). All the instruments were analyzed in a lateral view and in the fracture surface in electronic microscopy of scintiscan (EMS) to qualitative analysis of the fractured instruments. / O objetivo deste estudo foi avaliar e comparar instrumentos rotatórios de NiTi antes e após o uso clínico. Vinte e quatro conjuntos de instrumentos rotatórios de NiTi do sistema ProTaper (Dentsply-Maillefer, Ballaigues, Suiça) foram divididos em dois grupos de forma aleatória. Os intrumentos do grupo 1 (n=12) foram armazenados para posterior realização dos testes mecânicos. Os intrumentos do grupo 2 (n=12) foram encaminhados para um único endodontista, o qual utilizou cada conjunto no preparo de dez canais radiculares. Após coleta dos instrumentos, todas as limas S1, S2 e F1 dos dois grupos, foram testadas quanto a sua resistência a fadiga cíclica. Para este teste foi utilizado um simulador de canal curvo de aço inoxidável com 1,5mm de diâmetro interno, ângulo de 90 graus e raio de 6mm onde os instrumentos foram introduzidos com velocidade de 350 rotações por minuto (RPM) até acorrer a fratura dos mesmos. O tempo transcorrido para que ocorresse a fratura foi analisado e transformado em RPM. O tamanho dos fragmentos também foi analisado. Os dados foram analisados utilizando o teste de normalidade de Kolmogorov-Smirnov ao nível de significância de 1% e foram analisados com ANOVA de dois fatores (RPM e tamanho do fragmento), seguido do teste de Tukey ao nível de significância de 5%.Os resultados obtidos mostraram diferença significativa para o fator RPM (p=0,008), mas não significativa para o fator tamanho do fragmento (p=0,12). Valores médios de RPM obtidos foram de 641 para o instrumento S1 novo (±127,92); 476 para S1 usado (± 182,92); 545 para S2 novo (±66,61); 504 para S2 usado (±150. 01); 453 para F1 novo (±53,18) e 433 para F1 usado (±153,43). Os valores médios dos fragmentos (mm) registrados foram de 6,41 8 (S1 nova); 7,46 (S1 usada); 6,95 (S2 nova); 7,35 (S2 usada); 7,30 (F1 nova) e 7,09 (F1 usada). Todos os instrumentos foram analisados em uma vista lateral e na superfície de fratura em microscopia eletrônica de varredura (MEV) para análise qualitativa dos instrumentos fraturados.
16

Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional

Herbstrith Segundo, Regênio Mahfuz January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000388162-0.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to compare and evaluate, through 3D finite element analysis, strain distribution generate by simulated loads over implants, abutments and metal ceramic crowns models in first molars region. The analysis were executed in four 3D models: model 1 and 2 with external butt joint, with gold and titanium abutment screw, respectively, model 2 and 3 with internal butt joint, with gold and titanium abutment screw, respectively, the standard load was 382N with two different angulations, 90º to occlusal surface and 15º to implant axis, and in two distinct points 4 and 6mm of the implant center, in ten different observation points on the implantabutment- screw set. The results suggested that in a general way, the internal butt joint models (3 and 4) showed a better mechanic behavior related to strain distribution along the implant-abutment-screw set. On the models 1 and 2, the abutment screw material had a great influence on the strain distribution. On the other hand, models 3 and 4 have no such behavior. / O objetivo deste estudo foi avaliar e comparar qualitativamente, através de análise por elementos finitos com modelo 3D, a distribuição das tensões geradas por cargas simuladas sob modelos de implantes, pilares, coroas protéticas metalocerâmicas na região de primeiros molares. As análises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe protético tipo hexágono externo e parafuso de pilar de ouro e titânio respectivamente, modelo 3 e modelo 4 com encaixe tipo hexágono interno e parafuso de pilar de ouro e titânio respectivamente, a carga aplicada foi padronizada em 382N com duas angulações diferentes, inclinações de 90º com a superfície oclusal e de 15º em relação ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observação no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mecânico em relação a distribuição de tensões ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar é feito influencia na distribuição de tensões, por outro lado, nos modelos 3 e 4 isto não foi observado.
17

Propriedades mecânicas de resinas compostas com nanopartículas

Rosa, Rogério Simões January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:26Z (GMT). No. of bitstreams: 2 000427363-0.pdf: 529456 bytes, checksum: 061439668cdb3da163cb071f3d708111 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: The increasing demands in esthetic dentistry have led to the development of resin composite materials for direct restorations with improved physical and mechanical properties. The latest development in this field has been the introduction of nanoparticles only (nanofilled) or microhybrid and nanomeric particles (nanohybrid) in inorganic matrix. Objective: Evaluate the mechanical behavior of one nanofilled (Filtek Supreme XT - 3M ESPE) and two nanohybrid (Esthet X-Dentsply, Grandio-Voco) composites with enamel and body shades (A2).Background data: The real innovation that implies better mechanical behavior is the nanofiller’s possibility to improve the load of the inorganic phase in 80 Wt% when compared to microfilled composites 50 Wt% for example. Methods: Ten samples of each material were submitted to compressive strength, flexural strength and diametral tensile strength test in an universal testing machine. The flexural modulus test was calculated based on flexural strength results. Ten samples of each group were submitted to knoop microhardness test. One sample of each material were submitted to nanohardness and elasticity modulus. The results were submitted to ANOVA and Tukey statistical tests (α=0. 05). One sample of each group was used in order to register the inorganic weight filler content. Results: An improved mechanical behavior of Grandio was observed for flexural modulus, knoop microhardness, nanohardness, elasticity modulus and weight filler content. For diametral tensile strength Grandio and Filtek Supreme XT obtained higher averages. The tested composite resins ranged similar medias for compressive strength. For flexural strength Filtek Supreme XT and Esthet X showed higher results. Conclusions: The composite resin weight filler content is directly correlated to her mechanical behavior. The filler size and shape of composite resins seemed to be a fine tuning factor for the determination of elasticity modulus. Larger filler sizes tend to render the material stiffer and irregular filler shapes result in higher modulus values. / Introdução: A demanda por odontologia estética conduziu ao desenvolvimento de resinas compostas com melhores propriedades físicas e mecânicas. Em consequência disso, surgiram as resinas compostas que apresentam somente nanopartículas (nanoparticuladas) e as que apresentam partículas nanométricas e microhíbridas (nanohíbridas) em sua matriz inorgânica. Objetivo: Avaliar o comportamento mecânico de uma resina composta nanoparticulada (Filtek Supreme XT - 3M ESPE) e de duas nanohíbridas (Esthet XDentsply, Grandio-Voco) com cores de esmalte e de dentina (A2).Contexto da pesquisa: A grande inovação que gera um melhor comportamento mecânico ao material é a possibilidade de aumentar seu conteúdo em peso de carga inorgânica para 80%, ao passo que as microparticuladas apresentam 50%.Metodologia: Dez amostras de cada resina composta foram submetidas aos testes de resistência à compressão, resistência flexural, resistência à tração diametral numa máquina de ensaio universal. Os dados do teste de módulo flexural foram obtidos a partir dos resultados de resistência flexural. Dez amostras de cada resina composta foram submetidas ao teste de microdureza knoop. Uma amostra de cada material foi submetida aos testes de nanodureza e de módulo de elasticidade. Os resultados foram analisados estatisticamente através de ANOVA e de teste de Tukey (α=0,05). Uma amostra de cada resina composta foi utilizada para registrar seu conteúdo em peso de carga. Resultados: Após a análise estatística das médias, observou-se que a resina composta Grandio apresentou melhor comportamento mecânico para os testes de módulo flexural, microdureza knoop, nanodureza, módulo de elasticidade e conteúdo em peso de carga. No que tange à resistência à tração diametral, Grandio e Filtek Supreme XT obtiveram as maiores médias. As três resinas compostas testadas atingiram médias similares estatisticamente para resistência à compressão. No que se refere à resistência flexural, Filtek Supreme XT e Esthet X apresentaram as maiores médias. Conclusões: O conteúdo de carga em peso das resinas compostas tem relação direta com suas propriedades mecânicas. O tamanho e a forma das partículas de carga tendem a influenciar no módulo de elasticidade. Partículas maiores tendem a dar mais resistência ao material e as de formatos irregulares tornam o material com maiores valores de módulo de elasticidade.
18

Avaliação da influência do tratamento dentinário na adesão de cimento resinoso auto-adesivo

Gruendling, Álvaro January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2 000410872-0.pdf: 1717876 bytes, checksum: bc2f5803d0c8fa42f01af8f0a4f6b3ae (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of dentin surface treatment in the shear bond strength using self-adhesive luting cement. Mandible bovine incisors were used. The teeth crowns were cut in a 1cm² cube shape and included in a plastic tube (PVC) using self cured with acrylic resin. The enamel was removed with manual abrasive strip papers until dentin surface was exposed. The surfaces were then divided in 5 groups with 15 samples each, according to the surface treatment arrived ; group 1 : control; group 2 : aluminum oxide sandblasting; group 3 ; sodium carbonate air polishing; group 4; EDTA; group 5 ; poliacrylic acid. The self-adhesive luting cement used was Rely X Unicem (3M ESPE). After cement settlement, the samples were stored in a 37º C, 100% relative humidity for 7 days. The tests were performed using an EMIC DL 2000 test machine and the obtained results in MPa. The type of failure in the interface between dentin and luting cement was checked using 50x magnitude SEM. The results were submitted to ANOVA test and statistical differences were found among the groups (p=0. 007). According to the Tukey test, the aluminum oxide sandblasting group showed the higher values for shear bond strength what happened to be statistically significant (p<0. 05) comparing to all other groups analyzed. Furthermore, the results found for control group, poliacrylic acid group and EDTA group did not differ statistically (p>0. 05). The sodium carbonate group also did not differ from none of the groups and the EDTA group showed the lowest values for shear bond strength. The breakdowns found in the interfaces were characterized as mixed failures and only the aluminum oxide group presented dentin cohesive failures. The results concluded that aluminum oxide sandblasting determines the highest shear bond strength between dentin and luting cement. / Este estudo teve como objetivo avaliar a influência do tratamento da superfície dentinária na resistência de união ao cisalhamento com o uso de um cimento resinoso auto-adesivo. Para tal, foram utilizados 75 incisivos inferiores bovinos, que tiveram a coroa clínica seccionada em área quadrangular de 1 cm² e incluídos em um tubo de PVC, preenchido com resina acrílica auto-polimerizável. O esmalte foi desgastado, expondo a superfície dentinária com lixas de carbeto de silício de granulação 180, 220 e 400, usadas sequencialmente. As amostras foram divididas em 5 grupos, escolhidas aleatoriamente, de acordo com o tratamento a que foram submetidas: Grupo 1: controle; Grupo 2: jateamento com óxido de alumínio; Grupo 3: jateamento com bicarbonato de sódio; Grupo 4: EDTA; Grupo 5: ácido poliacrílico. O cimento resinoso auto-adesivo utilizado foi Rely X Unicem (3M-ESPE). Após inserção do cimento, os corpos-de-prova foram armazenados em umidade 100% a 37ºC por 7 dias. Os ensaios de resistência ao cisalhamento foram realizados em máquina de ensaios EMIC DL 2000 e os resultados obtidos em MPa. Através da MEV com magnitude de 50X, foi verificado o tipo de falha que ocorreu na interface dentina/cimento. Ao submeter os resultados ao teste ANOVA, foi possível observar que houve diferenças estatisticamente significantes entre os grupos (p = 0,007). De acordo com teste de Tukey, o grupo óxido de alumínio obteve os maiores valores de resistência de união, estatisticamente diferente (p<0,05) em relação aos grupos controle, ácido poliacrílico e EDTA, que por sua vez não diferiram entre si (p>0,05). O grupo bicarbonato de sódio não diferiu de nenhum grupo e o grupo EDTA obteve os menores valores de resistência de união. As falhas encontradas na interface foram caracterizadas como mistas, e somente o grupo óxido de alumínio apresentou presença de falhas coesivas em dentina. Concluiu-se que o jateamento com óxido de alumínio determinou uma maior resistência de união ao cisalhamento entre substrato dentinário/cimento.
19

Diferentes tipos de substrato dentinário podem influenciar a resistência de união em cimento resinoso autoadesivo?

Scheid, Patrícia Alves January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:36Z (GMT). No. of bitstreams: 2 000430602-0.pdf: 3992171 bytes, checksum: dbc119f68b2383c9f1f45cacf8eaf454 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was evaluated the influence of different dentin substrate on the microtensile bond strength of a self-adhesive resin cement. Fifty human molars were selected, twenty-five teeth with coronal dentin caries and twenty-five teeth with old amalgam restorations. Teeth with dentin caries were ground with #100 silicon carbide paper under running water until the removal carie dentin remaining a caries- affected dentin. Teeth with old amalgam restorations followed the same protocol until the removal restoration exposing a discolored dentin. Teeth without caries-affected or discolored dentin surrounded by sound dentin were discarded. Radiographs were taken of the teeth in order to select those with remaining dentin around 2 to 3 mm. The selected teeth had their roots included in self-cured acrylic resin. Blocks of microhybrid composite resin (Sinfony, 3M ESPE) were made according to the manufacturer´s instructions. Luting procedures with the self-adhesive resin cement (RelyX Unicem, 3M ESPE) were made in moist dentin with the composite resin disc kept with pressure of 0. 8 kg and it was light activated with halogen unit (3M ESPE) for a total of 80 seconds. Bonded specimens were stored in water at 37ºC for 24 hours.The restorations were included in self-cured acrylic resin and they were serially sectioned into sticks. Specimens (n=24) were submitted to microtensile bond strength on a universal testing machine EMIC DL – 2000 at crosshead speed of 0. 5mm/min. Results were evaluated according to Variance Analysis and Tukey test (α=0. 05). The highest bond strength mean was obtained with sound dentin (7. 58±2. 95 MPa). Discolored dentin obtained intermediate bond strength mean (6. 43±4. 46 MPa) without statistically significant differences. Caries-affected dentin showed the lowest bond strength mean (4. 21±3. 1 MPa) differing statistically from sound dentin. Failure mode were examinated with a scanning electron microscope. The predominant failure mode was mixed to the caries-affected dentin (85%) and discolored dentin (100%) whereas sound dentin was adhesive failure (54%). The results suggest that different dentin substrates can affect the bond strength of self- adhesive resin cement RelyX Unicem. / Este trabalho se propôs a avaliar a influência de diferentes substratos dentinários da resistência de união de um cimento resinoso autoadesivo. Foram pré-selecionados 50 molares humanos, sendo 25 contendo restaurações de amálgama e 25 contendo tecido cariado. Os dentes com tecido cariado foram desgastados em politriz com auxílio de lixa de carbeto de sílicio de granulação 100 até a remoção de tecido cariado, expondo uma dentina afetada por cárie. Os dentes contendo restaurações de amálgama seguiram o mesmo protocolo, até a remoção da restauração, expondo uma dentina com alteração de cor. Os dentes que não apresentaram dentina afetada por cárie ou dentina alterada pelo amálgama circundados por dentina hígida foram descartados. Foram realizadas tomadas radiográficas a fim de selecionar os dentes que apresentavam dentina remanescente de 2 a 3 mm. Os dentes selecionados tiveram suas raízes embutidas em resina acrílica autopolimerizável. Foram confeccionadas pastilhas de resina composta microhíbrida (Sinfony, 3M ESPE) conforme as orientações do fabricante. A cimentação com o cimento resinoso autoadesivo RelyX Unicem (3M ESPE) foi realizada em dentina úmida, mantida sob pressão de 0,8 kg e fotopolimerizada com luz halógena (3M ESPE) por um período total de 80 segundos. As amostras foram armazenadas por 24 horas em 100% de umidade a 37ºC. As restaurações foram incluídas com resina acrílica autopolimerizável e submetidas a cortes seriados, obtendo-se o formato de palitos. Os palitos foram examinados e divididos de acordo com o tipo de substrato dentinário que apresentavam: hígido, cariado e alterado por íons provenientes de amálgama. Os espécimes (n=24) foram submetidos ao teste de resistência de união à microtração na máquina de ensaios universal EMIC DL-2000 com velocidade de 0,5mm/minuto.Os resultados foram submetidos a Análise de Variância e ao teste de Tukey HSD. O substrato hígido apresentou o maior valor médio de resistência de união (7,58±2,95 MPa). O substrato alterado por íons metálicos apresentou um valor médio de resistência de união intermediário (6,43±4,46 MPa) não diferindo estatisticamento dos demais grupos avaliados. O substrato afetado por cárie apresentou o menor valor médio de resistência de união (4,21±3,1 MPa) diferindo estatisticamente do substrato hígido. O tipo de fratura foi analisado através de imagens obtidas em MEV e a falha do tipo mista foi predominante no substrato afetado por cárie (85%) e no substrato alterado por íons metálicos (100%) enquanto que no substrato hígido houve predominância de falha adesiva (54%). Os resultados sugerem que diferentes substratos dentinários podem afetar a resistência de união do cimento resinoso RelyX Unicem.
20

Efeito do tempo de polimeração na colagem de bráquetes com o uso dos fotoativadores LED e PAC

Dall'igna, Carine Maccarini January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:37Z (GMT). No. of bitstreams: 2 000397727-0.pdf: 6814018 bytes, checksum: 6e35a618cab019880f495b514a8897a3 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to evaluate and compare the bonding resistance to the shear bond strength of brackets bonded by two light curing units, LED and PAC, with different exposure times. Ninety deciduous incisor bovine teeth were divided into 6 groups, according to the curing light and exposure times used. In the LED group specimens were exposed to photoactivation for 5, 10 and 15 seconds. In the PAC group they were exposed to 3, 6 and 9 seconds of photoactivation. In order to check the LED (OrtholuxTM LED Curing Light, 3M Unitek, EUA) and PAC (Apollo® 95E, DenMed Technologies, EUA) light curing units, a specific radiometer for each unit was utilized, whose irradiance mean values were 830mW/cm2 and 1800mW/cm2, respectively. Brackets were bonded with TransbondTM XT®, and the enamel surfaces were prepared following the manufacturer’s instructions. After the brackets were bonded they were stored in distilled water at 37°C for 24 hours. They were then subjected to a shear force, in an inciso-gingival direction, at a crosshead speed of 0,5mm/min with a Emic DL2000® testing machine. According to ANOVA and Tukey tests, a significant difference in mean shear bond strength was detected among the study groups (p<0. 001).The LED photoactivated groups did not show statistical significant difference between them. The photoactivated group of 15s (16,68MPa) presented the highest range of bonding resistance, followed by the 10s group (14,76MPa), and than by the 5s group (13,92MPa). In regards to the PAC photoactivation, the 9s (12,66MPa) and 6s groups (9,96MPa) did not show statistical difference between them. The lowest range of shear bond strength was obtained by the PAC 3s group (8,29MPa), but when compared to the PAC 6s group, there was no statistical difference. It was observed that even though the groups that presented the lowest ranges of bonding resistance, LED 5s and PAC 3s, their values were still enough to support the strength applied by either orthodontic forces or forces of mastication.The Kruskal-Wallis analysis of the adhesive remmant index (ARI) scores indicated that there was no significant difference of bond failure sites between the study groups. The predominant ARI score was 3 (65,6%), which showed that the composite was kept adhered on the enamel, preventing it from trauma. The results conclude that either the LED or PAC technique can be used for bonding brackets effectively. The LED and PAC curing lights permit a significant reduction of time in the orthodontic bonding process compared to the traditional technique with halogen lamps. / O presente estudo objetivou avaliar e comparar a resistência de união ao cisalhamento de bráquetes colados com dois sistemas de fotoativação de resinas compostas, o LED e o PAC, mediante diferentes tempos de exposição. Foram selecionados 90 dentes incisivos decíduos bovinos, os quais foram divididos em seis grupos, de acordo com a fonte de luz e o tempo de exposição utilizado. No grupo LED, foram usados os tempos 5, 10 e 15 segundos e, no grupo PAC, 3, 6 e 9 segundos. Para aferir a potência da luz emitida pelos aparelhos LED (OrtholuxTM LED Curing Light, 3M Unitek, EUA) e PAC (Apollo® 95E, DenMed Technologies, EUA), foi utilizado um radiômetro para cada natureza de luz, os quais indicaram como valores médios 800mW/cm2 e 1800mW/cm2, respectivamente. O sistema adesivo utilizado para a colagem dos bráquetes foi o TransbondTM XT®, e as superfícies de esmalte foram preparadas conforme as recomendações do fabricante. Após a colagem, os corpos-de-prova foram mantidos em água destilada a 37°C por 24 horas e submetidos à tensão de cisalhamento na máquina de ensaio mecânico Emic DL2000®, no sentido inciso-cervical, à velocidade de 0,5mm/min. De acordo com as análises estatísticas ANOVA e Tukey, verificou-se que houve diferença significativa entre os grupos estudados (p<0,005).Os grupos fotoativados por LED não mostraram diferença estatisticamente significativa entre si, sendo que o grupo fotoativado por 15s (16,68MPa) apresentou a maior média de resistência de união, seguido pelo grupo fotoativado por 10s (14,76MPa) e por 5s (13,92MPa). Quanto aos fotopolimerizados por PAC, os grupos fotoativados por 9s (12,66MPa) e por 6s (9,96 MPa) não mostraram diferença estatisticamente significativa entre si. A menor média de resistência de união foi obtida com o grupo fotopolimerizado por PAC durante 3s (8,29MPa), embora este grupo não tenha se diferenciado estatisticamente do grupo fotoativado por PAC por 6s. Observou-se que, mesmo nos grupos que apresentaram as menores médias de resistência de união, LED 5s e PAC 3s, os valores são considerados suficientes para suportar as forças exercidas, tanto pela mecânica ortodôntica quanto pela mastigação. De acordo com o teste estatístico Kruskal-Wallis, não houve diferença significativa no padrão de falhas na descolagem entre os grupos estudados. O escore predominante foi o número 3 (65,6%) do índice de adesivo remanescente (IAR) mostrando que a resina composta, predominantemente, permaneceu aderida à superfície do esmalte, preservando-o de eventuais traumas. Estes resultados permitem concluir que, tanto a tecnologia LED quanto a tecnologia PAC podem ser utilizadas na colagem de bráquetes com efetividade, permitindo redução significativa no tempo da colagem ortodôntica, comparada à tecnologia tradicional por lâmpadas halógenas.

Page generated in 0.044 seconds