• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

RADIO FREQUENCY OVERVIEW OF THE HIGH EXPLOSIVE RADIO TELEMETRY PROJECT

Bracht, Roger, Dimsdle, Jeff, Rich, Dave, Smith, Frank 10 1900 (has links)
International Telemetering Conference Proceedings / October 26-29, 1998 / Town & Country Resort Hotel and Convention Center, San Diego, California / High explosive radio telemetry (HERT) is a project that is being developed jointly by Los Alamos National Laboratory and AlliedSignal FM&T. The ultimate goal is to develop a small, modular telemetry system capable of high-speed detection of explosive events, with an accuracy on the order of 10 nanoseconds. The reliable telemetry of this data, from a high-speed missile trajectory, is a very challenging opportunity. All captured data must be transmitted in less than 20 microseconds of time duration. This requires a high bits/Hertz microwave telemetry modulation code to insure transmission of the data within the limited time interval available.
2

Live Demonstration of Mismatch Compensation for Time-Interleaved ADCs

Nilsson, Johan, Rothin, Mikael January 2012 (has links)
The purpose of this thesis is to demonstrate the effects of mismatch errors that occur in time-interleaved analog-to-digital converters (TI-ADC) and how these are compensated for by proprietary methods from Signal Processing Devices Sweden AB. This will be demonstrated by two different implementations, both based on the combined digitizer/generator SDR14. These demonstrations shall be done in a way that is easy to grasp for people with limited knowledge in signal processing. The first implementation is an analog video demo where an analog video signal is sampled by such an TI-ADC in the SDR14, and then converted back to analog and displayed with the help of a TV tuner. The mismatch compensation can be turned on and off and the difference on the resulting video image is clearly visible. The second implementation is a digital communication demo based on W-CDMA, implemented on the FPGA of the SDR14. Four parallel W-CDMA signals of 5 MHz are sent and received by the SDR14. QPSK, 16-QAM, and 64-QAM modulated signals were successfully sent and the mismatch effects were clearly visible in the constellation diagrams. Techniques used are, for example: root-raised cosine pulse shaping, RF modulation, carrier recovery, and timing recovery.
3

Desenvolvimento de um tomógrafo de ressonância magnética: integração e otimização. / Development of a magnetic resonance tomograph: integration and improvement.

Martins, Mateus Jose 07 February 1995 (has links)
O presente trabalho descreve o desenvolvimento de um sistema de tomografia por Ressonância Magnética, para uso em diagnósticos médicos. Ele foi baseado em subsistemas disponíveis comercialmente, tais como os utilizados em equipamentos de imagens de RM comerciais. As principais contribuições deste projeto foram: o desenvolvimento de circuitos eletrônicos complementares e \"software\", necessários para tomar o \"hardware\" adquirido em um Tomógrafo de Ressonância Magnética para diagnósticos médicos. Isso não inclui somente o projeto de complexos programas necessários para gerar os pulsos de RF, formas de onda dos gradientes, sistema de aquisição de dados e as seqüências de pulsos necessárias para o completo sincronismo, mas também o desenvolvimento de uma interface amigável para realizar: a entrada de informações do paciente; a seleção das técnicas de imagem e o \"software\" interativo para visualização e seleção de planos. Um novo algoritmo de compressão de dados, para reduzir o armazenamento necessário de dados de imagens de RM, sem perda de informação foi também apresentado e implementado. Uma comparação com outras implementações de compressão de uso geral foi apresentada para mostrar uma performance superior na taxa de compressão e tempo de execução. / The present work describes the development of a Magnetic Resonance Tomography system to be used for medical diagnostics. It is based on commercially available subsystems such as used as in commercial MRI equipments. The main contributions to the project were: the development of fill up electronics and software needed to turn the acquired hardware into a MR Tomography for medical diagnostics. This includes not only the design of complex software needed to generate the used RF pulses, gradient waveforms, data acquisition system and the desired pulse sequences to synchronize all, but also the development of a user friendly interface to do: the entrance of patient\'s information; the selection of MR imaging techniques and interactive software for image viewing and planes selection. A new data compression algorithm to reduce the storage requirement of raw MR image data without information losses is also presented and implemented. A comparison with others general purpose compression implementations is presented to show the superior performance in the compression rate and execution time.
4

Desenvolvimento de um tomógrafo de ressonância magnética: integração e otimização. / Development of a magnetic resonance tomograph: integration and improvement.

Mateus Jose Martins 07 February 1995 (has links)
O presente trabalho descreve o desenvolvimento de um sistema de tomografia por Ressonância Magnética, para uso em diagnósticos médicos. Ele foi baseado em subsistemas disponíveis comercialmente, tais como os utilizados em equipamentos de imagens de RM comerciais. As principais contribuições deste projeto foram: o desenvolvimento de circuitos eletrônicos complementares e \"software\", necessários para tomar o \"hardware\" adquirido em um Tomógrafo de Ressonância Magnética para diagnósticos médicos. Isso não inclui somente o projeto de complexos programas necessários para gerar os pulsos de RF, formas de onda dos gradientes, sistema de aquisição de dados e as seqüências de pulsos necessárias para o completo sincronismo, mas também o desenvolvimento de uma interface amigável para realizar: a entrada de informações do paciente; a seleção das técnicas de imagem e o \"software\" interativo para visualização e seleção de planos. Um novo algoritmo de compressão de dados, para reduzir o armazenamento necessário de dados de imagens de RM, sem perda de informação foi também apresentado e implementado. Uma comparação com outras implementações de compressão de uso geral foi apresentada para mostrar uma performance superior na taxa de compressão e tempo de execução. / The present work describes the development of a Magnetic Resonance Tomography system to be used for medical diagnostics. It is based on commercially available subsystems such as used as in commercial MRI equipments. The main contributions to the project were: the development of fill up electronics and software needed to turn the acquired hardware into a MR Tomography for medical diagnostics. This includes not only the design of complex software needed to generate the used RF pulses, gradient waveforms, data acquisition system and the desired pulse sequences to synchronize all, but also the development of a user friendly interface to do: the entrance of patient\'s information; the selection of MR imaging techniques and interactive software for image viewing and planes selection. A new data compression algorithm to reduce the storage requirement of raw MR image data without information losses is also presented and implemented. A comparison with others general purpose compression implementations is presented to show the superior performance in the compression rate and execution time.

Page generated in 0.0845 seconds