• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • Tagged with
  • 337
  • 337
  • 145
  • 87
  • 71
  • 56
  • 55
  • 52
  • 42
  • 40
  • 40
  • 39
  • 39
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Controle de qualidade e dose de entrada na pele em serviços de mamografia de Minas Gerais

Maurício de Oliveira 28 August 2006 (has links)
Nenhuma / Em exames que fazem uso da radiação ionizante, a dose a que o paciente é exposto deve ser mantida tão baixa quanto possível, de acordo com os princípios da proteção radiológica, porém sem comprometer a qualidade da imagem, que vai possibilitar o seu uso como ferramenta útil para o diagnóstico. A obtenção de imagens com definição e contraste satisfatórios pode ser alcançada com uma adequação do feixe de radiação e também com a escolha correta do sistema receptor e do seu processamento adequado. A mama é composta por estruturas com densidades muito próximas o que aumenta a dificuldade na obtenção de contraste desejado na imagem formada pelos raios X. Esse fator associado à qualidade da radiação, à compressão da mama, ao uso de grade, ao sistema filme-écran, e ao processamento dos filmes são fatores que influenciam no contraste da imagem mamográfica. Neste trabalho, a proposta foi levantar a situação dos serviços de mamografia do estado de Minas Gerais, através de uma amostra desses serviços e estabelecer procedimentos de garantia de qualidade e controle de risco, sob o ponto de vista de proteção radiológica e qualidade dos exames. Para realização do estudo foram coletados dados e realizados testes em 122 (cento e vinte e dois) serviços. Nestes serviços foram avaliados 134 (cento e trinta e quatro) mamógrafos convencionais, entre novembro de 2003 e dezembro de 2005, o que corresponde a aproximadamente 40% do total esperado de 330 equipamentos instalados e em uso no Estado de Minas Gerais. O trabalho foi conduzido enfocando o desempenho dos mamógrafos e processadoras, a qualidade da imagem, utilizando um simulador radiográfico que contém objetos que simulam estruturas da mama, e também um cartão dosimétrico com dosímetros termoluminescentes de Fluoreto de Lítio (TLD LiF-100) para medir a dose de entrada na superfície do simulador. Os resultados mostram que em 73 (54,5%) equipamentos não se obteve a pontuação mínima desejada para a qualidade da imagem. Dentre os resultados destaca-se o desempenho insatisfatório em 83 serviços (67%), no que ser refere ao sistema de processamento, tendo sido constatada significativa influência na qualidade final da imagem relacionado a este item. Na distribuição dos valores de kerma de entrada na superfície do simulador foram encontrados valores entre 2,41 a 16,05 mGy, com média de 7,8 mGy. Somente 17 serviços excederam o nível de referência adotado no país, de 10 mGy. Pode-se concluir que embora os níveis de radiação a que as pacientes estão expostas são aceitáveis na maioria dos serviços de mamografia, esforços devem ser feitos para garantir a qualidade da imagem. / In medical exposures, the radiological protection principles establish that doses provided to patients should be maintained as low as possible, but without reducing the quality of the image that is to be used as the main tool for diagnostic purpose. Images with definition and satisfactory contrast can be obtained under adequate geometry of the radiation beam and also with the correct choice of the receiving system and adequate processing. The breast is made of low density tissues that are formed by structures with very close densities; this increases the difficulty to get the contrast that is wanted for the image produced by the x-ray. Other factors that can influence the contrast of the mammographic image are the quality of the radiation, compression of the breast, use of gratings, film-ecran system, and the film processing. This work intended to get an overview of the mammographic services in the Minas Gerais state concerned the image quality and radiation protection, which was based on a representative sample of services. Data were collected and checks were performed in 122 services, where 134 mammography units were evaluated from November 2003 to December 2005. This amount corresponds to 40% of the total number of mammography units that are installed and used in Minas Gerais. A PMMA phantom with objects to simulate breast structures and LiF-100 thermoluminescent detectors to measure the entrance surface kerma were used to evaluate both the performance of the mammography and the processing units and the image quality. The results showed that 73 (54.5%) mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 83 (67%) services showed inadequate performance in their processing systems, which had significant influence on the image quality. Concerning the kerma values on the phantom entrance surface, they varied from 2.41 to 16.05 mGy with a mean value of 7.8 mGy; only 17 services exceeded the nationally adopted diagnostic reference level of 10 mGy. One may concluded that although the radiation levels given to the patient are acceptable in most mammographic services, efforts should be done to improve the quality of the provided image.
192

Implantação do novo protocolo de dosimetria da AIEA no LCI/IPEN/CNEN / Implementation of the new IAEA code of practice at LCI/IPEN/CNEN

Patricia Mára de Siqueira 22 August 2006 (has links)
A fim de implementar o novo código de prática da Agência Internacional de Energia Atômica (AIEA) no Brasil, o Laboratório de Calibração de Instrumentos (LCI/IPEN) está realizando calibrações em termos de kerma no ar e em termos de dose absorvida na água, em feixes de 60Co. As razões ND,w/NK obtidas são comparadas com valores da literatura, obtendo-se concordância satisfatória. As diferenças entre os valores das razões CK (ND,w/NK) obtidas no presente trabalho e os valores da literatura são devidas a vários fatores. Estes fatores podem ser as variações entre as câmaras, que devem ser objeto de diferenças nas incertezas estimadas pelos PSDLs, e as diferenças nos padrões utilizados por cada Instituto de Metrologia Nacional (NMI) ou Laboratório de Dosimetria. No entanto, se forem conhecidas as razões entre cada NMI e o BIPM, para os padrões de kerma no ar e de dose absorvida na água, é possível a normalização das razões CK medidas para as razões equivalentes ao BIPM. Todos os resultados de razões CK obtidos foram convertidos para as razões equivalentes ao BIPM para facilitar a comparação. Neste trabalho é discutida a utilização da razão CK como parâmetro de controle de qualidade na verificação de resultados das calibrações rotineiras. Para avaliação dos procedimentos de calibração adotados no LCI, foram realizados testes de estabilidade a longo prazo com as câmaras de ionização padrões. Além disso, foi criado um banco de dados para armazenamento dos dados de calibração, com o objetivo de melhorar a qualidade do procedimento de calibração. / In order to implement the new IAEA code of practice in Brazil the national calibration laboratories, the Laboratory of Instrument Calibration (LCI/IPEN) is calibrating clinical dosimeters in terms of both air kerma and absorbed dose to water in a 60Co gamma ray beam. The ND,w/NK ratios thus obtained are then compared with the literature values; a satisfactory agreement has been found. The differences between the CK values obtained in the present work and the literature values may be due to several components. These could be the chamber-to-chamber variations which may be subject to different estimated uncertainties by PSDLs, and the variations in the standards used by each National Metrology Institute (NMI) or Dosimetry Laboratory. However, since the ratio of both air kerma and absorbed dose to water standards for each NMI to those of the BIPM are known, it is possible to reduce the measured ratios to the expected BIPM equivalent ratios. All these CK results have been converted to the BIPM equivalent values to facilitate comparison. The use of the CK value as a and quality control parameter to verify the results of the routine calibrations is discussed in this work. The long term stability of wich standard ionization chamber was checked in order to evaluate the calibration procedures followed at LCI. Moreover, a database was created to store the calibration data aiming the quality improvement of the calibration procedure.
193

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Thyago Fressatti Mangueira 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
194

Quantificacao de imagens tomograficas para calculo de dose em diagnose e terapia em medicina nuclear / Quantification of tomography images for dose calculation for diagnosis and therapy in nuclear medicine

MASSICANO, FELIPE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:15Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
195

Determinacao de fatores de conversao de dose para radiacao gama externa em residencias

MADUAR, MARCELO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:02Z (GMT). No. of bitstreams: 1 06870.pdf: 3530366 bytes, checksum: 5bddd2a5ab0508e81a57fdbb2c5f73d1 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
196

Intercomparacao de colimadores de multiplas laminas para implementacao de terapia de feixes de intensidade modulada

VITERI, JUAN F.D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:37Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
197

Avaliacao dos criterios de qualidade de imagem e estudo das doses em um departamento de mamografia / Evaluation of the image quality criteria and study of doses in a mammography department

ALCANTARA, MARCELA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:46Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
198

Contribuicao para avaliacao critica da radioprotecao por meio da analise retrospectiva das doses associadas ao trabalho com fontes nao seladas de iodo-131

CARNEIRO, JANETE C.G.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:21Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:04Z (GMT). No. of bitstreams: 1 06428.pdf: 6304808 bytes, checksum: 564076d766d1209b8ce5d2f96ff4876b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
199

Pesquisa, desenvolvimento e caracterizacao de materiais dosimetricos para monitoramento em processos de irradiacao com doses altas

GALANTE, ANA M.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:54Z (GMT). No. of bitstreams: 1 09602.pdf: 7986999 bytes, checksum: 3925b141ff3cb5747e1bfa4d230c6dbf (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:99/06641-9
200

Estudo das propriedades do açucar líquido invertido processado com radiação gama e feixe de elétrons / Study of the properties of inverted liquid sugar processed with gamma radiation and electron beam

PODADERA, PRISCILLA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:13Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.091 seconds