Inventario de radionuclideos artificiais em agua do mar e sedimentos da costa sul do Brasil

FIGUEIRA, RUBENS C.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:12Z (GMT). No. of bitstreams: 1 06901.pdf: 9310315 bytes, checksum: 34ec97737bf373b58a295f330b6aa935 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
62

Měření osobních dávek pacientů v radioterapii mimo centrální svazek ionizujícího záření pomocí elektronického osobního dozimetru / Measurement of patients´ personal doses in radiotherapy outside the central beam of ionizing radiation using the electronic personal dosimeter

CHYLÍKOVÁ, Renáta January 2013 (has links)
The introductory part of the diploma thesis primarily focuses on the history of radiotherapy, i.e. what it emerged from and how it developed, as it is one of the most important fields in medicine, especially because thousands of people are irradiated every day due to different tumour and non-tumour diseases. Another reason why ionizing radiation is described is the fact that it is a necessary part of tumour disease irradiation. Ionizing radiation is also connected with radiation protection. This section presents a historical overview of radiation protection, as well as principles and quantities of this field. Furthermore, it focuses on Czech acts, decrees, and government regulations which define various measures governing this issue. Radiation protection forms the basis of patient, workplace, and personnel monitoring. All this is connected with the measurement and evaluation of received personal doses. This brings the thesis to the field of dosimetry, therefore various dosimeters used in practice are described. The aim of this diploma thesis is the measurement of patients? personal doses in head and neck irradiation using the electronic personal dosimeter at the radiotherapy centre of Nemocnice České Budějovice, a. s. The thesis is based on the question of whether irradiation doses that patients with head and neck tumours receive outside the primary radiation beam are negligible. The theoretical part of the thesis uses all available resources from both foreign and Czech literature. The practical part is based on numerical statistics, i.e. a quantitative method. The research was carried out at the radiotherapy centre of Nemocnice České Budějovice, a. s. Irradiation of patients with head and neck tumours was performed on a linear accelerator. Each patient had a mask to which an electronic personal dosimeter was attached during irradiation. Using this dosimeter, it was possible to measure doses received outside the central radiation beam. The measured values were then used to carry out assessment using formulas. Patients who undergo cancer treatment receive relatively high doses of radiation, so my main goal was to measure personal dose equivalents at the reference point. When comparing the percentage of the number of examinations with the web portal Epidemiology of Malignant Tumours in the Czech Republic, it was found that irradiation of the neck is more frequent than irradiation of the head. The total values of personal dose equivalents are relatively high in each patient, but because it is medical treatment, these values are not subject to radiation exposure limits. The comparison of the irradiated areas shows that irradiation of the neck has small values of personal dose equivalents to 1Gy compared to irradiation of the head.
63

Câmara de ionização aplicada a medidas de altas taxas de dose

RODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
64

Determinação da taxa de desintegração e das probabilidades de emissão ga por decaimento do I-123 / Desintegration rate and gamma ray emission probability per decay measurement of sup(123)I

GISHITOMI, KAROLINE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:42Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
65

Avaliação da variação da radioatividade natural em areias da Praia de Camburi-Vitória-Espírito Santo com fatores climatológicos e geológicos da região / Assessment of the variation of natural radioactivity in sands of Camburi beach-Vitória-Espírito Santo with climatological and geological factors of the region

BARROS, LIVIA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:03Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
66

Monitoração de Rn-222 nos galpões de armazenamento de rejeitos radioativos do IPEN / 222Rn monitoring in the radioactive storage IPEN

MANOCCHI, FABIO H. 19 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-19T10:17:33Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-19T10:17:33Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
67

Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em medicina nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine

TIEZZI, RODRIGO 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T11:16:05Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T11:16:05Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
68

Inventario de radionuclideos artificiais em agua do mar e sedimentos da costa sul do Brasil

FIGUEIRA, RUBENS C.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:12Z (GMT). No. of bitstreams: 1 06901.pdf: 9310315 bytes, checksum: 34ec97737bf373b58a295f330b6aa935 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
69

Avaliação da exposição ao sup(222)Rn nas cavernas do Parque Estadual Turístico do Alto Ribeira (PETAR)

ALBERIGI, SIMONE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:00Z (GMT). No. of bitstreams: 0 / No presente trabalho foram determinadas as concentrações de radônio em seis cavernas do Parque Estadual Turístico do Alto Ribeira (PETAR) e foi estimada a dose efetiva anual recebida pelos guias turísticos da região. O PETAR apresenta quatro núcleos de visitação: Santana, Ouro Grosso, Caboclos e Casa de Pedra e recebe anualmente cerca de 40 mil visitantes. As cavernas escolhidas foram Couto, Água Suja, Laje Branca, Morro Preto e Santana, do núcleo Santana e a caverna Alambari de Baixo do núcleo Ouro Grosso, por receberem o maior número de turistas. Os níveis de radônio foram determinados utilizando detectores de traços nucleares do estado sólido Makrofol E expostos trimestralmente por um período de 26 meses, entre Outubro de 2003 e Novembro de 2005. As concentrações de 222Rn variaram na faixa de 153 Bq.m-3 a 6607 Bq.m-3, sendo observado que, de uma maneira geral, os níveis de radônio diminuem nos períodos frios. A dose efetiva anual, considerando os cenários mais realistas, com média geométrica das concentrações, fator de equilíbrio 0,5 e tempo de exposição anual para cada caverna, variou entre 0,2 mSv.a-1 para a caverna Couto, bastante ventilada e 4,0 mSv.a-1 para a caverna Santana, a mais visitada, com galerias sem comunicação externa. Para o pior cenário, com média aritmética das concentrações, fator de equilíbrio 1 e tempo de exposição anual para todas as cavernas, a dose efetiva anual total foi 16,1 mSv.a-1. Todas as estimativas da dose efetiva anual estão abaixo de 20 mSv.a-1, sugerido como o valor limite para dose efetiva anual para exposição ocupacional pela Comissão Internacional de Proteção Radiológica (ICRP 60, 1990). / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
70

Câmara de ionização aplicada a medidas de altas taxas de dose

RODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Irradiadores comerciais de grande porte são projetados para processarem grandes quantidades de produtos com altas doses, por exposição à radiação gama. A irradiação em escala industrial é efetuada de forma dinâmica, em que os produtos percorrem um caminho em torno de uma fonte de radiação, geralmente de 60Co, cuja atividade é da ordem de TBq a PBq (kCi a MCi). A dose será diretamente proporcional ao tempo transcorrido pelo material para percorrer este trajeto em torno da fonte. Entretanto, em algumas situações, principalmente para pesquisas ou processos de validação de clientes seguindo a norma ISO 11137, se faz necessário irradiar pequenas amostras com doses fracionadas na posição de irradiação estática. Nesta posição as amostras são colocadas dentro da sala de irradiação a uma distância fixa da fonte e as doses recebidas são determinadas utilizando-se dosímetros. Portanto, a dose somente será conhecida depois da irradiação, pela leitura dos mesmos. Entretanto, em irradiadores industriais, diferentes tipos de produtos com diferentes densidades atravessam o caminho entre a fonte e a posição de irradiação estática, onde estão as amostras. Conseqüentemente, a taxa de dose variará dependendo da densidade do produto, que está sendo irradiado dinamicamente. Uma metodologia adequada seria monitorar a dose recebida pelas amostras em tempo real, medindo a dose por meio de um detector de radiação, com uma melhor precisão e exatidão. Neste trabalho foi desenvolvida uma câmara de ionização cilíndrica de 0.9 cm3, para monitorar as altas doses recebidas por amostras em tempo real, na posição de irradiação estática de um irradiador gama de 60Co. Os gases de nitrogênio e de argônio a pressão de 10exp5 Pa (1 bar) foram utilizados para preencherem a câmara de ionização e determinar uma configuração de trabalho apropriada, para o detector ser utilizado em medidas de altas doses. Cabos de isolação mineral foram soldados diretamente ao corpo da câmara de ionização, para a transmissão do sinal gerado pelo detector até a eletrônica associada, distante cerca de 20 m. O sinal obtido foi cerca de 100 vezes maior do que o ruído de fundo. Este sistema dosimétrico foi testado em um irradiador gama de categoria I e na posição de irradiação estática de um irradiador de grande porte, em que diferentes taxas de dose foram obtidas utilizando materiais absorvedores. Foi encontrada uma boa linearidade do detector entre a dose e a carga, independentemente das diferentes taxas de dose. As incertezas de todas as curvas ficaram abaixo dos +/- 5 %, valor de incerteza máxima recomendada para um sistema dosimétrico de rotina. A câmara de ionização desenvolvida se mostrou adequada para ser utilizada como um dosímetro em tempo real, independente da degradação do espectro causada pela absorção dos fótons da fonte de 60Co, pelo material em irradiação dinâmica. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP