• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analyse expérimentale et simulation de la ventilation naturelle mono-façade pour le rafraîchissement des immeubles de bureaux

Caciolo, Marcello 17 December 2010 (has links) (PDF)
L'application de la ventilation naturelle peut contribuer sensiblement à la réduction des besoins de climatisation et à l'amélioration du confort d'été dans les immeubles de bureaux. Dans cette thèse, une configuration simple de ventilation naturelle, c'est-à-dire la ventilation mono-façade, est étudiée expérimentalement et par simulation. Après avoir examiné les phénomènes qui contribuent au renouvellement de l'air, on évalue la validité et l'applicabilité des modèles existants afin de calculer le débit de ventilation, en comparant leurs résultats avec ceux d'une campagne de mesures effectuée dans une pièce expérimentale. Ensuite, on valide l'utilisation de la CFD, avec trois modèles différents de turbulence, pour la simulation de la ventilation naturelle mono-façade, par comparaison avec les essais. Les résultats d'un des modèles de turbulence (RANS RSM) sont utilisés pour l'établissement d'une nouvelle corrélation pour le calcul du débit de ventilation. Celle-ci apporte des améliorations par rapport aux corrélations existantes, en particulier lorsque l'ouverture est située sous le vent. Cette nouvelle corrélation est couplée à un modèle thermique dynamique afin d'évaluer le potentiel de rafraîchissement de la ventilation naturelle mono-façade dans des immeubles de bureaux neufs. En particulier, on étudie la réduction des besoins de climatisation dans des immeubles climatisés et le nombre d'heures d'inconfort en l'absence de climatisation. L'influence de plusieurs paramètres est considérée : climat, orientation, inertie, taux de surface vitrée, apports internes et stratégie de ventilation (diurne, nocturne et diurne + nocturne). Les simulations montrent des réductions importantes des besoins de refroidissement, entre 30 et 90%. Il est possible de se passer de climatisation, sans générer d'inconfort, à condition de privilégier une inertie lourde et de maitriser les apports internes et solaires.
2

Contribution à l'étude d'un échangeur de chaleur air-sol (puits canadien) pour le rafraîchissement de l'air sous le climat chaud et semi-aride de Marrakech / Contribution to the study of an earth to air heat exchanger for air cooling in hot and semi-arid climate of Marrakech

Khabbaz, Mohamed 17 December 2016 (has links)
La conception des bâtiments à faible consommation d'énergie est devenue un enjeu très important à travers le monde afin de minimiser la consommation d'énergie et les émissions de gaz à effet de serre associés. Au Maroc, le secteur du bâtiment représente 25% de la consommation énergétique finale du pays avec 18% réservée au résidentiel et 7% pour le tertiaire (ADEREE 2011). L'intégration de systèmes passifs ou semi-passifs de rafraîchissement/chauffage dans le bâtiment est désormais indispensable pour la réduction de la consommation énergétique tout en améliorant le confort thermique. Un de ces systèmes est l’échangeur air-sol (EAHX). Le principe du rafraîchissement à l'aide de l’échangeur air-sol est bien établi, mais le comportement d'un tel système dépend des conditions climatiques et de la nature du sol. L’échangeur air-sol étudié est installé dans une maison type villa située dans la banlieue de Marrakech. Un monitoring de ce système a été réalisé durant l’été 2013 à travers un suivi des températures et de l'humidité durant 39 jours. Les résultats montrent que l’échangeur air-sol est un système adapté pour le rafraîchissement de l’air dans les bâtiments à Marrakech, puisqu’il procure une température de soufflage quasi-constante d’environ 22°C pour le débit 244 m3/h et 25°C pour le débit de 312m3/h, avec une humidité relative autour de 50 % alors que la température extérieure dépasse 40°C. Le modèle mathématique choisi et l’outil de simulation associé, Type 460 opérant sous le logiciel commercial TRNSYS, sont analysés et validés par confrontation avec les résultats expérimentaux. Cette confrontation a montré une excellente concordance, avec un écart absolu moyen entre la mesure et la simulation toujours inférieur à 0,5°C et décroit à 0,2°C à la sortie de tube enterré. La validation de l’outil de simulation avec un échangeur air-sol enterré dans un sol soumis à conditions météorologiques extérieures n’a pas été réalisée auparavant. D'autre part, les simulations dynamiques de l’échangeur air-sol sont réalisées en fonctionnement continu, avec 1 et 3 tubes durant la période chaude de l’année (mai-septembre). Les résultats montrent que le système procure une température à la sortie de tube enterré de 25,1°C (1 tube) et 26 °C (3 tubes). Il en résulte une capacité de refroidissement de 58w/m2 (1 tube) et 55w/m2 (3 tubes) pour une température à l’entrée de 44,6°C. Une étude de sensibilité, utilisant la méthode de Sobol, de la performance thermique de l'échangeur durant la saison chaude (mai-septembre) a permis de dégager les paramètres les plus influents. Par la suite, une étude paramétrique complète sur l’énergie sensible totale perdue par l’air lors dans son passage dans l’échangeur air-sol est réalisée en fonction des paramètres les plus influents déterminés auparavant. / The low energy buildings tendency has become a major worldwide key to minimize energy consumption and greenhouse gas emissions issues. In Morocco, the building sector represents 25% of the total final energy consumption, whereas 18% is dedicated for residential and 7% for the tertiary sector (ADEREE 2011). The integration of passive or semi-passive for cooling/heating purposes into buildings is an essential act for reducing energy consumption while improving thermal comfort. One of these systems is the Earth to Air Heat Exchanger (EAHX). Its principle to use the ground-coupled heat exchanger for cooling is well established, but the behavior of such a system depends on the climate and the soil, which influences the choice of design parameters of this system. We performed a numerical and experimental study on the thermal performance of an Earth to air heat exchanger installed in a villa type house in the suburbs of Marrakech. A monitoring survey was conducted during the summer period of 2013, to acquire temperature and humidity measurements for 39 days. The results show that the earth to air heat exchanger is a system more adapted to refresh the air in buildings in Marrakech, as it provides a quasi constant air temperature of approximately 22°C for flow 244 m3/h and 25°C for flow of 312 m3/h, with relative humidity that is around 50% when the outside temperature exceeds 40°C. The mathematical model chosen and the associated simulation tool used is Type 460 operating under the TRNSYS commercial software, analyzed and validated by comparison with experimental results. This comparison showed excellent agreement, with an average absolute difference between the measurement and simulation that is always lower than 0.5°C and 0.2°C as it decreases at the output of the buried pipe. On the other hand, dynamic simulations of the EAHX using TRNSYS software (TYPE 460) were performed with one pipe or three pipes continuously running. The achieving specific cooling capacity is 58 W/m2 (one pipe) and 55 W/m2 (three pipes) obtained for air temperatures of 25 °C and 26 °C respectively, at the EAHX outlet and 44.6 °C at its inlet. A sensitivity analysis, using the method of Sobol, of the thermal performance of the earth air heat exchanger (EAHX) in the hot season (May-September) has identified the most influential parameters. Thereafter, a complete parametric study on the total sensible energy lost through the air when in passing through the air-ground heat exchanger is made based on the most influential parameters determined previously.
3

Contribution à l'étude numérique de la ventilation naturelle dans des cavités ouvertes par la simulation des grandes échelles. Application au rafraîchissement passif des bâtiments

Brangeon, Boris 26 October 2012 (has links) (PDF)
Contexte du sujet : La climatisation est un poste de dépense énergétique important dans le secteur du bâtiment, qui pourrait être réduit de manière drastique par l'utilisation de systèmes passifs de rafraîchissement. Dans les climats chauds et humides, le rafraîchissement passif des bâtiments est une solution éprouvée, qui s'ordonne autour de quatre principes : minimiser les apports de chaleur interne et externe, apporter de l'inertie au bâtiment, humidifier l'air et assurer une bonne ventilation pour favoriser les échanges convectifs. Objectifs : La description des transferts thermo-convectifs (évaluation des débits massiques, des transferts de chaleur) mis en jeu dans des cavités ouvertes (pièces avec ventilation traversante, cheminées solaires, doubles peaux, espaces sous-toiture) est encore mal connue et constitue un enjeu pour l'amélioration des systèmes passifs. L'étude de ces phénomènes peut être évaluée par la mécanique des fluides numérique. Les objectifs de ce travail de thèse sont : de réaliser des simulations numériques fines du comportement thermo-aéraulique dans des configurations typiques de systèmes passifs en climat tropical humide, afin d'améliorer nos connaissances sur la ventilation naturelle, d'approfondir et d'apporter des éléments de réponses en ce qui concerne le choix des conditions limites numériques à appliquer pour les systèmes ouverts. Modélisation numérique : L'approche numérique adoptée dans ce travail, pour étudier la convection naturelle turbulente, est la simulation des grandes échelles (SGE ou LES en anglais). Cette approche se situe à mi-parcours entre la méthode de calcul direct et la réso- lution des équations moyennées en temps, de type RANS. L'avantage d'une telle technique est la réduction appréciable du nombre de points de discrétisation nécessaire par rapport à ce- lui exigé par la méthode de calcul direct, tout en conservant l'aspect dynamique des écoulements. Résultats : Les résultats obtenus lors de ce travail concernent l'étude des conditions limites dynamiques à imposer pour des géométries ouvertes avec une SND et l'application de la SGE à différentes configurations de cavités ouvertes en régime turbulent, afin de caractériser les champs de température et de vitesse et d'en déduire les grandeurs intégrales d'intérêt (débit massique, débit enthalpique, renouvellement d'air, ...). Les résultats de ces calculs ont été comparés soit à d'autres résultats numériques dans le cadre de benchmarks nationaux (benchmark numérique AmeTh et ADNBâti) ou à des résultats expérimentaux.

Page generated in 0.0794 seconds