• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • Tagged with
  • 8
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnostic methods in helicobacter pylori infection : development, evaluation and application /

Jansson Rehnberg, Ann-Sofie, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2006. / Härtill 5 uppsatser.
2

Punctal occlusion impact on tear film immuno-regulatory proteins measured by cytometric bead-based assay

LaFrance, Martin W. January 2008 (has links) (PDF)
Thesis (Ph. D.)--University of Alabama at Birmingham, 2008. / Title from first page of PDF file (viewed Sept. 16, 2008). Includes bibliographical references (p. 208-224).
3

Rapid assessment of drug susceptibility and mutation to resistance in mycobacterium tuberculosis Beijing type /

Werngren, Jim, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2006. / Härtill 5 uppsatser.
4

Análise de diferentes métodos de sequenciamento de larga escala dos genes envolvidos no hipopituitarismo e embriogênese hipofisária / Analysis of different methods of high-throughput sequencing of genes involved in hypopituitarism and pituitary embryogenesis

Benedetti, Anna Flavia Figueredo 18 April 2019 (has links)
Mutações nos genes envolvidos na embriogênese hipofisária já foram descritas relacionadas a quadros isolados de deficiência hormonal múltipla e/ou associado a fenótipos extra-pituitários. As mutações encontradas em humanos foram descritas em genes envolvidos na embriogênese hipofisária e cujos fenótipos foram gerados em animais a partir de nocaute, servindo de ponto de partida para sua busca em pacientes com fenótipo similar. Essa estratégia é conhecida como busca por gene candidato, e é feita pela técnica de sequenciamento tradicional Sanger. Na última década, com o avanço de novas tecnologias de sequenciamento, diversos genes foram associados ao hipopituitarismo, principalmente utilizando-se a metodologia de exoma. Contudo, ainda há uma grande parcela dessa população sem diagnóstico molecular, como evidenciado em um levantamento na literatura por Fang e colaboradores e cuja tendência foi observada no ambulatório de Endocrinologia do Desenvolvimento do Hospital das Clínicas, onde apenas 14% dos pacientes tiveram o seu diagnóstico molecular determinado. Com isso, as tecnologias de sequenciamento de última geração, passaram a ser uma ferramenta promissora para determinação molecular dos fenótipos dos pacientes. Logo, alguns pacientes em seguimento no ambulatório de endocrinologia do desenvolvimento tiveram o exoma sequenciado, e uma análise das métricas do sequenciamento evidenciou regiões de cobertura muito baixa, o que não permitiu a conclusão sobre a presença ou ausência de variantes nessas regiões. Entre essas regiões estão os genes SOX2 e SOX3, os quais possuem variantes conhecidas causadoras do fenótipo. Esse trabalho tem como objetivo analisar a cobertura dos genes envolvidos na embriogênese hipofisária assim como os relacionados ao hipopituitarismo congênito em quatro diferentes kits de preparação de biblioteca para exoma, a fim de identificar a melhor metodologia para um diagnóstico molecular dos pacientes alem determinar variantes especificas da população brasileira na região de interesse através de busca no site ABraOM. Foram analisados 76 genes em um total de 119 amostras separadas em três grupos, sendo o primeiro grupo de amostras HapMap, o segundo de um paciente com hipopituitarismo e sua mãe e o terceiro de amostras brasileiras aleatórias. Os kits utilizados foram NimbleGen (Roche), Nextera (Illumina), SureSelect e SureSelect+UTR (Agilent). Para isso, foram utilizados diversos programas de bioinformática, tendo entre eles o FASTQC, BWA, GATK, Annovar, Qualimap e bedTools. Análises da qualidade do sequenciamento, assim como a taxa de mapeamento e duplicação mostraram que as amostras utilizadas apresentavam qualidades adequadas e similares entre si para a análise. De acordo com os resultados obtidos em relação a cobertura, o kit da NimbleGen apresenta uma queda em sua cobertura dos genes de interesse em relação a sua capacidade de cobertura do exoma global, algo que pode ser devido à alta taxa de GC na região de interesse, uma vez que a capacidade do kit nessas regiões é deficiente em relação aos demais. Os genes com piores coberturas em todas as quatro tecnologias foram os genes HES5, que apesar de fazer parte da embriologia hipofisária, não possui variante relacionada ao fenótipo em humanos, e o SOX3 que, apesar de ter muita baixa cobertura na NimbleGen, é bem coberto na SureSelect. Isso corrobora com a análise de capacidade de cobertura em regiões com alta taxa de GC. Somado a isso observou-se que a população brasileira tem 885 variantes únicas e exclusivas. Concluímos, portanto, que o kit SureSelect, da Agilent, tem o melhor desempenho na região de interesse, assim como no exoma global, sendo o indicado para estudos em coortes de hipopituitarismo e a população brasileira possui variantes únicas inerentes a ela / Mutations in the genes involved in pituitary embryogenesis have been described related to isolated cases of multiple hormonal deficiency and/or associated with extra-pituitary phenotypes. Mutations found in humans were described in genes involved in pituitary embryogenesis by generating phenotypes knockout animals, serving as the starting point for their search in patients with similar phenotype. This strategy is known as gene candidate search and is performed by the traditional Sanger sequencing technique. In the last decade, with the advancement of new sequencing technologies, several genes have been associated with hypopituitarism, mainly using the exome methodology. However, there is still a large portion of this population without molecular diagnosis, as evidenced by a survey in the literature by Fang et al., This trend was also observed in the outpatient clinic of Developmental Endocrinology of Hospital das Clínicas, where only 14% of the patients had their molecular diagnosis. With this, high throughput sequencing technologies have become a promising tool for the molecular determination of patients\' phenotypes. Therefore, we sequenced the exome of some of our patients, and an analysis of the sequencing quality showed very low coverage regions, which harms the researcher\'s ability to reach a conclusion regarding presence or lack of variants in these regions. Among these regions are the SOX2 and SOX3 genes, which have many variants that are known to cause the phenotype. This work aims to analyze the coverage of the genes involved in pituitary embryogenesis as well as those related to congenital hypopituitarism in four different exome library preparation kits in order to identify the best methodology for a molecular diagnosis of the patients and to determine specific variants of the Brazilian population in the region of interest by searching the ABraOM website. A total of 76 genes were analyzed in a total of 119 samples in three groups: the first group of HapMap samples, the second of a patient with hypopituitarism and his mother, and the third group of random Brazilian samples. The kits used were NimbleGen (Roche), Nextera (Illumina), SureSelect and SureSelect + UTR (Agilent). For this, several bioinformatics programs were used, among them FASTQC, BWA, GATK, Annovar, Qualimap and bedTools. Sequencing quality analysis, as well as the mapping and duplication rate, showed that the samples used presented adequate and similar qualities for the comparison. According to the results obtained in relation to the coverage, the NimbleGen kit shows a drop in its coverage of the genes of interest in relation to its capacity to cover the global exome, something that may be due to the high GC rate in the region of interest, once the capacity of the kit in these regions is not as good as the others. The genes with the worst coverage in all four technologies were the HES5 gene, which despite being part of the pituitary embryology, have no phenotype-related variant in humans, and SOX3 which, despite having very low coverage in NimbleGen, is well covered on SureSelect. This corroborates the analysis of coverage capacity in regions with a high GC rate. In addition to this it was observed that the Brazilian population has 885 unique and exclusive variants. Therefore, we conclude that the Agilent\'s SureSelect kit has the best performance in the region of interest, as well as in the global exome, being recommended for studies in hypopituitarism cohorts, and that the Brazilian population has unique variants inherent to it
5

Industrialização e avaliação do método de Western blotting - WB Tp-IgG - como confirmatório na sorologia da sífilis / Industrialization and evaluation of Western blotting method - WB Tp-IgG - as confirmatory for syphilis serology

Lemos, Elaine Antunes de 17 August 2007 (has links)
A sífilis adquirida e a congênita continuam aumentando e preocupando as autoridades sanitárias do mundo, ao verem que as metas estabelecidas para o seu controle estão longe de serem atingidas. Apesar dos esforços feitos na descoberta de novas ferramentas para o diagnóstico e monitoramento da sífilis, vemos um despreparo muito grande, principalmente entre os laboratoristas, em processar corretamente os reagentes disponíveis e melhor selecionar aqueles que apresentem qualidade para serem usados na rotina do laboratório. O que constatamos neste estudo é um espelho da realidade do diagnóstico da sífilis e mostra a dificuldade que os clínicos enfrentam ao receberem um laudo do laboratório. Trabalhando em colaboração com diferentes serviços e grupos de pesquisa, selecionamos aqueles que trabalhavam com: gestantes atendidas no pré-natal, doadores de sangue, pacientes infectados pelo HIV e pacientes de laboratório clínico e fizemos um estudo crítico da sorologia utilizada em cada serviço. Verificamos discrepância dos resultados obtidos nos testes não-treponêmicos VDRL e RPR, principalmente entre os soros de baixa reatividade, e nos treponêmicos FTA-abs, TPHA e ELISA. Decidimos aplicar o método de Western blotting e analisar o seu comportamento em todas as amostras de soros ensaiadas. Para obtenção de resultados reprodutíveis, fizemos a industrialização do método e formatamos um reagente na forma de um kit diagnóstico, WB Tp-IgG, que pudesse ser facilmente utilizado e interpretado. Os resultados obtidos mostraram que o WB Tp-IgG pode ser utilizado como método confirmatório da sífilis, substituindo o FTA-abs, tradicionalmente recomendado para essa finalidade e que pudesse fazer parte de uma proposta de algoritmo para o diagnóstico sorológico da sífilis. / Acquired and congenital syphilis have been increased and worried the worldwide health authorities, mainly because the WHO targets for syphilis control are far from to be held. Much effort had been made for development of new tools to be used in syphilis diagnosis and following up, however we noticed a lack of ability of laboratory workers in the correctly choosing and using the reagents in laboratory routine. In this study what we observed were the reality of syphilis diagnosis and the difficulties that physicians have in how to procedure when they received the results from the laboratory. Working in collaboration with different settings and research groups we choose some of them that attend pregnant women, blood donors, HIV patients and patients from clinical laboratory. With these group individuals we made a critical study of the serology methods used in each one. We verified high level of discordant results between nontreponemal tests VDRL and RPR, mainly in serum samples with low reactivity and between treponemal tests FTA-abs, TPHA and ELISA, in all services. To obtain reproducibility of the results we made the industrialization of the method and set up a reagent as a kit diagnosis, easily to performer. Appling the western blotting method we evaluated the performance of the test in all sera samples assayed. The results showed that the WB Tp-IgG can be useful as confirmatory test for syphilis, replacing FTA-abs, traditionally recommended for this and that could be included in algorithm propose for serological diagnosis of syphilis.
6

Diagnóstico de laboratório da sífilis adquirida e congênita e definição das fases clínicas da doença por western-blotting / Industrialization and evaluation of Western blotting method - WB Tp-IgG - as confirmatory for syphilis serology

Lemos, Elaine Antunes de 13 September 2002 (has links)
A sífilis adquirida e a congênita continuam aumentando e preocupando as autoridades sanitárias do mundo, ao verem que as metas estabelecidas para o seu controle estão longe de serem atingidas. Apesar dos esforços feitos na descoberta de novas ferramentas para o diagnóstico e monitoramento da sífilis, vemos um despreparo muito grande, principalmente entre os laboratoristas, em processar corretamente os reagentes disponíveis e melhor selecionar aqueles que apresentem qualidade para serem usados na rotina do laboratório. O que constatamos neste estudo é um espelho da realidade do diagnóstico da sífilis e mostra a dificuldade que os clínicos enfrentam ao receberem um laudo do laboratório. Trabalhando em colaboração com diferentes serviços e grupos de pesquisa, selecionamos aqueles que trabalhavam com: gestantes atendidas no pré-natal, doadores de sangue, pacientes infectados pelo HIV e pacientes de laboratório clínico e fizemos um estudo crítico da sorologia utilizada em cada serviço. Verificamos discrepância dos resultados obtidos nos testes não-treponêmicos VDRL e RPR, principalmente entre os soros de baixa reatividade, e nos treponêmicos FTA-abs, TPHA e ELISA. Decidimos aplicar o método de Western blotting e analisar o seu comportamento em todas as amostras de soros ensaiadas. Para obtenção de resultados reprodutíveis, fizemos a industrialização do método e formatamos um reagente na forma de um kit diagnóstico, WB Tp-IgG, que pudesse ser facilmente utilizado e interpretado. Os resultados obtidos mostraram que o WB Tp-IgG pode ser utilizado como método confirmatório da sífilis, substituindo o FTA-abs, tradicionalmente recomendado para essa finalidade e que pudesse fazer parte de uma proposta de algoritmo para o diagnóstico sorológico da sífilis. / Acquired and congenital syphilis have been increased and worried the worldwide health authorities, mainly because the WHO targets for syphilis control are far from to be held. Much effort had been made for development of new tools to be used in syphilis diagnosis and following up, however we noticed a lack of ability of laboratory workers in the correctly choosing and using the reagents in laboratory routine. In this study what we observed were the reality of syphilis diagnosis and the difficulties that physicians have in how to procedure when they received the results from the laboratory. Working in collaboration with different settings and research groups we choose some of them that attend pregnant women, blood donors, HIV patients and patients from clinical laboratory. With these group individuals we made a critical study of the serology methods used in each one. We verified high level of discordant results between nontreponemal tests VDRL and RPR, mainly in serum samples with low reactivity and between treponemal tests FTA-abs, TPHA and ELISA, in all services. To obtain reproducibility of the results we made the industrialization of the method and set up a reagent as a kit diagnosis, easily to performer. Appling the western blotting method we evaluated the performance of the test in all sera samples assayed. The results showed that the WB Tp-IgG can be useful as confirmatory test for syphilis, replacing FTA-abs, traditionally recommended for this and that could be included in algorithm propose for serological diagnosis of syphilis.
7

Diagnóstico de laboratório da sífilis adquirida e congênita e definição das fases clínicas da doença por western-blotting / Industrialization and evaluation of Western blotting method - WB Tp-IgG - as confirmatory for syphilis serology

Elaine Antunes de Lemos 13 September 2002 (has links)
A sífilis adquirida e a congênita continuam aumentando e preocupando as autoridades sanitárias do mundo, ao verem que as metas estabelecidas para o seu controle estão longe de serem atingidas. Apesar dos esforços feitos na descoberta de novas ferramentas para o diagnóstico e monitoramento da sífilis, vemos um despreparo muito grande, principalmente entre os laboratoristas, em processar corretamente os reagentes disponíveis e melhor selecionar aqueles que apresentem qualidade para serem usados na rotina do laboratório. O que constatamos neste estudo é um espelho da realidade do diagnóstico da sífilis e mostra a dificuldade que os clínicos enfrentam ao receberem um laudo do laboratório. Trabalhando em colaboração com diferentes serviços e grupos de pesquisa, selecionamos aqueles que trabalhavam com: gestantes atendidas no pré-natal, doadores de sangue, pacientes infectados pelo HIV e pacientes de laboratório clínico e fizemos um estudo crítico da sorologia utilizada em cada serviço. Verificamos discrepância dos resultados obtidos nos testes não-treponêmicos VDRL e RPR, principalmente entre os soros de baixa reatividade, e nos treponêmicos FTA-abs, TPHA e ELISA. Decidimos aplicar o método de Western blotting e analisar o seu comportamento em todas as amostras de soros ensaiadas. Para obtenção de resultados reprodutíveis, fizemos a industrialização do método e formatamos um reagente na forma de um kit diagnóstico, WB Tp-IgG, que pudesse ser facilmente utilizado e interpretado. Os resultados obtidos mostraram que o WB Tp-IgG pode ser utilizado como método confirmatório da sífilis, substituindo o FTA-abs, tradicionalmente recomendado para essa finalidade e que pudesse fazer parte de uma proposta de algoritmo para o diagnóstico sorológico da sífilis. / Acquired and congenital syphilis have been increased and worried the worldwide health authorities, mainly because the WHO targets for syphilis control are far from to be held. Much effort had been made for development of new tools to be used in syphilis diagnosis and following up, however we noticed a lack of ability of laboratory workers in the correctly choosing and using the reagents in laboratory routine. In this study what we observed were the reality of syphilis diagnosis and the difficulties that physicians have in how to procedure when they received the results from the laboratory. Working in collaboration with different settings and research groups we choose some of them that attend pregnant women, blood donors, HIV patients and patients from clinical laboratory. With these group individuals we made a critical study of the serology methods used in each one. We verified high level of discordant results between nontreponemal tests VDRL and RPR, mainly in serum samples with low reactivity and between treponemal tests FTA-abs, TPHA and ELISA, in all services. To obtain reproducibility of the results we made the industrialization of the method and set up a reagent as a kit diagnosis, easily to performer. Appling the western blotting method we evaluated the performance of the test in all sera samples assayed. The results showed that the WB Tp-IgG can be useful as confirmatory test for syphilis, replacing FTA-abs, traditionally recommended for this and that could be included in algorithm propose for serological diagnosis of syphilis.
8

Industrialização e avaliação do método de Western blotting - WB Tp-IgG - como confirmatório na sorologia da sífilis / Industrialization and evaluation of Western blotting method - WB Tp-IgG - as confirmatory for syphilis serology

Elaine Antunes de Lemos 17 August 2007 (has links)
A sífilis adquirida e a congênita continuam aumentando e preocupando as autoridades sanitárias do mundo, ao verem que as metas estabelecidas para o seu controle estão longe de serem atingidas. Apesar dos esforços feitos na descoberta de novas ferramentas para o diagnóstico e monitoramento da sífilis, vemos um despreparo muito grande, principalmente entre os laboratoristas, em processar corretamente os reagentes disponíveis e melhor selecionar aqueles que apresentem qualidade para serem usados na rotina do laboratório. O que constatamos neste estudo é um espelho da realidade do diagnóstico da sífilis e mostra a dificuldade que os clínicos enfrentam ao receberem um laudo do laboratório. Trabalhando em colaboração com diferentes serviços e grupos de pesquisa, selecionamos aqueles que trabalhavam com: gestantes atendidas no pré-natal, doadores de sangue, pacientes infectados pelo HIV e pacientes de laboratório clínico e fizemos um estudo crítico da sorologia utilizada em cada serviço. Verificamos discrepância dos resultados obtidos nos testes não-treponêmicos VDRL e RPR, principalmente entre os soros de baixa reatividade, e nos treponêmicos FTA-abs, TPHA e ELISA. Decidimos aplicar o método de Western blotting e analisar o seu comportamento em todas as amostras de soros ensaiadas. Para obtenção de resultados reprodutíveis, fizemos a industrialização do método e formatamos um reagente na forma de um kit diagnóstico, WB Tp-IgG, que pudesse ser facilmente utilizado e interpretado. Os resultados obtidos mostraram que o WB Tp-IgG pode ser utilizado como método confirmatório da sífilis, substituindo o FTA-abs, tradicionalmente recomendado para essa finalidade e que pudesse fazer parte de uma proposta de algoritmo para o diagnóstico sorológico da sífilis. / Acquired and congenital syphilis have been increased and worried the worldwide health authorities, mainly because the WHO targets for syphilis control are far from to be held. Much effort had been made for development of new tools to be used in syphilis diagnosis and following up, however we noticed a lack of ability of laboratory workers in the correctly choosing and using the reagents in laboratory routine. In this study what we observed were the reality of syphilis diagnosis and the difficulties that physicians have in how to procedure when they received the results from the laboratory. Working in collaboration with different settings and research groups we choose some of them that attend pregnant women, blood donors, HIV patients and patients from clinical laboratory. With these group individuals we made a critical study of the serology methods used in each one. We verified high level of discordant results between nontreponemal tests VDRL and RPR, mainly in serum samples with low reactivity and between treponemal tests FTA-abs, TPHA and ELISA, in all services. To obtain reproducibility of the results we made the industrialization of the method and set up a reagent as a kit diagnosis, easily to performer. Appling the western blotting method we evaluated the performance of the test in all sera samples assayed. The results showed that the WB Tp-IgG can be useful as confirmatory test for syphilis, replacing FTA-abs, traditionally recommended for this and that could be included in algorithm propose for serological diagnosis of syphilis.

Page generated in 0.1036 seconds