1

The establishment of normal adult reference values for a selected panel of laboratory analytes in South Africa

Smit, Francois Christiaan January 2019 (has links)
Thesis (PhD (Biomedical Sciences))--Cape Peninsula University of Technology, 2019
2

Nutrient intake of WIC participants ages 6-28 months compared to dietary reference intakes

Turner, Kara L. January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2004. / Title from document title page. Document formatted into pages; contains vi, 67 p. : map. Includes abstract. Includes bibliographical references (p. 44-45).
3

Intervalos de referência condicionais de parâmetros dopplervelocimétricos maternofetais = Conditional reference intervals of materno-fetal Doppler parameters / Conditional reference intervals of materno-fetal Doppler parameters

Tavares, Nelsilene Mota Carvalho, 1971- 08 February 2012 (has links)
Orientadores: Ricardo Barini, Cleisson Fábio Andrioli Peralta / Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T20:27:06Z (GMT). No. of bitstreams: 1 Tavares_NelsileneMotaCarvalho_M.pdf: 1623700 bytes, checksum: 57e06ff429364aff34689dd52216eeb9 (MD5) Previous issue date: 2012 / Resumo: Objetivos: Determinar intervalos de referência condicionais (longitudinais) para os valores de índices de pulsatilidade (IP) nos fluxos da artéria umbilical (AU), cerebral média (ACM), ducto venoso (DV) e IP médio das artérias uterinas (AUT), por meio da avaliação de gestantes de baixo risco de uma amostra da população brasileira. Métodos: Estudo observacional descritivo longitudinal realizado de fevereiro de 2010 a maio de 2012, no Hospital da Mulher Prof. Dr. José Aristodemo Pinotti, Centro de Atenção Integral à Saúde da Mulher, Universidade Estadual de Campinas (CAISM-UNICAMP). Exames ultrassonográficos quinzenais foram realizados para obtenção dos IP das AU, AUT, ACM e IP venoso do DV em gestantes de baixo risco da 18ª a 40ª semana de gravidez. Análise estatística: Modelos lineares mistos foram usados para elaboração de intervalos de referência longitudinais (percentis 5, 50 e 95) dos IP dos vasos mencionados. Variáveis maternas e perinatais foram descritas com o uso de medianas e limites (variáveis contínuas), frequências absolutas e relativas (variáveis categóricas). Os IP das porções placentária e abdominal do cordão umbilical foram comparados por meio do teste T para amostras independentes. Valores de p menores do que 0,05 foram considerados significativos. Resultados: Duzentas e três gestantes de baixo risco foram incluídas no estudo. Cento e sessenta e quatro gestantes concluíram o estudo, sendo realizados 1242 exames ultrassonográficos, com mediana de oito exames por paciente (limites de 4 a 12). Houve redução significativa dos IP de todos os vasos estudados com a idade gestacional (IG). As equações obtidas para predição das medianas foram: IP-AU = 1,5602786 - (0,020623 x IG); Logaritmo do IP-ACM = 0,8149111 - (0,004168 x IG) - [0,002543 x (IG - 28,7756)2]; Logaritmo do IP-DV = 0,26691- (0,015414 x IG); IP-AUt = 1,2362403 - (0,014392 x IG). Houve diferença significativa entre os IP-AU obtidos nas extremidades placentária e abdominal fetal (p < 0,001). Conclusões: Foram estabelecidos intervalos de referência condicionais (longitudinais) dos principais parâmetros dopplervelocimétricos gestacionais em uma amostra da população brasileira. Estes podem ser mais adequados para o acompanhamento das modificações hemodinâmicas maternofetais em gestações normais ou não, a partir de uma validação / Abstract: Purpose: To determine longitudinal reference intervals of pulsatility index (PI) of the umbilical artery (UA), middle cerebral artery (MCA), uterine arteries (UTA) and ductus venosus (DV) in low risk pregnancies of the a Brazilian cohort. Methods: Longitudinal observational study performed from February 2010 to May 2012. Obstetric scans were performed fortnightly for the measurements of the PI of the UA, UTA, MCA, DV in low-risk pregnant women between 18-40 weeks of gestation. Statistical analysis: Linear mixed models were used for the elaboration of longitudinal reference intervals (5th, 50th and 95th centiles) of these measurements. Maternal and perinatal variables were described using median and range (continuous variables), absolute and relative frequencies (categorical variables). The PI obtained at the placental and abdominal portions of the umbilical artery were compared using independent samples T test. P values of less than 0,05 were considered statistically significant. Results: Two hundred and three low-risk pregnancies were included in the study. One hundred sixty four pregnant women completed the study and underwent 1242 scans. There was a significant decrease in the PI values of all studied vessels with gestational age (GA). The equations obtained for the prediction of the medians were as follows: PI-AU = 1,5602786 - (0,020623 x GA); Logarithm of the PI-MCA = 0,8149111 - (0,004168 x GA) - [0,002543 x (GA - 28,7756)2]; Logarithm of the PI-DV = - 0,26691- (0,015414 x GA); PI-UtA = 1,2362403 - (0,014392 x GA). There was a significant difference between the PI-UA obtained at the abdominal and placental ends of the umbilical cord (p < 0,001). Conclusions: Longitudinal reference intervals for the main gestational Doppler parameters were obtained from a Brazilian cohort. These intervals could be more adequate for the follow-up of materno-fetal haemodynamic modifications in normal and abnormal pregnancies, which still requires further validation / Mestrado / Saúde Materna e Perinatal / Mestre em Ciências da Saúde
4

The normal range of the leukocyte count : implications for surveillance of occupational and environmental exposure and the practice of preventive medicine.

Cropper, Charles Austin. Delclos, George L. Escobar Chaves, Soledad Liliana. January 2008 (has links)
Thesis (M.P.H.)--University of Texas Health Science Center at Houston, School of Public Health, 2008. / Source: Masters Abstracts International, Volume: 46-04, page: 2059. Adviser: George L. Delclos. Includes bibliographical references.
5

Idade gestacional e dopplervelocimetria fetoplacentária e úteroplacentária em relação ao grau placentário de grannum em gestações de baixo risco = estudo longitudinal = Gestational age and fetomaternal doppler parameters according to placenta grannum grading in low-risk pregnancies : a longitudinal study / Gestational age and fetomaternal doppler parameters according to placenta grannum grading in low-risk pregnancies : a longitudinal study

Ferreira, Sabrina Girotto, 1978- 20 August 2018 (has links)
Orientadores: Cleisson Fábio Andrioli Peralta, Ricardo Barini / Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T20:27:17Z (GMT). No. of bitstreams: 1 Ferreira_SabrinaGirotto_M.pdf: 3220177 bytes, checksum: fc5df188c73f1cc85083481b3efdcf1b (MD5) Previous issue date: 2012 / Resumo: Objetivo: Estabelecer intervalos de referência de idade gestacional (IG), índices de pulsatilidade (IP) das artérias umbilical (AU) e média das artérias uterinas (AUT) de acordo com o grau placentário de Grannum. Esses dados servirão como base para estudo em andamento que avalia o impacto do amadurecimento precoce da placenta nos parâmetros dopplervelocimétricos acima mencionados e os resultados perinatais. Sujeitos e métodos: estudo prospectivo longitudinal observacional realizado em hospital universitário terciário, em que 133 gestações de baixo risco foram avaliadas quinzenalmente pela USG, entre 18 e 41 semanas. A classificação placentária de Grannum et al. (1), IP-AU e IPm-AUT foram obtidos em cada exame. Os intervalos de referência (mediana, 5?, 10?, 90? e 95? percentil) de IG, IP-AU e IPm-AUT foram estabelecidos para cada grau placentário. Testes de Mann-Whitney com correção de Bonferroni foram utilizados para comparar os parâmetros acima mencionados entre dois diferentes graus placentários. O valor de p bicaudal menor que 0,05 foi considerado estatisticamente significativo. Resultados: A IG aumentou significativamente com a mudança do grau placentário. IP-AU e IP-AUT reduziram significativamente do grau zero para o um e do grau um para o dois, mas permaneceram estáveis depois disso. Conclusões: Os intervalos de referência dos parâmetros dopplervelocimétricos que refletem implantação normal e função placentária foram elaborados como um primeiro passo que permitirá comparar e testar nossos dados com as publicações existentes para a predição de resultados perinatais em casos de amadurecimento precoce da placenta em gestações de baixo risco / Abstract: Objective: To establish reference intervals of gestational age (GA), umbilical artery (UmbA) and mean uterine artery (mUtA) Doppler pulsatility indexes (PI) according to placental grade. This will serve as a basis for an ongoing study aimed at evaluating the impact of early placental ageing and the abovementioned Doppler parameters on pregnancy outcomes. Materials and Methods: Longitudinal observational study realized in tertiary university hospital where 133 low-risk pregnancies were scanned fortnightly from 18 to 41 weeks. Placental classification according to Grannum et al. (1), UmbA-PI and and mUtA-PI were obtained in each scan. Reference intervals (median, 5th, 10th, 90th and 95th centiles) of GA, UmbA-PI and mUtA-PI were established for each placental grade. Mann-Whitney U tests with Bonferroni adjustments were used to compare these parameters between two different placental grades. Two-tailed p-values of less than 0.05 were considered statistically significant. Results: GA significantly increased as placental grade changed. UmbA-PI and mUtA-PI significantly decreased between grades zero and one and between grades one and two, but remained stable between grades two and three. Conclusions: Reference intervals of GA and Doppler parameters which reflect normal implantation and function of the placenta were elaborated as a first step to allow further testing and comparison of our data with those previously published for the prediction of pregnancy outcomes in cases of suspicion of an early placental ageing is suspected / Mestrado / Saúde Materna e Perinatal / Mestre em Ciências da Saúde
6

Engenharia clínica aplicada à análise da variabilidade de parâmetros de referência para classificação da função pulmonar de adultos brasileiros / Clinical engineering applied to the analysis of the variability of reference parameters for classification of pulmonary function in brazilian adults

Silva, Paulo Roberto da 12 December 2016 (has links)
Uma das aplicações básicas da engenharia biomédica se refere aos testes de equipamentos de uso clínico, a avaliação de sua natureza, acessibilidade e/ou suas características. No âmbito da avaliação do sistema respiratório, estão disponíveis diferentes parâmetros de referência (PR) para o teste de espirometria, um dos principais testes de função pulmonar, que permite medir: volumes, capacidades e fluxos pulmonares. Estes PR baseiam-se principalmente em dados étnicos, idade e gênero de indivíduos saudáveis, mas havendo diferenças entre populações avaliadas, como no Brasil com sua grande diversidade de raças e etnias, pode haver erro diagnóstico. Em razão disto, o objetivo deste estudo foi analisar três dos principais PR utilizados nesta população: PR-P (de Pereira e colaboradores de 2007), PR-K ( de Knudson e colaboradores de 1983) e PR-Q (de Quanjer e colaboradores de 2012). Procedeu-se um estudo exploratório descritivo com 683 indivíduos (180 homens e 503 mulheres) entre 24 e 59 anos, em boas condições de saúde, praticantes de exercícios físicos regulares com frequência mínima de duas vezes por semana. Foi aplicada anamnese, coletados dados de massa, estatura e realizada a espirometria forçada (espirômetro bidirecional - Care Fusion MicroLoop) e as variáveis respiratórias avaliadas foram VEF1, CVF, FEF75 e PFE. Como principais resultados verificou-se que a idade média foi de 42 anos (masculino: 40,6 anos; feminino: 44,4 anos); IMC médio de 26 Kg/m² (masculino: 26,26 Kg/m²; feminino: 26,44 Kg/m²); e tempo da prática de exercícios físicos médio de 52 meses (masculino: 66,9 meses; feminino: 37,9 meses). Ao se analisar a variação dos parâmetros de referência para classificação da função pulmonar entre os três protocolos testados, encontrou-se diferença estatisticamente significativa (p<0,05) entre CVF, VEF1, FEF75 e PFE para os valores previstos e atingidos em todos os PR, além de sinais restritivos e obstrutivos. Para o PR-P, mesmo com indivíduos com características assintomáticas e praticantes de exercícios físicos, 17,2% dos indivíduos foram classificados com algum grau de restrição e 17,3% com obstrução, distanciando-se do PR-K e PR-Q que, respectivamente apresentaram valores para restritivo de 7,0% e 12,8% e para obstrutivos de 7,1% e 4,8%. Conclui-se que os respectivos PR podem induzir a erros, levando a classificações diferentes, podendo um mesmo indivíduo ser considerado em estado de normalidade, restritivo ou obstrutivo, a depender do protocolo escolhido. O estado nutricional interferiu na função respiratória no gênero masculino ao se identificar associação significativa entre o estado nutricional e o teste de função pulmonar, x² = 9,80 (p = 0,04). Desta forma, homens acima do peso tiveram 1,9 vezes mais risco de apresentar o teste de função pulmonar insuficiente, mesmo praticando exercícios físicos regulares. Não houve associação significativa em nenhum dos gêneros entre o teste de função pulmonar e o tempo de prática de exercícios físicos. O teste de correlação de Pearson, confirmou a inexistência de correlação entre as variáveis VEF1, PFE e CVF com o tempo de prática para ambos os gêneros. / One of the basic applications of biomedical engineering refers to the testing of clinical use equipment, the assessment of its nature, accessibility and / or its features. In the evaluation of the respiratory system, are available different parameters of reference (PR) for the spirometry test, one of the main pulmonary function tests, which can measure: volumes, capacities and pulmonary flows. These PR based mainly on ethnic data, age and gender in healthy subjects, but with differences between populations studied, as in Brazil with its great diversity of races and ethnic groups, there may be misdiagnosis. Because of this, the objective of this study was to analyze in this population, three of the most used PR: PR-P (Pereira et al., 2007), PR-K (Knudson et al., 1983) and PR-Q (Quanjer et al., 2012). The procedure was a descriptive exploratory study with 683 subjects (180 men and 503 women) between 24 and 59 years, in good health, regular physical exercises practitioners with minimum frequency of twice a week. Anamnesis was applied, collected data of mass and height, performed forced spirometry (bidirectional spirometer - Care Fusion Microloop) and the following respiratory variables were measured, FEV1, FVC, PEF and FEF75. With the main results it was found that the average age was 42 years (male: 40.6 years; women: 44.4 years); BMI average of 26 kg / m² (male: 26.26 kg / m²; female: 26.44 kg / m²); and time the average physical exercises practice 52 months (male: 66.9 months; female: 37.9 months). When analyzing the variation of the reference parameters for pulmonary function classification between the three protocols tested, we found a statistically significant difference (p <0.05) between FVC, FEV1, PEF and FEF75 to the levels required and achieved in all PR, as well as restrictive and obstructive signs. For the PR-P, even with individuals with asymptomatic characteristics and practitioners of physical exercises, 17.2% of subjects were classified with some degree of restriction and 17.3% with obstruction, away from the PR-K and PR-Q which respectively had values for restrictive of 7.0% and 12.8% and for obstruction of 7.1% and 4.8%. We conclude that these PR may induce to errors, leading to different rating, where one individual can be considered in normal state, restrictive or obstructive, depending on the chosen protocol. It was identified that nutritional status interfere with respiratory function, demonstrating significant association between nutritional status and pulmonary function test for males, x² = 9.80 (p = 0.04). Thus, overweight men had 1.9 times more risk to have the insufficient lung function test, even practicing regular physical exercises. There was no significant association in any of the genres between the pulmonary function test and the time of physical activity. The Pearson correlation test confirmed the lack of correlation between the FEV1, FVC and PEF with practice time for both genders.