• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação das doses de radiação em pacientes adultos e pediátricos em exames de radiodiagnóstico / Evaluation of the doses of radiation in adult patients and pediátricos in exams of radiodiagnosis

Osibote, Adelaja Otolorin January 2006 (has links)
Made available in DSpace on 2012-09-05T18:23:44Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 269.pdf: 1312690 bytes, checksum: 0f5692bc51d45c49c3d8b7f4b30b8b37 (MD5) Previous issue date: 2006 / O desenvolvimento de métodos práticos para avaliação de dose em pacientes de radiologia é desejável para os Programas de Controle e Garantia de Qualidade, inclusive a dosimetria em pacientes, que hoje em dia é um requisito legal na maioria dos países tais como o Brasil. Este trabalho apresenta os resultados de uma pesquisa realizada em pacientes adultos e pediátricos em vários hospitais no Estado do Rio de Janeiro. A Dose de Entrada na Pele (DEP), a Dose Efetiva (DE) e a Dose nos Órgãos (DO) foram avaliadas para vários exames que incluem abdômen, coluna cervical, tórax, pelve, coluna lombar, coluna torácica, ombro e crânio em projeções de AP, PA e LAT, totalizando 1085 radioias de pacientes pediátricos e 2096 radioias de pacientes adultos. Para exame pediátrico, os pacientes foram separados em quatro faixas etárias 0-1, 1-5, 5-10 e 10-15 anos. O uso de pacotes de aplicativos para determinar DEP, DE e DO é um recurso moderno em dosimetria e está sendo amplamente usado em hospitais. O software usado neste trabalho é o DoseCal, que usa os parâmetros de exposição, as características do paciente e o rendimento do tubo de raios X para a estimativa de dose de entrada na pele. Para pacientes pediátricos, foi realizado também, levantamento de dados para exames feitos nas salas da Unidade de Terapia Intensiva, UTI, que usa equipamentos de radioia móveis. O estudo na Unidade de Terapia Intensivo inclui uma pesquisa da freqüência de exames em bebês classificados de acordo com o peso ao nascimento. De um total de 621 radioias realizadas, 501 foram exames de tórax e 115 exames de abdômen. Os valores de DEP e DE variaram amplamente entre neonatos. Eles foram determinados pelo número de radioias dadas, de acordo com os sintomas clínicos
2

Estudo dos efeitos do laser infravermelho sobre a retina fotocoagulada vias transescleral e transpupilar em coelhos / Experimental analysis of photocoagulated retina using transscleral and transpupillary infrared laser

Goulart, Dario Grechi 09 September 2008 (has links)
OBJETIVOS: A fotocoagulação retiniana transpupilar (FRP) tem seu uso, freqüentemente, limitado nos casos de opacidade acentuada dos meios oculares, situações nas quais pode-se empregá-la via transescleral. O presente estudo teve como objetivo realizar pesquisa experimental com o laser de diodo semicondutor infravermelho (LDI), a fim de estimar a reprodutibilidade, a segurança e a permeabilidade da parede ocular à sua atuação clínica (PPO), quando aplicado nesta técnica. MÉTODOS: Submeteram-se 18 olhos de 9 coelhos pigmentados, todos integrantes da raça Nova Zelândia (Oryctolagulos cuniculus), à fotocoagulação retiniana por LDI. No olho direito (OD) desses animais, realizou-se fotocoagulação via transescleral (FRT) sob parâmetros de potência e tempo pré-determinados clinicamente. No olho esquerdo (OE), foram repetidos os mesmos valores da potência e tempo usados no OD, mas, desta vez, sob uso da técnica da FRP. Passados 15 minutos das aplicações e após quatro semanas, estudos clínicos, baseados na retinografia, e histopatológicos foram realizados. RESULTADOS: Existe uma constante de PPO durante aplicação da FRT, cuja taxa varia de 58,95 a 63,87%. Observou-se que a média da PPO sob 300 mW (63,14%) é significativamente superior àquela encontrada sob 500 mW (59,11%), com significância de 5%. CONCLUSÕES: Este estudo sugere a existência da relação dose-resposta em relação aos parâmetros empregados na FRT, com PPO mensurável e boa reprodutibilidade clínica. Nenhuma rotura, hemorragia ou descolamento da retina (DR) foi constatado aos exames subseqüentes às aplicações do LDI, o que torna o uso do método viável e seguro no modelo experimental / PURPOSE: Recurrently retinal photocoagulation under poor visualization condition is often required. Transscleral delivery of infrared laser can be used as an alternative to standard transpupillary treatment. Based upon clinical aspects and retinographic measurements, we proposed to estimate reproducibility as well as ocular wall permeability rate for this treatment. Our primary goal was to evaluate whether this technique can deliver adequate photocoagulation at predetermined parameters. METHODS: In New Zealand pigmented rabbits, optimal transscleral infrared diode laser settings were administered to the right eye. With the same parameters, transpupillary photocoagulation was repeated to the left eye. Retinographic and clinical examinations were performed immediately and four weeks later. RESULTS: Ocular wall permeability rate varied between 58.95 and 63.87%. Average permeability using power of 300 mW (63.14%) was found to be higher than that encountered before its enhancement up to 500 mW (59.11%), (P < 0.05). CONCLUSIONS: Setting parameters showed dose-response effect. No retinal hole or retinal detachment was noticed in any rabbit. Transscleral infrared photocoagulation appeared to be a feasible, reproducible and secure method in the experimental model
3

Estudo dos efeitos do laser infravermelho sobre a retina fotocoagulada vias transescleral e transpupilar em coelhos / Experimental analysis of photocoagulated retina using transscleral and transpupillary infrared laser

Dario Grechi Goulart 09 September 2008 (has links)
OBJETIVOS: A fotocoagulação retiniana transpupilar (FRP) tem seu uso, freqüentemente, limitado nos casos de opacidade acentuada dos meios oculares, situações nas quais pode-se empregá-la via transescleral. O presente estudo teve como objetivo realizar pesquisa experimental com o laser de diodo semicondutor infravermelho (LDI), a fim de estimar a reprodutibilidade, a segurança e a permeabilidade da parede ocular à sua atuação clínica (PPO), quando aplicado nesta técnica. MÉTODOS: Submeteram-se 18 olhos de 9 coelhos pigmentados, todos integrantes da raça Nova Zelândia (Oryctolagulos cuniculus), à fotocoagulação retiniana por LDI. No olho direito (OD) desses animais, realizou-se fotocoagulação via transescleral (FRT) sob parâmetros de potência e tempo pré-determinados clinicamente. No olho esquerdo (OE), foram repetidos os mesmos valores da potência e tempo usados no OD, mas, desta vez, sob uso da técnica da FRP. Passados 15 minutos das aplicações e após quatro semanas, estudos clínicos, baseados na retinografia, e histopatológicos foram realizados. RESULTADOS: Existe uma constante de PPO durante aplicação da FRT, cuja taxa varia de 58,95 a 63,87%. Observou-se que a média da PPO sob 300 mW (63,14%) é significativamente superior àquela encontrada sob 500 mW (59,11%), com significância de 5%. CONCLUSÕES: Este estudo sugere a existência da relação dose-resposta em relação aos parâmetros empregados na FRT, com PPO mensurável e boa reprodutibilidade clínica. Nenhuma rotura, hemorragia ou descolamento da retina (DR) foi constatado aos exames subseqüentes às aplicações do LDI, o que torna o uso do método viável e seguro no modelo experimental / PURPOSE: Recurrently retinal photocoagulation under poor visualization condition is often required. Transscleral delivery of infrared laser can be used as an alternative to standard transpupillary treatment. Based upon clinical aspects and retinographic measurements, we proposed to estimate reproducibility as well as ocular wall permeability rate for this treatment. Our primary goal was to evaluate whether this technique can deliver adequate photocoagulation at predetermined parameters. METHODS: In New Zealand pigmented rabbits, optimal transscleral infrared diode laser settings were administered to the right eye. With the same parameters, transpupillary photocoagulation was repeated to the left eye. Retinographic and clinical examinations were performed immediately and four weeks later. RESULTS: Ocular wall permeability rate varied between 58.95 and 63.87%. Average permeability using power of 300 mW (63.14%) was found to be higher than that encountered before its enhancement up to 500 mW (59.11%), (P < 0.05). CONCLUSIONS: Setting parameters showed dose-response effect. No retinal hole or retinal detachment was noticed in any rabbit. Transscleral infrared photocoagulation appeared to be a feasible, reproducible and secure method in the experimental model

Page generated in 0.118 seconds