• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Correlação entre tempo de exposição à luz, intensidade da fonte e distância entre ponteira e resina sobre as propriedades de compósito odontológico nanoparticulado

Klein Júnior, Celso Afonso January 2008 (has links)
Este trabalho avaliou a influência das variáveis: tempo de exposição à luz (20, 30, 40 e 60s), intensidade da fonte halógena (180 e 580 mW.cm-2) e distância (0, 3, 6 e 8mm) entre a fonte de luz e resina odontológica nanoparticulada (Supreme – 3MESPE) sobre as propriedades e características finais da mesma. As propriedades avaliadas foram: microdureza, resistência à compressão, resistência à compressão diametral, força de contração por polimerização, estabilidade térmica, morfologia (fractografia) e interface cavidade-material restaurador. Os resultados significativos foram os seguintes: a) o aumento do tempo e intensidade de fotoativação produz aumento da microdureza em ambas as superfícies da amostra, enquanto o aumento da distância gera uma diminuição da microdureza; b) sobre a resistência à compressão e compressão diametral: o aumento do tempo e intensidade de irradiação aumenta a resistência à compressão, enquanto o aumento da distância faz com que diminua tal resistência; c) na contração por polimerização um aumento de intensidade de irradiação provocou um aumento na contração, não tendo o tempo e a distância efeitos sobre a mesma; d) sobre a estabilidade térmica: não houve diferenças significativas entre as resinas após polimerização. Todas elas apresentam, entretanto, maior estabilidade térmica do que a resina não polimerizada. e) morfologia da superfície de fratura (fractografia): os cones de fratura ocorreram perpendicularmente à força aplicada, sendo dependentes da intensidade e distância. f) interface cavidade/resina: a intensidade é principal fator gerador de desadaptações na interface cavitária. / This work has evaluated the influence of the experimental conditions like irradiation time, source power and distance between the light source and a nanoparticle composite resin (Supreme - 3MESPE), on the properties of the polymerized resin. Such properties are: microhardness, compression strength, diametral compression strength, contraction force induced by polymerization, thermal stability, morphology (fractography) and the interface properties between restorative material and cavity. The significant and conclusive results are the following: a) the increasing time and source power causes an increasing in both sample surfaces, while an increase in irradiation distance generate a decrease in microhardness; b) about the compressions strength and diametral compression strength: increasing time and source power, the compression strength increases, while an increase in the distance between tip an sample has an opposite effect; c) in the contraction induced by polymerization an increase in the source power causes a higher contraction. Time and distance has no effect in this property; d) with respect to the thermal stability there are no significant differences between the irradiated samples, but all them are more stable that the starting resin; e) surface fracture morphology: a standard conical profile takes place under drastic irradiation conditions, mainly on source power and distance; f) resin/cavity interface: source power is the main factor to generate the failures at the interface.
12

Correlação entre tempo de exposição à luz, intensidade da fonte e distância entre ponteira e resina sobre as propriedades de compósito odontológico nanoparticulado

Klein Júnior, Celso Afonso January 2008 (has links)
Este trabalho avaliou a influência das variáveis: tempo de exposição à luz (20, 30, 40 e 60s), intensidade da fonte halógena (180 e 580 mW.cm-2) e distância (0, 3, 6 e 8mm) entre a fonte de luz e resina odontológica nanoparticulada (Supreme – 3MESPE) sobre as propriedades e características finais da mesma. As propriedades avaliadas foram: microdureza, resistência à compressão, resistência à compressão diametral, força de contração por polimerização, estabilidade térmica, morfologia (fractografia) e interface cavidade-material restaurador. Os resultados significativos foram os seguintes: a) o aumento do tempo e intensidade de fotoativação produz aumento da microdureza em ambas as superfícies da amostra, enquanto o aumento da distância gera uma diminuição da microdureza; b) sobre a resistência à compressão e compressão diametral: o aumento do tempo e intensidade de irradiação aumenta a resistência à compressão, enquanto o aumento da distância faz com que diminua tal resistência; c) na contração por polimerização um aumento de intensidade de irradiação provocou um aumento na contração, não tendo o tempo e a distância efeitos sobre a mesma; d) sobre a estabilidade térmica: não houve diferenças significativas entre as resinas após polimerização. Todas elas apresentam, entretanto, maior estabilidade térmica do que a resina não polimerizada. e) morfologia da superfície de fratura (fractografia): os cones de fratura ocorreram perpendicularmente à força aplicada, sendo dependentes da intensidade e distância. f) interface cavidade/resina: a intensidade é principal fator gerador de desadaptações na interface cavitária. / This work has evaluated the influence of the experimental conditions like irradiation time, source power and distance between the light source and a nanoparticle composite resin (Supreme - 3MESPE), on the properties of the polymerized resin. Such properties are: microhardness, compression strength, diametral compression strength, contraction force induced by polymerization, thermal stability, morphology (fractography) and the interface properties between restorative material and cavity. The significant and conclusive results are the following: a) the increasing time and source power causes an increasing in both sample surfaces, while an increase in irradiation distance generate a decrease in microhardness; b) about the compressions strength and diametral compression strength: increasing time and source power, the compression strength increases, while an increase in the distance between tip an sample has an opposite effect; c) in the contraction induced by polymerization an increase in the source power causes a higher contraction. Time and distance has no effect in this property; d) with respect to the thermal stability there are no significant differences between the irradiated samples, but all them are more stable that the starting resin; e) surface fracture morphology: a standard conical profile takes place under drastic irradiation conditions, mainly on source power and distance; f) resin/cavity interface: source power is the main factor to generate the failures at the interface.
13

Alternativas para a redução do stress de polimerização em restaurações de incremento único

Silva, Marcelo Goulart Rodrigues da January 2018 (has links)
O objetivo desta tese foi avaliar alternativas para a redução do stress de polimerização em restaurações de incremento único, através da adição de tiouretanos em resinas compostas e do uso de resinas compostas aquecidas. Para tanto, este trabalho foi dividido em três diferentes artigos com objetivos específicos, sendo eles: (1) testar o efeito da silanização de cargas inorgânicas com um novo silano contendo tiouretano em diferentes concentrações; (2) comparar o efeito da adição de tiouretano na matriz orgânica, carga silanizada ou associado à carga e matriz de resinas compostas ,experimentais; (3) testar o efeito de diferentes técnicas de incremento único utilizando resina composta préaquecida e uma resina experimental com adição de tiouretano no stress de polimerização, temperatura intrapulpar e grau de conversão. No primeiro artigo, dois diferentes tiouretanos foram sintetizados e uma carga inorgânica de vidro foi silanizada com dife rentes concentrações destes tiouretanos. O uso destas cargas em resinas compostas experimentais causou um aumento no grau de conversão e na tenacidade à fratura associado com uma redução no stress de polimerização. No segundo artigo um tiouretano foi sintetizado e adicionado em resinas compostas experimentais: 1) somente na matriz orgânica; 2) através de uma carga silanizada; ou 3) na matriz e na carga. Além disto, diferentes matrizes orgânicas foram testadas. A adição de tiouretano aumentou significativamente a tenacidade à fratura e reduziu o stress de polimerização das resinas experimentais. A associação de tiouretano na matriz e na carga potencializou a redução do stress de polimerização observado. No terceiro artigo cavidades classe I com 4mm de profundidade foram restauradas em incremento único com uma resina composta em temperatura ambiente ou aquecida, ou com uma resina experimental modificada através da adição de tiouretano na matriz e na carga, ou uma resina composta tipo "bulk-fill" de consistência regular. O préaquecimento não resultou em uma redução do stress de polimerização. Por outro lado, o material experimental contendo tiouretano apresentou uma redução significante do stress de polimerização juntamente com um aumento do grau de conversão. A incorporação de tiouretanos em novos materiais de incremento único é capaz de gerar materiais com melhores propriedades e reduzido stress de polimerização. Entretanto, o pré-aquecimento de resinas compostas não Parece uma alternativa clinicamente viável para a redução do stress de polimerização ou aumento do grau de conversão.
14

Influência do tipo de ponteira fotoativadora na microdureza de uma resina composta

Lauer, Fernanda Mello January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T20:07:28Z (GMT). No. of bitstreams: 1 304702.pdf: 56038053 bytes, checksum: 661fda1712fa76cd7a9ed5d2efe1c926 (MD5) / Este estudo teve como objetivo avaliar a influência do tipo de ponteira de unidades fotoativadoras na microdureza de uma resina composta. Para isso, foram utilizados dois aparelhos de LED (Ultraled - Dabi Atlante), alternando ponteira de polímero e fibra óptica para cada aparelho, sendo um aparelho halógeno (Ultralux - Dabi Atlante) como controle. Com o auxílio de uma matriz metálica, foram confeccionados 5 discos de resina (Filtek Z250 - 3M/ESPE) com 10mm ø e 2mm de espessura. Os discos foram submetidos a testes de microdureza Knoop imediatamente após a confecção, sendo realizadas 5 endentações com carga de 50g/15s. Após 24 horas de armazenagem em ambiente escuro a 37?C, mais 5 endentações com carga de 50g/15s foram aplicadas. Os dados obtidos foram submetidos a testes de variância Kruskal-Wallis e Mann-Whitney para comparações entre os grupos ( ?0.05). Os resultados apresentaram diferenças estatísticas entre as ponteiras bem como entre os tempos de avaliação (imediato e 24h). A ponteira de polímero apresentou média de valores de dureza superiores em relação à fibra óptica. Os valores de dureza encontrados para o tempo de 24h também foram superiores aos do tempo imediato, porém os valores encontrados no tempo imediato foram satisfatórios. Na comparação entre os grupos foi possível observar que LED2P24 > LED1P24 > LED2FO24 > LED2P i > LED1P i > QTH 24 > LED1FO24 > QTH i > LED2FO i > LED1 FO i. O tempo de 20s foi suficiente para promover adequada polimerização da resina tanto com a ponteira de polímero quanto com a de fibra óptica. Concluiu-se que as ponteiras de polímero apresentaram melhor desempenho para os tempos imediato e 24h. Entretanto, a ponteira de fibra óptica também é eficaz na polimerização da resina, porém deve-se observar o tipo e a potência do fotoativador.<br> / Abstract : The aim of this study was to compare the influence of two different light guide tips on the hardness of resin composite. Two curing light units were used (Ultraled - Dabi Atlante) alternating a fiber optic tip and a polymer tip for each unit, while a halogen light unit (Ultralux - Dabi Atlante) was used as the control group. Five resin composite (Filtek Z250 - 3M/ESPE) discs (10mm ø X 2mm thickness) were made for each group using a stainless steel matrix. Five Knoop hardness measurements were taken of each specimen's surface immediately after using a force of 50g applied for 15s, and after storing them in a dark chamber at 37?C for 24h. Statistical analyses were performed using Kruskal-Wallis and Mann-Whitney U test for comparisons among the groups ( ?0.05). The results showed statistical differences between the light guides and between times variations (immediate and 24h). The polymer light guide had an average hardness value higher than that of the optical fiber. The hardness values obtained after a time of 24 hours were also higher than the ones taken immediately, but even the values taken immediately were satisfactory. In the comparison among groups was observed that LED2P24> LED1P24> LED2FO24> LED2P i> LED1P i> QTH 24> LED1FO24> QTH i> LED2FO i> LED1FO i. The 20s time was enough to promote adequate polymerization of the resin with either the polymer light guide or the fiber optics. It is concluded that the polymer light guide showed better performance immediately and after 24h time. However, the fiber optic probe is also effective in curing the resin, but one should observe the type and the power of the light curing unit.
15

Alternativas para a redução do stress de polimerização em restaurações de incremento único

Silva, Marcelo Goulart Rodrigues da January 2018 (has links)
O objetivo desta tese foi avaliar alternativas para a redução do stress de polimerização em restaurações de incremento único, através da adição de tiouretanos em resinas compostas e do uso de resinas compostas aquecidas. Para tanto, este trabalho foi dividido em três diferentes artigos com objetivos específicos, sendo eles: (1) testar o efeito da silanização de cargas inorgânicas com um novo silano contendo tiouretano em diferentes concentrações; (2) comparar o efeito da adição de tiouretano na matriz orgânica, carga silanizada ou associado à carga e matriz de resinas compostas ,experimentais; (3) testar o efeito de diferentes técnicas de incremento único utilizando resina composta préaquecida e uma resina experimental com adição de tiouretano no stress de polimerização, temperatura intrapulpar e grau de conversão. No primeiro artigo, dois diferentes tiouretanos foram sintetizados e uma carga inorgânica de vidro foi silanizada com dife rentes concentrações destes tiouretanos. O uso destas cargas em resinas compostas experimentais causou um aumento no grau de conversão e na tenacidade à fratura associado com uma redução no stress de polimerização. No segundo artigo um tiouretano foi sintetizado e adicionado em resinas compostas experimentais: 1) somente na matriz orgânica; 2) através de uma carga silanizada; ou 3) na matriz e na carga. Além disto, diferentes matrizes orgânicas foram testadas. A adição de tiouretano aumentou significativamente a tenacidade à fratura e reduziu o stress de polimerização das resinas experimentais. A associação de tiouretano na matriz e na carga potencializou a redução do stress de polimerização observado. No terceiro artigo cavidades classe I com 4mm de profundidade foram restauradas em incremento único com uma resina composta em temperatura ambiente ou aquecida, ou com uma resina experimental modificada através da adição de tiouretano na matriz e na carga, ou uma resina composta tipo "bulk-fill" de consistência regular. O préaquecimento não resultou em uma redução do stress de polimerização. Por outro lado, o material experimental contendo tiouretano apresentou uma redução significante do stress de polimerização juntamente com um aumento do grau de conversão. A incorporação de tiouretanos em novos materiais de incremento único é capaz de gerar materiais com melhores propriedades e reduzido stress de polimerização. Entretanto, o pré-aquecimento de resinas compostas não Parece uma alternativa clinicamente viável para a redução do stress de polimerização ou aumento do grau de conversão.
16

Correlação entre tempo de exposição à luz, intensidade da fonte e distância entre ponteira e resina sobre as propriedades de compósito odontológico nanoparticulado

Klein Júnior, Celso Afonso January 2008 (has links)
Este trabalho avaliou a influência das variáveis: tempo de exposição à luz (20, 30, 40 e 60s), intensidade da fonte halógena (180 e 580 mW.cm-2) e distância (0, 3, 6 e 8mm) entre a fonte de luz e resina odontológica nanoparticulada (Supreme – 3MESPE) sobre as propriedades e características finais da mesma. As propriedades avaliadas foram: microdureza, resistência à compressão, resistência à compressão diametral, força de contração por polimerização, estabilidade térmica, morfologia (fractografia) e interface cavidade-material restaurador. Os resultados significativos foram os seguintes: a) o aumento do tempo e intensidade de fotoativação produz aumento da microdureza em ambas as superfícies da amostra, enquanto o aumento da distância gera uma diminuição da microdureza; b) sobre a resistência à compressão e compressão diametral: o aumento do tempo e intensidade de irradiação aumenta a resistência à compressão, enquanto o aumento da distância faz com que diminua tal resistência; c) na contração por polimerização um aumento de intensidade de irradiação provocou um aumento na contração, não tendo o tempo e a distância efeitos sobre a mesma; d) sobre a estabilidade térmica: não houve diferenças significativas entre as resinas após polimerização. Todas elas apresentam, entretanto, maior estabilidade térmica do que a resina não polimerizada. e) morfologia da superfície de fratura (fractografia): os cones de fratura ocorreram perpendicularmente à força aplicada, sendo dependentes da intensidade e distância. f) interface cavidade/resina: a intensidade é principal fator gerador de desadaptações na interface cavitária. / This work has evaluated the influence of the experimental conditions like irradiation time, source power and distance between the light source and a nanoparticle composite resin (Supreme - 3MESPE), on the properties of the polymerized resin. Such properties are: microhardness, compression strength, diametral compression strength, contraction force induced by polymerization, thermal stability, morphology (fractography) and the interface properties between restorative material and cavity. The significant and conclusive results are the following: a) the increasing time and source power causes an increasing in both sample surfaces, while an increase in irradiation distance generate a decrease in microhardness; b) about the compressions strength and diametral compression strength: increasing time and source power, the compression strength increases, while an increase in the distance between tip an sample has an opposite effect; c) in the contraction induced by polymerization an increase in the source power causes a higher contraction. Time and distance has no effect in this property; d) with respect to the thermal stability there are no significant differences between the irradiated samples, but all them are more stable that the starting resin; e) surface fracture morphology: a standard conical profile takes place under drastic irradiation conditions, mainly on source power and distance; f) resin/cavity interface: source power is the main factor to generate the failures at the interface.
17

Efeito do tempo e tipo de fotoativação e da ciclagem mecanica e termica na infiltração marginal de restaurações adesivas / Effect of light polimerization mode, time and mechanical and thermal load cycling on microleakage in adhesive restorations

Soares, Giulliana Panfiglio, 1981- 13 August 2018 (has links)
Orientadores: Flavio Henrique Baggio Aguiar, Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:37:42Z (GMT). No. of bitstreams: 1 Soares_GiullianaPanfiglio_M.pdf: 730604 bytes, checksum: 4496655ec779f61c3be30cc95bf5663a (MD5) Previous issue date: 2009 / Resumo: A manutenção da integridade entre dente e restauração é importante para o sucesso clínico de restaurações adesivas, influenciando a longevidade das mesmas. Assim, o objetivo deste trabalho "in vitro", composto por dois experimentos, foi avaliar a infiltração marginal em cavidades Classe II: 1) confeccionadas com um sistema adesivo e compósito dental, variando a fonte de luz e o tempo de fotoativação do sistema adesivo, submetidos aos testes de ciclagem mecânica e térmica; 2) confeccionadas com um sistema adesivo e um compósito dental, variando a fonte de luz e o tempo de fotoativação da resina composta, submetidos ou não aos testes de ciclagem mecânica e térmica. Para tanto foram utilizados 270 dentes bovinos no qual foram realizadas restaurações Classe II variando o aparelho e o tempo de fotoativação, aplicado no sistema adesivo ou resina composta. Após isto, as restaurações foram submetidas ao teste infiltração marginal. De acordo com os resultados obtidos (Análise de Variância (p=0,05) e teste de Tukey) e sob as condições experimentais deste estudo, pôde-se concluir que: 1) o aumento do tempo de fotoativação do sistema adesivo não mostrou melhores resultados no processo de infiltração marginal, independente da fonte luz utilizada; 2) o aumento do tempo de fotoativação da resina composta não mostrou melhores resultados no processo de infiltração marginal, independente da fonte luz utilizada; 3) a utilização de aparelhos fotopolimerizadores com maiores intensidades de luz não mostrou melhores resultados quando comparados ao de menor intensidade, quando utilizados paar fotoativação da resina composta; 4) houve aumento da infiltração marginal após os testes de ciclagem mecânica e térmica nos grupos LED 3a geração e halógena quando estes foram utilizados para fotoativação da resina composta. / Abstract: The maintenance of the bond integrity between tooth and resin systems is important for the clinical success of composite resin restorations. Thus, the aim of this "in vitro" study composed of two manuscripts, was to evaluate the microleakage of Class II dental restorations: 1) made with an adhesive system and a dental composite, varying light curing time and light curing modes of the adhesive system, submitted to the thermal and mechanical loading cycling; 2) made with an adhesive system and a dental composite, varying light curing time and light curing modes of the resin, submitted or not to the thermal and mechanical loading cycling. 270 bovine teeth were used for this study, and prepared Class II restorations varying the time and the light curing modes for the adhesive or composite resin. After that, the restorations were submitted to the microleakage test. Based on the results (Analysis of Variance (p=0,05) and Tukey test), within the experimental limits of this study, it can be concluded that: 1) the increase of the light curing time of an adhesive system did not show better results in the process of marginal microleakage, regardless the light curing modes used; 2) increasing the photoactivation time of the resin composite did not reduce the microleakage of the cervical interface of the restoration, regardless the light curing modes used; 3) use of light curing units with high irradiance did not show better results when compared with low irradiant energy, for the two first layers of resin composite; 4) the thermal and mechanical loading cycling increased the microleakage in groups LED 3a generation and Conventional (QTH) for the two first layers of resin composite. / Mestrado / Dentística / Mestre em Clínica Odontológica
18

Efeito de metodos de contensão da mufla metalica e do tempo pos-prensagem na adaptação da base de protese total / Effect of flask closure method and post-pressing time on the denture base adaptation

Lira, Andrea Fabiana de 28 February 2007 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T18:24:15Z (GMT). No. of bitstreams: 1 Lira_AndreaFabianade_M.pdf: 707416 bytes, checksum: 69b11fb51b91c668991278766f976aa6 (MD5) Previous issue date: 2007 / Resumo: O propósito deste trabalho foi estudar o efeito de métodos de contensão da mufla metálica (grampo convencional e sistema RS de contensão) e do tempo pós-prensagem (imediato e 6 horas) nos níveis de adaptação da base de prótese total superior confeccionada com as resinas acrílicas ativadas termicamente Clássico (Clássico) e QC-20 (Dentsply). Foram confeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 8 grupos (n=10), de acordo com os métodos de contensão de mufla metálica e do tempo pós-prensagem. As resinas acrílicas foram proporcionadas e manipuladas de acordo com as instruções dos fabricantes e prensadas na fase plástica, com carga inicial de 850 kgf e final de 1250 kgf em prensa hidráulica de bancada. As bases confeccionadas em resina Clássico foram polimerizadas em ciclo de água a 74?C por 9 horas e as bases de resina QC-20 em água em ebulição por 20 minutos. Depois de esfriadas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionadas em três secções, correspondentes à distal de caninos, mesial de primeiros molares e região palatina posterior. Em cada secção, o desajuste entre modelo de gesso e base de resina foi verificado nos pontos referenciais fundo de sulco vestibular direito e esquerdo, crista do rebordo alveolar direito e esquerdo e linha mediana palatina posterior, com microscópio comparador linear Olympus, com precisão de 0,0005 mm. Os resultados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). O dispositivo RS produziu níveis médios de adaptação com diferença estatística significante quando comparado com o grampo convencional, independente dos demais fatores. O dispositivo RS produziu níveis médios de adaptação nos tempos imediato e 6 horas com diferença estatística significante quando comparado com o grampo convencional. A polimerização imediata produziu valores entre cortes sem diferença estatística significativa quando comparada com a polimerização após 6 horas. Quando os cortes foram analisados no fator prensagem, os melhores níveis de adaptação foram obtidos com o dispositivo RS, com diferença estatística significativa quando comparado com o grampo convencional. Os tratamentos RS e convencional apresentaram comportamento semelhante, independente da resina, mas foram diferentes no tempo pós-prensagem. A região posterior apresentou maiores valores de desadaptação em ambas as resinas, independente do tipo de contensão da mufla e do tempo pós-prensagem / Abstract: The purpose of this study was to verify the effect of flask closure method (conventional clamp and RS tension system) and post-pressing time (immediate and after 6 hours) on the maxillary denture base adaptation made with Classico and QC-20 heat?cured acrylic resins. Eighty maxillary stone cast/wax base sets were made and randomly assigned into 8 groups (n=10) according to the flask closure method and post- pressing time. The acrylic resins were proportioned and manipulated following the manufacturer?s instructions and flask pressed in the doughlike stage with an initial load of 850 kgf and final load of 1,250 kgf in hydraulic press. Classico acrylic resin was submitted to polymerization in water at 74°C during 9 hours in immediate or after 6 hour post-pressing times. QC-20 acrylic resin was submitted to polymerization in boiling water for 20 minutes. After bench cooling the resin bases were deflasked, finished, and fixed on the casts with instantaneous adhesive. The cast-resin base sets were laterally sectioned in the regions corresponding to the distal of canines (A), mesial of first molars (B), and posterior palatal zone (C). The gap between the stone cast and resin base was measured with an Olympus comparative microscope with accuracy of 0.0005mm at five referential points for each section. Data submitted to ANOVA and Tukey?s test (5%) showed that the RS system produced medium levels of adaptation with statistically significant difference when compared to the conventional clamp, independent of the other factors. RS system produced levels of adaptation in the immediate and 6 hours post-pressing times with statistical significant difference when compared to the conventional clamp. The immediate polymerization produced values among cuts without statistical difference when compared to the polymerization after 6 hours. When the cuts were analyzed in the factor flask pressure method, the best levels of adaptation were showed with the RS system, with statistical significant difference when compared to the conventional clamp. The RS system and conventional clamp treatments showed similar results independent of the resin factor; however they were different in the post-pressing time. The posterior region showed greater values of desadaptation in both resins, independent of the flask closure method and post-pressing time / Mestrado / Protese Dental / Mestre em Clínica Odontológica
19

Avaliação da resistência à tração de uma resina composta fotopolimerizável em função de diferentes fontes de luz e de tempos de ativação / Evaluation of tensile strength of a photo polymerizing resin composite, as related to different sources of light and activation times

Virginia Bosquiroli 24 February 2003 (has links)
O objetivo deste estudo foi avaliar a resistência à tração de uma resina composta fotopolimerizada por diferentes fontes de luz e por diferentes tempos de ativação. Deste modo, foi utilizado um aparelho de luz halógena Curing Light 2500- 3M (670mW/cm2) e outro do tipo LED Ultraled - Dabi-Atlante (130mW/cm2). Para confecção dos corpos de prova utilizou-se um conjunto de matrizes de aço inoxidável, composto de duas partes, sendo que cada parte apresentava um orifício central cônico com 8,0mm de diâmetro maior e 6,0mm de diâmetro menor e 1,0mm de espessura. A resina composta utilizada foi a Z-250 (3M) nas cores A1 e A4. Foram confeccionados oito grupos de 10 espécimes, sendo quatro grupos fotopolimerizados com luz halógena e quatro com LED. Para luz halógena, dois grupos com resina Z-250 na cor A1, com tempos respectivos de 20s (G1) e 40s (G2) e dois grupos com cor A4, com tempos de 40s (G3) e 80s (G4). Da mesma forma para o LED; dois grupos com a resina Z-250 na cor A1, com tempos de 20s (G5) e 40s (G6) e dois grupos na cor A4, com tempos de 40s (G7) e 80s (G8) respectivamente. Dez minutos após a obtenção dos espécimes o conjunto foi adaptado a um dispositivo especial para permitir o acoplamento junto a uma máquina de ensaios universal e a realização do ensaio de tração, numa velocidade de movimento de 0,5mm/min. Os valores obtidos foram submetidos à análise de variância ANOVA a dois critérios sendo estes, fonte de luz e tempo de polimerização. As médias e desvios padrão foram respectivamente: G1 - 14,13 ± 2,03; G2 - 13,85 ± 2,46; G3 - 14,21 ± 2,31; G4 - 14,42 ± 1,97; G5 -12,95 ± 1,09; G6 - 13,46 ± 2,02; G7 - 12,99 ± 1,29; G8 -14,25 ± 2,8. Concluiu-se que: (1) O aparelho fotopolimerizador LED foi tão efetivo na polimerização da resina composta quanto o aparelho de luz halógena. (2) O aumento do tempo de polimerização não exerceu influência na resistência à tração da resina composta, independente do tipo de aparelho fotopolimerizador e da cor do material. (3) A resistência à tração para a resina Z250 nas cores A1 e A4 não foi afetada pela variação do tempo de polimerização e pelas fontes de luz halógena e LED. / The aim of this study was to evaluate the te nsile strength of the composite resin by different light units and different activation times. So, a conventional light curing unit, Curing Light 2500- 3M (670mw/cm2) and another LED type (light emitting diode) Ultraled Dabi Atlante(130mw/ cm2) were used. To obtain the specimens a set of stainless matrix composed by two parts was used, each one presenting a conic central orifice measuring 6.0mm of smaller diameter and 8.0mm of larger diameter with 1.0mm in depth. The composite resin utilized was the Z250-3M in A1 and A4 shades. Eight groups with ten specimens each were made; four of which polymerized with halogen light cure and the other four with LED. For the halogen light cure unit, two groups with the Z250 A1 shade, with the respective cure times of 20s(G1) and 40s (G2) and two groups with A4 shade, with cure times of 40 s (G3) and 80 s (G4) were used. The same was done with the LED groups: two groups with the Z-250 shade A1, with 20 s (G5) and 40 s (G6) and two groups with shade A4, with cure times of 40s (G7) and 80s (G8) respectively. Ten minutes after obtaining the specimens the set was adapted to a special device to allow for adaptation at the universal testing machine and then the tensile test was done at a cross speed of 0,5mm/min. The obtained values were submitted to a two-way variation ANOVA analysis. The means and standard deviation were respectively: G1 - 14,13 ± 2,03; G2 - 13,85 ± 2,46; G3 - 14,21 ± 2,31; G4 - 14,42 ± 1,97; G5 - 12, 95 ± 1,09; G6 - 13,46 ± 2,02; G7 - 12,99 ± 1,29; G8 - 14, 25 ± 2,89. It is concluded that: (1) The LED photo polymerizing unit was as effective for the polymerization of resin composite as the halogen light unit. (2) The increase in polymerization time did not exert an influence on the resin composite tensile strengths, no matter what kind of light source was used nor the material color. (3) The tensile strength for the Z250 resin, colors A1 and A4, was not affected by the activation time variation nor the sources of halogen and LED lights.
20

Avaliação das forças geradas durante a contração de polimerização de resinas compostas, em função do tipo de resina composta, modo de ativação, fonte de luz e utilização de material intermediário

Juan Carlos Castañeda-Espinosa 01 March 2005 (has links)
As forças geradas durante a polimerização das resinas estão relacionadas a vários fatores, sendo de muita importância a avaliação das forças que podem alcançar a interface adesiva nestas restaurações. O objetivo deste trabalho foi determinar estas forças, em função da composição e modo de ativação da resina, fonte de luz utilizada na ativação, e presença de material intermediário. Foram utilizadas duas bases de aço em forma retangular (6 x 2 mm), posicionadas paralelamente, sendo uma conectada ao braço móvel da máquina de ensaios (Emic – DL 500), através de uma célula de carga de 10 Kgf, e outra ao braço fixo. As resinas compostas foram introduzidas entre as bases metálicas, com 1 mm de altura, volume de 12 mm3 e fator C 1,5. As bases ficaram fixas durante o ensaio, e as forças geradas durante a polimerização foram registradas através de uma curva força/tempo, num total de dez ensaios para cada grupo. Foi avaliada a resina quimicamente ativada Concise (3M), as fotoativadas de micropartículas Filtek A-110 (3M), microhíbrida Filtek Z-250 (3M) e de alta viscosidade Filtek P-60 (3M). Dentre os aparelhos fotoativadores, foi avaliado o halógeno Spectrum (Dentsply), e os LEDs Ultraled (Dabi-Atlante) e Ultrablue IS (DMC). Os materiais intermediários avaliados foram o cimento de íonômero de vidro modificado por resina Vitrebond (3M) e a resina de baixa viscosidade Filtek Flow (3M). Os resultados mostraram que a resina quimicamente ativada Concise apresentou a menor força de contração de polimerização (4,216 + 0,353N), sendo este valor significantemente menor àqueles apresentados pelas resinas compostas fotoativadas (p<0,05). A resina de micropartículas Filtek A-110 apresentou a maior média dentre as resinas fotoativadas (8,365 + 0,5956N), sem diferenças estatisticamente significativas com Filtek P-60 (8,111 + 0,6868N) (p>0,05) e com diferenças estatisticamente significativas em relação a Filtek Z-250 (7,500 + 0,6149N) (p<0,05). Dentre os aparelhos fotoativadores o grupo polimerizado com Ultraled apresentou media significantemente menor que os outros grupos avaliados (5,175 + 0,3480N) (p<0,05). O grupo polimerizado com Spectrum (6,316 + 0,2175N) não apresentou diferenças estatisticamente significativas em relação a Ultrablue IS (p>0,05). Os grupos fotoativados com Ultrablue IS, a densidades de potência de 300 e 600 mW/cm2 (6,108 + 0,2252N e 6,497 + 0,2565N respectivamente) mostraram diferenças estatisticamente significativas entre eles (p<0,05). Finalmente, os resultados mostraram que existiram diferenças estatisticamente significativas entre os valores de forças de contração que foram registrados para a resina composta Filtek Z-250 com e sem material intermediário (p<0,05), sendo esta diferença positiva para o Vitrebond e negativa para o Filtek Flow. Pode-se concluir que todas as variáveis estudadas influíram significativamente nas forças de contração de polimerização em maior ou menor grau. / The aim of this study was to verify the influence of the type of composite resin (chemical-cured and three different type of photo-cured composite); the type of photocuring unit (halogen and LED); and the type and thickness of different intermediate materials (flowable composite and resin modified glass ionomer) on the polymerization contraction forces transmitted to an universal testing machine. The experiment set up consisted of two identical steel bases one of which was connected to the cross head of an universal testing machine and the other was fixed to the transversal base. Composite resin was inserted into a 1mm space between the steel bases or between the inferior steel base and a previously polymerized layer of an intermediate material adhered to the upper steel base. The resin composite was light-cured with a QTH or LED curing unit for 60s and a curve force/time was obtained for each of the ten samples. The data were statistically evaluated using one way ANOVA and Tukey tests (p< 0,05). It was observed that the chemical-cured Concise produced the lower means of polymerization contraction forces; The photo-cured composites developed forces at the moment photoactivation began and for the whole evaluated period. Polymerization contraction forces were more dependent of power density than of the light source (halogen or LED). The use of resin modyfied glass ionômer as an intermediate layer promoted a significant decrease in the polymerization contraction force values of the restorative system, regardless of layer thickness. The use of flowable composite as an intermediate layer promoted an increase in polymerization contraction force values of the restorative system with the two evaluated layer thicknesses.

Page generated in 0.0871 seconds