Spelling suggestions: "subject:"desistência dde materiais"" "subject:"desistência dee materiais""
61 |
Influencia da temperatura de tres sistemas adesivos na resistencia de união e na interação com esmalte bovino abrasionado / The influence of temperature of three adhesive systems on bonding to ground enamelAlexandre, Rodrigo Sversut de 03 October 2009 (has links)
Orientador: Jose Roberto Lovadino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T11:05:09Z (GMT). No. of bitstreams: 1
Alexandre_RodrigoSversutde_M.pdf: 5656736 bytes, checksum: 13f53feb57ad1569d4d4d53ef1d4e6b6 (MD5)
Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar a influência da temperatura do adesivo na resistência à microtração (µT) de um convencional de frasco único, Primer &Bond NT(PBNT) e dois adesivos autocondicionante,Clearfil SE Bond (SEB) e Adper Prompt L-Pop (PLP). Adicionalmente, foram analisados o padrão de condicionamento (PC) e a interface resina-esmalte (IRE). Foram utilizados 63 dentes bovinos divididos em 3 grupos (n=21) de acordo com o adesivo. Cada grupo foi subdividido em 3 sub-grupos de acordo com a temperatura do adesivo (NORM = 20°C; FRIO = 5°C; QNT = 40°C). Os dentes tiveram sua face vestibular média planificada com lixas de granulação 320, 400 e 600 de SiC e abrasionada com uma ponta diamantada por 10s. Os sistemas adesivos foram aplicados segundo as instruções do fabricante e a resina composta em incrementos 2mm de espessura. Cada incremento foi polimerizado por 40s. Em seguida, os espécimes foram cortadas no sentido mésio-distal, sendo a metade cervical destinada a análise da interface e a incisal destinada ao teste de µT , realizado em máquina de ensaio universal. Para cada espécime, 4 amostras do tipo "Hour Glass" foi testado e o padrão de fratura avaliado. Para o PC foram confeccionados 2 blocos para cada subgrupo (14), os quais receberam o mesmo tratamento de superfície dos espécimes utilizados para o teste de µT, porém as superfícies foram lavadas após a aplicação da solução ácida . Para a análise da interface, estas foram polidas e limpas através da aplicação de plasma de argônio e foram, juntamente com os espécimes do padrão de condicionamento, preparados para visualização em MEV. Os valores de resistência à µT foram analisados pelo teste ANOVA/Tukey (p<0,05). Na temperatura NORM não houve diferença estatística entre os adesivos, porém no FRIO a resistência à µT dos adesivos PBNT e PLP foram menores que a do SEB. Na temperatura QNT houve uma redução na resistência à µT dos adesivos SEB e PLP. Dentro de cada adesivo, o SEB aquecido, foi o único que reduziu sua resistência. O padrão de fratura mostrou maior incidência de fraturas coesivas em esmalte para o adesivo PBNT. Porém, os adesivos autocondicionantes mostraram uma predominância de fraturas adesivas/ coesivas e adesivas. O aspecto da interface e do padrão de condicionamento foi dependente da temperatura e do adesivo. O grupo PLP foi o que mais se aproximou do grupo com condicionamento ácido prévio, porém apenas na temperatura ambiente. Através dos resultados deste estudo, pode-se concluir que os adesivos autocondicionantes apresentam menor agressividade de desmineralização em relação ao ácido fosfórico e são influenciados pela alteração da temperatura. / Abstract: This study evaluated the influence of adhesive temperature on microtensile (µT) bond strength of a total-etch adhesive, Primer&Bond NT (PBNT) and two self-etching adhesives, Clearfil SE Bond (SEB) and Adper Prompt L-Pop (PLP). Additionally, the etch patterns (EP) and resin-enamel interface were analyzed. Sixty-three bovine incisors were randomly divided into 3 experimental groups (N=21) according to the adhesive. Each group was subdivided into 3 sub-groups according to the temperature (NORM = 20°C; FRIO = 5°C; QNT = 40°C). The buccal enamel surfaces were flattened with 320, 400, 600-grit SiC paper and abrasioned with a diamond bur for 10s under water coolant. The adhesive were applied according to the manufacturers' instructions and resin was incrementally placed in 2mm thick. Each resin increment was light cured for 40s. The specimens were sectioned in the middle. For the µT test was used incisal center, accomplished in a universal testing machine, 4 "hour glass" type specimens were tested, after was fractures type classified. The cervical middle was used for interface analyze. The sections were polished and cleanned with Argon Plasma. For the EP, 24 fragments received the same treatment of the specimens used for µT, but the surface was rinsed off after the application of the acidic solutions. EP and interface analyze were examined under a scanning electron microscope (SEM). The bond strength data were analyzed by ANOVA/Tukey test (p<5%). No significant differences were found for NORM adhesives. However, for FRIO, PBNT and APLP presented the lower bond strength means significantly differing from SEB. For QNT, the SEB and PLP presented the lowest bond strength means. Within each adhesive, the SEB used in a QNT, was the only one to present a reduction in a bond strength. There was a more enamel cohesive fracture type to PBNT. However, the self-etching adhesive presented adhesive/cohesive fracture types. The interface aspect was temperature and adhesive depended. When the APLP was applied in normal temperature there was greater similarity with the group PBNT. The result of this study was concluded that the self-etching showed a least aggressive etch patterns in relation to the Phosphoric acid and temperature change influenced adhesive µT bond strength and EP. However, they were adhesive and temperature dependent. / Mestrado / Dentística / Mestre em Clínica Odontológica
|
62 |
Efeito do numero de ciclos termicos sobre a deformação permanente de materiais reembasadores resilientes e sua resistencia a tração da união com a resina acrilicaPinto, Jose Renato Ribeiro 11 July 2002 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:45:26Z (GMT). No. of bitstreams: 1
Pinto_JoseRenatoRibeiro_D.pdf: 3564212 bytes, checksum: a1dc81c846bf56c322b5ab2a519b1da2 (MD5)
Previous issue date: 2002 / Resumo: O objetivo deste estudo foi avaliar o efeito do número de ciclos térmicos sobre a deformação permanente e resistência à tração da união com resina acrílica, de reembasadores resilientes definitivos usados como forradores de bases de próteses: um à base de silicone (Softliner), e outro à base de resina acrílica (Eversoft). Para o ensaio de resistência à tração da união, estes materiais foram unidos a uma resina acrílica (QC-20), e para o de deformação, não. Para a confecção das amostras foram utilizadas matrizes metálicas (40 x 10 x 10 e 13 x 19 mm) incluídas em mufla, cujo molde impresso na silicone por condensação e no gesso foi preenchido com resina acrílica e/ou material resiliente. Foram confeccionadas 400 amostras, metade para o ensaio de resistência à tração da união e metade para o de deformação permanente, divididas em 10 grupos, com 10 amostras por material para o ensaio de tração, e 10 para o de deformação permanente: grupo I - não submetido à termociclagem (grupo controle); grupo II -200 ciclos; grupo III - 500 ciclos; grupo IV - 1000 ciclos; grupo V - 1500 ciclos; grupo VI - 2000 ciclos; grupo VII ¿2500 ciclos; grupo VIII - 3000 ciclos; grupo IX -3500 ciclos e grupo X - 4000 ciclos. O tratamento térmico foi realizado no aparelho termociclador MSCT-3 plus com ciclos de imersão de 1 minuto em água a 5°C (± l°C) e 1 minuto em água a 55°C (±1°C). Para o ensaio de resistência à tração da união, as amostras foram adaptadas às garras autotravantes de uma máquina de ensaios universal EMIC DL-500 MF, com velocidade de 5 mm/minuto. Para o ensaio de deformação permanente, foi utilizado um dispositivo mecânico descrito na especificação nº 18 da A.D.A. Os dados obtidos foram submetidos à análise de variância (ANOVA) e as médias comparadas pelo Teste de Tukey, em nível de 5% de probabilidade, e as amostras do ensaio de resistência à tração da união, observadas quanto ao tipo de falha ocorrida (adesiva, coesiva ou mista). O material Softliner submetido aos diferentes números de ciclos térmicos não apresentou diferença estatística nos valores de resistência à tração da união, entretanto, o material Eversoft, quando se comparou o grupo controle (0,47 MPa) e o de 500 ciclos (0,46 MPa) com o de 4000 ciclos térmicos (0,70 MPa), observou-se aumento dos valores de resistência à tração da união, com significância estatística. Quanto ao tipo de falha, observou-se que: Eversoft apresentou maior porcentagem de falha adesiva e mista. Já, a base resiliente Softliner, apresentou 100% de falha adesiva. Para o ensaio de deformação permanente, independente do tratamento recebido, o material Eversoft apresentou o valor mais elevado (2,27%) e diferiu estatisticamente do Softliner (0,38%). A termociclagem promoveu a elevação gradativa da porcentagem de deformação permanente apenas para o material à base de resina acrílica, diferindo estatisticamente a partir dos 1500 ciclos térmicos (1,88%) e respectivamente nos grupos dos 2000 (2,19%), 2500 (2,57%), 3000 (2,85%) e 3500 ciclos (3,24%). O grupo dos 4000 ciclos (3,45%) não apresentou diferença estatística significativa se comparado com o dos 3500 ciclos / Abstract: The purpose of this study was to evaluate the effect of thermal cycling on the tensile bond strength and the permanent deformation of two soft denture liner materiaIs (one silicone - Softliner and one acrylic resin - Eversoft). In the first study (tensile bond strength), one acrylic resin (QC-20) for denture base was used. For each study was used 200 samples divided in 10 groups, with 10 samples for each material: group I - not thermocycled (control group); group II- 200 cycles; group III - 500 cycles; group IV - 1000 cycles; group V - 1500 cycles; group VI ¿ 2000 cycles; group VII - 2500 cycles; group VIII - 3000 cycles; group IX - 3500 cycles and group X - 4000 cycles. The thermal cycling was made in the machine MSCT-3 plus where cycles of 1 minute in water at 5°C (± l°C) and 1 minute of water at 55°C (± l°C) were made. For the making of the samples, metallic dies (40 x 10 x 10 and 13 x 19 mm) were used invested in flasks, whose model impressed in the silicone of the condensation and in the gypsum was filled up with acrylic resin and/or soft materiaIs. After each period, the samples of the first study were submitted to a tensile bond strength test in a universal testing machine (EMIC DL-500 MF) at the crosshead speed of 5 mm / minute. The samples of the second study were submitted to a permanent deformation test in a mechanic machine described in the A.D.A.' s specification nº 18. The obtained results were submitted to the variance analyses (ANOVA) and to the Tukey' s Test, at the leveI of 5% of probability and the tensile bond strength samples were analyzed according to the kind of failure occurred. Based in the results of the tensile bond strength study, the Softliner material submitted to the thermal treatments didn't presented values of the bond strength with statistical difference, however Eversoft presented a significant statistical difference in the control group (0.47 MPa) and the group of the 500 cycles (0.46 MPa) when compared with the group of the 4000 cycles (0.70 MPa). The Eversoft material presented adhesive and mixed failures. The Softliner material presented 100% of adhesive failures. Based in the results of the permanent deformation study, when we observe the averages of the values independent the treatment was used, the Eversoft material presented the highest values (2.27%) and the Softliner presented the lowest (0.38%). To the acrylic resin soft denture material the thermal cycling increased the values of permanent deformation, however were observed a significant statistical difference only after the group of 1500 cycles / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
63 |
Avaliação da resistencia da união composito/dentina ao cisalhamento em dentes deciduos submetidos ao tratamento com hipoclorito de sodioCorrer-Nolasco, Gisele Maria 31 March 2003 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T06:00:37Z (GMT). No. of bitstreams: 1
Correr-Nolasco_GiseleMaria_M.pdf: 5607867 bytes, checksum: bb98da2fe571d84a31f2c91744a11f0a (MD5)
Previous issue date: 2003 / Resumo: O objetivo deste estudo foi avaliar diferentes sistemas de união (Single Bond - SB, Prime & Bond 2.1 - PB e Clearfil SE Bond - CSEB), aplicados à dentina de dentes decíduos, submetida ou não ao tratamento prévio com
hipoclorito de sódio (NaDCI), através da análise da resistência da união ao cisalhamento (RC) e do aspecto morfológico da união compósito/dentina. Foram selecionados 45 molares decíduos hígidos extraídos. As raízes dos dentes foram
seccionadas na junção cemento-esmalte e as coroas ao meio, no sentido mésiodistal. As amostras foram então embutidas com resina de poliestireno em tubos de PV.C., com a superfície vestibular, lingual ou palatina externamente e lixadas até
a obtenção de uma superfície plana em dentina (3 mm de diâmetro). A seguir, foram aleatoriamente distribuídas em 6 grupos (n=15), sendo: G1 - aplicação do sistema SB; G2 - condicionamento ácido (CA), aplicação de NaOCI seguida pelo
sistema SB; G3 - aplicação do sistema PB; G4 - CA, aplicação do NaOCI seguida pelo sistema PB; G5 - aplicação do sistema CSEB e G6 - aplicação de NaOCI, seguida pelo CSEB. Todos os sistemas de união foram aplicados de acordo com
as instruções dos fabricantes. O NaOCI a 10%foi aplicado nos grupos 2,4 (após o condicionamento ácido) e 6 (antes da aplicação do sistema de união) por 60s, e o dente foi lavado por 30s e seco com papel absorvente. Em seguida, o compósito
Filtek Z-250 foi inserido em três incrementos (aproximadamente 2 mm), em uma matriz bipartida de silicone por adição adaptada a um posicionador metálico, e fotoativado por 20s cada incremento. As amostras foram armazenadas em água
destilada a 37°C por 24h e então submetidas ao ensaio de cisalhamento em uma Máquina de Ensaio Universal (Instron - modelo 4411) à velocidade de 0,5mm/min. Os padrões de fratura foram observados em microscópio estereoscópico (aumento 25X), e os representativos de cada grupo foram observados em Microscopia Eletrônica de Varredura (MEV). Para a análise da união compósito/dentina foram utilizados três dentes para cada grupo e repetidos todos os procedimentos
descritos anteriormente. Emseguida, foram seccionados no centro da restauração e preparados para observação em MEV. Os dados obtidos no ensaio de cisalhamento foram submetidos à análise de variância e teste de Tukey (p<0,05).
Os valores obtidos em MPa foram: G1- 3,17 :t 1,97; G2 - 2,93 :t 1,36; G3 - 2,04 :t 0,27; G4 - 1,91 :t 0,74; G5 - 2,67 :t 1,22; G6 -2,14 :t 1,10. De acordo com os resultados, pôde-se observar que houve diferença estatística significativa (p<0,05)
entre os materiais (SB-CSEB-PB). Não houve diferença estatística significativa entre os grupos com ou sem tratamento do substrato, independente do material utilizado (p>0,05). O tipo de falha freqüentemente observada em todos os grupos
foi a falha mista (coesiva no compósito + adesiva). Com relação ao aspecto . morfológico da união, nas amostras sem tratamento do substrato foi observada a presença da camada híbrida e dos prolongamentos resinosos. Nas amostras com
tratamento da superfície (com NaOCI) não foi observada a presença da camada híbrida, porém foram observados prolongamentos resinosos. Pôde-se concluir que o tratamento da superfície com hipoclorito de sódio não afetou a resistência da união compósito/dentina ao cisalhamento, porém, interferiu na formação da camada híbrida, em dentes decíduos / Abstract: The aim of this study was to evaluate different bonding agents (Single Bond - SB, Prime & Bond 2.1 - PB e Clearfil SE Bond - CSEB), in primary teeth treated with sodium hypochlorite (NaOCI) on the shear bond strength (SBS) and
micromorphology of the resin/dentin interface. Forty-five sound extracted primary molars were selected. The roots were sectioned in the enamel-cement junction and the crowns longitudinally, in the mesio-distal sense. The samples were embedded in polystyrene resin with the bucal, lingual or palatine surface externally and they were flattened until dentin surface was reached (3mm in diameter). Then, the samples were randomly assigned in 6 groups (n=15), and received the following
treatments: G1 - SB; G2 - acid etching (AE), 10% NaOCI and the SB; G3 - PB; G4 - AE, 10% NaOCI and the PB; G5 - CSEB; G6 - 10% NaOCI followed by CSEB. Ali the adhesive systems were applied according to manufactures' instructions. The 10% NaOCI solution was applied for 60s in groups 2,4 (after acid etching), and 6 (before adhesive system), washed for 30s and dried with tissue paper. Next, the composite resin was inserted in increments (2mm) in a vinyl polysiloxane impression material matrix, adapted in a metallic holder, and light cured for 20s (each increment). The samples were stored in distilled water at 37°C
for 24h and then, submitted to SBS test in a universal testing machine (Instron - model 4411) with a crosshead speed of 0.5mm/min. The failure sites were observed in stereoscope microscopy of 40X magnification, and the representative
failures of each group were observed in Scanning Electron Microscopy (SEM). The results obtained were submitted to ANOVA and Tukey's tests (p<0.05). The values in MPa were: G1- 3.17 :t 1.97;G2 - 2.93:t 1.36;G3 - 2.04:t 0.27; G4- 1.91 :t
0.74; G5 - 2.67:t 1.2; G6 -2.4:t 1.0. According to the results, it could be noticed that there was a statistical significant difference (p<0.05) among the materiais (SB- CSEB PB). There was no statistical significant difference (p>0.05) among ali
the groups with or without treatment of the substrate, independently of the material used. The mixed fail (cohesive in resin + adhesive) was the one most frequently observed in ali groups. Regarding the interface aspect in specimens without
substrate treatment (NaDCI) it could be observed the presence of the hybrid layer and resin tags whereas treated specimens only resin tags could be observed. It could be concluded that the treatment of the dentin surface with sodium
hypochlorite did not affect the resin/dentin bonding strength but interfered in the hybrid layer formation in primary teeth / Mestrado / Mestre em Materiais Dentários
|
64 |
Avaliação da resistencia a fratura e a fadiga, a seco e em agua, da ceramica in ceram fixadas com agentes de cimentaçãoReges, Rogerio Vieira 03 August 2018 (has links)
Orientador : Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:17:47Z (GMT). No. of bitstreams: 1
Reges_RogerioVieira_M.pdf: 2233963 bytes, checksum: 2c2aad43bb4c45742b0b41d97eb7b03d (MD5)
Previous issue date: 2003 / Mestrado
|
65 |
Avaliação de propriedades fisicas e mecanicas de compositos restauradores odontologicos fotoativados por diferentes metodosObici, Andresa Carla 03 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:18:11Z (GMT). No. of bitstreams: 1
Obici_AndresaCarla_D.pdf: 1154769 bytes, checksum: 4b86e073ca4ca148971be52a0456ec2a (MD5)
Previous issue date: 2003 / Doutorado
|
66 |
Influencia da armazenagem em agua na resistencia a flexão biaxial de porcelana unida a materiais resinosos para fixaçãoGuimarães, Priscilla Santos 18 August 1999 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T05:42:21Z (GMT). No. of bitstreams: 1
Guimaraes_PriscillaSantos_M.pdf: 4440699 bytes, checksum: f24c42055485725bffa0c006ac4cf4e4 (MD5)
Previous issue date: 1999 / Resumo: o propósito deste estudo foi avaliar a influência da armazenagem em água na resistência à flexão de porcelana associada a cimentos a base de resina. Para isso foram confeccionados 120 discos (21 mm de diâmetro X 2mm de espessura) de porcelana feldspática, compostos de duas camadas distintas. A primeira camada formada por porcelana de média fusão (Duceram-Degussa), seguida da aplicação da
porcelana de baixa fusão (Duceram LFC - Degussa) para completar a amostra. Todos os discos cerâmicos foram condicionados com ácido fluorídrico a 10%, durante 4 minutos e divididos em 6 grupos de 20 amostras cada. Em seguida, os materiais resinosos (Scotchbond Resin Cement - 3M, Enforce com flúor - Dentsply) foram manipulados e aplicados de acordo com as instruções dos respectivos fabricantes sobre
a superfície condicionada do disco cerâmico. Sobre o cimento recém-aplicado, foi colocada uma folha de polietileno e uma placa de vidro, e o conjunto disco cerâmico cimento-folha de polietileno e placa de vidro for posicionado em uma prensa hidráulica e comprimido com uma carga de 1500 gramas. Sob compressão o cimento foi fotopolimerizado por 20 segundos em 4 posições diametralmente opostas. Após a
remoção da carga, o cimento foi polimerizado por mais 20 segundos na região central. Os corpos-de-prova assim obtidos foram armazenados em água destilada por períodos de 24h, 3 meses e 6 meses. A seguir os corpos-de-prova foram submetidos ao ensaio de flexão biaxial, a uma velocidade de 1 mm/min, em uma máquina Instron (Modelo 4411). Os valores obtidos foram submetidos a cálculos matemáticos para deteminação da tensão de fratura. Em seguida, estes valores foram submetidos à Distribuição de Weibull, análise de variância e ao teste de Tukey. Os resultados demonstraram que não houve diferença estatisticamente significante (p<O, 01) nos valores de resistência I encontrados para os diferentes períodos de armazenagem. No entanto os grupos onde I utilizou-se o material Enforce, apresentaram valores estatisticamente superiores (p<O,01) àqueles encontrados para os grupos com o material Scotchbond. O Material Enforce I . apresentou maior módulo de Weibull e conseqüentemente, menor probabilidade de
: falha em relação ao material Scotchbond Resin Cement / Abstract: The purpose of this study was to evaluate the influence of water storage on the tensile strength of feldspathic porcelain associated to resin cements. One hundred twenty porcelain discs (21 mm in diameter x 2 mm thick) were fabricated in two different layers. The first one was done of medium fuse porcelain (Duceram - Degussa), followed by the application of a layer of low fusion porcelain (LFC -Degussa). Ali discs were conditioned with 10% fluoridric acid, for 4 minutes and divided in 6 groups of 20 samples each. After, the resin cements (Scotchbond Resin Cement - 3M, Enforce fluoride containing
Dentsply) were manipulated according to manufacturers instructions and, applied over the conditioned surface of the porcelain disco Over it a polyethylene sheet and a glass slab was placed, and the assembly was taken to a hydraulic press and squeezed with a load of 1500 g. Under compression cement was photopolimerized for 20 seconds in 4 different positions. After the removal of the load, the cement was photopolimerized for 20 seconds on the middle of the disco The samples were then stored in distilled water for 24 hours, 3 and 6 months. The biaxial flexure test was conducted in a universal test méilchine
(Instron - model 4411), at a cross speed of 1 mm/min. The data was then submitted to Tukey's test and Weibull Distribution. From the results, there was no statistic difference (p<0.01) on the strength values for the different periods of storage in water. However the strength values for groups with Enforce was statistically higher (p<0.01) than those for Scotchbond Resin Cement. The material Enforce showed a higher Weibull modulus and lower probability of failure in comparison with Scotchbond Resin Cement / Mestrado / Materiais Dentarios / Mestre em Ciências
|
67 |
Avaliação do efeito do polimento quimico sobre algumas propriedades fisico quimicas das resinas acrilicas ativadas quimica e termicamenteBraun, Katia Olmedo 13 September 1999 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T11:05:35Z (GMT). No. of bitstreams: 1
Braun_KatiaOlmedo_D.pdf: 4956224 bytes, checksum: 08e169d63e08d6d20fe8eb879fa0237a (MD5)
Previous issue date: 1999 / Resumo: Este estudo avaliou o efeito do polimento químico sobre a liberação de monômero residual, dureza superficial, resistência transversa e a textura de superfície de resinas auto e termopolimerizáveis, comparando-o com o polimento mecânico. As amostras foram confeccionadas em resinas termopolimerizável Clássico e autopolimerizável JET -Clássico e divididas em 4 grupos: G1- resina autopolimerizável com polimento mecânico; G2 - resina autopolimerizável com polimento químico; G3 - resina termopolimerizável com polimento mecânico; G4resina termopolimerizável com polimento químico. Após os polimentos recebidos as amostras foram imersas em água destilada à temperatura de 37°C e as avaliações executadas nos períodos de 1, 2, 8 e 32 dias. A liberação do monômero foi realizada em espectrofotômetro BEKMAN OU 65; a dureza Knoop foi medida com microdurômetro SHIMAOZU HMV 2000; a resistência transversa por três pontos em uma máquina de ensaio universal EMIC OL 500, seguindo a especificação n° 12 da AOA. Os resultados foram submetidos a ANOVA (p=5%) sendo as médias do monôn:tero residual e dureza Knoop comparadas com o teste de comparação de médias não paramétrico e as de resistência transversa com o teste t ao nível de significância de 5%. Concluiu-se que: - o polimento químico aumentou a quantidade de monômero residual e reduziu os valores de dureza superficial das duas resinas de maneira significativa em todos os períodos estudados; O polimento químico não interferiu na resistência transversa da resina auto e' termopolimerizável. Na avaliação feita com MEV verificou-se que o polimento químico altera a camada superficial das duas resinas promovendo um aspecto ondulado semelhante / Abstract: Although chemical polishing of dental acrylic resins have became a very used alternative, very litlle is known about tt:1e effect on the properties of acrylic resin. This study evaluated the effect of this polishing on the residual monomer release in the water, microhardness, transverse resistence and surface texture of heat and a could curing resins, comparing the results obtained with mechanical polishing. The specimens were made and divided into 4 groups: G1- Self-curing resins with mechanical polishing; G2- Self-curing resins with chemical polishing; G3- Heat-curing resins with mechanical polishing; G4- Heat-curing resins with chemical polishing. Afier having undergone to polishing the specimens were imerse on destiled water 37°C and the evaluations were made in 1, 2, 8 and 32 days. Monomers released in the water was evaluated with espectrophotometricaly; the Knoop micro-hardness was measured with Shimadzu a micro-hardness teste r ; the transverse resistance was measured by three points in a EMIC DL a universal machine, following ADA specification n° 12 . According to statistical analysis, it was concluded that : - chemical polishing have significantly increased the amount of residual monomers of' both resins in ali periods of time studied and have reduced the superficial hardness of them ali periods; chemical polishing had not interfered on transverse resistance of self-curing and of heat-curing resin. Through evaluation whit SEM it was checked that chemical polishing altered the superficial layer of both resins, promoting a wavy formo / Doutorado / Protese / Doutor em Clínica Odontológica
|
68 |
Comportamento de argamassas com emprego de po de borrachaMeneguini, Eduardo Cesar Antonelli 03 August 2018 (has links)
Orientador : Vladimir Antonio Paulon / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T14:46:52Z (GMT). No. of bitstreams: 1
Meneguini_EduardoCesarAntonelli_M.pdf: 2589096 bytes, checksum: c0014d86359665da673ab2bce777ebc9 (MD5)
Previous issue date: 2003 / Mestrado
|
69 |
Relação entre a tensão e a resistencia mecanica de fibras opticasPinto, Fernando Antonio 07 November 1990 (has links)
Orientador: Ricardo Enrique Medrano / Tese (doutorado) - Universidade Estadualde Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-13T22:00:12Z (GMT). No. of bitstreams: 1
Pinto_FernandoAntonio_D.pdf: 7503410 bytes, checksum: 48ef26f7db2bfb54f76294548d1750bb (MD5)
Previous issue date: 1990 / Resumo: As fibras opticas empregadas na confecção de cabos ópticos são submetidas ao teste de tensão contínua (T.T.C.) durante a fabricação, a fim de eliminar fibras fracas e garantir alguma resistência mecânica e tempo de vida minimos. Quanto as fibras são tensionadas num certo nível de tensão, aqueles que sobrevivem não podem ser tensionadas no mesmo nível sem que algumas delas fratura, devido ao dano mecânico introduzido pelo teste. Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: When optical fibers are employed in the manufacturing of optical fiber cables, they are previously submitted to the proof-testing to eliminate weak fibers and to garantee some minimum strenght and lifetime. The fibers are stressed to some level and the surviving fibers cannot be stressed to the same level without some of them fracture because the mechanical damage introduced by the test. Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Mecânica
|
70 |
Propagação da trinca por fadiga em chapas finas de liga de aluminio de alta resistencia sob carregamentos de amplitude variavelVoorwald, Herman Jacobus Cornelis 20 April 1988 (has links)
Orientador: Ana Maria Martinez Nazar / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T13:24:55Z (GMT). No. of bitstreams: 1
Voorwald_HermanJacobusCornelis_D.pdf: 7396565 bytes, checksum: f3ef34e6746c13a441c84378ba3f3270 (MD5)
Previous issue date: 1988 / Resumo: O objetivo do presente trabalho foi o de estudar os principais efeitos de interação na taxa de propagação de uma trinca por fadiga, em amostras de uma liga de alumínio 2024-T3 de espessura fina, submetida a carregamentos de amplitude variável. Os efeitos de interação estudados foram os seguintes: 1. Aceleração na taxa de propagação da trinca por fadiga em carregamentos de seqüência ascendente. 2. Retardo na taxa de propagação da trinca por fadiga em carregamentos de seqüência descendente. 3. O efeito de cargas de tração de valor menor do que as anteriores, na redução do retardo no crescimento da trinca, Na elaboração dos modelos teóricos foram utilizados a equação de Forman, que representa bem os dados empíricos obtidos em carregamentos de amplitude constante e o modelo de Willenborg. Com os resultados obtidos foi possível obter um modelo geral que pode representar o crescimento de uma trinca por fadiga submetida a um carregamento de amplitude variável / Abstract: This thesis has the objective of studyng the interaction effects on the fatigue crack propagation rate in thin samples of an aluminium alloy 2024-T3, subjected to variable amplitude loading. The following interaction effects were studied: 1. Acceleration on the fatigue crack propagation rate in ascendent sequence loading. 2. Retardation effects on the fatigue crack propagation rate in descendent sequence loading. 3. The effect of underloads on the retardation of the fatigue crack growth. To obtain the theoretical models that represent the interaction effects, the Forman expression and the Willenborg model were employed. It was possible, with those results, to elaborate a final model that represents the growth of a fatigue crack subjected to variable amplitude loading / Doutorado / Doutor em Engenharia Mecânica
|
Page generated in 0.1214 seconds