1

Comparação dos ensaios de resistência adesiva por torção e por cisalhamento com fio / A comparison between torsion and wire-loop shear bond strength tests

Xavier, Tathy Aparecida 24 March 2010 (has links)
Objetivo: verificar, através de análise por elementos finitos e de uma etapa experimental, se o ensaio de torção, como ensaio de resistência de interfaces adesivas, seria capaz de levar os espécimes à ruptura sob tensões de cisalhamento e se ele seria vantajoso em relação ao ensaio de cisalhamento. Material e Método: para a análise de tensões pelo método dos elementos finitos, os modelos tridimensionais dos dois ensaios foram constituídos por cilindro de compósito, uma camada de adesivo e um cilindro de dentina com maior diâmetro. Os espécimes foram simulados nos tamanhos convencional e micro, numa proporção de 5:1, exceto pela camada de adesivo, de espessura constante. Foram simulados dois módulos de elasticidade do cilindro de compósito (híbrido e baixa viscosidade) e, para os modelos de cisalhamento, variaram as distâncias entre o local de carregamento e a interface adesiva. Foram analisados os valores das tensões máxima principal e cisalhamento máximo e a proporção entre elas ao longo da interface dentina/adesivo; a direção dos vetores de tensão máxima principal; e o local dos picos de tensão. Na etapa experimental, foram construídos cilindros de compósito (híbrido e de baixa viscosidade) nos tamanhos convencional e micro, aderidos a uma superfície de dentina bovina por meio de três sistemas adesivos. O esforço de cisalhamento foi aplicado com fio ortodôntico a uma distância da interface adesiva baseada na literatura e, para os ensaios de torção e microtorção, foram desenvolvidos dispositivos específicos para a aplicação do torque. Os resultados de tensão de ruptura foram submetidos à análise de variância e teste de Tukey. Todas as superfícies de fratura foram analisadas por meio de microscopia eletrônica de varredura. As frequências das fraturas adesivas e coesivas foram submetidas ao teste exato de Fisher e relacionadas aos valores de tensão de ruptura experimentais, bem como suas características foram relacionadas às tensões observadas pelo método dos elementos finitos. Os parâmetros experimentais de comparação entre os ensaios foram: poder de detecção de diferenças significantes entre os sistemas adesivos; constância da classificação relativa dos mesmos ao alterar as configurações dos ensaios e frequências dos tipos de fratura. Resultados: ambos os ensaios apresentaram um estado complexo de tensões com distribuição nãouniforme. Não foi notada menor sensibilidade dos resultados do ensaio de torção às mudanças das configurações do teste, nem uma maior capacidade para detectar diferenças significantes entre os adesivos do que o ensaio de cisalhamento. O ensaio de torção apresentou maior dificuldade de execução prática e maiores frequências de fraturas coesivas, porém, estas ocorreram mais no cilindro de compósito, enquanto no cisalhamento, ocorreram mais na dentina. Não houve certeza sobre o tipo de tensão que tenha levado à fratura nos dois tipos de ensaio. Conclusões: embora não se tenha certeza se o ensaio de torção leva à ruptura sob tensões de cisalhamento e tenham sido notadas desvantagens práticas de execução do ensaio, este apresenta uma característica que sugere novos estudos: ocorrência de fraturas coesivas principalmente no cilindro de compósito, o que poderia, talvez, ser resolvido com o reforço do material do cilindro. / Objective: verify, by finite element analysis (FEA) and laboratorial tests, if the torsion bond strength test is able to lead adhesive interface to fracture under shear stress and if it would be more advantageous than wire-loop shear test. Material and method: for stress analysis by finite element method, the 3D models of both tests consisted of a resin composite cylinder, an adhesive layer and a dentin cylinder with a larger diameter. The specimens were simulated with both conventional and micro sizes, in a 5:1 ratio, except for the adhesive layer, kept in a constant thickness. Two values of elastic modulus were simulated for the composite cylinder (hybrid and flowable). For the shear models, different distances were simulated between the load point and the adhesive interface. The values of maximum principal and maximum shear stresses and the ratio between both types were analyzed along the adhesive interface, as well as the maximum principal vectors direction and the local of stress peaks. For the laboratorial tests, cylinders of hybrid and flowable resin composite, in both micro and conventional sizes, were adhered onto dentin surfaces by means of 3 adhesive systems. The shear load was applied with a metallic wire-loop at distances from the interface based on literature and, for the torsion test, the torque was applied by specific apparatus developed for that. The values of bond strength were submitted to analysis of variance and Tukeys test. Fracture surfaces were analyzed by scan electron microscopy. The frequencies of fracture types were compared by Fishers test and its relationship with bond strength values were verified, as well as the relationship between fracture features and stresses results obtained by FEA. The experimental parameters for comparison between both tests were: ability for detecting significant differences among the 3 adhesives, change of adhesives ranking while varying the test configuration and frequency of fracture types. Results: both tests showed non-uniform stress distribution. It was not noticed a lower sensibility of torsion test results to changes of the test configurations, nor a major ability for detecting significant differences among the adhesive systems than showed the shear test. The torsion test showed to be more difficult to execute and exhibited a higher frequency of cohesive fracture, however, that occurred most of the time in the composite cylinder, while it occurred mainly in dentin in shear test. There was no certainty about the kind of stress that lead to specimen fracture in both tests. Conclusions: although there was no certainty about the kind of stress that lead to specimen fracture and the major difficulty of execution of torsion test, this test exhibited a feature that suggests future studies: the occurrence of cohesive fracture mainly in the composite cylinder, which could be solved, maybe, by reinforcing the cylinder material.
2

Comparação dos ensaios de resistência adesiva por torção e por cisalhamento com fio / A comparison between torsion and wire-loop shear bond strength tests

Tathy Aparecida Xavier 24 March 2010 (has links)
Objetivo: verificar, através de análise por elementos finitos e de uma etapa experimental, se o ensaio de torção, como ensaio de resistência de interfaces adesivas, seria capaz de levar os espécimes à ruptura sob tensões de cisalhamento e se ele seria vantajoso em relação ao ensaio de cisalhamento. Material e Método: para a análise de tensões pelo método dos elementos finitos, os modelos tridimensionais dos dois ensaios foram constituídos por cilindro de compósito, uma camada de adesivo e um cilindro de dentina com maior diâmetro. Os espécimes foram simulados nos tamanhos convencional e micro, numa proporção de 5:1, exceto pela camada de adesivo, de espessura constante. Foram simulados dois módulos de elasticidade do cilindro de compósito (híbrido e baixa viscosidade) e, para os modelos de cisalhamento, variaram as distâncias entre o local de carregamento e a interface adesiva. Foram analisados os valores das tensões máxima principal e cisalhamento máximo e a proporção entre elas ao longo da interface dentina/adesivo; a direção dos vetores de tensão máxima principal; e o local dos picos de tensão. Na etapa experimental, foram construídos cilindros de compósito (híbrido e de baixa viscosidade) nos tamanhos convencional e micro, aderidos a uma superfície de dentina bovina por meio de três sistemas adesivos. O esforço de cisalhamento foi aplicado com fio ortodôntico a uma distância da interface adesiva baseada na literatura e, para os ensaios de torção e microtorção, foram desenvolvidos dispositivos específicos para a aplicação do torque. Os resultados de tensão de ruptura foram submetidos à análise de variância e teste de Tukey. Todas as superfícies de fratura foram analisadas por meio de microscopia eletrônica de varredura. As frequências das fraturas adesivas e coesivas foram submetidas ao teste exato de Fisher e relacionadas aos valores de tensão de ruptura experimentais, bem como suas características foram relacionadas às tensões observadas pelo método dos elementos finitos. Os parâmetros experimentais de comparação entre os ensaios foram: poder de detecção de diferenças significantes entre os sistemas adesivos; constância da classificação relativa dos mesmos ao alterar as configurações dos ensaios e frequências dos tipos de fratura. Resultados: ambos os ensaios apresentaram um estado complexo de tensões com distribuição nãouniforme. Não foi notada menor sensibilidade dos resultados do ensaio de torção às mudanças das configurações do teste, nem uma maior capacidade para detectar diferenças significantes entre os adesivos do que o ensaio de cisalhamento. O ensaio de torção apresentou maior dificuldade de execução prática e maiores frequências de fraturas coesivas, porém, estas ocorreram mais no cilindro de compósito, enquanto no cisalhamento, ocorreram mais na dentina. Não houve certeza sobre o tipo de tensão que tenha levado à fratura nos dois tipos de ensaio. Conclusões: embora não se tenha certeza se o ensaio de torção leva à ruptura sob tensões de cisalhamento e tenham sido notadas desvantagens práticas de execução do ensaio, este apresenta uma característica que sugere novos estudos: ocorrência de fraturas coesivas principalmente no cilindro de compósito, o que poderia, talvez, ser resolvido com o reforço do material do cilindro. / Objective: verify, by finite element analysis (FEA) and laboratorial tests, if the torsion bond strength test is able to lead adhesive interface to fracture under shear stress and if it would be more advantageous than wire-loop shear test. Material and method: for stress analysis by finite element method, the 3D models of both tests consisted of a resin composite cylinder, an adhesive layer and a dentin cylinder with a larger diameter. The specimens were simulated with both conventional and micro sizes, in a 5:1 ratio, except for the adhesive layer, kept in a constant thickness. Two values of elastic modulus were simulated for the composite cylinder (hybrid and flowable). For the shear models, different distances were simulated between the load point and the adhesive interface. The values of maximum principal and maximum shear stresses and the ratio between both types were analyzed along the adhesive interface, as well as the maximum principal vectors direction and the local of stress peaks. For the laboratorial tests, cylinders of hybrid and flowable resin composite, in both micro and conventional sizes, were adhered onto dentin surfaces by means of 3 adhesive systems. The shear load was applied with a metallic wire-loop at distances from the interface based on literature and, for the torsion test, the torque was applied by specific apparatus developed for that. The values of bond strength were submitted to analysis of variance and Tukeys test. Fracture surfaces were analyzed by scan electron microscopy. The frequencies of fracture types were compared by Fishers test and its relationship with bond strength values were verified, as well as the relationship between fracture features and stresses results obtained by FEA. The experimental parameters for comparison between both tests were: ability for detecting significant differences among the 3 adhesives, change of adhesives ranking while varying the test configuration and frequency of fracture types. Results: both tests showed non-uniform stress distribution. It was not noticed a lower sensibility of torsion test results to changes of the test configurations, nor a major ability for detecting significant differences among the adhesive systems than showed the shear test. The torsion test showed to be more difficult to execute and exhibited a higher frequency of cohesive fracture, however, that occurred most of the time in the composite cylinder, while it occurred mainly in dentin in shear test. There was no certainty about the kind of stress that lead to specimen fracture in both tests. Conclusions: although there was no certainty about the kind of stress that lead to specimen fracture and the major difficulty of execution of torsion test, this test exhibited a feature that suggests future studies: the occurrence of cohesive fracture mainly in the composite cylinder, which could be solved, maybe, by reinforcing the cylinder material.
3

Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placement

Quinto Junior, José 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.
4

Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placement

José Quinto Junior 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.