• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validação do ensaio TRT para estudo paramétrico da troca de calor de uma estaca de energia em um solo tropical

Castillo Orozco, Henry 17 February 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016. / Os sistemas trocadores de calor acoplados ao solo têm sido usados por anos como sistemas de aclimatização de prédios residenciais e comerciais. Estes sistemas foram adaptados para estruturas de fundação com o fim de trocar energia térmica com o solo. Atualmente, estacas de energia são implementadas em muitos países para substituir parte da energia elétrica e outros tipos de fontes de energia. O Brasil é o nono consumidor de energia elétrica em todo o mundo, onde muita dessa energia é utilizada para o uso de acondicionamento climático. Por esta razão pesquisas relacionadas com estacas de energia no Brasil são estimuladas com o fim de reduzir o consumo de energia elétrica. Testes de resposta térmica têm sido realizados em uma estaca de energia instalada no campo experimental da Universidade de São Paulo na região subtropical de São Carlos. Simultaneamente, se realizaram simulações de sistemas de estaca de energia com propriedades térmicas obtidas durante o ensaio para avaliar o desempenho da troca de calor dos sistemas na região. Para a análise numérica, são avaliados os efeitos térmicos devido à variação em propriedades térmicas do solo e concreto, geometria da estaca, vazão, posição do nível freático de água, espessura da tubulação e temperatura média de entrada. Adicionalmente, se determina o espaçamento ótimo entre estacas para permitir o melhor desempenho das estacas. Em este documento se apresentam resultados e análises de modelos simulados no software COMSOL, utilizando os módulos Heat Transfer e Non-Isothermal Pipe Flow, e com eles, obtendo assim a configuração ótima de trabalho. Foi observada a melhora do comportamento térmico da estaca com o acrescimento dos valores em parâmetros geométricos, o número de tubulações e da vazão em condições de fluxo turbulento. Parâmetros como a espessura da tubulação e condutividade térmica do solo e concreto proporcionam aportes energéticos não muito significativos no resultado da troca de calor da estaca estudada. / Ground-Coupled Heat Exchanger Systems has been used as acclimatization system for residential and commercial buildings. This system was adapted to pile foundations in order to exchange thermal energy with the ground. Currently, this foundation system has been implemented in many countries to replace an important part of electrical and other sources of energy. Brazil is the ninth largest consumer of electrical energy in the world, and much of this energy is used for air conditioning. For this reason, researchers in Brazil are investigating the use of energy piles in order to reduce the consumption of electricity. Thermal response tests have been carried out on a heat exchanger pile at the geotechnical experimental site of the University of São Paulo in São Carlos city, region of subtropical climate. Simultaneously, using the thermal properties obtained in these tests, numerical analysis has been performed to investigate the heat exchange performance of energy piles installed in this site in São Carlos. For this numerical analysis, the effect of variations due to soil and concrete properties, pile geometry, groundwater level, pipe thickness and the flow rate on the pile thermal response were evaluated. Additionally, is determined the optimal space between piles that allows a better performance of each pile. The current paper presents the results obtained by the analysis models simulated to found an optimal configuration of an energy pile through the software COMSOL, using Heat Transfer and Non-Isothermal Pipe Flow modules. From this work, it was observed that the optimal configuration was obtained for a turbulent flow condition in piles with greater length and diameter. The effects of thickness in pipe, the thermal conductivity of the surrounding soil and concrete were not very influential on the thermal performance of the heat exchanger pile.
2

Estudo experimental da resposta térmica de fundações por estacas trocadoras de calor em solo não saturado / An experimental study of the thermal response of heat exchanger piles in unsaturated tropical soil

Bandeira Neto, Luis Antonio 08 December 2015 (has links)
O estudo experimental apresentado nesta dissertação foi realizado para avaliar a resposta térmica de fundações por estacas trocadoras de calor, que podem ser usadas para reduzir o elevado consumo de energia em sistemas de condicionamento de ar no Brasil. A principal motivação para a produção deste trabalho foi a ausência de estudos sobre o desempenho térmico de estacas e/ou furos trocadores de calor em solo tropical, que é muito comum em nosso país. Para esta pesquisa, cinco ensaios de resposta térmica (TRT) foram realizados no Campo Experimental de Fundações da Universidade de São Paulo em São Carlos/SP, Brasil. A camada de solo superficial deste terreno consiste de solo tropical não saturado, composto de areia argilosa coluvial (laterítico) sobre um solo residual de arenito (saprolito). O ensaio in situ denominado TRT é o método experimental mais comum para a determinação das propriedades térmicas de sistemas de fundações por estacas trocadoras de calor. Os experimentos foram realizados em duas estacas escavadas, com 12 m de profundidade, equipadas com tubos trocadores de calor, instaladas em uma camada de solo com temperatura média em torno de 24°C. O principal objetivo deste trabalho foi avaliar a performance de estacas trocadoras de calor na condição de solo e clima investigados (alta temperatura do solo, solo laterítico não saturado com alta porosidade próximo a superfície). Também foram verificados os efeitos da posição do nível d\'água, da vazão da água circulante na estaca, e da duração do ensaio nas propriedades térmicas das estacas trocadora de calor avaliadas. Os resultados encontrados da taxa de troca de calor por metro de estaca neste estudo variam 79 a 110 W/m, portanto, estas estacas mostram bom potencial de transferência de calor no local investigado. Os resultados desse estudo fornece informações úteis para a avaliação da eficiência de estacas trocadoras de calor como um sistema de refrigeração em regiões tropicais e subtropicais brasileiras. / Brazil is the fifth largest buyer of air conditioner in the world because of its tropical and subtropical climate. To address this problem, the current experimental study was carried out to evaluate the thermal response of energy piles that can be used to reduce the high energy consumption in cooling systems in Brazil. The key factor that motivates this study is that unsaturated tropical soils cover a significant part of the Brazilian territory, and the thermal performance of heat exchanger piles in typical Brazilian soil and climate has not been investigated before. Five Thermal Response tests (TRT) were conducted for this research in the Geotechnical research field of the University of São Paulo at São Carlos/SP, Brazil, of unsaturated tropical soil, including a superficial layer composed of colluvial clayey sand (lateritic) overlaying in a residual sandstone soil (saprolitic). Thermal response tests are the most common experimental method for determining thermal properties of the energy foundation systems. The tests were performed on two drilled piles of 12m length equipped with heat transfer pipes, installed a soil layer with average temperature of 24°C. The main objective of this work was to obtain some data about the thermal energy delivery of energy piles in the soil and climate condition investigated herein (high ground temperature, unsaturated and tropical soil with high porosity). The effects of ground water table, flow rate, duration of test, and number of heat exchanger U-pipes on the thermal properties of the energy pile were also evaluated in this study. The thermal parameters obtained allowed a first evaluation about the thermal efficiency of the piles in the particular soil. The results of heat exchange rate found in this study vary from 79 to 110 W/m, therefore energy piles installed in the investigated site show good heat transfer potential. This study provides interesting information to the evaluation of heat exchange efficiency in energy foundations to be used as a cooling system in tropical and subtropical Brazilian regions.
3

Estudo experimental da resposta térmica de fundações por estacas trocadoras de calor em solo não saturado / An experimental study of the thermal response of heat exchanger piles in unsaturated tropical soil

Luis Antonio Bandeira Neto 08 December 2015 (has links)
O estudo experimental apresentado nesta dissertação foi realizado para avaliar a resposta térmica de fundações por estacas trocadoras de calor, que podem ser usadas para reduzir o elevado consumo de energia em sistemas de condicionamento de ar no Brasil. A principal motivação para a produção deste trabalho foi a ausência de estudos sobre o desempenho térmico de estacas e/ou furos trocadores de calor em solo tropical, que é muito comum em nosso país. Para esta pesquisa, cinco ensaios de resposta térmica (TRT) foram realizados no Campo Experimental de Fundações da Universidade de São Paulo em São Carlos/SP, Brasil. A camada de solo superficial deste terreno consiste de solo tropical não saturado, composto de areia argilosa coluvial (laterítico) sobre um solo residual de arenito (saprolito). O ensaio in situ denominado TRT é o método experimental mais comum para a determinação das propriedades térmicas de sistemas de fundações por estacas trocadoras de calor. Os experimentos foram realizados em duas estacas escavadas, com 12 m de profundidade, equipadas com tubos trocadores de calor, instaladas em uma camada de solo com temperatura média em torno de 24°C. O principal objetivo deste trabalho foi avaliar a performance de estacas trocadoras de calor na condição de solo e clima investigados (alta temperatura do solo, solo laterítico não saturado com alta porosidade próximo a superfície). Também foram verificados os efeitos da posição do nível d\'água, da vazão da água circulante na estaca, e da duração do ensaio nas propriedades térmicas das estacas trocadora de calor avaliadas. Os resultados encontrados da taxa de troca de calor por metro de estaca neste estudo variam 79 a 110 W/m, portanto, estas estacas mostram bom potencial de transferência de calor no local investigado. Os resultados desse estudo fornece informações úteis para a avaliação da eficiência de estacas trocadoras de calor como um sistema de refrigeração em regiões tropicais e subtropicais brasileiras. / Brazil is the fifth largest buyer of air conditioner in the world because of its tropical and subtropical climate. To address this problem, the current experimental study was carried out to evaluate the thermal response of energy piles that can be used to reduce the high energy consumption in cooling systems in Brazil. The key factor that motivates this study is that unsaturated tropical soils cover a significant part of the Brazilian territory, and the thermal performance of heat exchanger piles in typical Brazilian soil and climate has not been investigated before. Five Thermal Response tests (TRT) were conducted for this research in the Geotechnical research field of the University of São Paulo at São Carlos/SP, Brazil, of unsaturated tropical soil, including a superficial layer composed of colluvial clayey sand (lateritic) overlaying in a residual sandstone soil (saprolitic). Thermal response tests are the most common experimental method for determining thermal properties of the energy foundation systems. The tests were performed on two drilled piles of 12m length equipped with heat transfer pipes, installed a soil layer with average temperature of 24°C. The main objective of this work was to obtain some data about the thermal energy delivery of energy piles in the soil and climate condition investigated herein (high ground temperature, unsaturated and tropical soil with high porosity). The effects of ground water table, flow rate, duration of test, and number of heat exchanger U-pipes on the thermal properties of the energy pile were also evaluated in this study. The thermal parameters obtained allowed a first evaluation about the thermal efficiency of the piles in the particular soil. The results of heat exchange rate found in this study vary from 79 to 110 W/m, therefore energy piles installed in the investigated site show good heat transfer potential. This study provides interesting information to the evaluation of heat exchange efficiency in energy foundations to be used as a cooling system in tropical and subtropical Brazilian regions.

Page generated in 0.0719 seconds