• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

From nanoscale to macroscale using the atomic force microscope to quantify the role of few-asperity contacts in adhesion

Thoreson, Erik J. January 2006 (has links)
Dissertation (Ph.D.)--Worcester Polytechnic Institute. / Keywords: Surface roughness; Surface forces; Van der Waals forces. Includes bibliographical references.
2

Avaliação da alteração de rugosidade de superfície e dispersão de íons de ligas metálicas odontológicas submetidas a ensaio de tribocorrosão experimental / Evaluation of changes in surface roughness and ion release from dental casting alloys after an experimental tribocorrosion process

Pupim, Denise 14 January 2016 (has links)
Este estudo teve como objetivo avaliar a alteração da rugosidade superficial e a dispersão de íons para o meio após tribocorrosão experimental das ligas CoCrMo, NiCr e NiCrTi, comercialmente utilizadas na fabricação de próteses odontológicas, utilizando solução de saliva artificial (Fusayama) como eletrólito com valores de pH 3,0; 6,5 e 9,0. Foram fundidas 15 amostras de cada liga (&Oslash;13x2mm) por chama e 15 por máquina de fundição com atmosfera inerte de argônio, sendo cinco amostras para cada pH analisado. A tribocorrosão experimental foi realizada na configuração esfera sobre superfície, utilizando esfera de zircônia (&Oslash;10mm), em equipamento de ciclagem vertical, simulando o movimento do ciclo mastigatório, com aplicação de 5N de carga e monitoramento do potencial de circuito aberto (OCP). O sistema operou a velocidade de 60 ciclos por minuto, totalizando 7500 ciclos após 15 minutos de ensaio, equivalente ao tempo de contato dental diário. Foi utilizada saliva artificial de pH 3,0; 6,5 e 9,0 e leituras de rugosidade de superfície foram realizadas antes e após os ensaios de tribocorrosão experimental em microscópio confocal a laser. A saliva utilizada foi armazenada em tubos de Falcon DNA-free e submetida à quantificação da dispersão de íons metálicos para a solução, por meio de análise de ICP-MS. O comportamento das ligas em contato com a esfera de zircônia durante o ensaio de tribocorrosão experimental realizado em potencial de circuito aberto foi alterado em função do pH do meio (P<0,001) e da técnica de fundição utilizada (P<0,001). Todas as amostras apresentaram tendência à repassivação após a remoção do contato com a esfera, indicando formação de novo filme protetor na superfície da liga. A liberação de íons foi maior nas amostras fundidas por chama e em contato com pH 3,0 (ácido), sendo o analito níquel liberado em maior concentração (P=0,010). Entretanto, os valores encontrados estão abaixo dos limites indicados como causadores de citotoxicidade e alterações celulares. Os resultados indicam que as amostras fundidas por chama apresentaram rugosidade de superfície estatisticamente maior que as fundidas por plasma (P=0,042), sendo observado nessas amostras a presença de defeitos na superfície e possíveis falhas de fundição que favorecem o processo corrosivo. O pH da saliva e a técnica de fundição exerceram influência sobre o comportamento de repassivação das ligas, rugosidade de superfície e quantidade de íons liberada para o meio, sendo os melhores resultados encontrados quando a técnica de fundição por plasma foi utilizada. / The aim of this study was to evaluate the changes in surface roughness and ions release to the environment after experimental tribocorrosion of CoCrMo, NiCr and NiCrTi alloys, commercially applied in dental prosthesis, using artificial saliva solution (Fusayama) as electrolyte with different levels of pH (3.0; 6.5 and 9.0). Fifteen samples were casted by flame from each alloy (&Oslash;13x2mm) and 15 by plasma in a casting machine with an inert atmosphere (argon), five samples for each pH analyzed. The experimental tribocorrosion was performed in a ball-on-flat configuration, using a zirconia ball (&Oslash;10mm) in vertical cycling equipment, simulating the masticatory cycle movement, applying 5N of load and recording the open circuit potential (OCP). The system operated at 60 cycles per minute, a total of 7500 cycles after 15 minutes, corresponding to the daily tooth contact. Artificial saliva at pH 3.0; 6.5 and 9.0 was used and surface roughness measurements were performed before and after the experimental tribocorrosion tests in a laser confocal microscope. After the tests, the saliva was stored in a DNA-free Falcon tubes and subjected to measurement of the ion release to the solution by means of ICP-MS analysis. The behavior of the alloys in contact with the zirconia ball during the experimental tribocorrosion performed in open circuit potential changed according to the pH (P<0.001) and the casting technique (P<0.001). All samples trended to repassivate when the ball contact was removed, indicating new formation of the protective film on alloy surface. The ion release was higher in the samples casted by flame and in contact with pH 3.0 (acid), nickel analyte being released in a higher concentration (P=0.010). However, the values found are below the limits specified to induce cytotoxicity and cellular changes. The results reflected that the samples casted by flame presented surface roughness statistically greater than those casted by plasma (P=0.042) and it was observed in these samples the presence of surface defects and possible casting flaws that enhance the corrosion process. The pH of the saliva and the casting technique presented influence on the repassivation behavior of the alloys, surface roughness and quantity of ions released into the environment, where the best results were found when the plasma casting technique was used.
3

Avaliação da alteração de rugosidade de superfície e dispersão de íons de ligas metálicas odontológicas submetidas a ensaio de tribocorrosão experimental / Evaluation of changes in surface roughness and ion release from dental casting alloys after an experimental tribocorrosion process

Denise Pupim 14 January 2016 (has links)
Este estudo teve como objetivo avaliar a alteração da rugosidade superficial e a dispersão de íons para o meio após tribocorrosão experimental das ligas CoCrMo, NiCr e NiCrTi, comercialmente utilizadas na fabricação de próteses odontológicas, utilizando solução de saliva artificial (Fusayama) como eletrólito com valores de pH 3,0; 6,5 e 9,0. Foram fundidas 15 amostras de cada liga (&Oslash;13x2mm) por chama e 15 por máquina de fundição com atmosfera inerte de argônio, sendo cinco amostras para cada pH analisado. A tribocorrosão experimental foi realizada na configuração esfera sobre superfície, utilizando esfera de zircônia (&Oslash;10mm), em equipamento de ciclagem vertical, simulando o movimento do ciclo mastigatório, com aplicação de 5N de carga e monitoramento do potencial de circuito aberto (OCP). O sistema operou a velocidade de 60 ciclos por minuto, totalizando 7500 ciclos após 15 minutos de ensaio, equivalente ao tempo de contato dental diário. Foi utilizada saliva artificial de pH 3,0; 6,5 e 9,0 e leituras de rugosidade de superfície foram realizadas antes e após os ensaios de tribocorrosão experimental em microscópio confocal a laser. A saliva utilizada foi armazenada em tubos de Falcon DNA-free e submetida à quantificação da dispersão de íons metálicos para a solução, por meio de análise de ICP-MS. O comportamento das ligas em contato com a esfera de zircônia durante o ensaio de tribocorrosão experimental realizado em potencial de circuito aberto foi alterado em função do pH do meio (P<0,001) e da técnica de fundição utilizada (P<0,001). Todas as amostras apresentaram tendência à repassivação após a remoção do contato com a esfera, indicando formação de novo filme protetor na superfície da liga. A liberação de íons foi maior nas amostras fundidas por chama e em contato com pH 3,0 (ácido), sendo o analito níquel liberado em maior concentração (P=0,010). Entretanto, os valores encontrados estão abaixo dos limites indicados como causadores de citotoxicidade e alterações celulares. Os resultados indicam que as amostras fundidas por chama apresentaram rugosidade de superfície estatisticamente maior que as fundidas por plasma (P=0,042), sendo observado nessas amostras a presença de defeitos na superfície e possíveis falhas de fundição que favorecem o processo corrosivo. O pH da saliva e a técnica de fundição exerceram influência sobre o comportamento de repassivação das ligas, rugosidade de superfície e quantidade de íons liberada para o meio, sendo os melhores resultados encontrados quando a técnica de fundição por plasma foi utilizada. / The aim of this study was to evaluate the changes in surface roughness and ions release to the environment after experimental tribocorrosion of CoCrMo, NiCr and NiCrTi alloys, commercially applied in dental prosthesis, using artificial saliva solution (Fusayama) as electrolyte with different levels of pH (3.0; 6.5 and 9.0). Fifteen samples were casted by flame from each alloy (&Oslash;13x2mm) and 15 by plasma in a casting machine with an inert atmosphere (argon), five samples for each pH analyzed. The experimental tribocorrosion was performed in a ball-on-flat configuration, using a zirconia ball (&Oslash;10mm) in vertical cycling equipment, simulating the masticatory cycle movement, applying 5N of load and recording the open circuit potential (OCP). The system operated at 60 cycles per minute, a total of 7500 cycles after 15 minutes, corresponding to the daily tooth contact. Artificial saliva at pH 3.0; 6.5 and 9.0 was used and surface roughness measurements were performed before and after the experimental tribocorrosion tests in a laser confocal microscope. After the tests, the saliva was stored in a DNA-free Falcon tubes and subjected to measurement of the ion release to the solution by means of ICP-MS analysis. The behavior of the alloys in contact with the zirconia ball during the experimental tribocorrosion performed in open circuit potential changed according to the pH (P<0.001) and the casting technique (P<0.001). All samples trended to repassivate when the ball contact was removed, indicating new formation of the protective film on alloy surface. The ion release was higher in the samples casted by flame and in contact with pH 3.0 (acid), nickel analyte being released in a higher concentration (P=0.010). However, the values found are below the limits specified to induce cytotoxicity and cellular changes. The results reflected that the samples casted by flame presented surface roughness statistically greater than those casted by plasma (P=0.042) and it was observed in these samples the presence of surface defects and possible casting flaws that enhance the corrosion process. The pH of the saliva and the casting technique presented influence on the repassivation behavior of the alloys, surface roughness and quantity of ions released into the environment, where the best results were found when the plasma casting technique was used.
4

From nanoscale to macroscale, using the atomic force microscope to quantify the role of few-asperity contacts in adhesion

Thoreson, Erik J. 09 January 2006 (has links)
The surface roughness of a few asperities and their influence on the work of adhesion is of scientific interest. Macroscale and nanoscale adhesion data have given seemingly inconsistent results. Despite the importance of bridging the gap between the two regimes, little experimental work has been done, presumably due to the difficulty of the experiment needed to determine how small amounts of surface roughness might influence adhesion data lying in between the two scales. To investigate the role of few-asperity contacts in adhesion, the pull-off force was measured between different sized AFM (Atomic-Force Microscope) tips that had different roughnesses and sample surfaces that had well-controlled material properties. The spring constant of the cantilever, the deflection of the cantilever, and the radius of the cantilever tip were measured before each experiment. There were seventeen tips of four different types, with radii from 200 nm to 60 ìm. The samples were unpatterned amorphous silicon dioxide die with two types of surface conditions: untreated and treated with a few angstroms of vapor deposited diphenylsiloxane. We observed that the pull-off force was independent of the radius of the AFM tip, which was contrary to all continuum-mechanics model predictions. To explain this behavior, we assumed that the interactions between the AFM tip and sample were additive, material properties were constant, and that the AFM tip, asperities, and sample surfaces were of uniform density. Based on these assumptions, we calculated a simple correction due to the measured Root Mean Square (RMS) surface roughness of the AFM tips. The simple correction for the RMS surface roughness resulted in the expected dependence of the pull-off force on radius, but the magnitudes were higher than expected. Commercial and heat-treated AFM tips had minimal surface roughness and result in magnitudes that were more reliable. The relative uncertainty for the pull-off force was estimated to be 10% and the work of adhesion was estimated to be 15%. In this thesis, we derive how the cantilever and tip parameters contribute to the measured pull-off force, show how the corrected results compare with theory, and demonstrate how the AFM probes were calibrated. Although much work is still needed, the work presented here should expand the understanding of adhesion between the nanoscale and macroscale.
5

Resistência à degradação biológica, química e mecânica de materiais resinosos nanoparticulados / Resistance to degradation biological, chemical and mechanical resin materials nanofillers

Paula, Andreia Bolzan de 18 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:24:32Z (GMT). No. of bitstreams: 1 Paula_AndreiaBolzande_D.pdf: 4070151 bytes, checksum: 59b6aec78bd6931d2430106db002b0dc (MD5) Previous issue date: 2011 / Resumo: O avanço da Odontologia Estética tem sido impulsionado pela introdução de novos materiais restauradores, tais como os nanoparticulados, os quais têm demonstrado bom desempenho mecânico e excelentes propriedades ópticas. Entretanto, deve-se considerar que os materiais restauradores estão constantemente sujeitos aos desafios térmicos, mecânicos e químicos na cavidade bucal que podem acarretar danos a estes materiais, num processo denominado degradação. Dessa forma, os objetivos nesta tese, composta por 2 capítulos, foram: (1) avaliar a morfologia e a rugosidade de superfície de materiais nanopartículados quando submetidos a biodegradação e abrasão por escovação e (2) avaliar os efeitos do armazenamento em diferentes soluções simuladoras da dieta ácida na rugosidade e dureza de superfície de materiais restauradores. No capítulo 1, vinte espécimes obtidos de cada material (Vitremer, Ketac N100, TPH Espectrum e Filtek Z350) foram divididos em dois grupos de armazenamento (n=10): umidade relativa e bioflime de S. mutans. Após sete dias, todos os espécimes foram lavados em ultrassom para a mensuração da rugosidade de superfície (Ra) e avaliação em microscopia eletrônica de varredura. Seguidamente, o teste de abrasão por escovação foi conduzido no grupo biodegradado e os espécimes reavaliados. Os dados foram submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey (p<0.05). Após a biodegradação o ketac N100 apresentou os maiores valores de Ra. Quando as amostras biodegradadas foram submetidas à abrasão por escovação, o compósito Z350 apresentou os menores valores de Ra. No capítulo 2, foram confeccionados espécimes (5mm-diâmetro; 2mm-espessura), dos materiais utilizados no Capítulo 1, os quais foram divididos em 4 grupos (n=30). Após 24h, foram realizados os procedimentos de acabamento e polimento e os testes de dureza Knoop (KHN) e rugosidade de superfície. Seguidamente, cada grupo foi dividido em 3 subgrupos (n=10) de acordo com o meio de armazenagem: saliva artificial, suco de laranja e Coca-Cola®. A rugosidade de superfície e dureza Knoop dos espécimes foram reavaliadas após 30 dias de armazenamento e os dados submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey (p<0,05). Os compósitos apresentaram menor Ra e maior KHN que os materiais ionoméricos em todas as situações estudadas. Após a degradação química, a diminuição significativa da KHN foi observada para todos os materiais, enquanto o aumento da Ra foi observado nos materiais ionoméricos armazenados em Coca-Cola® e suco de laranja. O compósito Z350 apresentou valores similares de KHN após a erosão qualquer que fosse a solução de armazenamento. Para os outros materiais, a Coca-cola e o suco de laranja provocaram maiores reduções nos valores de KHN. Com base nos resultados obtidos pode-se concluir que nanopartículas incorporadas aos materiais estudados exerceram influência significativa para a obtenção de maior resistência frente à degradação biomecânica. No entanto, a presença de nanopartículas não influenciou na resposta à erosão quanto à rugosidade e dureza Knoop / Abstract: Esthetic Dentistry has increasingly advanced with the introduction of new restorative dental materials, such as nanofilled materials, which have demonstrated better mechanical behavior and excellent optical properties. However, restorative materials are constantly subjected to thermal, mechanical and chemical challenges in the oral cavity that leads to damage of these materials in a process called degradation. The objectives of this dissertation were to evaluate: (1) the morphology and surface roughness of nanofilled materials subjected to biodegradation and brushing and (2) the effects of storage in different acid diet simulating solutions on roughness and surface hardness of resin based restorative materials. In the study 1, twenty specimens obtained from each material (Vitremer, Ketac N100, TPH Espectrum e Filtek Z350) were divided into two storage groups (n=10): relative humidity (control) and Streptococcus mutans biofilm (biodegradation). After 7 days of storage, roughness values (Ra) and micrographs by Scanning Electron Microscopy (SEM) were obtained. In a second experimental phase, the specimens previously subjected to biodegradation were abraded via toothbrushes (mechanical degradation). Next, these specimens were washed, dried, and reassessed by roughness and SEM. The data were submitted to repeated measures three-way ANOVA and Tukey's tests (p<0.05). After biodegradation, Ketac N100 presented the highest Ra values. Concerning bio plus mechanical challenges the nano composite Filtek Z350 exhibited the best resistance to cumulative challenges proposed. In the study 2, disc-shaped specimens (5mm-diameter; 2mm-thick) of the same materials used on study 1 were obtained according to the manufacturers' instructions, thereby forming four groups (n=30). After 24h, polishing procedures were performed and initial hardness(KHN) and roughness(Ra) measurements were realized. Next, each group was divided into three subgroups (n=10) according to storage media: artificial saliva, orange juice and Coca-Cola®. After 30 days of storage, the specimens were reevaluated about Ra and KHN. Data were tested for significant differences by three-way ANOVA and Tukey (p<0.05). It was observed that composites presented lower roughness values and higher hardness values than ionomeric materials under all storage conditions. After erosion, KHN of all experimental samples dropped significantly, while only the Ra of ionomeric materials increased, depending on the media, with a markedly negative impact of Coca-Cola® and orange juice. There was not difference among storage media for Filtek Z350 regarding to KHN values. Based on the results it can be concluded that nanofillers incorporated into the studied materials was important to obtain greater resistance against biomechanics degradation. However, the presence of nanofillers did not influence the surface roughness and Knoop hardness when the tested materials underwent to erosion / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários

Page generated in 0.0263 seconds