Test av brandskyddslösning på radhusvindar med innertak av råspont / Empirical experiment of fire protection solutions to rowhouses with ceilings of tongue and groove boards

Sälgström, Mattias January 2021 (has links)
Bränder i radhus har under en längre tid varit förödande, oftast med hela radhuslängor totalförstörda. Branden sprider sig upp till vinden för att normalt mötas av en bristande avskiljande vägg. För att förebygga dessa katastrofala bränder genomför räddningstjänster runtomkring landet inspektioner och tillsyner av radhusvindarna så att de klarar av minst 30 minuter. 30 minuter har tidigare varit den minimumtid som en avskiljande vägg på vinden ska stå emot en brand. Dessa tillsyner gjordes med bland annat lagligt stöd från 2 kap. 2 § i lagen om skydd mot olyckor som säger att ägaren ska i skälig omfattning vidta de åtgärder som behövs för att förebygga bränder. Detta innebär att vindar som tidigare haft godkänt brandskydd för 30 minuter, har efter tillsynerna bevisas inte klara av den påstådda tiden och behöver åtgärda denna brist.  En av lösningarna vid brister på radhus med innertak av råspont är att sätta en 60 cm lång gipsskiva ut ifrån den avskiljande väggen längst taket på båda sidorna av väggen. Detta är tänkt att hjälpa till att förhindra, inte stoppa, en brand så pass länge att den avskiljande väggen kan upprätthålla sitt brandskydd i minst 30 minuter. Enligt existerande teori ska en gipsskiva hålla i ca 15-20 minuter. Problemet är att detta lösningsförslag saknar empiriskt underlag. I denna rapport togs tre moduler fram för att undersöka om branden kunde ta sig över en oskyddad och skyddad avskiljande vägg. Som brandkälla anpassades en heptanbrand för att efterlikna brandkurvan ISO 834, även känd som standardbrandkurvan. Första brandförsöket med första modulen stötte på flera stora problem medan övriga två moduler, efter modifieringar, gav rimliga resultat. Resultatet visar att branden inte kunde ta sig över en oskyddad vägg men att en skyddad vägg höll sig bättre. Med ca 8 minuter för brand-gas, -rök att ta sig över men 38 minuter innan genombränning, öppen låga, för oskyddad avskiljande vägg. För skyddad avskiljande vägg tog det över 46 minuter innan brandgas började ta sig över avskiljande väggen.  Vidare analyseras och diskuteras resultatets trovärdighet utifrån uppmätt effekt och temperaturer samt modulens uppbyggnad. Temperaturkurvorna var för sig bedöms trovärdiga även om de skiljer sig ifrån varandra mellan testerna. Framtagna effekten höll sig överraskande väl mot antagna effektens värde. Slutsatsen blev att en brand inte kan ta sig genom en oskyddad avskiljande vägg inom 30 minuter men att en skyddad vägg stod anmärkningsvärt bättre emot branden. / Fires in row houses have under a long time had devastating consequences, often with several family’s homes total destroyed. Fires usually go up to the attic where it normally is meet with deficient firewalls that doesn’t prevent fire from spreading to adjacent attics.  To prevent these catastrophes fires, fire brigades all-around Sweden carry through inspections and oversight on these deficient firewalls so that it can stand against a fire for at least 30 minutes. By Swedish law, the owner of a house must, within reasonably scale, prevent fires from spreading. This includes buildings that previously had acceptably fire prevention for its time of construction but nowadays, with new information, can be proven to not maintains its alleged prevention time. 30 minutes were the minimal time that have previously been accepted as a firewall in the attic.  One of the solutions to deficiency with attic ceilings of so called “råspont”, translated to “tongue and groove boards”, is to extend a 60 cm gypsum board out from the firewall onto the ceiling, on both side of the firewall. This is to help prevent the fire from spreading to next attic within 30 minutes. The main principle is that a single gypsum board can withstand ca 15-20 minutes of fire before failing. The problem is that these solutions is only theoretical, and no empirical experiment have been done to test this solutions reliability. In this report, three modules were designed and tested to see if a fire could get through/over a firewall with, and without, a gypsum board protection within 30 minutes. As a source of fire, a heptane fire was designed to imitate ISO 834 fire curve, also known as standard fire curve. First test of the modules had quite a bit of problems and failure but the other two, after some rearrangement and fixes, delivered somewhat reliable results. The results shows that the fire couldn’t get through an unprotected firewall within 30 minutes, but a protected firewall withstand the fire considerably longer. The unprotected firewall let through smoke around 8 minutes and an open flame was visible around 38 minutes. The protected firewall started to let through smoke after 46 minutes mark. There after analyzed and discussed the reliability of the experiment according to measured heat release rate (HRR) and temperature curve. The temperature curves are each of they own reasonable and believable but differs from one another. The measured HRR were surprisingly accurate against the previously calculated HRR.  The conclusion was that a fire couldn’t get over an unprotected firewall within 30 minutes but that a protected firewall held considerably longer against a fire.

Page generated in 0.0727 seconds