• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 890
  • 468
  • 94
  • 20
  • 9
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 1532
  • 563
  • 362
  • 311
  • 246
  • 233
  • 192
  • 166
  • 155
  • 152
  • 151
  • 135
  • 131
  • 110
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Sous le bonnet rouge

Croyet, Jérôme Chassagne, Serge January 2003 (has links)
Reproduction de : Thèse de doctorat : Histoire : Lyon 2 : 2003. / Titre provenant de l'écran-titre. Bibliogr. Notes bibliogr. Répertoire biogr.
52

Syndrome des jambes sans repos

Lepavec, Cécile Grimaud, Nicole January 2007 (has links) (PDF)
Thèse d'exercice : Pharmacie : Université de Nantes : 2007. / Bibliogr.
53

Emetteur à 60 GHz avec des possibilités radio logicielle / 60 GHz wireless transmitter with SDR capabilities

Muller, Jonathan 20 September 2011 (has links)
La radio à 60 GHz émerge comme l'un des candidats les plus prometteurs pour la transmission de données à haut débit (10 Gb/s) sur des courtes distances (1 à 10m). La radio 60 GHz à l’état de l’art utilise des émetteurs-récepteurs exclusivement analogiques. Les technologies CMOS sub-microniques profondes ont permis le développement de circuits de bande de base numériques pour les communications sans fil à plus basse fréquence. Dans ce travail une architecture d’émetteur numérique destinée aux communications à 60GHz a été étudiée. Elle est basée sur un interpolateur numérique et un DRFC (convertisseur direct numérique-RF), structure qui associe un DAC et un mélangeur pour réaliser une conversion directe du flux de données numériques à la fréquence RF. Le standard IEEE 802.15.3c pour communications sans fil à 60 GHz a été pris comme référence pour étudier l'émetteur proposé. Le flux de données numérique à la sortie en bande de base (échantillonnés à 2,5 Géch / s) doit être sur-échantillonné, et les répliques du signal aux multiples de la fréquence d'échantillonnage initiaux doivent être filtrés. Ces images sont atténués avec un interpolateur filtre FIR fonctionnant à 10 Gech/s.Un prototype de l'interpolateur à10Gech/s a été implémenté dans une technologie CMOS 65nm pour prouver la faisabilité du concept. Le filtre utilise des coefficients « puissances de deux » et de la logique dynamique pour atteindre le taux d'échantillonnage requis. Le circuit prototype de ce transmetteur démontre la pleine fonctionnalité jusqu'à 9,6 GHz et consomme 408mA (571mW) avec une tension d'alimentation de 1.4V. La surface de silicium centrale est de 650 x 170 um2. / Recent deep sub-micron CMOS technologies have allowed the development of digital baseband circuits for wireless communications. 60 GHz radio has emerged as one of the most promising candidates for high-data-rate (10 Gb/sec), short-distance (1 to 10 m), wireless telecommunication systems. State-of-the-art 60 GHz radio use exclusively analog transceivers. Recent deep sub-micron CMOS technologies have allowed the development of highly digital transceivers for wireless communications in the lower GHz range. In this work, a digital transmitter architecture targeted at 60GHz c communications has been studied. It is based on the combination of an interpolator and a DRFC (digital-to-RF converter), structure which combines a DAC and mixer in order to realize a direct conversion of the digital data stream to the RF frequency. The 60 GHz wireless standard IEEE 802.15.3c has been taken as a reference to study the proposed transmitter. The digital data stream at the baseband output (sampled at 2.5 GS/s) needs to be oversampled and resulting replicas of the signal at multiples of the initial sampling frequency have to be filtered. Images at multiples of the initial sampling frequency are attenuated with an interpolator FIR filter working at 10 GS/s. A prototype of the 10GS/s interpolator has been implemented in a 65nm CMOS technology to prove the feasibility of the concept. The filter uses powers of two coefficients and dynamic logic to reach the required sampling rate. The fabricated prototype transmitter IC demonstrates full functionality up to a 9.6 GHz and consumes 408mA (571mW) with a 1.4V supply voltage. The core area is 650 x 170 um2.
54

L'exploration des représentations des intervenants sociaux concernant la santé et sa place dans l'intervention auprès des femmes itinérantes

Lavallières, Lyse, January 2004 (has links)
Thèses (M.Serv.Soc.)--Université de Sherbrooke (Canada), 2004. / Titre de l'écran-titre (visionné le 20 juin 2006). Publié aussi en version papier.
55

Impact des charges de compression sur l'intégrité des puces renversées sur un substrat organique sans capot et sans encapsulant

Cloutier, Antoine January 2017 (has links)
La tendance actuelle vers l’encapsulation d’un assemblage comportant plusieurs puces favorise l’incorporation d’un procédé de réusinage compatible avec l’enlèvement et le remplacement d’une puce défectueuse. La vérification électrique est un procédé inhérent au réusinage qui identifie facilement les puces défectueuses sans en compromettre leur intégrité. Malheureusement, l’aspect qui optimise l’intégrité mécanique et électrique des dispositifs, soit l’encapsulant (underfill), rend les étapes subséquentes d’enlèvement des puces extrêmement difficile. Il devient alors souhaitable d’évaluer le comportement de certaines puces sans underfill qui sont sujettes aux conditions de vérifications électriques souhaitées afin de déterminer s’il existe une zone de test favorable à la qualité et la fiabilité du produit. Ceci est d’autant plus vrai en considérant le peu de données publiées concernant un chargement en compression qu’une puce sans underfill et sans capot peut supporter. Ce projet de recherche présente une étude du comportement des puces renversées sans capot, utilisant un alliage SAC, qui est sans plomb, pour les interconnexions, face à une charge compressive appliquée directement. Les puces sont assemblées sur un substrat organique sans underfill dans une configuration à plusieurs puces. Pour différentes tailles de puces, une série de compressions ont été observées afin de couvrir une vaste étendue de forces potentiellement utilisées pour assurer le contact électrique du laminé non planaire. Les chargements ont été faits à température ambiante et élevée ainsi qu’à angle normal et incliné. La caractérisation par l’analyse des courbes de chargement, la coplanarité, la mesure des hauteurs des interconnections et la tomographie par rayon X a démontré qu’un angle normal ne provoquait qu’une légère déformation qui était relativement indépendante de la température ou de la force dans l’étendu testé. Bien que les données de fluage semblent entrer dans le cadre des modèles précédemment publiés et un nouveau modèle plus juste a été créé avec l’aide de test de nanoindentation. L’inclinaison du chargement a démontré produire des déformations significatives qui, durant un test électrique typique de 20 minutes, étaient similaire pour un faible ou un grand chargement. Par contre, ces déformations avaient tendance à être plus importantes pour une température élevée et pour une petite taille de puce. De telles déformations ont démontrés induire une recristallisation des grains en une taille plus fine sans retrouver leur forme après un recuit. De plus, les déformations sévères ont démontrées une présence de fissurations à température ambiante et d’espace réduit à température élevée pouvant nuire à l’intégrité de l’assemblage. Un cyclage thermique de 1000 cycles n’a pas induit de défaillance électrique pour le nombre d’échantillons testés, mais des tests avec un plus grand échantillonnage sont recommandés. En somme, cette étude conclue qu’une vérification électrique dans des conditions normales d’une puce sans capot ne va pas endommager l’intégrité des interconnections sans plomb. Toutefois, un contrôle des procédés robustes est nécessaire afin d’éviter des conditions anormales résultant en une inclinaison de la charge qui pourrait compromettre l’intégrité des assemblages.
56

Mucin structure and mucosal transport of polyphenols

Georgiades, Pantelis January 2014 (has links)
The rheological and structural characteristics of gastric (MUC5AC) and duodenal (MUC2) mucin solutions, the structural basis of the adherent mucus layer in the two organs, and their interactions with polyphenols, the phytochemicals which are linked with a number of health benefits, were investigated using particle tracking microrheology and scattering techniques. We used biochemically well characterised porcine mucins as models for human mucins to characterise their viscoelasticity, structure and dynamics as a function of concentration and pH. Additionally, the mesoscopic forces that mediate the integrity of the network were investigated using reducing (dithiothreitol) and chaotropic agents (guanidinium chloride and urea). Mucins in solution were found to be flexible and three distinct viscoelastic regimes were identify ed. At neutral pH, both types of mucin were found to form flexible self-assembled semi-dilute networks above a critical concentration (c*) where the viscosity scales as c 0.53+-0.08 and c 0.53 +-0.06 for MUC5AC and MUC2 respectively. Above a second critical concentration, the entanglement concentration (Ce), the peptide backbones reptate and entangle and there is a sharp increase in viscosity, c 3.92+- 0.38 for MUC5AC and c 5.1 0+-0.08 for MUC2. At low pH, both types of mucin solution undergo a sol-gel transition, forming pH-switchable gels. The addition of tea-derived polyphenols and tea extracts to the mucin solutions has revealed the strong interaction of galloylated phenolic molecules with mucins, which eventually leads to the gelation of the solution. Cross-linking of mucins by galloylated polyphenols is thus expected to have an impact on the physicochemical environment of the stomach and small intestine; the alteration of the organisation of the mucin polymer network is expected to modulate the barrier properties of the two adherent mucus layers which will affect nutrient absorption and the viscoelastic microenvironment of intestinal bacteria.
57

Exploitation de la dynamique du geste en IHM : application aux fonctions de transfert pour le pointage et l'extraction d'événements discrets / Exploiting the dynamics of the gesture in HCI : applications to the transfer functions for pointing and extracting discrete events

Deblonde, Jean-Philippe 28 September 2012 (has links)
La dynamique du geste reste peu exploitée dans le domaine de l’interaction hommemachinealors qu’elle permet de définir des critères simples d’analyse de l’intention desutilisateurs. Sa principale utilisation porte sur les fonctions de transfert des périphériquesisotoniques. Ces fonctions permettent d’établir une relation entre le geste de l’utilisateureffectué dans l’espace moteur avec le périphérique de pointage (i.e. souris) et le mouvementdu pointeur dans l’espace visuel. Les fonctions de transfert utilisées par les systèmesd’exploitation modernes restent cependant fortement méconnues même si des études ontmontré qu’elles ont un impact sur les performances des utilisateurs. Pour caractériser cesfonctions, nous avons développé un périphérique électronique qui simule une souris réelleet qui permet d’obtenir les fonctions de transfert de tout système. Nous avons ainsi puobtenir les fonctions des systèmes Windows, Linux et Mac et nous avons observé des différencesnotables entre ces fonctions. Nous avons ensuite cherché à optimiser ces fonctionsen réduisant au maximum le nombre de leurs degrés de liberté. En faisant varier de manièreexhaustive ces paramètres, nous avons ainsi pu observé des différences significativesqui montrent qu’il existe une famille de fonctions pour lesquelles les performances sontoptimales. Enfin, nous nous sommes intéressés à l’utilisation de la dynamique du gestedans un autre contexte, celui de la génération d’événements discrets, pertinent dans lecadre des interfaces sans contact de type Kinect. Nous avons ainsi montré qu’il est possiblede distinguer la sélection du déplacement dans une tâche d’interaction 3D. La techniquedéveloppée est ensuite améliorée dans le cas des cibles de petites tailles et son applicationdans un contexte d’interaction 2D est évaluée. / The dynamic of the gesture is not used a lot in the domain of human-computer interaction,while it can help to define some simple heuristics to analyze the intents of users.Its first use is related to transfer functions for isotonic devices. Those functions establisha relationship between the gesture of the user, executed in motor space with the pointingdevice (i.e. a mouse), and the movement of the pointer in the visual space. The transferfunctions used by modern operating systems are still not well known, even if somestudies have shown they have an impact on user’s performance. To characterize thosefunctions, we have developed an electronic device which simulates a real mouse, and thatcan retrieve the transfer functions of any system. We have then exposed the functions ofthe Windows, Linux and Mac systems, and we observed some visible differences betweenthose functions. We have then tried to optimize those functions by reducing their numberof degrees of freedom. By varying those parameters in an exhaustive way, we have thenobserved some significant differences that show there is a family of functions for whichperformances are optimal. Finally, we were interested in the use of the dynamic of thegesture in another context : the generation of discrete events, useful when dealing withcontact-less interfaces, like the Kinect. We have shown that it is possible to distinguishbetween picking and drag’n’drop in a 3D interaction task. The technique is then improvedin the case of small size targets, and its application in a 2D interaction context isevaluated.
58

Solution Behaviour of Polyethylene Oxide, Nonionic Gemini Surfactants

FitzGerald, Paul Anthony January 2002 (has links)
In recent years there has been increasing interest in novel forms of surfactants. Of particular interest are gemini surfactants, which consist of two conventional surfactants joined by a spacer at the head groups, as they exhibit lower critical micelle concentrations than can be achieved by conventional surfactants. In this work, the self-assembly behaviour of several nonionic gemini surfactants with polyethylene oxide head groups (GemnEm, where n (= 20) is the number of carbons per tail and m (= 10, 15, 20 and 30) is the number of ethylene oxides per head group) were investigated. The Critical Micelle Concentrations (CMCs) were measured using a fluorescence probe technique. The CMCs are all ~2 x 10?7 M, with almost no variation with m. The CMCs are several orders of magnitude lower than conventional C12Em nonionic surfactants. The mixing behaviour of the gemini surfactants with conventional surfactants was also studied. They obeyed ideal mixing behaviour with both ionic and nonionic surfactants. Micelle morphologies were studied using Small Angle Neutron Scattering. The gemini surfactants with the larger head groups (i.e. Gem20E20 and Gem20E30) formed spherical micelles. Gem20E15 showed strong scattering at low Q, characteristic of elongated micelles. As the temperature was increased towards the cloud point, the scattering approached the Q-1 dependence predicted for infinite, straight rods. The existence of anisotropic micelles was supported by the viscosity of Gem20E15, which increases by several orders of magnitude on heating towards its cloud point. Phase behaviour was determined using Diffusive Interfacial Transport coupled to near-infrared spectroscopy. Much of the behaviour of these systems is similar to conventional nonionic surfactants. For example, Gem20E10 forms a dilute liquid isotropic phase (W) coexisting with a concentrated lamellar phase (La) at around room temperature and forms a sponge phase at higher temperatures. This is similar to the behaviour of C12E3 and C12E4. The other surfactants studied are all quite soluble in water and form liquid isotropic and hexagonal phases from room temperature. At higher concentrations Gem20E15 formed a cubic and then a lamellar phase while Gem20E20 formed a cubic phase and then an intermediate phase. This is also comparable to the phase behaviour of conventional nonionic surfactants except the intermediate phase, which is often only observed for surfactant systems with long alkyl tails.
59

Conception et réalisation d'un système de développement, exécutable sur mini-ordinateur Nord-10, pour un microprocesseur spécialisé

Huot, Gérard 06 December 1978 (has links) (PDF)
sans
60

Etude expérimentale des violations d'invariance dans les réactions de neutrinos et d'antineutrinos à haute énergie

Blaes, Reiner 27 June 1983 (has links) (PDF)
sans

Page generated in 0.0664 seconds